• Title/Summary/Keyword: Sample case

Search Result 2,431, Processing Time 0.026 seconds

A Study on Pyroelectric Characteristics of PZN-PT-PZ Ceramics (PZN-PT-PZ계 세라믹의 초전특성에 관한연구)

  • 박정철;전용우;소대화
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.46-50
    • /
    • 1996
  • In this paper, xPb(Zn$\_$1/3/Nb$\_$2/3/)O$_3$-yPbTiO$_3$-zPbZrO$_3$-zPbZrO$_3$ (0.5wt%)MnO$_2$ ceramics were fabricated by the mixed oxide method sintered at 1250$^{\circ}C$ for 2[hrs] and then the dielectric and pyroelectric properties were investigated. In 0.10PZN-0.45PT-0.47PZ sample, dielectric constant was 829 and in the case of 01.5PZN-0.45PT-0.40PZ sample, pyroelectric current and pyroelectric coefficient were 0.95 x 10$\^$-7/ [A] and 7.6 x 10$\^$-1/ [C/$\textrm{cm}^2$$.$$^{\circ}C$]. Figure of merits of pyroelectric current and voltage and detectivity, in same sample, has shown good properties, that were 2.4 x 10$\^$-8/[C$.$cm/J], 5.5 x 10$\^$-11/[C$.$cm/J], 1.6 x 10$\^$-8/ [C$.$cm/J].

  • PDF

Reliability Design of the Natural frequency of a System based on the Samples of Uncertain Parameters (불확실한 인자 표본을 이용한 시스템 고유진동수의 신뢰성 설계)

  • Choi, Chan Kyu;Yoo, Hong Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.467-471
    • /
    • 2014
  • The natural frequencies of a mechanical system are determined by the system parameters such as masses and stiffness of the system. Since material irregularities and manufacturing tolerances always exist in most of practical engineering situations, the system parameters always have uncertainties. As the uncertainties of the parameters increase, the uncertainties of the system natural frequencies also increases. Then, the reliability of the system deteriorates. So, the uncertainty of the system natural frequencies should be analyzed accurately and considered in the design of the system. In order to analyze the uncertainty of the system natural frequencies employing most of existing uncertainty analysis methods, the probability distributions of the uncertain system parameters should be identified. In most practical situations, however, identification of the probability distributions is almost impossible because of limited time and cost. For that case, the reliability should be estimated based on finite samples of the system parameters. In this paper, sample based reliability estimation method employing extreme value theory was proposed. Using the proposed estimation method, sample based reliability design of the system natural frequencies was conducted.

  • PDF

Carbonization Characteristics of Phenolic Resin Deteriorated by Tracking (트래킹에 의해 열화된 페놀수지의 탄화 특성)

  • 송길목;최충석;노영수;곽희로
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.1
    • /
    • pp.1-7
    • /
    • 2004
  • This paper describes the carbonization characteristics of a phenolic resin deteriorated by tracking under the environment of a fire. In the experiment, a liquids droplet of 1[%] NaCl was dripped on the phenolic resin to cause a tracking with 110[V], 220[V] voltages applied. It can be addressed from the experimental results that when an insulator is carbonized by an external fire, its structure is amorphous. If an insulator is carbonized by electrical cause, on the other hand, its structure would be crystalline. In order to observe the surface change of the phenolic resin, the tracking process was analyzed by using SEM. In the case that the materials are carbonized under heat or fire, the exothermic peak appears around 500[$^{\circ}C$]. This is one of the important factors to determine the cause of fires. As a result of DTA, the exothermic peaks of an untreated sample showed at 333.4[$^{\circ}C$], 495.7[$^{\circ}C$] but those of a sample deteriorated by tracking appeared at 430.6[$^{\circ}C$], 457.6[$^{\circ}C$] in a voltage of 110[V], and at 456.2[$^{\circ}C$], 619.7[$^{\circ}C$] in a voltage of 220[V]. It is possible, therefore, to distinguish a virgin sample from carbonized samples(graphite) by the exothermic peak.

Analyzing the Difference between the Stated Preference and the Revealed Preference before/after the High-speed Rail Service in Korea

  • Lee, Jang-Ho
    • International Journal of Railway
    • /
    • v.7 no.1
    • /
    • pp.24-33
    • /
    • 2014
  • The Korean high-speed rail (HSR) began its commercial service in 2004. This service has been created significant changes in the system of intercity passenger travels of Korea. However, the actual ridership was approximately half of the estimated one in the planning stage. In this background, this paper presents the difference between the stated preference (SP) before the HSR service and the revealed preference (RP) after it using the intercity travel mode choice models. Several meaningful differences are found in terms of the factors affecting the travel mode choice, the estimation results of model, the monetary values of time, and elasticities. While the access/egress travel time of high-speed rail is less important than in-vehicle travel time in the SP sample, they have same weight in the RP sample. Also the RP models show that the probability of choosing HSR can be decreased by the increase of the number of vehicles in household contrary to the results from the SP models. The monetary values of travel time are relatively high and the direct and cross elasticities in response to changes in level-of-service of HSR are relatively low in the RP sample. This Korean case is expected to offer referable material for preparing high-speed rail services in other countries by showing the difference between the SP and RP before/after the actual service, identifying the importance of access/egress travel time and lower direct elasticities of HSR demand.

A study on the longitudinal physique of children-centered on sampling physique group and general physique group (아동체격의 종단적 연구)

  • 정옥임
    • Journal of the Ergonomics Society of Korea
    • /
    • v.6 no.2
    • /
    • pp.3-8
    • /
    • 1987
  • In order to secure reliable values of measurement of the data about children's longitudinal develop- ment and physique examination and their growth states for 6 years from first grade through sixth grade in elementary school was collected based on their school health records. A sample physique group and general physique group were investigated and compared classified into girls and boys. The results are as follows; (1) Whe the difference of physiques in the sample group and general group is compared, boys and girls show little difference in height but boys differ greatly in weight and sitting-height but girls do in weight, girth of chest and sitting-height between 8 and 11 years old. (2) In the verification of the two groups; the body height in 7 years old show a significant difference at the P<0.5 level and their weights do at 7.8 and 11 years old. Girls' sitting-height at 11 years old shows a significant difference at the P<0.5 level. In the light of the above results because possibility of instrumental error in measurement is high between the two groups and also in case of the comparison of past sample data, the physique examination used in every school seems to be in need of reconsideration to reduce errors in measurement.

  • PDF

Study on Performance and Aging Test of Porcelain Insulators for Transmission Line (송전용 자기재 애자의 성능평가 및 가속열화시험)

  • 한세원;조한구;박기호;이동일;최인혁
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.9
    • /
    • pp.842-850
    • /
    • 2003
  • The suspension insulators are subjected to harsh environments in service for a long time. The long-term reliability of tile insulators is required for both mechanical and electrical performances. This study describes some basic performance tests and accelerated aging test by cool-heat cycling methods and thermal mechanical performance test methods on alumina porcelain insulators (new and aged) used for transmission line in KOREA. There was no fail in electrical and mechanical performance tests such as a high voltage strength, a flashover voltage, and an impact strength in all samples. But in the case of accelerating aging tests which have above 9$0^{\circ}C$ temperature gradient, fracture phenomena was happened by a thermal shock in tile aged sample(sample A) with low alumina porcelain body. It was indicated that sample A was more severely aged than other samples. According to results of HRB test and microstructural analysis, it was reasoned that insulator bodies with the matrix reinforced with alumina crystalline phase have advantages over the suppression of crack advance. And cool-heat aging and mechanical thermal ageing tests shows that a temperature gradient is more effective to accelerating than a cycling number.

A Study on the Nucleus System of Standard Hospitals in U.K. (영국의 표준병원에서 뉴클리우스 시스템에 대한 연구)

  • Moon, Chang-Ho
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.3 no.4
    • /
    • pp.59-68
    • /
    • 1997
  • This study is intended to review the Nucleus System of standard hospitals in U.K. The research is focused on the theoretical background, contents of Nucleus System, and the operational problems through the survey of sample hospitals. The contents of research include the development history of standardization, outlines, aimes, advantages, the data of Nucleus system, and the study-visits of sample hospitals. The conclusion could be summarized as follows ; 1) The form of standard hospitals is compact and low-rise the major movements are horizontal. The standard plans of the functional dpartments are unified as cruciform with $15m{\times}15m$ module. 2) The Nulceus System has been developed. The hospitals have 3 stories maximum and courtyards for natural light & ventilation. 3) The advantages of Nucleus System includes reduction of design & construction period, the buildability due to the repetitive construction, and the running cost. And the disadvantages are mentioned as the lack of storage, staff accomodation, pantry, and sanitary facilities. 4) Sample hospitals provide human scale, possibilities of growth & change, and curing environment from art decoration & artificial lake. 5) In case of Korean situation, even the minimum standardization such as hospital design guidelines should be developed in near future.

  • PDF

Electrostatic Electrification Properties of Silicone Rubber due to Al Ratios (Al 비율에 실리콘 고무의 정전기 대전 특성)

  • Lee, Sung-Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.8
    • /
    • pp.522-527
    • /
    • 2014
  • In this study, using the silicone rubber sample of $4cm{\times}4cm{\times}0.1cm$ for low voltage cable, the electrostatic electrification properties of three samples that the conductive Al of 0%, 25%, and 50% is attached to the surface of sample was measured. The following conclusion was obtained through this experiment. 1) In case of the sample which has the Al area of 50%, the higher the humidity to 90% in the temperature of $10^{\circ}C$, the electrostatic electrification voltage was reduced about 0.25 kV to 0.02 kV, and it confirmed that the electrostatic electrification voltage was in constant about 0.02 kV in the temperature over $20^{\circ}C$. 2) Increasing the Al area of samples of 0%, 25%, and 50% in temperature of $10^{\circ}C$, it confirmed that the electrostatic electrification voltage was reduced by about 2.67 kV, 2.02 k, 0.21 kV. 3) This study shows that the conductor, followed by temperature and humidity affects the electrostatic electrification voltage.

Treatment of Landfill Leachate by UV/TiO2/H2O2 System (UV/TiO2/H2O2 시스템을 이용한 매립지(埋立地) 침출수(浸出水) 처리(處理))

  • Kim, Sung-Joon;Moon, Jung-Uye
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.4
    • /
    • pp.133-141
    • /
    • 1997
  • In order to treat the landfill leachate, $UV/TiO_2/H_2O_2$ system connected with biological treatment was investigated, and proper pretreatment methods were examined to reduce the load on the system considering economical and technical efficiency. It was more profitable to put $H_2O_2$ into the system in the early stage for the sample which was treated with $H_2SO_4$ to decrease alkalinity and with $FeCl_3-6H_2O$ flocculation. Because the required reaction time run up by increasing $H_2O_2$ input amount, though the COD was reduced slightly, the optimal $H_2O_2$ input amount should be determined for the desired COD and the economical efficiency. The appropriate way to get the lowest COD in the shortest time was the method to treat the sample which was controlled to pH 3.5 after adjusting to pH 12 and put 500 ppm $H_2O_2$ into the system. In that case, to increase $H_2O_2$ input amount was not profitable for the system efficiency. The sufficient photocatalytic excited time was required to reduce the photocatalytic decomposition time for the sample which was gone through the alkali state.

  • PDF

Performance Analysis of Frequency Synchronization for HDR-WPAN System (HDR-WPAN 시스템을 위한 주파수 동기 성능분석)

  • Park, Ji-Woo;Kang, Hee-Gok;Kim, Jae-Young;Oh, Chang-Heon
    • Journal of Advanced Navigation Technology
    • /
    • v.8 no.2
    • /
    • pp.163-168
    • /
    • 2004
  • In this paper, we propose a frequency synchronization algorithm using characteristic of CAZAC sequence for HDR-WPAN and analyze the performance by signal constellation and EVM(error vector magnitude). The proposed frequency offset technique estimated each sample phase error of two sequences among 12 CAZAC sequences which have excellent autocorrelated characteristic. Estimated phase error is multiplied to each sample of next sequence for compensating the frequency offset. The remaining frequency offset after compensating it with two sequences has maximum 0.002 offsest ranges at each sample. The computer simulation proved that the permission of EVM value had satisfied in the case of DQPSK at 20[dB].

  • PDF