• Title/Summary/Keyword: Sampler

Search Result 878, Processing Time 0.037 seconds

RELIABILITY ESTIMATION OF A MIXTURE EXPONENTIAL MODEL USIGN GIBBS SAMPLER

  • Kim, Hee-Cheul;Kim, Pyong-Koo
    • Journal of applied mathematics & informatics
    • /
    • v.6 no.2
    • /
    • pp.661-668
    • /
    • 1999
  • Reliability estimation using Gibbs sampler considered for modeling mixture exponential reliability problems. Gibbs sampler is developed to compute the features of the posterior distribution. Bayesian estimation of complicated functions requires simpler esti-mation techniques due to the mathematical difficulties involved in the Bayes approach. The Maximum likelihood estimator and the Gibbs estimator of reliability of the system are derived. By simula-tion risk behaviors of derived estimators are compared. model de-termination based on relative error is considered. A numerical study with a simulated data set is provided.

The measurement of NH$_3$ spatial distribution around the landfill site using the passive sampler (Passive sampler를 활용한 매립지 내ㆍ외부의 암모니아 공간분포 측정)

  • 이범진;김학민;김선태;정의석
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.319-320
    • /
    • 2001
  • Passive sampler는 현장에서 제약 없이 사용할 수 있다는 간편성과 그 측정결과의 정확성, 정밀성에 대하여 입증된 바 있는 측정도구로써 대기질 측정 및 모니터링뿐만 아니라 최근에는 대기확산모델의 검증자료로도 활용되고 있다(김선태, 2001). 이러한 측정방법은 국내의 경우 1992년 이후 한정적으로 사용되었으나, 최근에는 국내뿐 아니라 해외에서도 passive sampler를 사용하는 사례가 증가하고 있으며, UNEP에서도 다양한 목적으로의 활용성을 언급하고 있다(UNEP, 1994). (중략)

  • PDF

Hydraulic Experiments on the Measuring Equipments of Ronoff and Soil Loss (유출수 및 유실토량 측정장치에 관한 수리시험)

  • 유한열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.10 no.1
    • /
    • pp.1377-1387
    • /
    • 1968
  • In order to measure runoff and soil losses produced in a small test plot during rainfall, it is usually insufficient to use a tank only, necessitating the combined use of a main tank and a subsidiary tank. Accordingly. exact measurement largely depends on how to connect those two measuring tanks. The main purpose of this thesis is to improve the connecting parts of two measuring tanks so as to assure exact measurement of runoff and soil losses. In this experiment, two types of main tank, i. e. A-type and B-type, were used. A-type is a square tank having a flume at its end. At the flume, ten apertures are provided by using metal columns so as to be able to catch one tenth of total muddy flow discharging at the end of the flume, One tenth of total flow is led to the subsidiary tank through a slot sampler fixed to an aperture. B-type differes in that its flume does not have apertures and slot sampler is fixed directly to the end of the flume, other features being the same as those of A-type. Discharge volumes were measured by using weighing tanks and compared. The effect of baffle screen provided in the flume was also observed in connection with exact measurements. In order to keep main tank and its flume in a horizontal position, bolts and nuts mechanism was used. Vertical and horizontal screens were provided in the main to prevent coarse sands coming into the flume. The conclusion derived through this experiment is as follows: (1) The discharge through slot sampler at each aperture is almost the same for A-type. However, it is slightly more than one tenth of total discharge volume. (2) In case that baffle screen is provided in the flume of A-type tank, the discharge volume of slot sampler is less than that of the same type without screen. (3) For B-type tank, slot sampler discharge increases as slot sampler nears toward the center of flume. (4) When baffle screen is provided in the flume of B-type, slot sampler discharge is less than that of the same type without screen, and this phenomenon is more apparent as compared with A-type. (5) In case that the slot width of slot sampler for B-type is one inch, slot sampler discharge exceeds one tenth of total discharge volume. (6) When the slot width for B-type is 15/16 inch and slot sampler is fixed 3/8 inch apart from either flume wall, slot sampler discharge is approximately equal to one tenth of total discharge volume.

  • PDF

Development of a Sampler that Minimizes Sample Disturbance and Review of its Applicability (인발시 시료이탈을 최소화한 불교란시료 채취 샘플러 개발 및 적용성 검토)

  • Kim, Jongkwan;Han, Jin-Tae;Park, Ka-hyun;Shin, Hyu-Soung;Zhuang, Li;Yeom, Sun;Kim, Ki-Seog
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.3
    • /
    • pp.17-27
    • /
    • 2023
  • In order to accurately determine soil characteristics, it is necessary to collect undisturbed samples, and it is important to collect these samples with minimal disturbance. In this study, a sampler that minimizes sample disturbance was developed by attaching a catcher to the tip, and its applicability was reviewed through in situ sampling, X-ray CT, and laboratory tests. Results confirmed that horizontal cracks are likely to occur when using the Shelby tube sampler, whereas these cracks can be suppressed when using the newly developed sampler. Moreover, consolidation and shear test results showed that the samples collected using the newly developed sampler showed higher maximum shear strength compared to those collected using the Shelby tube sampler.

Reliability of the Mixture Model with Gamma Family Using Gibbs Sampler (깁스추출법을 이용한 감마족 신뢰확률 혼합모형에 대한 연구)

  • 김평구
    • Journal of Korean Society for Quality Management
    • /
    • v.27 no.1
    • /
    • pp.80-90
    • /
    • 1999
  • In this paper, reliability estimation using Gibbs sampler is considered for the mixture model with Gamma family, Gibbs sampler is derived to compute the features for the posterior distribution. By simulation study, the maximum likelihood estimator and the Gibbs estimator are obtained. A numerical study with a simulated data is provided.

  • PDF

A New Development of Large Diameter Sampler and Its Applicability (대구경 Sampler의 개발 및 적용성에 관한 연구)

  • 한영철
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.331-336
    • /
    • 1999
  • A great deal of attention has been given in recent years to large diameter specimen for evaluation of soft soil characteristics, and many studies and developments of the apparatus for obtaining large diameter undisturbed soil samples are in progress attempting to minimize the disturbance of samples for precise strength and consolidation tests in the laboratory. This paper introduces a new large diameter sampler(over 300mm diameter), which can take prefectly undisturbed sampling at any depths applying a new sampling technique. By comparing the results of consolidation tests it is shown that the samples obtained by this new apparatus are of a superior quality to that of samples obtained by conventional sampler(Nx, 75mm dia.) at the same depths.

Sampling and Analysis of Particles Generated in CSS-Mode of a Hard Disk Drive by Using a Particle Sampler (입자 샘플러를 이용한 하드디스크 CSS 동작 시 발생한 입자 샘플링 및 분석)

  • Lee Jae ho;Lee Dae Young;Kim Sang Yoon;Hwang Jung ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.5 s.236
    • /
    • pp.599-608
    • /
    • 2005
  • Controlling particle contamination is important to increase storage capacity as the flying height of a slider in a hard disk drive decreases. Since precise detection and analysis of particles are primary steps of particle control in a HDD, many researchers have used sampling methods. In this paper, we newly designed a particle sampler and conducted performance evaluation of the sampler. Also, we conducted particle sampling from the HDD using the particle sampler and analysis of sampled particles by SEM and AES. Experimental results show that the particles generated by the slide-disk interaction mainly came from the disk surface.

Posterior density estimation of Kappa via Gibbs sampler in the beta-binomial model (베타-이항 분포에서 Gibbs sampler를 이용한 평가 일치도의 사후 분포 추정)

  • 엄종석;최일수;안윤기
    • The Korean Journal of Applied Statistics
    • /
    • v.7 no.2
    • /
    • pp.9-19
    • /
    • 1994
  • Beta-binomial model, which is reparametrized in terms of the mean probability $\mu$ of a positive deagnosis and the $\kappa$ of agreement, is widely used in psychology. When $\mu$ is close to 0, inference about $\kappa$ become difficult because likelihood function becomes constant. We consider Bayesian approach in this case. To apply Bayesian analysis, Gibbs sampler is used to overcome difficulties in integration. Marginal posterior density functions are estimated and Bayesian estimates are derived by using Gibbs sampler and compare the results with the one obtained by using numerical integration.

  • PDF

Characteristic comparison of Andersen and total suspended particulate samplers in a particulate matter generation chamber (입자 발생 챔버를 이용한 Andersen과 총분진 시료채취기의 특성 비교)

  • Park, Ju-Myon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.3
    • /
    • pp.177-184
    • /
    • 2008
  • The purpose of this study was to compare the performance characteristics of Andersen and total suspended particulate (TSP) samplers in terms of particle size distribution (PSD) and mass sampling efficiency. In the present study, two Andersen and four TSP samplers were selected and tested to quantitatively estimate human exposure to fly ash representing industrial particulate matter (PM) in a carefully controlled chamber. The PSD characteristics, a mass median aerodynamic diameter and a geometric standard deviation, were found from the sampled PM of airborne samplers in the chamber. An Andersen sampler was compared with a TSP sampler quantified by a coulter counter multisizer, as a reference sampler, to describe the correlation of mass sampling efficiencies between two types of samplers. Overall results indicate that Andersen samplers overestimated small PM due to particle bounce phenomena between impaction stages. There was reasonably good correlation ($R^2$ = 0.89 and 0.91) between the mass sampling efficiencies of Andersen and TSP samplers during the two tests. However, the lower values of slope (0.71 and 0.72) in two tests showed that the Andersen sampler underestimated PM (> AD $10.1\;{\mu}m$) with sufficient inertia due to a relatively lower Andersen inlet velocity at 0.8 m/s comparing with the operating air velocity at 2.1 m/s in the sampling zone of a chamber.

Air Quality Evaluation with Passive Samplers for Large Cities (Passive Sampler를 이용한 대도시의 대기질 평가)

  • Jeon, Eui-Chan;Kim, Shin-Do;Choi, Kum-Chan
    • Journal of Environmental Impact Assessment
    • /
    • v.7 no.2
    • /
    • pp.83-88
    • /
    • 1998
  • Filter badge type sampler has not been widely used to evaluate air quality over large cities in Korea while it can be successfully used for multi-point sampling and analysis. We evaluated the passive sampler as a new tool to monitor air quality over large cities. We latticed Metropolitan Seoul into $2{\times}2Km$ to give 136 points. $NO_2$ concentrations were measured at all the points in the Spring and Summer of 1997. According to the passive sampler data, natural green zones generally recorded lower $NO_2$ concentrations than major streets and traffic congestion areas. Passive samplers with abundant 136 points gave more detailed picture of $NO_2$ distribution while auto-monitoring network did not clearly provide the characteristics of local land use. Also, passive samplers gave 15% higher values than auto-monitoring network. The correlation between the two values appears very high judging from the regression slope of 0.92 and correlation coefficient of 0.91. This study clearly demonstrates the effectiveness of the passive sampler as a tool to monitor air quality over large cities.

  • PDF