• Title/Summary/Keyword: Safety evaluation model

Search Result 1,239, Processing Time 0.029 seconds

Optimal Sensor Placement for Improved Prediction Accuracy of Structural Responses in Model Test of Multi-Linked Floating Offshore Systems Using Genetic Algorithms (다중연결 해양부유체의 모형시험 구조응답 예측정확도 향상을 위한 유전알고리즘을 이용한 센서배치 최적화)

  • Kichan Sim;Kangsu Lee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.37 no.3
    • /
    • pp.163-171
    • /
    • 2024
  • Structural health monitoring for ships and offshore structures is important in various aspects. Ships and offshore structures are continuously exposed to various environmental conditions, such as waves, wind, and currents. In the event of an accident, immense economic losses, environmental pollution, and safety problems can occur, so it is necessary to detect structural damage or defects early. In this study, structural response data of multi-linked floating offshore structures under various wave load conditions was calculated by performing fluid-structure coupled analysis. Furthermore, the order reduction method with distortion base mode was applied to the structures for predicting the structural response by using the results of numerical analysis. The distortion base mode order reduction method can predict the structural response of a desired area with high accuracy, but prediction performance is affected by sensor arrangement. Optimization based on a genetic algorithm was performed to search for optimal sensor arrangement and improve the prediction performance of the distortion base mode-based reduced-order model. Consequently, a sensor arrangement that predicted the structural response with an error of about 84.0% less than the initial sensor arrangement was derived based on the root mean squared error, which is a prediction performance evaluation index. The computational cost was reduced by about 8 times compared to evaluating the prediction performance of reduced-order models for a total of 43,758 sensor arrangement combinations. and the expected performance was overturned to approximately 84.0% based on sensor placement, including the largest square root error.

A Structural Analysis of the SNF(Spent Nuclear Fuel) Disposal Canister with the SNF Basket Section Shape Change for the Pressurized Water Reactor(PWR) (고준위폐기물다발의 단면형상 변화에 따른 가압경수로(PWR)용 고준위폐기물 처분용기의 구조해석)

  • Kwon, Young-Joo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.1
    • /
    • pp.37-49
    • /
    • 2012
  • A structural model of the SNF(spent nuclear fuel) disposal canister for the PWR(pressurized water reactor) for about 10,000 years long term deposition at a 500m deep granitic bedrock repository has been developed through various structural safety evaluations. The SNF disposal baskets of this canister model have the array type whose four square cross section baskets stand parallel to each other and symmetrically with respect to the center of the canister section. However, whether this developed structural model of the SNF disposal canister is optimal is not determinable yet. Especially, there is still a problem in weight-reduction of the canister. The cross section shape of the SNF basket should be changed to solve this problem. There are two ways in changing the cross section shape of the SNF basket; the one is to rotate the cross section itself and the other is to change the cross section shape as other shape different from the square cross section. The previous study shows that the canister with $30{\sim}35^{\circ}$ rotated basket array is structurally more stable than the canister with un-rotated parallel basket array. However, whether this canister with rotated basket array is optimal is not either determinable as yet, because it is not revealed that the canister with other cross section different from the square cross section is structurally more stable than other canisters. Therefore, the structural analysis of the SNF disposal canister with other cross section shape which is also symmetric with respect to the canister center planes is very necessary. The structural analysis of the canister with various cross section shape basket array in which each basket is arrayed symmetrically with respect to the center planes is carried out in this paper. The structural analysis result shows that the SNF disposal canister with circular cross section shape baskets located symmetrically with respect to the center of the canister section is structurally more stable than the previously developed SNF disposal canister with the parallel basket array.

Relationship between Science Education Researchers' Views on Science Educational Theories for Pre-service Science Teachers and the Examination for Appointing Secondary School Science Teachers (예비과학교사에게 필요한 과학교육학 이론에 대한 과학교육 연구자들의 의견과 중등과학교사임용시험의 연관성)

  • Lee, Bongwoo;Shim, Kew-Cheol;Shin, Myeong-Kyeong;Kim, Jonghee;Choi, Jaehyeok;Park, Eunmi;Yoon, Jihyun;Kwon, Yongju;Kim, Yong-Jin
    • Journal of The Korean Association For Science Education
    • /
    • v.33 no.4
    • /
    • pp.826-839
    • /
    • 2013
  • The purpose of this study is to examine science education researchers' views on what and how much science educational theories would be needed for pre-service science teachers, and to investigate the relationship between their views and the Examination for Appointing Secondary School Science Teachers(EASST). For this study, the views of science education professors on science education theories have been analyzed in terms of their priorities for contributing to the improvement of science teacher competency and literacy. Their views have been compared with proportions of questions related to science education theories of the EASST in terms of what kinds of science education theories have been used for solving each item. As results of this study show, they have perceived that more essential things are needed for the improvement of science teacher competency and literacy including science inquiry process, methods of experimental equipments and tools, laboratory safety, misconception of students, discussion, writing, evaluation of scientific knowledges, and evaluation of scientific inquiry ability other than science philosophy, changes of science curricula, science curricula of foreign countries, Bruner's instructional theory, Karplus's Learning Cycle model, generative learning model, discovery learning model, and Klopfer's taxonomy of educational objectives. There is a higher proportion of questions related to science curriculum and Ausubel's learning theory in the EASST. They are hardly correlated with science education professors' selections of science educational theories for EASST questions. This study advocates the needs of exploring a new method of narrowing down the gap between science educators' opinions and questions of ESSAT in terms of science educaiton theories.

Evaluation of Efficacy and Development of Predictive Model of Sanitizers and Disinfectants on Reduction of Microorganisms on Food Contact Surfaces (스테인리스 스틸 식품기구 표면에 사용되는 주요 살균소독제의 살균력 평가 및 살균예측모델 개발)

  • Lee, Yu-Si;Ha, Sang-Do;Kim, Dong-Ho;Park, Joon-Hee
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.3
    • /
    • pp.203-208
    • /
    • 2011
  • This study was to evaluate the efficacy of sanitizer concentrations and treatment time against two major toad-borne pathogenic microorganisms such as Escherichia coli and Staphylococcus aureus on a stainless steel surface. As a result, stainless steel, treated with 100 ppm of chlorine showed reduction of E. coli(1.56, 1.49, 1.95 log cfu/25 $cm^2$) and S. aureus(0.49, 0.88, 1.27 log cfu/25 $cm^2$) after 0, 5 and 10 min, but none was not detected in treatment with 200 ppm. The population of E. coli(0.73, 0.90, 1.55 log cfu/25 $cm^2$) and S. aureus(0.37, 1.00, 1.45 log cfu/25 $cm^2$) reduced in 35.5% ethanol treated group, but none was not detected in treatment with 70%. The population was reduced E coli(0.28, 0.64, 1.07 cfu/25 $cm^2$) and S. aureus(0.53, 0.87, 0.99 log cfu/25 $cm^2$) by treatment with 45.5 ppm of hydrogen peroxide, but none was not detected in treatment with 91 ppm. Quarternary ammonium compound with 100 ppm was reduced E. coli(0.82, 1.62, 1.71 log cfu/25 $cm^2$) and S. aureus(0.46, 0.93, 1.38 log cfu/25 $cm^2$), but none was not detected in treatment with 200 ppm. Predictive models of sterilization for all 4 disinfectants were suitable to use with $r^2$ value of higher than 0.94. These models may be of use to food services and manufacture of safe products by controlling E. coli and S. aureus without the need for further detection of the organisms.

Developing a Model for Crime Prevention Hardware Performance Test and Certification System (방범하드웨어의 침입범죄 저항성능 시험·인증 체계에 관한 모형 연구)

  • Park, Hyeon-ho
    • Korean Security Journal
    • /
    • no.36
    • /
    • pp.255-292
    • /
    • 2013
  • Burglary (also called breaking and entering and sometimes housebreaking) is a crime, the essence of which is illegal entry into a building for the purposes of committing an offence. It is one of the most common types of crime and also a serious issue for every society. A house that is left insecure is an accessible and attractive target for burglars and therefore burglary resistance test & certification system for doors and windows has been developed in many countries. This paper explores several advanced foreign burglary resistance test/certifcation cases (the British SBD, the Dutch KOMO SKH/SKG, the Japanese CP mark, the Australian Standard Certification) for security products and domestic test/certification systems for fire safety products as a comparative study so that any improvement points can be gained for South Korea in the field of security product performance. The comparative analysis results show that South Korea is far behind the security product certification system and needs a lot of improvement in the system by benchmarking foreign cases. The domestic test/certification systems for fire safety products also give some insights for burglary-related security products' performance certification system in Korea. Overall, the need for relevant rules and regulations, the establishment of standards regarding testing and certification, including certified security +hardware product in building security certification system, performance testing as well as production testing (i.e. quality management system evaluation), the basic competency of testers, incentive system for certified/high quality security products were suggested in order to make an optimal model for the security production performance testing and certification system in Korea.

  • PDF

Ship's Hull Fouling Management and In-Water Cleaning Techniques (선체부착생물관리와 수중제거기술)

  • Hyun, Bonggil;Jang, Pung-Guk;Shin, Kyoungsoon;Kang, Jung-Hoon;Jang, Min-Chul
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.6
    • /
    • pp.785-795
    • /
    • 2018
  • The International Maritime Organization (IMO) has recognized the risk of hull fouling and announced '2011 Guidelines for the control and management of ship's biofouling to minimize the transfer of invasive aquatic species'and is planning international regulations to enforce them in the future. In this study, to effectively respond to future international regulation, we introduce the case of leading countries related to management of hull fouling and also investigate environmental risk assessment techniques for in-water cleaning. Australia and New Zealand, the leading countries in hull fouling management, have established hull fouling regulations through biological and chemical risk assessment based on in-water cleaning scenarios. Most European countries without their government regulation have been found to perform in-water cleaning in accordance with the IMO's hull fouling regulations. In the Republic of Korea, there is no domestic law for hull fouling organisms, and only approximately 17 species of marine ecological disturbance organisms, are designated and managed under the Marine Ecosystem Law. Since in-water cleaning is accompanied by diffusion of alien species and release of chemical substances into aquatic environments, results from biological as well as chemical risk assessment are performed separately, and then evaluation of in-water cleaning permission is judged by combining these two results. Biological risk assessment created 40 codes of in-water cleaning scenarios, and calculated Risk Priority Number (RPN) scores based on key factors that affect intrusion of alien species during in-water cleaning. Chemical risk assessment was performed using the MAMPEC (Marine Antifoulant Model to Predict Environmental Concentrations), to determine PEC and PNEC values based on copper concentration released during in-water cleaning. Finally, if the PEC/PNEC ratio is >1, it means that chemical risk is high. Based on the assumption that the R/V EARDO ship performs in-water cleaning at Busan's Gamcheon Port, biological risk was estimated to be low due to the RPN value was <10,000, but the PEC/PNEC ratio was higher than 1, it was evaluated as impossible for in-water cleaning. Therefore, it will be necessary for the Republic of Korea to develop the in-water cleaning technology by referring to the case of leading countries and to establish domestic law of ship's hull fouling management, suitable for domestic harbors.

An Analytical Study on the Seismic Behavior and Safety of Vertical Hydrogen Storage Vessels Under the Earthquakes (지진 시 수직형 수소 저장용기의 거동 특성 분석 및 안전성에 관한 해석적 연구)

  • Sang-Moon Lee;Young-Jun Bae;Woo-Young Jung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.152-161
    • /
    • 2023
  • In general, large-capacity hydrogen storage vessels, typically in the form of vertical cylindrical vessels, are constructed using steel materials. These vessels are anchored to foundation slabs that are specially designed to suit the environmental conditions. This anchoring method involves pre-installed anchors on top of the concrete foundation slab. However, it's important to note that such a design can result in concentrated stresses at the anchoring points when external forces, such as seismic events, are at play. This may lead to potential structural damage due to anchor and concrete damage. For this reason, in this study, it selected an vertical hydrogen storage vessel based on site observations and created a 3D finite element model. Artificial seismic motions made following the procedures specified in ICC-ES AC 156, as well as domestic recorded earthquakes with a magnitude greater than 5.0, were applied to analyze the structural behavior and performance of the target structures. Conducting experiments on a structure built to actual scale would be ideal, but due to practical constraints, it proved challenging to execute. Therefore, it opted for an analytical approach to assess the safety of the target structure. Regarding the structural response characteristics, the acceleration induced by seismic motion was observed to amplify by approximately ten times compared to the input seismic motions. Additionally, there was a tendency for a decrease in amplification as the response acceleration was transmitted to the point where the centre of gravity is located. For the vulnerable components, specifically the sub-system (support columns and anchorages), the stress levels were found to satisfy the allowable stress criteria. However, the concrete's tensile strength exhibited only about a 5% margin of safety compared to the allowable stress. This indicates the need for mitigation strategies in addressing these concerns. Based on the research findings presented in this paper, it is anticipated that predictable load information for the design of storage vessels required for future shaking table tests will be provided.

Clinical Efficacy of Erdosteine in Patients with Acute or Chronic Bronchitis -A Randomized, Double Blind, Comparative Study vs. Ambroxol- (급.만성 기관지염 환자에서 엘도스$^{(R)}$(Erdosteine)의 임상효과 -염산 암브록솔과의 무작위 이중맹검 비교시험-)

  • Kim, Seok-Chan;Lee, Sang-Hoak;Song, So-Hyang;Kim, Young-Kyoon;Moon, Hwa-Sik;Song, Jeong-Sup;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.6
    • /
    • pp.1296-1307
    • /
    • 1997
  • Background : Erdosteine is a thiol derivative developed for the treatement of chronic obstructive bronchitis, including acute infective exacerbation of chronic bronchitis. Erdosteine has mucomodulating and antioxidant properties and especially exhibits excellent gastrointestinal tolerability. Methods : The study was conducted as a prospective evaluation, with 2 comparative groups orally treated with erdosteine 300mg (bid.) or ambroxol 30mg (b.i.d.) for 7 days and the design of trial was double-blind. The treatments have been assigned randomly to patients (n=80) with acute or chronic bronchitis. The primary end-point used to determine efficacy in this study was subjective symptoms including expectorating frequence, expectoration volume, expectorating difficulty, expectoration viscosity, cough intensity and dyspnea. The secondary end-points of efficacy was the result of arterial blood gas analysis and pulmonary function test. Safety was evaluated with adverse drug reactions and laboratory tests monitoring. 61 patients was included in the efficacy analysis, due to the fact that 19 patients drop-out for different reasons. The obtained values have been analyzed with paired Hest., ANOVA test., multivariate $t^2$-test, repeated measures analysis of covariance, two sample t-test, loglinear-logit model analysis, Fisher's exact test. Results : 1) There was no significant difference on demographic data and vital signs between erdosteine and ambroxol treated groups. 2) The comparison between erdosteine and ambroxol treated groups showed no significant difference in improvement of each symptom in spite of the more favorable efficacy obtained with erdosteine. No difference on the contrary was observed for arterial blood gas analysis and pulmonary function test. 3) As safety is concerned, no clinical significant changes in laboratory test and symptom were induced in erdosteine and ambroxol treated group and two patients in ambroxol treated group drop-out for adverse reactions in symptom. 4) In the evaluation of final clinical efficacy, erdosteine improved more effectively patient's overall symptoms {very good effect (11/31), good effect (12/31), moderate effect (6/31), no effect (2/31), aggravation (0/31)} than ambroxol {very good effect (6/30), good effect (14/30), moderate effect (5/30), no effect (4/30), aggravation (2/30)}. And the probability of symptomatic improvement by erdosteine compared to ambroxol was 2.5 times. (p<0.05). Conclusion : This study showed that erdosteine was clinically effective and safe drug for treatment of acute and chronic bronchitis.

  • PDF

An Experimental and Numerical Study on the Survivability of a Long Pipe-Type Buoy Structure in Waves (긴 파이프로 이뤄진 세장형 부이 구조물의 파랑 중 생존성에 관한 모형시험 및 수치해석 연구)

  • Kwon, Yong-Ju;Nam, Bo-Woo;Kim, Nam-Woo;Park, In-Bo;Kim, Sea-Moon
    • Journal of Navigation and Port Research
    • /
    • v.42 no.6
    • /
    • pp.427-436
    • /
    • 2018
  • In this study, experimental and numerical analysis were performed on the survivability of a long pipe-type buoy structure in waves. The buoy structure is an articulated tower consisting of an upper structure, buoyancy module, and gravity anchor with long pipes forming the base frame. A series of experiment were performed in the ocean engineering basin of KRISO with the scaled model of 1/ 22 to evaluate the survivability of the buoy structure at West Sea in South Korea. Survival condition was considered as the wave of 50 year return period. Additional experiments were performed to investigate the effects of current and wave period. The factors considered for the evaluation of the buoy's survival were the pitch angle of the structure, anchor reaction force, and the number of submergence of the upper structure. Numerical simulations were carried out with the OrcaFlex, the commercial program for the mooring analysis, with the aim of performing mutual validation with the experimental results. Based on the evaluation, the behavior characteristics of the buoy structure were first examined according to the tidal conditions. The changes were investigated for the pitch angle and anchor reaction force at HAT and LAT conditions, and the results directly compared with those obtained from numerical simulation. Secondly, the response characteristics of the buoy structure were studied depending on the wave period and the presence of current velocity. Third, the number of submergence through video analysis was compared with the simulation results in relation to the submergence of the upper structure. Finally, the simulation results for structural responses which were not directly measured in the experiment were presented, and the structural safety discussed in the survival waves. Through a series of survivability evaluation studies, the behavior characteristics of the buoy structure were examined in survival waves. The vulnerability and utility of the buoy structure were investigated through the sensitivity studies of waves, current, and tides.

Temperature Prediction of Cylinder Components in Medium-Speed Diesel Engine Using Conjugate Heat Transfer Analysis (복합 열전달 해석을 이용한 중속 디젤엔진 실린더 부품 온도 분포 예측)

  • Choi, Seong Wook;Yoon, Wook Hyoen;Park, Jong Il;Kang, Jeong Min;Park, Hyun Joong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.8
    • /
    • pp.781-788
    • /
    • 2013
  • Predicting the engine component temperature is a basic step to conduct structural safety evaluation in medium-speed diesel engine design. Recent trends such as increasing power density and performance necessitate more effective thermal management of the engine for achieving the desired durability and reliability. In addition, the local temperatures of several engine components must be maintained in the proper range to avoid problems such as low- or high-temperature corrosion. Therefore, it is very important to predict the temperature distribution of each engine part accurately in the design stage. In this study, the temperature of an engine component is calculated by using steady-state conjugate heat transfer analysis. A proper approach to determine the thermal load distribution on the thermal boundary area is suggested by using 1D engine system analysis, 3D transient CFD results, and previous experimental data from another developed engine model. A Hyundai HiMSEN engine having 250-mm bore size was chosen to validate the analysis procedure. The predicted results showed a reasonable agreement with experimental results.