• Title/Summary/Keyword: Safety ground

Search Result 1,816, Processing Time 0.028 seconds

A study on the ground reaction forces and plantar pressure variables in different safety shoes and applying insole during walking (안전화 형태와 Insole 착용 유무에 따른 보행동작시 하지부위에 대한 지면반발력과 압력분포 부하)

  • Kim, Jung-Jin;Choi, Sang-Bock;Cha, Sang-Eun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.2
    • /
    • pp.131-143
    • /
    • 2007
  • The purpose of this study was to compare the ground reaction forces and plantar pressure variables among three different safety shoes (Type 1: ergonomically designed and high quality shoes, 2: curved and cushioned safety hoes, and 3: regular safety shoes) and to find the effect of insole during walking. Ten healthy subjects were recruited for this study. The ground reaction force was measured using a 3 dimensional motion analysis system. Plantar pressures were measured Pedar Mobile foot pressure scan system. The ground reaction force variables were not significantly different among three different shoe types and insole conditions. After insertion insole, plantar pressure distributions were improved. These results suggest that the type 1 safety shoes was superior than other safety shoes in the statistics, and applying insole could be a possible method to prevent fatigue of lower extremity and musculoskeletal disorders. Further studies are needed to find the effect of ergonomically designed safety shoes design and insole on practical value prevention of musculoskeletal disorder, fatigue and satisfaction of workers.

A Study on the Variation of Ground Safety Factor by Earthworks

  • Kim, Jinhwan;Kwon, O-Il;Baek, Yong;Kim, Chang-Yong
    • The Journal of Engineering Geology
    • /
    • v.24 no.3
    • /
    • pp.333-341
    • /
    • 2014
  • The construction of roads, tunnels, and bridges results in changes to the local terrain that may influence the ground safety factor, which represents the stability of geotechnical structures. In this study, we assessed construction sites that had collapsed as a result of terrain change, and then simulated variation in the ground safety factor with respect to terrain change caused by road construction. We assumed steep slopes to simulate changes in terrain in a mountainous area and assumed that earthworks took place for road construction by cutting a platform into the slope and altering the slope angle of the terrain both above and below the road. We calculated values of the ground safety factor through a stability analysis of the slope both above and below the road, and examined the variation in the safety factor of the above- and below-road slopes with respect to changes in road width. We found that if the slope angle was the same above and below the road, then the change in the ground safety factor during/after road construction occurred in the slope below the road, and if the slope angle above the road differed from that below, then the change occurred in both the above- and below-road slopes. Furthermore, the ground safety factor was essentially constant for road widths exceeding 2-6 m, depending on both above- and below-road slope angle. The findings of this study can be used to guide the management of construction sites and to assess changes in ground stability during road construction work, particularly in the early stages of earthworks, when the road width is narrow.

Analysis of the International Safety Criteria of IEEE Std 80 and IEC 479-1 (배전용 접지전극 안전성 분석을 위한 국제기준 검토)

  • Kang, Moon-Ho;Park, Jae-Duck;Lee, Heung-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.214-217
    • /
    • 2005
  • To improve the safety of facilities and human beings when the ground fault occurs, public power utility prescribes the reasonable ground resistances, measures and controls the ground resistance of all the ground electrodes biennially. Concerning the safety of human, there are two safety criteria widely accepted, i.e. the IEEE Std 80-2000 and the IEC 479-1:1994. The IEEE Std 80-2000 is based on a simplified electric shock model usually translated into permissible touch and step voltages. The IEC 479-1:1994 is less specific than IEEE Std 80-2000 for analysis purpose. The IEC 479-1:1994 provides values of permissible body current against electric shock duration. This paper provides a technical study of these two standards to analyze the safety of human beings of ground electrodes developed recently for distribution power system.

  • PDF

Effects of Position of Auxiliary Probe on Ground Resistance Measurement Using Fall-of-Potential Method

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon
    • International Journal of Safety
    • /
    • v.7 no.2
    • /
    • pp.1-6
    • /
    • 2008
  • In this paper, the effects of the position and the angle of the potential probes on the measurements of the ground resistance using the fall-of-potential method are described and the testing techniques for minimizing the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position and angle of auxiliary probes. In order to analyze the relative error in the measured value of the ground resistance due to the position of the potential probe, the ground resistance was measured for the case in which the distance of the current probe was fixed at 50[m] and the distance of the potential probe was located from 10[m] to 50[m]. Also, the potential probe was located in turn at $30[^{\circ}]$, $45[^{\circ}]$, $60[^{\circ}]$, $90[^{\circ}]$, and $180[^{\circ}]$. As a consequence, relative error decreased with increasing distance of the potential probe and decreasing angle between the current probe and potential probe. The results could help to determine the position of the potential probe during the ground resistance measurement.

Characteristics for Ground Impedance of Counterpoise according to Position of Auxiliary Probe and Frequency (보조전극의 배치 및 주파수에 따른 매설지선의 접지임피던스 특성)

  • Gil, Hyoung-Jun;Kim, Dong-Woo
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.4
    • /
    • pp.33-37
    • /
    • 2012
  • This paper describes the characteristics for ground impedance of counterpoise according to position of auxiliary probe and frequency using the fall-of-potential method and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position of auxiliary probes. In order to analyze the effects of ground impedance due to the distance of the current probe and frequency, ground impedances were measured in case that the distance of current probe was located from 10[m] to 100[m] and the measuring frequency was ranged in 55 [Hz], 128[Hz], 342[Hz], and 513[Hz]. The results could be help to determine the position of auxiliary probe when the ground impedance was measured at grounding system.

Comparison of Ground Resistance Measurement Value by the Substitute Auxiliary Electrode (대체 보조전극을 이용한 접지저항 측정값 비교)

  • Lee, Snag-Ick;Yoo, Jae-Geun;Jeon, Jeong-Chay;Jeon, Hyun-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.85-87
    • /
    • 2007
  • This paper summarize about the auxiliary electrode measured a ground resistance The method to measure a ground resistance is the fall-of-potential method to using an auxiliary electrode. And an auxiliary electrode must be set up on the ground. Today it is so difficult to set up the auxiliary electrode on the ground because of many concrete building and many paved roads. So this paper is regarding of the ground resistance measurement by the substitute auxiliary electrode. It substituted a iron structure around the building, a wire net for auxiliary electrode. This information is confirmed by compared with the measurement value.

  • PDF

Structural Safety Evaluation of PBD Composite Perforator's Leader for Soft Ground Improvement (연약지반 개량 PBD 복합천공기 리더의 구조 안전성 평가)

  • Kim, Min-Ho
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.20 no.6
    • /
    • pp.894-900
    • /
    • 2018
  • Among the soft ground improvement methods, PBD is the most common construction method because it is cheap and construction is fast. However, if the ground is rigid, additional work is required. In this study, the structural safety, natural vibration, and safety angle of the steel vertical tower structure were evaluated in the development of the PBD composite perforator which can be combined with drilling work and PBD construction. Structural safety was assessed when the wind load of 20 m/s was simultaneously applied to the PBD construction load of 20 tons, the perforating operation of 25 tons, and the wind speed of 50 m/s was applied only to the wind load. The natural frequencies were evaluated up to the sixth mode, and the safety angle was evaluated for static and dynamic safety angles.

The Risk Evaluation of Ground Subsidence based on GIS Analysis Method (GIS 분석기법을 활용한 지반침하 위험도 평가)

  • Choi, Byoung Il;Kim, Jong Hoon;Park, Won Joo;Choi, Chang Ho;Kim, Jin Young
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.6
    • /
    • pp.104-109
    • /
    • 2017
  • As the ground subsidence occurred at the center of Seoul area in 2014, the ground subsidence phenomenon was emerged as a social issue in Korea. Even so far, national and local governments and related experts have been making a lot of efforts to prevent ground subsidence phenomenon, but it is still happening all over the country. In this study, we chose 9 influence factors on which ground subsidence and derived weights using AHP(Analytic Hierarchy Process) method for ground subsidence risk analysis. And we analyze the risk of subsidence in ${\bigcirc}{\bigcirc}$city using GIS(Geographic Information System) analysis method and evaluate the potential risk.

A Study on Transient Grounding Performance of Ground Rods

  • Yun Dong-Hyeon;Lee Hyeong-Su;Lee Gwan Hyeong
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2002.11a
    • /
    • pp.281-285
    • /
    • 2002
  • Although DC ground resistance is a good index of performance for a grounding system, it does not reflect the grounding performance during the transient states. Besides, impulse ground impedance, which is defined by a ratio of the peak value of transient ground potential rise to the peak value of impulse current, cannot be an absolute performance index due to its dependence on impulse current shape. In this paper, a grounding performance of needle-typed ground rod has been compared with simple ground rod using HIFREQ[1], which is an engineering electro-magnetic code based on MoM (Method of Moment).

  • PDF

Ground Response Analysis of the Cmpressor Station for Installation of Seismic Instrument (정압관리소의 지전계측기 설치를 위한 지반특성 분석)

  • Kwon, Ki-Jun;Kim, Yong-Gil
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.1
    • /
    • pp.79-86
    • /
    • 2002
  • In the case of earthquake, it is necessary to install earthquake instruments and to measure the ground motions for stable gas supply and restoration in case of supply suspension. Because each point in the site of the gas facilities has different characteristics of ground motion, it is recommended to measure at the point where the ground motion is representative. In this paper, ground motion analysis and noise pattern analysis are carried out to select suitable point for the installation of earthquake instruments and to set of dynamic range of sensors.