• Title/Summary/Keyword: Sanders

검색결과 109건 처리시간 0.019초

관절내 종골 골절에 대해 AO 종골 금속판을 이용한 수술적 치료 결과 (Surgical Outcomes of Intra-articular Fractures of Calcaneus using AO Calcaneal Plate)

  • 김성택;윤태현;박진범;이준영
    • 대한족부족관절학회지
    • /
    • 제13권1호
    • /
    • pp.75-79
    • /
    • 2009
  • Purpose: To evaluate the outcomes of intra-articular calcaneal fractures treated using AO calcaneal plate surgically. Materails and Methods: Total 15 cases of intra-articular calcaneal fracture that treated with open reduction and internal fixation using AO calcaneal plate were evaluated. The patients were followed over a mean period of 19.8 months. The mean age was 41.6 years. By Sanders classification, there were 2 cases of type II, 10 cases of type III, and 3 cases of type IV. We evaluated radiological outcomes by Bohler angle, Gissane angle, calcaneal hight, calcaneal width and clinical outcomes by Creighton-Nebraska health foundation score. Results: All fractures united at a mean duration of 13.3 weeks. Radiologically, the mean preoperative Bohler angle was $8.5^{\circ}$ and restored to $23.3^{\circ}$. The mean preoperative Gissane angle was $118.7^{\circ}$ and restored to $124.2^{\circ}$. The mean preoperative calcaneal hight was 30.8 mm and restored to 38.9 mm. The mean preoperative calcaneal width was 41.3 mm and restored to 35.3 mm. 10 cases had excellent and good clinical outcomes and 5 cases having fair outcome. Conculsion: In our study, open reduction and internal fixation using AO calcaneal plate showed good results with anatomical restoration of articular surface and stable fixation without late collapse.

  • PDF

관절 내 종골 골절의 수술적 치료에 있어 관절 내시경 사용의 유용성 (The Usefulness of Arthroscopy in the Operative Treatment of Intra-Articular Calcaneal Fracture)

  • 정경칠;곽희철;김창완;김정한;박대현
    • 대한족부족관절학회지
    • /
    • 제13권1호
    • /
    • pp.55-59
    • /
    • 2009
  • Purpose: We tried to evaluate the usefulness of the arthroscopy in the operative treatment of intra-articular calcaneal fracture. Materials and Methods: Between March 2005 and May 2008, 9 patients with intra-articular calcaneal fractures(Tongue type or Sanders type IIC) were treated with arthroscopically assisted percutaneous reduction and screw fixation. American orthopedic foot and ankle society (AOFAS) ankle-hindfoot score, visual analogue scale (VAS), preoperative and postoperative Bohler's angle and the rate of complication were evaluated. Results: AOFAS score at postoperative 1 year was 88.2 (range, 71-92), and mean VAS score was 2.8 (range, 1-4). Bohler angle was improved from preoperative mean $16.2^{\circ}$ to postoperative mean $29.7^{\circ}$. There were no complications such as wound problem, infection or nerve injury. Conclusion: Subtalar arthroscopy provides precise view of posterior facet during the operation. Therefore, it can be a useful tool in treating intra-articular calcaneus fractures, especially tongue type and Sanders type IIC fractures.

  • PDF

STUDY OF SPECTRAL ENERGY DISTRIBUTION OF GALAXIES WITH PRINCIPAL COMPONENT ANALYSIS

  • Kochi, Chihiro;Nakagawa, Takao;Isobe, Naoki;Shirahata, Mai;Yano, Kenichi;Baba, Shunsuke
    • 천문학논총
    • /
    • 제32권1호
    • /
    • pp.209-211
    • /
    • 2017
  • We performed Principle Component Analysis (PCA) over 264 galaxies in the IRAS Revised Bright Galaxy Sample (Sanders et al., 2003) using 12, 25, 60 and $100{\mu}m$ flux data observed by IRAS and 9, 18, 65, 90 and $140{\mu}m$ flux data observed by AKARI. We found that (i)the first principle component was largely contributed by infrared to visible flux ratio, (ii)the second principal component was largely contributed by the flux ratio between IRAS and AKARI, (iii)the third principle component was largely contributed by infrared colors.

Superfluorescence from Magnetically Formed Quantum Dots: the Excitation Pulse-Width Dependence

  • Jho, Young-Dahl;Lee, Jin-Ho;Sanders, Gary D.;Stanton, Christopher J.;Reitze, David H.;Kono, Junichiro;Belyanin, Alexey A.
    • Journal of the Optical Society of Korea
    • /
    • 제12권1호
    • /
    • pp.57-61
    • /
    • 2008
  • We investigated the laser pulse-width dependence of dense plasmas confined within the magnetic length of $In_{0.2}Ga_{0.8}As$/GaAs multiple quantum wells under high magnetic fields up to 31 T. To fully fill the Landau levels of effectively zero-dimensional system, we used intense femtosecond (fs) laser pulses to create carrier densities near $10^{13}/cm^2$. The observed photoluminescence showed a characteristic of superfluorescence, above critical magnetic field when being excited by pulses shorter than coherence buildup time.

Application and testing of a triple bubbler sensor in molten salts

  • Williams, A.N.;Shigrekar, A.;Galbreth, G.G.;Sanders, J.
    • Nuclear Engineering and Technology
    • /
    • 제52권7호
    • /
    • pp.1452-1461
    • /
    • 2020
  • A triple bubbler sensor was tested in LiCl-KCl molten salt from 450 to 525 ℃ in a transparent furnace to validate thermal-expansion corrections and provide additional molten salt data sets for calibration and validation of the sensor. In addition to these tests, a model was identified and further developed to accurately determine the density, surface tension, and depth from the measured bubble pressures. A unique feature of the model is that calibration constants can be estimated using independent depth measurements, which allow calibration and validation of the sensor in an electrorefiner where the salt density and surface tension are largely unknown. This model and approach were tested using the current and previous triple bubbler data sets, and results indicate that accuracies are as high as 0.03%, 4.6%, and 0.15% for density, surface tension, and depth, respectively.

종골 골절의 치료-광범위 외측 접근법 (Calcaneal Fractures-Extended Lateral Approach)

  • 천성광;김학준
    • 대한족부족관절학회지
    • /
    • 제17권2호
    • /
    • pp.79-83
    • /
    • 2013
  • Calcaneus is largest tarsal bone and the fracture of calcaneus is most common tarsal fractures. Calcaneal fractures are divided into extra-articular and intra-articular fractures. Intra-articular calcaneal fractures could be classified as tongue type and joint depression type using simple lateral radiograph (Essex-Lopresti classification), but Sanders suggested new classification according to involving the posterior facet of calcaneus using computed tomography. The involvement of posterior facet was revealed as more complicated than Essex-Lopresti classification. The principle purpose of treatment of calcaneal fractures are restoration of calcaneal height (B$\ddot{o}$hler angle), width, axis, anatomical reduction of joint and restoration of function through the stable fixation. Good visualization of joint and anatomical reduction could be achieved by extended lateral approach. But, skin problem could be occurred after of extended lateral approach.

THIN-FILM-COATED DETECTORS FOR NEUTRON DETECTION

  • McGregor Douglas S.;Gersch Holly K.;Sanders Jeffrey D.;Klann Raymond T.;Lindsay John T.
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.167-175
    • /
    • 2001
  • Semiconductor diode detectors coated with neutron reactive material are presently under investigation for various uses, such as remote sensing of thermal neutrons, fast neutron counting, and thermal neutron radiography. Theory indicates that single-coated devices can yield thermal neutron efficiencies from 4% to 11 %, which is supported by experimental evidence. Radiation endurance measurements indicate that the devices function well up to a limiting thermal neutron fluence of $10^{13}/cm^2$, beyond which noticeable degradation occurs. Thermal neutron contrast images of step wedges and simple phantoms, taken with dual in-line pixel devices, show promise for thermal neutron imaging detectors.

  • PDF

웹기반 MMORTS 기호작용의 사용자 특성 연구 (A Study on User Characteristics Reflected in Semiotic Process of Web-Based MMORTS)

  • 윤선미
    • 한국게임학회 논문지
    • /
    • 제11권3호
    • /
    • pp.21-30
    • /
    • 2011
  • 웹을 기반으로 하는 MMORTS 게임 형식은 사용자들이 게임을 인지하는 방식 또한 변형시키고 있다. 본 고에서는 MMORTS 게임에서의 사용자들의 기호작용이 MMORPG의 게임과는 다른 양상을 보인다는 점에 주목하고, 이를 퍼스의 삼원론을 통해 분석하고자 한다. MMORTS 에서 사용자들은 아바타와의 거리 두기와 지표기호 읽어내기, 상징기호를 통한 추론하기의 방식으로 기호작용을 일으킨다. 이는 웹기반 MMORTS의 사용자를 관리자, 기호해석자, 전략가로서 칭하게 하는 특성을 이끌어 내게 된다.

알루미늄 합금의 TCG 조직의 형성기구 (Mechanism of Twin Columnar Growth in Aluminum Alloys)

  • 김동건
    • 한국주조공학회지
    • /
    • 제7권3호
    • /
    • pp.192-198
    • /
    • 1987
  • Commercial semicontinuous cast ingots of aluminum alloys often exhibit large grains composed of parallel arrays of continuous lamellae. Each lamella consists of a central {111} coherent twin boundary and wavy solidification boundary. This microstructure is referred to as a twin columnar growth(TCG) structure. The factors influencing the formation of a TCG structure include a unidirectional thermal gradient and the critical range of the alloying element content. The higher the thermal gradient is, the shorter the twin plane spacings are. The composition profile for an untwinned dendrite shows maximums at the positions of the interdendritic channels and the minimum appears at the center of the dendrite. While for twinned dendrite, it has wavy apperance. This profile has two local minimums instead of one shown in the untwinned.

  • PDF

Frequency Response Analysis of Cylindrical Shells Conveying Fluid Using Finite Element Method

  • Seo Young-Soo;Jeong Weui-Bong;Yoo Wan-Suk;Jeong Ho-Kyeong
    • Journal of Mechanical Science and Technology
    • /
    • 제19권2호
    • /
    • pp.625-633
    • /
    • 2005
  • A finite element vibration analysis of thin-walled cylindrical shells conveying fluid with uniform velocity is presented. The dynamic behavior of thin-walled shell is based on the Sanders' theory and the fluid in cylindrical shell is considered as inviscid and incompressible so that it satisfies the Laplace's equation. A beam-like shell element is used to reduce the number of degrees-of-freedom by restricting to the circumferential modes of cylindrical shell. An estimation of frequency response function of the pipe considering of the coupled effects of the internal fluid is presented. A dynamic coupling condition of the interface between the fluid and the structure is used. The effective thickness of fluid according to circumferential modes is also discussed. The influence of fluid velocity on the frequency response function is illustrated and discussed. The results by this method are compared with published results and those by commercial tools.