• Title/Summary/Keyword: Sakarya

Search Result 118, Processing Time 0.028 seconds

The Predictive Strength of Students' Self-Efficacy, Problem Solving Skills to Perform Catheter Care

  • Dogu Kokcu, Ozlem;Cevik, Celalettin
    • Journal of Korean Academy of Nursing
    • /
    • v.50 no.3
    • /
    • pp.411-418
    • /
    • 2020
  • Purpose: The aim of this study was to determine the predictive strength of students' self-efficacy, problem-solving skills, and other characteristics in performing intravenous practices and monitor phlebitis and infiltration. Methods: This cross-sectional study was carried out with 736 third and fourth-year students studying at the Health Sciences Faculties of Balikesir and Sakarya universities. The data were collected using the Self-Efficacy Scale, Problem-Solving Inventory and Catheter Care and Infiltration Monitoring Questionnaire. Results: The participants' mean Catheter Care and Infiltration Monitoring Questionnaire score significantly and positively correlated with their mean Self-Efficacy Scale score on a moderate level (r=.25; p<.001) but significantly and negatively correlated with their mean Problem-Solving Inventory score on a moderate level (r=-.21; p<.001). In other words, because a low Problem-Solving Inventory score indicates that the person's problem-solving skill is high, the Care and Infiltration Monitoring Questionnaire score increased as the problem-solving skill increased. While the Self-Efficacy Scale predicted the year of study and catheter care and infiltration monitoring variables positively, the Problem-Solving Inventory predicted the satisfaction with the profession variable negatively. Conclusion: Self-efficacy, problem-solving, liking the profession, and year of study predict success in catheter care and infiltration monitoring. For this reason, guidance may be provided in the development of a comprehensive education system toward increasing students' problem-solving skills, self-efficacy, and professional knowledge and skills.

In-situ measurement of railway-traffic induced vibrations nearby the liquid-storage tank

  • Goktepe, Fatih;Kuyuk, Huseyin S.;Celebi, Erkan
    • Earthquakes and Structures
    • /
    • v.12 no.5
    • /
    • pp.583-589
    • /
    • 2017
  • In this study, result of a field investigation of railway traffic-induced vibrations is provided to examine acceptability levels of ground vibration and to evaluate the serviceability of a liquid-storage tank. Free field attenuation of the amplitudes as a function of distance is derived by six accelerometers and compared with a well-known half-space Bornitz's analytical solution which considers the loss of the amplitude of waves due to geometrical damping and material damping of Rayleigh. Bornitz's solution tends to overlap vertical free field vibration compared with in-situ measured records. The vibrations of the liquid-storage tank were compared with the USA, Federal Transportation Railroad Administration (FTA) criteria for acceptable ground-borne vibrations and with the criteria in DIN 4150-3 German standard. Comparing the thresholds stated in DIN 4150-3, absolute peak particle velocities are within the safe limits, however according to FTA velocity level at the top of the water tank exceeds the allowable limits. Furthermore, it is intended to indicate experimentally the effect of the kinematic interaction caused by the foundation of the structure on the free-field vibrations.

Simultaneous dry-sorption of heavy metals by porous adsorbents during sludge composting

  • Ozdemir, Saim;Turp, Sinan Mehmet;Oz, Nurtac
    • Environmental Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.258-265
    • /
    • 2020
  • Heavy metal removal by using porous mineral adsorbents bears a great potential to decontaminate sludge compost, and natural zeolite (NZ), artificial zeolite (AZ), and expanded perlite (EP) seem to be possible candidates for this purpose. A composting experiment was conducted to compare the efficiency of those adsorbents for removal of iron (Fe), manganese (Mn), chromium (Cr), copper (Cu), zinc (Zn), nickel (Ni), and lead (Pb) from sewage sludge compost with no adsorbent amendment. For this purpose, 10 g of NZ and AZ and 5 g of EP was filled in a small bag made from non-biodegradable synthetic textile and was separately mixed in composting piles. The bags were separated from compost samples at the end of the experiment. AZ and NZ exhibited different reduction potentials depending on the type of heavy metal. AZ significantly reduced Cr (43.7%), Mn (35.8%), and Fe (29.9%), while NZ more efficiently reduced Cu (24.5%), Ni (22.2%), Zn (22.1%), and Pb (21.2%). The removal efficiency of EP was smaller than both AZ and NZ. The results of this simultaneous composting and metal removing study suggest that AZ and NZ can efficiently bind metal during composting process.

GENERALIZED LUCAS NUMBERS OF THE FORM 5kx2 AND 7kx2

  • KARAATLI, OLCAY;KESKIN, REFIK
    • Bulletin of the Korean Mathematical Society
    • /
    • v.52 no.5
    • /
    • pp.1467-1480
    • /
    • 2015
  • Generalized Fibonacci and Lucas sequences ($U_n$) and ($V_n$) are defined by the recurrence relations $U_{n+1}=PU_n+QU_{n-1}$ and $V_{n+1}=PV_n+QV_{n-1}$, $n{\geq}1$, with initial conditions $U_0=0$, $U_1=1$ and $V_0=2$, $V_1=P$. This paper deals with Fibonacci and Lucas numbers of the form $U_n$(P, Q) and $V_n$(P, Q) with the special consideration that $P{\geq}3$ is odd and Q = -1. Under these consideration, we solve the equations $V_n=5kx^2$, $V_n=7kx^2$, $V_n=5kx^2{\pm}1$, and $V_n=7kx^2{\pm}1$ when $k{\mid}P$ with k > 1. Moreover, we solve the equations $V_n=5x^2{\pm}1$ and $V_n=7x^2{\pm}1$.

Mechanical Behaviour of Non-Oxide Boride Type Ceramics Formed on The AISI 1040 Plain Carbon Steel

  • Sen, Saduman;Usta, Metin;Bindal, Cuma;UciSik, A.Hikmet
    • The Korean Journal of Ceramics
    • /
    • v.6 no.1
    • /
    • pp.27-31
    • /
    • 2000
  • A series experiments were performed to evaluate mechanical behavior of non-oxide boride type ceramics formed on the AISI 1040 plain carbon steel. Boronizing was performed in a slurry salt bath consisting of borax, boric acid, and ferro-silicon at $950^{\circ}C$ for 2-6h. The AISI 1040 steel used as substrate material was containing 0.4%C, 0.13%Si, 0.65%Mn, 0.02%P, 0.014%S. The presence of non-oxide boride type ceramics $Fe_2B $ and FeB formed on the surface of steel was confirmed by metallographic technique and X-ray diffraction (XRD) analysis. The hardness of borides measured via Vickers indenter with a load of 2N reached a microhardness of up to 1800 DPN. The hardness of unborided steel was 185 DPN. The fracture toughness of borides measured by means of Vickers indenter with a load of 10N was about 2.30 MPa.$m^{1/2}$. The thickness of boride layers ranged from 72$\mu\textrm{m}$ to 145$\mu\textrm{m}$. Boride layers have a columnar morphology.

  • PDF

Numerical determination of crack width for reinforced concrete deep beams

  • Demir, Aydin;Caglar, Naci
    • Computers and Concrete
    • /
    • v.25 no.3
    • /
    • pp.193-204
    • /
    • 2020
  • In the study, a new, simple and alternative formula is proposed to calculate numerically crack widths of concrete on a finite element (FE) model. By considering more general tension softening behavior of concrete, the proposed expression is derived irrespective of any tension softening model given in the literature or design codes. The test results of six reinforced concrete (RC) deep beams having different geometrical and material properties selected from a recent existing experimental study of the authors are used to verify the accuracy and reliability of the proposed formula and the created numerical FE models of the specimens. Moreover, the crack width results obtained from the FE models are compared with the test results to see the performance of the proposed formula. The results of the study demonstrate that the proposed formula gives very accurate results in a comparison with the test results. The ratios of errors on the results stay commonly at an acceptable level as well. Consequently, the proposed formula is quite simple, unique, and robust to determine crack widths of RC deep beams on an FE model.

Histological analysis of acute toxicity of 2,4-diclorophenoxy acetic acid in ovary of zebrafish

  • Koc, Nazan Deniz;Akbulut, Cansu
    • Animal cells and systems
    • /
    • v.16 no.5
    • /
    • pp.400-407
    • /
    • 2012
  • Plant growth regulators are the chemicals that are found in plants and produced synthetically. In agricultural applications, plant hormones are used in minor quantities for fixing the problems. In our research, we studied the effects of 2,4 diclorophenoxyacetic acid (2,4D), which is an auxin used in agricultural applications. Auxins are the group that are used most popularly in plant growth regulators. In our study, different doses of 2,4 diclorophenoxyacetic acid are given to zebrafish, and ovarium tissues are observed histomorphologically. We generated one control and three experiment groups from the stock solution. The experiment was carried out in 20 liter capacity complete glass aquarium at $24{\pm}1^{\circ}C$ water temperature. After five days of application, fishes were dissected. Histomorphological changes of the ovarium were investigated under a light microscope. A decrease in the number of oocytes in zebrafish ovarium was observed when compared with the control group. Many deformed and underdeveloped oocytes were detected. An increase in the number of atretic oocytes was observed. It was deduced that acute doses of 2,4 diclorophenoxyacetic acid decelerates oogenesis in fishes.

Strengthening of hollow brick infill walls with expanded steel plates

  • Cumhur, Alper;Altundal, Adil;Aykac, Sabahattin;Aykac, Bengi
    • Earthquakes and Structures
    • /
    • v.11 no.5
    • /
    • pp.887-904
    • /
    • 2016
  • An efficient, economical and practical strengthening method for hollow brick infill walls was proposed and investigated in the present study, experimentally and numerically. This method aims at increasing the overall lateral strength and stiffness of the structure by increasing the contribution of the infill walls and providing the non-bearing components of the structure with the capability of absorbing earthquake-induced energy to minimize structural damage during seismic excitations. A total of eleven full-scale infill walls strengthened with expanded mild steel plates were tested under diagonal monotonic loading to simulate the loading condition of the non-bearing walls during an earthquake. The contact surface between the plates and the wall was increased with the help of plaster. Thickness of the plates bonded to both faces of the wall and the spacing of the bolts were adopted as test parameters. The experiments indicated that the plates were able to carry a major portion of the tensile stresses induced by the diagonal loads and provided the walls walls with a considerable confining effect. The composite action attained by the plates and the wall until yielding of the bolts increased the load capacities, rigidities, ductilities and energy-absorption capacities of the walls, considerably.

Multiple Primary Malignancies - A Retrospective Analysis at a Single Center in Turkey

  • Arpaci, Erkan;Tokluoglu, Saadet;Yetigyigit, Tarkan;Alkis, Necati
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.2
    • /
    • pp.769-773
    • /
    • 2013
  • Background: A literature review on 1,104,269 cancer patients concluded that the prevalence of multiple primary malignancies (MPM) is between 0.73% and 11.7%. MPMs seem to have higher incidence than that influenced by hazard only. The purpose of this study was to investigate clinically useful information for effective screening for synchronous and metachronous second primary cancers and to identify a potential surveillance protocol. Materials and Methods: Using statistical and epidemiological indicators we evaluated the patients with MPMs (double locations) admitted to Dr. Abdurrahman Yurtarslan Ankara Oncology Education and Research Hospital between 1981 and 2010. Results: Out of the 130 cases, 24 (18.4%) were synchronous while 106 cases (81.6%) were metachronous tumours. Mean interval time from first to second primary cancers was 4.65 years (0-27 years). The most frequent malignant associations were breast-breast, breast-endometrium and breast-ovary. Both primary and secondary tumors tended to be in an advanced stage explained by the low compliance of the patients to follow-up. Conclusions: The possibility that MPMs exist must always be considered during pretreatment evaluation. Screening procedures are especially useful for the early detection of associated tumors, whereas careful monitoring of patients treated for primary cancer and a good communication between patients and medical care teams should ensure early detection of secondary tumors, and subsequent appropriate management.

isMAC: An Adaptive and Energy-Efficient MAC Protocol Based on Multi-Channel Communication for Wireless Body Area Networks

  • Kirbas, Ismail;Karahan, Alper;Sevin, Abdullah;Bayilmis, Cuneyt
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.8
    • /
    • pp.1805-1824
    • /
    • 2013
  • Recently, the use of wireless body area networks (WBAN) has been increasing rapidly in medical healthcare applications. WBANs consist of smart nodes that can be used to sense and transmit vital data such as heart rate, temperature and ECG from a human body to a medical centre. WBANs depend on limited resources such as energy and bandwidth. In order to utilise these resources efficiently, a very well organized medium access control (MAC) protocol must be considered. In this paper, a new, adaptive and energy-efficient MAC protocol, entitled isMAC, is proposed for WBANs. The proposed MAC is based on multi-channel communication and aims to prolong the network lifetime by effectively employing (i) a collision prevention mechanism, (ii) a coordinator node (WCN) selection algorithm and (iii) a transmission power adjustment approach. The isMAC protocol has been developed and modelled, by using OPNET Modeler simulation software. It is based on a networking scenario that requires especially high data rates such as ECG, for performance evaluation purposes. Packet delay, network throughput and energy consumption have been chosen as performance metrics. The comparison between the simulation results of isMAC and classical IEEE 802.15.4 (ZigBee) protocol shows that isMAC significantly outperforms IEEE 802.15.4 in terms of packet delay, throughput and energy consumption.