Evaluation of Adsorbent Sampling Methods for Volatile Organic Compounds in Indoor and Outdoor Air (실내·외 공기 중 휘발성 유기화합물에 대한 흡착 시료채취 방법의 평가)

  • Baek, Sung-Ok;Moon, Young-Hun
    • Analytical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.496-513
    • /
    • 2004
  • This study was carried out to evaluate the performance of sampling and analytical methodology used for the measurement of toxic volatile organic compounds (VOCs) in the ambient air. VOCs were determined by the adsorbent tube sampling and automatic thermal desorption coupled with GC/MSD analysis. Target analytes were 33 compounds including major aromatic compounds such as BTEX, and halogenated compounds. The methodology was investigated with a wide range of different adsorbents which are commercially available and have been frequently adopted for the VOC measurement. A total of 10 adsorbents were tested in this study: 6 carbon-based adsorbents such as Carbotrap, Carbopack B, Carbosieve S-III, Carboxen 1000, Carbotrap C, Activated Charcoal; and 4 polymer-based adsorbents including Tenax, Porapak Q, Chromosorb 102, and Chromosorb 106. The sampling performance was evaluated with respect to the sampling capacity of VOCs with single-adsorbent and multiple-adsorbents methods for standard samples and field samples. As a result, the best adsorbents for single-adsorbent method in the sampling of toxic organic compounds (including benzene, toluene, xylenes etc.) appeared to be Carbotrap, Carbopack B and Tenax TA. On the other hand, Chromosorb 102, Chromosorb 106 and Porapak Q were found to be unsuitable adsorbents for VOC measurement based on thermal desorption method. Multi-adsorbent packings were evaluated with 4 carbon-based adsorbents, which classified by 3 combination sets of double adsorbents and 2 combination sets of triple adsorbents. The results indicated that the most suitable combination for toixc VOC measurements is Carbotrap C with Carbotrap. Multi-sorbents tubes packed with a strong adsorbent such as Carbosieve S-III or Carboxen 1000 were found to be relatively unsuitable for several compounds, not only owing to the effect of migration of adsorbed compounds from weaker adsorbent to stronger adsorbent, but to hydrophobic nature of the adsorbents. Therefore, it should be addressed that selection of a proper adsorbent (or combination of multi sorbents) is extremely important to obtain reliable data for the concentrations of toxic VOCs in indoor and outdoor environments.

Effects of Surface-Treatment by Zinc Salts on Breakthrough and Adsorption Capacity of Toluene in Coconut Activated Carbon Tubes (아연염에 의한 활성탄의 표면처리가 톨루엔의 활성탄관 파괴현상과 포집능력에 미치는 영향)

  • Lee, Jin-Heon;Han, Don-Hee;Kim, Young-Gyu;Son, Bu-Soon;Chung, Moon-Ho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.119-127
    • /
    • 1995
  • The purpose of this study was to determine the effects of surface-treatment by zinc salts on break-through and adsorption capacity of toluene. Firstly, the coconut activated carbon treated the surface with zinc salts, were exposed by the spike sample(toluene, 69.02ppm, $260.1mg/m^3$), and then the effects of zinc salts were examined by using the gas adsorption kinetics. The results obtained were as follows : 1) BET(Brumaure Emmett Teller) surface area were $954.4m^3/g$ in coconut activated carbon treated with 0.0001 N $Zn(NO_3)_3$ $6H_2O$, and $830.3m^2/g$ in coconut activated carbon treated with 0.0001 N $ZnCl_2$. 2) Migration was decreased in coconut activated carbon treated with the thin level of zinc salts. 3) Breakthrough volume were 73.07 L in coconut activated carbon treated with 0.0001 N $Zn(NO_3)_3$ $6H_2O$, and 72.76 L in charcoal treated with 0.0001 N $ZnCl_2$. 4) ${\tau}$ values(the time required for 50% breakthrough) were 1046.1 min in coconut activated carbon treated with 0.0001 N $ZnCl_2$ and 921.2 min in coconut activated carbon treated with 0.0001 N $Zn(NO_3)_3$ $6H_2O$. 5) Maximum adsorption capacity was 53.9 mg/tube in coconut activated carbon treated with 0.0001 N $ZnCl_2$ and 47.4 mg/tube in coconut activated carbon treated with 0.0001 N $Zn(NO_3)_3$ $6H_2O$. In conclusion, the coconut activated carbon treated the surface with the thin concentration of zinc salts, decreased the breakthrough and increased the BET surface area and the adsorption capacity in case of sampling airborne toluene.

  • PDF

The Effect of YouTube BJ Attributes on Information Usefulness, Information Search Satisfaction and Behavioral Intention -Focused on e-Sports Content (유튜브 BJ 속성이 정보의 유용성, 정보탐색만족도 및 행동의도에 미치는 영향 -e-스포츠콘텐츠 중심으로)

  • Kim, Soo-Eun;Lee, Hee-Hwa
    • Journal of Digital Convergence
    • /
    • v.18 no.11
    • /
    • pp.465-475
    • /
    • 2020
  • The purpose of this study was to investigate how the attributes of YouTube BJs, specifically those dealing in e-sports content, affects information usefulness, information search satisfaction, and behavioral intention. To achieve this purpose, data from 229 students collected by convenient sampling of college students were used for final analysis, and analyzed using SPSS 23.0 and AMOS 23.0 programs. The results of the study are as follows: First, the friendliness of the BJ had a significant positive (+) effect on the information usefulness, the information search satisfaction, and the behavioral intention. Second, it was found that the reliability of the BJ did not significantly affect the information usefulness, the information search satisfaction, and the behavioral intention. Third, the information usefulness had no significant effect on behavioral intention, but Information search satisfaction was found to have a significant positive (+) effect on behavioral intention. Therefore, the results of this study are expected to contribute to establishing a strategy for e-sports content production based on the attributes of BJs.

Glomerular Filtration Rate Test Methods and Guidelines (Glomerular Filtration Rate 검사방법 및 가이드라인)

  • Park, Min-Ho;Lee, Ha-Young;Ryu, Hwa-Jin;Yoo, Tae-Min;Noh, Gyeong-Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.97-100
    • /
    • 2018
  • Purpose The glomerular filtration rate (GFR) test is an important indicator of glomerular filtration and has been used to test renal function and the extent of its function. The GFR test is performed by intravenous injection of radioactive medicines made of $^{51}Cr$-EDTA, and blood concentration is measured by taking blood according to the elapsed time. also, PET-CT, bone scan, transfusion and so on will affect the outcome. Therefore, we will improve the quality of the test by providing guidelines for the GFR test for more accurate testing. Materials and Methods 5 mL of physiological saline solution and 2 mL of $^{51}Cr$-EDTA solution are used to make 5 mL of the radiopharmaceutical solution to be injected into the patient. First, the syringe weight is measured before the injection, and then the radioactive medicine is injected into the patient's vein and the syringe weight is measured after the injection. Blood sampling is performed twice in total. In adults, blood is collected 3 hours / 5 hours after injection and in children 2 hours / 5 hours after injection. The blood sample is centrifuged at 3300 rpm for 5 minutes. Standard solution is prepared by filling diluent water up to the scale indicated in the 200-mL volumetric flask, discarding $500{\mu}L$, injecting $500{\mu}L$ of GFR reagent and mixing well. $500{\mu}L$ each of the standard solution is dispensed into two test tubes, and $500{\mu}L$ of each of the plasma samples collected in time is dispensed into two test tubes and measured with a Cobra Counter. Results At present, the reference range applied in this study is $119.5{\pm}30.3ml/min/1.73m2$ for males and $125.2{\pm}28.2ml/min/1.73m^2$ for females. Conclusion The GFR test is conducted using radioactive medical products. GFR testing is performed as a scheduled test, but PET-CT, dialysis and transfusion, which may affect GFR testing, may be scheduled during GFR testing. Therefore, we could get accurate GFR test results by notifying the ward and department beforehand when booking.

A Study on the Quantitative Measurement of Oil Carry-over in Natural Gas Vehicle fueling Station Using A Gravimetric Method (무게측정법을 이용한 천연가스 자동차 충전소 오일전이 정량 분석에 대한 연구)

  • Hwang, Sung-Soo;Oh, Jun-Seok;Kim, Ki-Dong;Oh, Young-Sam;Choi, Kyung-Sik;Kim, Hack-Eun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.1
    • /
    • pp.12-17
    • /
    • 2015
  • The core of the CNG fueling station is the compressor and most of CNG compressors in Korea require lubrication. Lubrication oil of CNG compressor that can be transferred into the pressure regulators and the engines of fueling system can cause a negative effect on NGV(Nature Gas Vehicle) performance during refueling due to oil Carry-over. In order to avoid the problem, it is necessary to enhance the quality of the compressed natural gas by measuring quantitatively the amount of the transferred oil. In this research, a sampling device and sampling tube were developed, which can be used with a gravimetric method of detection to measure CNG oil Carry-over. In addition, CNG samples were taken at 6 pre-selected CNG fueling stations and analysed for their trace oil Carry-over. The measured total oil Carry-over ranged from 2.569 to 6.509 ppm. This test measurements were compared with those of previous studies to verify the results.

A comparative analysis of volatile organic compound levels in field samples between different gas chromatographic approaches (분석기법의 차이에 따른 현장시료의 VOC 분석결과 비교연구: 분석오차의 발생 양상과 원인)

  • Ahn, Ji-Won;Pandey, Sudhir Kumar;Kim, Ki-Hyun
    • Analytical Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.465-476
    • /
    • 2010
  • In this study, a number of volatile organic compounds (VOCs) including benzene, toluene, p-xylene, styrene, and methyl ethyl ketone were analyzed from samples collected in ambient air and under the field conditions. These samples were analyzed independently by two different set-ups for VOC analyses, i.e., between [1] gas chromatography/flame ionization detector with tube sampling - (F-T system) and [2] gas chromatography/mass spectrometer with bag sampling (M-B system). The analytical results derived by both systems showed fairly similar patterns in relative sense but with moderately large differences in absolute sense. The results of M-B system were high relative to F-T system with the F-T/M-B ratio below 1. If the relative biases of the two measurement techniques are derived in terms of percent difference (PD) in concentration values, the results were generally above 35% on average. A student t-test was applied to investigate the statistical significance of those differences between the systems. The results of both analytical systems were different at 95% confidence level for toluene, p-xylene, styrene, and methyl ethyl ketone (P < 0.043). However, F-T and M-B systems showed strong correlations for toluene and p-xylene. The observed bias is explained in large part by such factors as the differences in standard phases used for each system and the chemical loss inside the bag sampler.

Finite Element Analysis on the Strength Safety of a Fuel Tank for Highly Compressed Gas Vehicle (수술실 내의 아산화질소($N_2O$) 노출평가)

  • Baek, Jong-Bae;Uhm, Min-Yong
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.6
    • /
    • pp.34-38
    • /
    • 2009
  • Nitrous oxide, which is used as an anesthetic gas, has been shown to be a chronic health hazard. It is necessary to monitor and control the nitrous oxide exposure of the operating theaters staff. In this study, N2O exposure level of the operating nurses is assessed with a GC-ECD. The nitrous oxide gas is collected on a molecular sieve 5A contained in a glass tube and desorbed for 12 hours at $100^{\circ}C$ in heating block. As a result of the test using GC-ECD, calibration curve's $R^2$ of $N_2O$ is 0.9992, LOD is $0.96{\mu}g$/injection, LOQ is $3.21{\mu}g$/injection, desorption efficiency is 94.78 4.50% in average and break through is within 10% compared with the concentration. The average concentration before operation is 5.12ppm and it is 42.3ppm during operation. There are a significant difference showing that the P value is lower than 0.05. Assessing exposure level to nitrous oxide based on nurses' working positions, the exposure levels do not show significant difference( P>0.005). And $N_2O$ in active sampling method is higher than passive sampling method(P<0.05).

  • PDF

Characteristics of Hazardous Substances Generated from Combustible Compressed Wood Used during Live Fire Training for Firefighters (소방 실화재 훈련에서 사용하는 압축목재 가연물에서 발생하는 유해물질 특성)

  • Lee, Yongho;Kim, Jinhee;Kim, Uijin;Choi, Won-Jun;Lee, Wanhyung;Kang, Seong-Kyu;Lee, So Yun;Ham, Seunghon
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.5
    • /
    • pp.555-564
    • /
    • 2020
  • Objectives: To identify and investigate through qualitative and quantitative analysis the hazardous substances generated when compressed wood was burned at a live fire-training center. Methods: Four types of compressed wood that are actually used in live fire training were burned in a chamber according to KS F2271. The gaseous material was sampled with a gas detector tube and conventional personal samplers. Results: 1,3-butadiene, benzene, toluene, xylene, formaldehyde, hydrogen chloride, hydrogen cyanide, ammonia, carbon monoxide, and nitric acid were detected. In particular, 1,3-butadiene (497.04-680.44 ppm), benzene (97.79-125.02 ppm), formaldehyde (1.72-13.03 ppm), hydrogen chloride (4.71-15.66 ppm), hydrogen cyanide (3.64-8.57 ppm), and sulfuric acid (3.85-5.01 ppm) exceeded the Korean Occupational Exposure Limit as measured by sampling pump according to the type of compressed wood. Conclusions: We found through the chamber testing that firefighters could be exposed to toxic substances during live fire training. Therefore, firefighter protection is needed and more research is required in the field.

Preparation of an Inorganic Scintillator Loaded Film for the Measurement of Surface Contamination and its Performance Test (표면오염 측정용 무기섬광 함침 필름의 제조 및 성능 평가)

  • 서범경;이근우;임난주;박진호;한명진
    • Journal of Energy Engineering
    • /
    • v.13 no.2
    • /
    • pp.93-100
    • /
    • 2004
  • The smear media possible to sampling and radiation detection was prepared and evaluated for the surface contamination using indirect method. The films were made by impregnating Cerium Activated Yttrium Silicate (CAYS) in a polysulfone membrane. The membranes used solution as a dimethylformamide (DMF) and methylene chloride (MC), polysulfone as a polymer matrix and CAYS as a inorganic scintillator. The proximity membranes were prepared with single- and double-layered structure. The solidified methods were immersion to the nonsolvent bath such at water and ethanol and solvent evaporation. The measurement of the photon produced by interaction with radiation and inorganic scintillator used a photomultiflier tube (PMT), amplifier, and counter. In the comparison with the low background alpha/beta counter, the counter rate using inorganic scintillator proximity membrane for the $\^$14/C surface contamination was about 50%. Also. the $^3$H counting results revealed that the prepared membranes were efficient to monitor the surface contaminated with the low energy be-ray emitter nuclides.

PAHs Formation Characteristics and Fullerenes $(C_{60},\;C_{70})$ Synthesis in a Low-Pressure $C_6H_6/Ar/O_2$ Flame (저압 $C_6H_6/Ar/O_2$ 화염에서 PAHs 생성 특성 및 플러렌$(C_{60},\;C_{70})$ 합성에 대한 연구)

  • Lee, G.W.;Kim, Y.W.;Hwang, J.;Jrung, J.;Choi, M.
    • Journal of the Korean Society of Combustion
    • /
    • v.7 no.4
    • /
    • pp.36-44
    • /
    • 2002
  • Carbon molecules with closed-cage structures are called fullerenes $(C_{60},\;C_{70})$, whose applications include super-conductors, sensors, catalysts, optical and electronic device, polymer composites, and biological and medical materials. The synthesis of fullerenes has been recently studied with low-pressure benzene/argon/oxygen flames. The formation of fullerene is known as molecular weight growth processes of PAHs (polycyclic aromatic hydrocarbon). This study presents results of PAHs and fullerene measurements performed in a low-pressure benzene/argon/oxygen normal co-flow laminar diffusion flame. Through the central tube of the burner, benzene vapors carried by argon are injected. The benzene vapors are made in a temperature-controlled bubbler. The burner is located in a chamber, equipped with a sampling system for direct collection of condensable species from the flame, and exhausted to a vacuum pump. Samples of the condensable are analyzed by HPLC (High Performance Liquid Chromatography) to determine the yields of PAHs and fullerene. Also, we computed mole fraction of fullerene and PAHs in a nearly sooting low pressure premixed, one-dimensional benzene/argon/oxygen flame (equivalence ratio ${\Phi}=2.4$, pressure=5.33kPa). The object of computation was to investigate the formation mechanism of fullerenes and PAHs. The computations were performed with CHEMKIN/PREMIX. As a result of this study, fullerenes were synthesized in a low pressure (20torr) $C_6H_6/Ar/O_2$ flames and the highest concentration of fullerene was detected just above the visible surface of a flame.

  • PDF