• Title/Summary/Keyword: Safety protection system

Search Result 1,053, Processing Time 0.025 seconds

Numerical Analysis on the Stress and Deformation Characteristics of LNG Membrane Storage Tank System with Corner Protection (코너프로텍션 설치에 따른 멤브레인 LNG 저장탱크 시스템의 응력 및 변형거동 특성에 관한 수치해석)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.6
    • /
    • pp.9-14
    • /
    • 2009
  • In this study, the stress and deformation characteristics of corner protection in which is fabricated in an insulation area have been analyzed using a finite element method. The proposed corner protection may increase the strength and leakage safeties of conventional LNG storage system. The stress and deformation of LNG storage tank system are computed for an insulation panel box, membrane inner tank, and prestressed concrete outer tank. The FEM computed results indicate that the stress and displacement of new membrane LNG tank system with a corner protection between an inner tank and an outer tank are reduced in comparison to those of a conventional membrane LNG tank. This is explained that the strength safety of LNG membrane tank system may be increased due to a strength stiffness of a corner protection.

  • PDF

A Study on the Integrated Control and Safety Management System for 9% Ni Steel LNG Storage Tank (9% 니켈강재식 LNG 저장탱크용 통합제어안전관리시스템에 관한 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.5
    • /
    • pp.13-18
    • /
    • 2010
  • This paper presents the development of an integrated control and safety management system for 9% nickel steel LNG storage tank. The new system added the measuring equipment of pressure, displacement and force compared to the conventional measurement and control system. The measured data has simultaneously been processed by integrating and analyzing with new control equipments and safety management systems. The integrated control and safety management system, which may increase a safety and efficiency of a super-large full containment LNG storage tank, added additional pressure gauges and new displacement/force sensors at the outer side wall and a welding zone of a stiffener and top girder of an inner tank, and the inner side wall of a corner protection tank. The displacement and force sensors may provide failure clues of 9% nickel steel structures such as an inner tank and a corner protection, and a LNG leakage from the inner tank. The conventional leak sensor may not provide proper information on 9% nickel steel tank fracture even though LNG is leaked until the leak detector, which is placed at the insulation area between an inner tank and a corner protection tank, sends a warning signal. Thus, the new integrated control and safety management system is to collect and analyze the temperature, pressure, displacement, force, and LNG density, which are related to the tank system safety and leakage control from the inner tank. The digital data are also measured from control systems such as displacement and force of 9% nickel steel tank safety, LNG level and density, cool-down process, leakage, and pressure controls.

SIS Design for Fuel Gas Supply System of Dual Fuel Engine based on Safety Integrity Level(SIL) (이중연료엔진의 연료가스공급시스템에 대한 안전무결도 기반 안전계장시스템 설계)

  • Kang, Nak-Won;Park, Jae-Hong;Choung, Choung-Ho;Na, Seong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.6
    • /
    • pp.447-460
    • /
    • 2012
  • In this study, the shutdown system of the fuel gas supply system is designed based on the Safety Integrity Level of IEC 61508 and IEC 61511. First of all, the individual risk($10^{-4}$/year) and the risk matrix which are the risk acceptance criteria are set up for the qualitative risk assessment such as the HAZOP study. The natural gas leakage at the gas supply pipe is identified as the highest risk among the hazards identified through the HAZOP study and as a safety instrumented function the shutdown function for leakage was defined. SIL 2 and PFD($2.5{\cdot}10^{-3}$) for the shutdown function are determined by the layer of protection analysis(LOPA). The shutdown system(SIS) carrying out the shutdown function(SIF) is verified and designed according to qualitative and quantitative requirements of IEC 61508 and IEC 61511. As a result of SIL verification and SIS conceptual design, the shutdown system is composed of two gas detectors voted 1oo2, one programmable logic solver, and two shutdown valve voted 1oo2.

Study on Pedestrian Protection device in collision using Pneumatic cylinder and simple link mechanism (공압 실린더 및 단순 링크기구를 이용한 충돌 보행자 보호 장치에 관한 연구)

  • Noh, S.H.;Lee, D.R.
    • Journal of Power System Engineering
    • /
    • v.12 no.4
    • /
    • pp.64-71
    • /
    • 2008
  • This study is on pedestrian protection device using pneumatic cylinder and simple link mechanism when vehicle collide with pedestrian. This study ensured the safety space between engine and hood after it applies to simple link mechanism and pneumatic cylinder. It can absorb the damage which measure the specific device if vehicle collide with pedestrian. Combination of simple link mechanism and pneumatic cylinder was more superior than the present pedestrian protection device. Simple link mechanism could confirm superior height and survival probability than when only cylinder operated. It also ensured enough space between engine and hood. And if a cylinder is not working because of old cylinder, poor repair or damage of accident vertical cylinder would be difficult to execute because there exists the irregular space between engine and hood. If simple link mechanism operates with only one cylinder it could ensure the regular space because simple link mechanism set up at the middle of hood. So this device could confirm high safety for pedestrian.

  • PDF

The Importance of Strengthening the Role of the Institutional Review Board and the Human Research Protections Program following the Revision of the Act on the Safety and Support of Advanced Regenerative Medicine and Advanced Biopharmaceuticals ('첨단재생의료 및 첨단바이오의약품 안전 및 지원에 관한 법률' 개정에 따른 '기관생명윤리위원회(Institutional Review Board)' 역할 및 '임상시험 및 대상자보호프로그램(Human Research Protections Program)' 강화의 중요성)

  • Byung Soo Kim
    • The Journal of KAIRB
    • /
    • v.6 no.1
    • /
    • pp.1-4
    • /
    • 2024
  • The strengthening of Institutional Review Board (IRB) and Human Research Protection Program (HRPP) for clinical research on advanced regenerative medicine reflecting the 3 Principles of the Belmont Report (Respect, Beneficence, Justice) is very important. The research institution IRB should naturally be in charge of managing the clinical research process. And it is crucial to reinforce HRPP for the protection of research subjects in institutions conducting advanced regeneration clinical research. So, it is needed to establish a Protection System for Advanced Regenerative Medical Research Subjects composed of clinical research management communication system for advanced regenerative medicine between KAIRB (Korean Association of IRB) of research institutes and National Management Agency for Advanced Regenerative Medical Research. In advanced regenerative medicine clinical research to verify safety and efficacy of the investigational drugs to the subjects with rare and incurable diseases rather than to treat the patients, it is hoped that a management system that guarantees the scientific characteristics of research and the rights of research subjects would be well organized and operated.

  • PDF

A Study on the Measurement and Determination of External Loop Impedance on TN-C-S System (TN-C-S 접지계통에서 외부 루프 임피던스의 실측 및 기준값 설정에 관한 연구)

  • Yi, Geon-Ho;Jung, Jin-Soo;Moon, Hyun-Wook;Kim, Sun-Gu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.8
    • /
    • pp.1163-1168
    • /
    • 2013
  • The maximum allowable value of loop impedance($Z_s$) to secure the operation of overcurrent protective devices and the safety for indirect contact is a very important in TN-C-S system. The loop impedance is divided into inner loop impedance which consumer can adjust and external loop impedance($Z_e$) which only electric operator can adjust. Thus, an external loop impedance which limits to less than a certain value is a very important factor for human body protection against electric shock in TN-C-S system. The concept of loop impedance($Z_s$) is recently introduced to the domestic, the study about external loop impedance is yet insufficient. However, the study about the reference impedance as specified by the IEC 60725 standard to improve the quality and reliability of the power supply is being made. In this paper, reference value of external loop impedance($Z_e$) to meet domestic environment will be proposed by the nationwide measurement and statistical analysis.

Development of a Computer Code for Low-and Intermediate-Level Radioactive Waste Disposal Safety Assessment

  • Park, J.W.;Kim, C.L.;Lee, E.Y.;Lee, Y.M.;Kang, C.H.;Zhou, W.;Kozak, M.W.
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.1
    • /
    • pp.41-48
    • /
    • 2004
  • A safety assessment code, called SAGE (Safety Assessment Groundwater Evaluation), has been developed to describe post-closure radionuclide releases and potential radiological doses for low- and intermediate-level radioactive waste (LILW) disposal in an engineered vault facility in Korea. The conceptual model implemented in the code is focused on the release of radionuclide from a gradually degrading engineered barrier system to an underlying unsaturated zone, thence to a saturated groundwater zone. The radionuclide transport equations are solved by spatially discretizing the disposal system into a series of compartments. Mass transfer between compartments is by diffusion/dispersion and advection. In all compartments, radionuclides ate decayed either as a single-member chain or as multi-member chains. The biosphere is represented as a set of steady-state, radionuclide-specific pathway dose conversion factors that are multiplied by the appropriate release rate from the far field for each pathway. The code has the capability to treat input parameters either deterministically or probabilistically. Parameter input is achieved through a user-friendly Graphical User Interface. An application is presented, which is compared against safety assessment results from the other computer codes, to benchmark the reliability of system-level conceptual modeling of the code.

Investigation of Microbial Contamination in Oenanthe javanica at Postharvest Environments (미나리(Oenanthe javanica) 수확 후 처리 환경에서의 위생지표세균 및 병원성 미생물 오염도 조사)

  • Kim, Yeon Rok;Lee, Kyoung Ah;Choi, In-Wook;Lee, Young-Ha;Kim, Se-Ri;Kim, Won-Il;Ryu, Song Hee;Lee, Hyo Sub;Ryu, Jae-Gee;Kim, Hwang-Yong
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.4
    • /
    • pp.268-277
    • /
    • 2014
  • This study assessed microbiological hazards at postharvest stage of dropwort farms (A, B, C, D, E, F, G, H, I) located in 4 different areas in Korea. The samples were assessed for sanitary indication bacteria (total aerobic bacteria, coliform, and Escherichia coli) and pathogenic bacteria (Escherichia coli O157:H7, Listeria monocytogenes, Staphylococcus aureus and Bacillus cereus). Total aerobic bacteria and coliform in 9 dropwort farms were detected at the levels of 0~7.00 and 0~4.25 log CFU/g, mL, of $100cm^2$. In particular, microbial contamination in worker's hand showed higher than cultivation environment factors. Escherichia coli was detected in several farms of soil, irrigation water, washing water and worker's hand and also, dropwort in these farms was contaminated with E. coli (positive reaction). In case of pathogenic bacteria, B. cereus was detected at the highest levels in soil. S. aureus was detected qualitatively from only one sample of dropwort washed by water. E. coli O157:H7 and L. monocytogenes were not detected. Although dropwort pass through 2 process (trimming and washing), the microbial contamination was not differ significantly before and after which indicates that current washing system was not effect on reduction of microorganism. From these results, the postharvest environment and workers have been considered as cross-contamination factors. Thus, processing equipments and personal hygiene should be managed to reduce the microbial contamination of dropwort. Accordingly management system such as good agricultural practices (GAP) criteria is needed for the safety of dropwort

FAULT-TOLERANT DESIGN FOR ADVANCED DIVERSE PROTECTION SYSTEM

  • Oh, Yang Gyun;Jeong, Kin Kwon;Lee, Chang Jae;Lee, Yoon Hee;Baek, Seung Min;Lee, Sang Jeong
    • Nuclear Engineering and Technology
    • /
    • v.45 no.6
    • /
    • pp.795-802
    • /
    • 2013
  • For the improvement of APR1400 Diverse Protection System (DPS) design, the Advanced DPS (ADPS) has recently been developed to enhance the fault tolerance capability of the system. Major fault masking features of the ADPS compared with the APR1400 DPS are the changes to the channel configuration and reactor trip actuation equipment. To minimize the fault occurrences within the ADPS, and to mitigate the consequences of common-cause failures (CCF) within the safety I&C systems, several fault avoidance design features have been applied in the ADPS. The fault avoidance design features include the changes to the system software classification, communication methods, equipment platform, MMI equipment, etc. In addition, the fault detection, location, containment, and recovery processes have been incorporated in the ADPS design. Therefore, it is expected that the ADPS can provide an enhanced fault tolerance capability against the possible faults within the system and its input/output equipment, and the CCF of safety systems.