승강장 스크린 도어(PSD)에 대한 고 신뢰성의 감시 및 제어 시스템 개발 (Development of High Reliability Monitoring and Control System for Platform Screen Door)

  • 김진식;손진근
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.158-162
    • /
    • 2010
  • PSD is automatically opened and closed when subway train arrive on the station. This system was designed to control electric automatic system. These doors will provide passenger safety, energy saving and a good environment in subway. The monitoring and control systems of PSD are configured so that they can be operated in automatic mode in connection with ATO through the composite control panel in the station control room. The objective of this paper is to obtain high reliability that is essential for monitoring and control systems of PSD. The power supply is based on protection circuit using DC power bridge from two UPS. Also, stable communication system consists of CAN communication line redundancy and RF cross protection algorithm. Monitoring state display results show the validity of the proposed high reliability monitoring and control systems of PSD.

The Development of a Flood Protection System for Pad Transformers Using Pneumatic Pressure in Areas Prone to Floods

  • Kim, Gi-Hyun;Lee, Jae-Yong;Bae, Suk-Myong
    • 조명전기설비학회논문지
    • /
    • 제24권3호
    • /
    • pp.27-32
    • /
    • 2010
  • The inundation of substation and ground power equipment breaks out every summer season in low-lying downtown areas and low-lying shores by torrential rain, typhoons and tsunamis. It has, in turn, caused replacement, social and economic costs for blackouts. For activity management regarding flood damage we produced a flood protection system which using the Pad transformer as a basic frame and is developed using pneumatic pressure. We tested safety concerns including insulation resistance and current leakage first for water tank flooding and, second, by an empirical test through supplying 22.9[kV]. We estimate that costs associated with flooding and power failure can be diminished by these advances toward creating a more reliable system.

지하철 역사의 안정적 전원공급을 위한 보호시스템 검토 (A study on present status and improvement of protection relay system in subway station for stable power supply)

  • 나종우;조원강;박동선;유연성;문화수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.433-444
    • /
    • 2008
  • Nowadays, subway station has provided not only transportation but living spaces for everyday activities. Therefore, a variety of facilities have been installed for a safety of citizens such as fire-fighting equipment, platform screen doors and giving high level of benefits such as air-conditioning and heating equipment, escalators, lighting apparatus. In order to operate these facilities appropriately, it is needless to say that electric power supply must be reliable. Many protection relays have been installed to protect electric apparatus and power system, nevertheless it..s study has been insufficient in the concrete. From this paper, through analyzing of protection relay system of electric room operated in line 2 of Seoul metro, we can help to improve stable power supply system of subway station.

  • PDF

지중 금속구조물의 전기방식 원격감시시스템 개발 (The development of On-Line Cathodic Protection Monitoring System)

  • 임헌호;정성우;하희천
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 춘계학술대회 논문집
    • /
    • pp.213-218
    • /
    • 2001
  • These days, corrosion condition of a underground objects is measured by the electric potential between the subject and ground. But this method is implemented by means of manual work with analog voltmeter, which is uneconomic and inefficient. So, We developed real-time On-Line cathodic protection monitoring system that is able to detect corrosion potential conditions of metal objects or various steel structures in the ground continuously, display them with the graphic screen, construct a database, and analyze them simultaneously. Since the data of corrosion and corrosion protection of all underground objects is processed automatically, not manually in this system, It is possible to reduce the manipulated error, and perform precise safety management, maintenance and inspection. As as result, this system can not only guarantee long-life operation, reduction of manpower and cost, but prevent large accidents in advance.

  • PDF

신형경수로 1400을 위한 신뢰성 평가 (Reliability Evaluation for the Advanced Pressurized water Reactor 1400)

  • 강영식
    • 한국안전학회지
    • /
    • 제16권3호
    • /
    • pp.125-134
    • /
    • 2001
  • The Advanced Pressurized rater Reactor 1400(APR1400) system is advanced of the successful Korean Nuclear Power Plants(KSNP) design which meets functional needs for safety enhancement reliability improvement, and control in the human-computer monitoring system. Therefore this paper describes the scoring model in order to justify the reliability and safety in APR 1400 under uncertainty. The structure of this paper consists of the human engineering, risk safety, quality function, safety organization management factors of the qualitative factors in chapter 2, and the expectation results of the normalized scoring model in chapter 3. Finally, the proposed reliability model have provided the technical flexibility not only for functional control fields but also for accidents protection systems in APR 1400 under uncertainty.

  • PDF

개인보호구 착용문화 정착을 위한 제도개선 (Improved System for Establishing a Culture to Wear Personal Protective Gear)

  • 정성효;이용수;김창은
    • 한국건설안전학회 논문집
    • /
    • 제2권1호
    • /
    • pp.16-20
    • /
    • 2019
  • 국내 건설 현장에서 발생한 재해 중 약 50%가 개인보호구 미착용 상태에서의 사고가 재해로 이어진 것이다. 현행법령상 사업주는 개인 보호구를 지급하고 근로자는 개인보호구를 착용해야 하지만 일선 현장에서는 개인 보호구 착용 준수가 미흡한 실정이다. 본 연구는 개인 보호구를 근로자 개인이 구매하여 착용, 관리하는 형태로 제도를 개선하고 개인보호구 구매비용을 근로자에게 환급해 주는 방안에 대한 것이다. 본 논문을 통해 개인 보호구 제도가 효용성있게 개선되고, 개인보호구 착용문화를 정착시켜 재해 예방에 기여할 수 있을 것으로 기대된다.

슈퍼 섬유를 활용한 일체형 Shock Energy Absorber Lanyard Protection Tube 제조 및 특성분석 (Characteristic and Development of All-in-one Shock Energy Absorber Lanyard Protection Tube used Super Fibers)

  • 조진원;권상준;김상태;염정현;강지만;지병철
    • 한국염색가공학회지
    • /
    • 제26권2호
    • /
    • pp.106-113
    • /
    • 2014
  • Work-related falls are a major problem in the construction and roofing industries. To avoid serious injury to the worker caused by high decelerations or forces, different systems to absorb the energy of a fall are implemented in personal protective equipment. In this study, shock energy absorber lanyard protection tube was prepared using high tenacity PET fiber, P-aramid fiber, and UHMWPE fiber, respectively. Dynamic load test and static load test, bursting strength test based on the Korea fall protection equipment standard(Korea Occupational Safety & Health Agency standard 2013-13) or conformity European safety test(CE : EN355) were conducted. Especially maximum arrest force by dynamic load test of energy absorber showed below 6,000N.

해양플랜트의 방화대책 및 설계기술 소개 (Introduction of Fire Protection Technology and Its Design Method of Offshore Facilities)

  • 구명준;최재웅;윤호병
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제1권1호
    • /
    • pp.49-57
    • /
    • 2013
  • 해양플랜트의 설계는 위험요인을 정량적 위험성평가를 통해 계량화하여 그 결과를 설계에 반영하는 것이 일반화되어 있다. 대표적인 위험요소인 화재 위험에 대해서도 이는 마찬가지다. 계량화된 화재 위험에 대해 작업자들이 탈출하는 동안 안전설비의 기능을 유지하고 발생된 화재가 더 크게 전이(escalation)되는 것을 방지하는 것이 방화대책의 궁극적인 목적이다. 본 논문에서는 대표적인 방화대책인 능동방화대책과 수동방화대책의 적용사례를 살펴보고 수동방화대책의 설계기법들을 소개한다. 수동방화대책은 효과적인 방화기법이지만 초기 투자비가 많이 소요되고 운용과 유지보수에 애로사항이 크다. 따라서, 최근 들어 발주자들은 수동방화대책을 최적화하도록 해양플랜트 설계자에게 요청하는 추세이다.

An Improvement of Estimation Method of Source Term to the Environment for Interfacing System LOCA for Typical PWR Using MELCOR code

  • Han, Seok-Jung;Kim, Tae-Woon;Ahn, Kwang-Il
    • Journal of Radiation Protection and Research
    • /
    • 제42권2호
    • /
    • pp.106-113
    • /
    • 2017
  • Background: Interfacing-system loss-of-coolant-accident (ISLOCA) has been identified as the most hazardous accident scenario in the typical PWR plants. The present study as an effort to improve the knowledge of the source term to the environment during ISLOCA focuses on an improvement of the estimation method. Materials and Methods: The improvement was performed to take into account an effect of broken pipeline and auxiliary building structures relevant to ISLOCA. An estimation of the source term to the environment was for the OPR-1000 plants by MELOCR code version 1.8.6. Results and Discussion: The key features of the source term showed that the massive amount of fission products departed from the beginning of core degradation to the vessel breach. Conclusion: The release amount of fission products may be affected by the broken pipeline and the auxiliary building structure associated with release pathway.

양식어장보호를 위한 어장탐지 시스템 개발에 관한 연구 (A Study on the Fishery Detection System for Protection of an Aquaculture Farm)

  • 남택근;임정빈;안영섭
    • 해양환경안전학회지
    • /
    • 제10권2호
    • /
    • pp.49-53
    • /
    • 2004
  • 본 논문에서는 양식어장을 보호하기 위한 어장 탐지 시스템의 개발에 대해 논의한다. 어장탐지시스템(FDS)은 어장에 침입하는 도적선박을 실시간으로 식별하고 어장의 위치변동 둥을 파악하는 기능을 갖는다. 본 연구에서는 어장에 접근하는 물체탐지 및 적아식별을 위해 저가이면서 대역의 레이더 응답기능을 갖는 어장작업선용 AIS(F-AIS)를 개발하여 소형어선 등의 식별기능에 이용하고자 한다.