• Title/Summary/Keyword: Safety standard

Search Result 4,311, Processing Time 0.047 seconds

A Consideration of Installation Method of Debris Net and Horizontal Safety Net (낙하물 방지망 및 추락 방호망의 설치방법에 관한 고찰)

  • JI, Suk-Won;Chol, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.131-132
    • /
    • 2019
  • In the Public Notice No. 2019-15 of the Ministry of Employment and Labor, the safety net and regulations on them have been deleted. The performance criterion of the debris net, which also functions as a horizontal safety net in the regulations on the criteria of occupational safety and health, is unclear. When installing a debris net that also functions as a horizontal safety net, a net that meets the performance criteria of KS F 8082 must be installed in accordance with KOSHA C-31-2017. The Korean Standard Specification for Construction Works, which specifies debris net and horizontal safety net, should be revised as soon as possible.

  • PDF

A Study on the Technical Regulation of Brake System for Electrical Multiple Unit Safety (전동차 안전을 위한 제동장치의 기술기준에 관한 연구)

  • Lee, Woo-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1332-1334
    • /
    • 2003
  • Safety of breaking facility is very important in subway safety, especially in case of subway that many people used, breaking capability is connected directly with safety and capability of vehicle. Recently, direction of subway technical development is established as passenger's convenience and agreeableness. However, we are known importance of safety in subway through Dae-gu subway incendiary case. Subway accident not happen only fire, vehicle collisions or passenger's fall to the track can happen. In this case, safety standard of breaking facilities is very important. so this paper define safety of breaking facilities and take proper that standard.

  • PDF

A Study on the Death Accident Analysis of Ladder and Prevention Measures for Fall Accidents (산업현장 사다리 관련 사망재해 분석 및 추락재해 예방대책에 관한 연구)

  • Sim, Hyuon-Hwang;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.4
    • /
    • pp.95-104
    • /
    • 2017
  • Among the industrial disasters caused by drop, ladder related drop disasters are occurred the mostly. The victims are occurred continuously. This study analyzed current situation of industrial disasters for recent 10 years(2005~2014) and compared analyzed statistics of death disasters of ladder by workplace scale, age, occupation, employment type, working content, scarred area, etc. in detail. This study suggested direction of safety standard modification for ladder that is an original cause material of many drops, direction of safety training strengthening of small-scaled workplace, and safety model based on disaster statistics and should contribute to reduction of disaster rate for ladder working.

A Study on Safety Standards for the Interior of an Artillery Firing Range Considering Probable Error (공산오차를 고려한 국내 포병사격장 안전기준 분석 연구)

  • Juhee Kim;Kieun Sung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.139-148
    • /
    • 2023
  • Safety standards for long-range artillery ammunition test and training sites follow the US artillery shooting range safety zone standards. Although the South Korean geographical conditions of shooting ranges are different from those of the United States, there is no safety standard reflecting the South Korean topographical characteristics. Probable error associated with the shooting range, trajectory should be considered in establishing the safety standards. In this study, we present the safety standards for the ammunition testing site suitable for the Korean situation, with applying a concept of trajectory and probable error differed by ammunition type, which are currently confirmed by the South Korean Army's artillery shooting.

Development of Standard Checklist for Safety Management of Toxic Gas facility in Domestic University Laboratory (국내 대학 실험실 독성가스 시설의 안전관리를 위한 표준 체크리스트 개발)

  • Lee, Sungjin;Kim, Byung-Duk;Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.92-98
    • /
    • 2015
  • Toxic gases are managed by High Pressure Gas Safety Control Act. Toxic Gases are "31 designated species and each gas of which the permissible concentration($LC_{50}$) is equal to or less than 5000 ppm as defined in High Pressure Gas Safety Control Act.". Korean toxic gas usage in accordance with the growth of the electronic industry has increased explosively. The demand of toxic gas research in domestic university laboratories has grown together. But the research associated with toxic gas safety management in the domestic laboratory is nonexistent state. In this study, we identified weak points of toxic gas safety management through a survey of domestic university laboratory facilities. This paper presented toxic gas safety measures in order to overcome those weak points. Also this paper developed a standard checklist to improve and ensure safe management of toxic gas facility in accordance with the proposed measures. This research is to enforce safety management of toxic gas facilities in domestic university laboratory and it will provide safety guidelines for every laboratory.

A Study on the Standard of Test Method for Estimation of Usage Environment Safety and Performance of U-health Medical Device (유헬스케어의료기기의 사용환경 안전성 및 성능평가를 위한 표준시험방법 연구)

  • Park, S.K.;Cha, J.H.;Hur, C.H.;Park, K.J.;Moon, I.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.4 no.1
    • /
    • pp.9-14
    • /
    • 2010
  • According to graying of population and income enlargement of people, interest about U-Healthcare of new form fusing with IT technology are enlarged. Need a estimation technology and standard of test method for safety and performance considering usage environment of U-Healthcare medical device. In this research, developed the standard of test method for usage environment safety and performance of U-Healthcare medical device referring IEC standards and KS standards.

The Study on Choice Standard and Operation Method on Zone 30 in the Outskirts Street of Residential Area (주거지 주변가로 Zone 30 구역 선정기준 및 운영방안 연구)

  • Sim, Gwan-Bo;Go, Myeong-Su;Jo, Seong-Geun
    • Journal of Korean Society of Transportation
    • /
    • v.27 no.5
    • /
    • pp.39-49
    • /
    • 2009
  • This research analyzes current pedestrian's safety zone choice standard problem and described about correct standard re-thesis at real. About problem of pedestrian traffic accidents to specific item statistical data to basis ramification of pedestrian traffic accidents, occurrence type of accident, action type etc. synthetically analyze and mark pedestrian's safety zone by countermeasure for decrease of pedestrian traffic accidents and utilize operating domestic outer garment reward and drew domestic Zone30 zone choice standard. Also, because analyzing effect that traffic discharge and speed through on-the-spot probe get in pedestrian thinking, presented quantitative standard, and analyze accident special quality of back pedestrian traffic accidents occurrence number of item and so on do accident type beside quantitative standard, road function, accident latitude and present standard. Specially, take advantage of statistical data of traffic accidents and put emphasis in pedestrian safety. Also, because establishment standard about safety facility establishment of Zone30 zone and systematic thesis of operation way do not consist, standard guide of consistency it is no and does equipment that is established in Zone30 zone because confusion happens by each local unit presented establishment and operation way, and present Zone30 zone.

The stress positioning control method for slim CRTs glass design using FEM

  • Hwang, Yoing-Ik;Lee, Tae-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.1053-1057
    • /
    • 2007
  • One of the important roles of glass is safety guarantee in CRTs. It is working under high vacuum and has to be maintained continuously for the atmosphere pressure, humidity, and excitation etc,. This paper propose to CRTs glass design method via the stress positioning control for slim CRTs using FEM to ensure the national safety standard and newly demanded safety standard by CRTs set makers.

  • PDF