• Title/Summary/Keyword: Safety gloves

Search Result 105, Processing Time 0.023 seconds

Distribution of foodborne pathogens in red pepper and environment (고추와 재배환경의 식품매개 병원균 분포)

  • Jung, Jieun;Seo, Seung-Mi;Yang, SuIn;Jin, Hyeon-Suk;Jung, Kyu-Seok;Roh, Eunjung;Jeong, Myeong-In;Ryu, Jae-Gee;Ryu, Kyoung-Yul;Oh, Kwang Kyo
    • Korean Journal of Food Science and Technology
    • /
    • v.53 no.6
    • /
    • pp.799-808
    • /
    • 2021
  • This study was performed to investigate the extent of microbial contamination, the presence of enterotoxin genes, and the antibiotic susceptibility of Bacillus cereus in 58 red pepper plants and 43 environmental samples (soil, irrigation water, and gloves) associated with the plant cultivation. The detected counts of total aerobic bacteria, coliform bacteria, Escherichia coli, Bacillus cereus, and Staphylococcus aureus were lower in these samples, as compared to the regulations of standards for foods; moreover, pathogens, such as E. coli, E. coli O157:H7, Listeria monocytogenes, and Salmonella spp., were not detected. Genes encoding hemolysin BL enterotoxins (hblA, hblC, and hblD) as well as non-hemolytic enterotoxins (nheA, nheB, and nheC) were detected in 23 B. cereus specimens that were isolated from the test samples and had β-hemolytic activity. Interestingly, B. cereus is resistant to β-lactam and susceptible to non-β-lactam antibiotics. However, in this case, the isolated B. cereus specimens exhibited a shift from resistant to intermediate in response to cefotaxime and from susceptible to intermediate in case of rifampin, trimethoprim-sulfamethoxazole, vancomycin, clindamycin, and erythromycin. Therefore, the levels of B. cereus should be monitored to detect changes in antibiotic susceptibility and guarantee their safety.

Water-blocking Asphyxia of N95 Medical Respirator During Hot Environment Work Tasks With Whole-body Enclosed Anti-bioaerosol Suit

  • Jintuo Zhu;Qijun Jiang;Yuxuan Ye;Xinjian He;Jiang Shao;Xinyu Li;Xijie Zhao; Huan Xu;Qi Hu
    • Safety and Health at Work
    • /
    • v.14 no.4
    • /
    • pp.457-466
    • /
    • 2023
  • Background: During hot environment work tasks with whole-body enclosed anti-bioaerosol suit, the combined effect of heavy sweating and exhaled hot humid air may cause the N95 medical respirator to saturate with water/sweat (i.e., water-blocking). Methods: 32 young male subjects with different body mass indexes (BMI) in whole-body protection (N95 medical respirator + one-piece protective suit + head covering + protective face screen + gloves + shoe covers) were asked to simulate waste collecting from each isolated room in a seven-story building at 27-28℃, and the weight, inhalation resistance (Rf), and aerosol penetration of the respirator before worn and after water-blocking were analyzed. Results: All subjects reported water-blocking asphyxia of the N95 respirators within 36-67 min of the task. When water-blocking occurred, the Rf and 10-200 nm total aerosol penetration (Pt) of the respirators reached up to 1270-1810 Pa and 17.3-23.3%, respectively, which were 10 and 8 times of that before wearing. The most penetration particle size of the respirators increased from 49-65 nm before worn to 115-154 nm under water-blocking condition, and the corresponding maximum size-dependent aerosol penetration increased from 2.5-3.5% to 20-27%. With the increase of BMI, the water-blocking occurrence time firstly increased then reduced, while the Rf, Pt, and absorbed water all increased significantly. Conclusions: This study reveals respirator water-blocking and its serious negative impacts on respiratory protection. When performing moderate-to-high-load tasks with whole-body protection in a hot environment, it is recommended that respirator be replaced with a new one at least every hour to avoid water-blocking asphyxia.

A study on smart fashion product development trends (스마트패션제품 개발 동향에 관한 연구)

  • Suh, Sung-Eun;Roh, Jung-Sim
    • The Research Journal of the Costume Culture
    • /
    • v.23 no.6
    • /
    • pp.1097-1115
    • /
    • 2015
  • ICT in the IOT era is the core basis of modern society. This study investigated and analyzed the recent commercialization trends of smart fashion products internationally and domestically, to utilize them as the basis of data for developing user-friendly smart fashion products that can meet the needs of consumers. Keyword research using the most representative search engines, Google and Naver was conducted for searching for various wearable items commercialized actively since 2010. The final 78 products were classified by the physical area, and the key features and benefits were analyzed. Smart fashion products were classified as four physical types for the head and face, torso, arms and hands, and ankles and feet. Smart fashion products for each body part were developed in various ways, such as hats, glasses, lenses, virtual screens, earphones, headsets, clothing, watches, wrist bands, gloves, rings, wallets, bags, anklets, shoes, socks, and insoles. The main features were music playback, bluetooth, a camera based on NFC, virtual effects, health and safety protection through measuring heartbeat and momentum, and social network sharing of all kinds of information, based on inter-working with a smartphone. These functions represent the physical, social, and emotional interactions among users and their surroundings, as well as the users, themselves. The research results are expected to be used in future studies on planning user-friendly and marketable products through in-depth analysis of the design characteristics of smart fashion products as well as consumer responses.

The Related Factor on a Work Environment of Hairdressers and a Subjective Symptom of Respiratory Organ (미용사들의 작업환경과 호흡기 자각증상과의 관련요인)

  • Lee, Gye-Suk;Lee, Myoung-Hee
    • Korean Journal of Human Ecology
    • /
    • v.17 no.6
    • /
    • pp.1215-1224
    • /
    • 2008
  • This research has measured the indoor environment of thirty hair salons, which are located on Gunsan-Si, Jeonlabbuk-Do, from April 1st to April 30th 2005, to examine the related factors on a work environment of hairdressers and a revelation of respiratory symptom, and has polled 260 hairdressers and 350 office workers. After measuring the physical environment of hair salons, the room temperature, the relative humidity and the illumination was in an agreeable range, and 60 percent of hair salons depended on the natural ventilation through the windows. The levels of acetone, toluene and xylene, which were measured at the hair salons, were all under the safety standards (p<0.05), but these are still harmful and volatile matters, so they can be bad for your health by the contact of skin and respiration. The harmful factors that affect a revelation of respiratory symptom were the group who has many exposures of permanent wave or bleaching/dyeing and not many experiences of hairdressing work, the group who smokes every day, and the group who never exercises at all (p<0.05). This result shows that there are possibilities of health problem for hairdressers from the constant and repeating hairdressing works with the exposure of chemicals such as the permanent, bleaching and dyeing. so that hairdressers recognize that they need appropriate ventilation facilities for their agreeable indoor-environments. And also, to prevent the direct exposure of chemicals as much as they can, they need to have an active management of an individual health care by wearing gloves, mask or something like that.

Study on the perception of health science college students about the personal protection of dental personnels (치과 의료종사자의 개인보호장구 착용에 대한 보건계열 대학생의 인식)

  • Kang, Eun-Ju;Choi, Mi-Hye
    • Journal of Korean society of Dental Hygiene
    • /
    • v.11 no.5
    • /
    • pp.637-647
    • /
    • 2011
  • Objectives : This study was performed to enhance infection control and to establish the fundamental and practical improvement by the survey on personal protection of dental personnels with health science college students. Methods : We performed the survey with 585 individual students affiliated with health science in Jeonbuk province and statistically analyzed by SPSS 12.0 program. Results : The frequencies of the clinic gown as a personal protection were 96.0% of dentists (p<0.01) and 88.0% of dental hygienists (p<0.05) respectively in college-associated dental hospital when we compared with institution scale. The frequencies of the medical gloves as a compulsory personal protection were 47.2% of dentists and 34.6% of dental hygienists respectively (p<0.001). The frequencies of the medical mask as a compulsory personal protection were 84.0% of dentists (p<0.001) and 52.2% of dental hygienists (p<0.05) respectively shown by freshman students. The frequencies of the safety glasses as a compulsory personal protection were 12.3% of dentists and 2.5% of dental hygienists shown by freshman students (p<0.001). Conclusions : The results reflect that current dental personnel's concern of personal protection need to be increased continuously in accordance with current demands and eventually suggest their effort to put their action on personal protection in their dental office.

A Study on the Registration of Patent and Utility Models by Fashion Firms in Korea -Focus on IPC A41B and A41D- (패션기업의 특허.실용신안 등록현황에 관한 연구 -IPC분류코드 A41B와 A41D를 중심으로-)

  • Kim, Yong-Ju
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.35 no.2
    • /
    • pp.192-205
    • /
    • 2011
  • This study analyzed the registration of patent and utility models by fashion firms in Korea. A total of 2,291 registration cases of IPC A41B-H from the period of 1996 to 2009 were collected by KIPRIS of the Korean Intellectual Property Organization (KIPO). All cases were analyzed by year to review the longitudinal trend and 481 cases of IPC A41B (shirts, underwear, baby linen, and handkerchiefs) and 1088 cases of IPC A41D (outerwear, protective garments, and accessories) were analyzed by content (provided benefit type and developing method), by detailed product items and the characteristics of the applicant. The results of this study were as follows: 1) Registration of IPC 41 increased steeply by the year (especially since 2006) and the patent registrations increased more than those in the utility model. 2) Analyzing the application content of A41B on the basis of benefit showed that 75% were to provide new functions and the rest were for health. In terms of the developing method, 83% of benefit provided by the application were by design development, 11.2% were by material, and the rest was by process, In the cases of IPC A41D, 23.6% were for safety and protection. In terms of the developing method, the process and material development were more frequently adopted than in the cases of A41B. 3) The major product types of A41B were socks, underwear, and infant wear, whereas gloves and parts of clothing were major items in A41D. 4) In terms of the characteristics of the applicant, registration by firms was greater for patents than for utility models and registration by foreigners increased in 2006 due to the complete opening of the retail market. 5) Fifteen universities registered for a total 57 cases and major applications were for IT related clothing or high-tech protective items.

Thermal Packaging for Firefighters' Personal Protective Elctronic Equipments (소방대원 개인보호용 전자장비 패키징 기술개발)

  • Park, Woo-Tae;Jeon, Jiwon;Choi, Han Tak;Woo, Hee Kwon;Woo, Deokha;Lee, Sangyoup
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.319-325
    • /
    • 2015
  • While the conventional personal protective equipments (PPEs) covers a variety of devices and garments such as respirators, turnout gear, gloves, blankets and gas masks, several electronic devices such as personal alert safety system (PASS) and heads-up displays in the facepiece have become a part of firefighters personal protective equipments through past several years. Furthermore, more advanced electronic sensors including location traking sensor, thermal imaging caerma, toxic gas detectors, and even physiological monitoring sensors are being integrated into ensemble elements for better protection of firefighters from fire sites. Despite any electronic equipment placed on the firefighter must withstand environmental extremes and continue to properly function under any thermal conditions that firefighters routinely face, there are no specific criteria for these electronics to define functionability of these devices under given thermal conditions. Although manufacturers provide the specifications and performance guidelines for their products, their operation guidelines hardly match the real thermal conditions. Present study overviews firefighter's fatalities and thermal conditions that firefighters and their equipments face. Lastly, thermal packaging methods that we have developed and tested are introduced.

A Technical Trend on Natural Rubber Electrical Conduction Mechanism (천연고무의 전기전도기구에 관한 기술 동향)

  • Baek, Jae-Wook;Son, Sang-Cheol;Kim, Young-Keun;Oh, Jae-Han;Kim, Hyung-Gon;Choi, Yong-Sung;Moon, Jong-Dae;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1970-1971
    • /
    • 2007
  • The efficiency of such work highly depend on the worker's safety, who is protected by tools such as gloves, sleeves, blankets and flexible coverings among other manufactured natural-rubber goods. Use, storage and maintenance of these tools guarantee the quality and durability of the material. However, it might be observed that good tools made of such material are disapproved of when received from manufacturers or when they are removed from the warehouse for replacement. This work shows the experimental results obtained from ageing at a temperature of $100^{\circ}C$ for 48, 70 and 312 h, although the application of AC electrical tension in samples and the measuring of current leakage are presented. The measurements in samples were carried out with samples prepared from the deformulated commercial materials and respectively reformulated into thin films. The obtained results showed the mechanisms of conduction of samples in low and high electric fields. It was also identified an electric tension transition showing that in low fields it prevails the Ohm's law conduction, and in high electric fields it prevails the conduction of space charge limited current (SCLC). These results can support the natural rubber formulation process having as their main objective the reducing of the mechanisms that occur under high conduction current in high electric fields, which leads the material to a dielectric breakdown. It is necessary to research this raw material from different internationally standard clones to characterize dielectric and electric properties for industrial applications. Moreover, this natural material has a low commercial price when compared to the synthetic ones.

  • PDF

Radiation Dose Distribution of a Surgeon and Medical Staff during Orthopedic Balloon Kyphoplasty in Japan

  • Ono, Koji;Kumasawa, Takafumi;Shimatani, Keiichi;Kanou, Masatoshi;Yamaguchi, Ichiro;Kunugita, Naoki
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.2
    • /
    • pp.86-92
    • /
    • 2022
  • Background: The present study investigated the radiation dose distribution of balloon kyphoplasty (BKP) among surgeons and medical staff, and this is the first research to observe such exposure in Japan. Materials and Methods: The study subjects were an orthopedic surgeon (n = 1) and surgical staff (n = 9) who intervened in BKP surgery performed at the National Hospital Organization Disaster Medical Center (Tokyo, Japan) between March 2019 and October 2019. Only disposable protective gloves (0.022 mmPb equivalent thickness or less) and trunk protectors were used, and no protective glasses or thyroid drapes were used. Results and Discussion: The surgery time per vertebral body was 36.2 minutes, and the fluoroscopic time was 6.8 minutes. The average exposure dose per vertebral body was 1.46 mSv for the finger (70 ㎛ dose equivalent), 0.24 mSv for the lens of the eye (3 mm dose equivalent), 0.11 mSv for the neck (10 mm dose equivalent), and 0.03 mSv for the chest (10 mm dose equivalent) under the protective suit.The estimated cumulative radiation exposure dose of 23 cases of BKP was calculated to be 50.37 mSv for the fingers, 8.27 mSv for the lens, 3.91 mSv for the neck, and 1.15 mSv for the chest. Conclusion: It is important to know the exposure dose of orthopedic surgeons, implement measures for exposure reduction, and verify the safety of daily use of radiation during surgery and examination.

A New Radiation-Shielding Device for Restraining Veterinary Patients

  • Songyi Kim;Minju Lee;Miju Oh;Yooyoung Lee;Jiyoung Ban;Jiwoon Park;Sojin Kim;Uhjin Kim;Jaepung Han;Dongwoo Chang
    • Journal of Veterinary Clinics
    • /
    • v.40 no.6
    • /
    • pp.429-437
    • /
    • 2023
  • In veterinary medicine, most radiographic images are obtained by restraining patients, inevitably exposing the restrainer to secondary scattered radiation. Radiation exposure can result in stochastic reactions such as cancer and genetic effects, as well as deterministic reactions such as skin burns, cataracts, and bone marrow suppression. Radiation-shielding equipment, including aprons, thyroid shields, eyewear, and gloves, can reduce radiation exposure. However, the risk of radiation exposure to the upper arms, face, and back remains, and lead aprons and thyroid shields are heavy, restricting movement. We designed a new radiation-shielding system and compared its shielding ability with those of conventional radiation-shielding systems. We hypothesized that the new shielding system would have a wider radiation-shielding range and similar shielding ability. The radiation exposure dose differed significantly between the conventional and new shielding systems in the forehead, chin, and bilateral upper arm areas (p < 0.001). When both systems were used together, the radiation-shielding ability was better than when only one system was used at all anatomical locations (p < 0.01). This study suggests that the new radiation-shielding system is essential and convenient for veterinary radiation workers because it is a step closer to radiation safety in veterinary radiography.