• Title/Summary/Keyword: Safety device

Search Result 1,824, Processing Time 0.028 seconds

Research on Development of Dynamo based Vehicle Brake force Inspection Equipment (다이나모 기반의 차량 제동력 검사장비 개발 연구)

  • Lim, Jinwoo;Lee, Kwang-Hee;Kim, John;Lee, Chul-Hee
    • Journal of Auto-vehicle Safety Association
    • /
    • v.9 no.4
    • /
    • pp.20-25
    • /
    • 2017
  • Dynamo based vehicle inspection device is end of line device for automobile industry. The device is utilized as implementing vehicle functionality inspection such as brake force, cruise control, kick-down acceleration, CAN inspection. As dynamo based inspection device is broadly adopted in automobile industry, the dynamic study is required to verify the vehicle test equipment reliability. This research recommends appropriate dynamic brake force inspection procedure and theoretical background for developed equipment. Dynamic characteristic of brake force implementation to roller is simplified. With simplified characteristics, the indirect brake force measurement strategy is developed and adopted. Comparison of each brake force result, the appropriate brake force inspection criterion is given.

Realization of Virtual Device Network(VDN) for Predictive Maintenance

  • Choi, Gi-Heung;Song, Ki-Won
    • Bulletin of the Korean Institute for Industrial Safety
    • /
    • v.2 no.1
    • /
    • pp.6-10
    • /
    • 2002
  • Requirements for Distributed Monitoring and Control Networks(DMCN) differ greatly from those of typical data networks. Specifically, my DMCN technology which employs a filedbus protocol is different from IP network protocol TCP/IP. In general, one needs to integrate fieldbus protocol and TCP/IP to realize DMCN over IP network or internet, which can be viewed as Virtual Device Network(VDN). Interoperability between devices and equipments is essential to enhance the quality and the performance of predictive maintenance(PM). This paper suggests a basic framework for VDN using DMCN over IP network and a method to guarantee interoperability between devices and equipments.

  • PDF

A development of value protection cover as safty device in running water pipe ($\cdot$하수도관의 밸브 개폐통의 안전장치 개발)

  • 허성관;임승환;최종탁
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1998.11a
    • /
    • pp.267-270
    • /
    • 1998
  • Current valve protection cover had problem that the hight of cover cap and road level could not match when the road was repaired and overcovered. But new developed device can solve this problem by forming several grooves in the connecting pipe. This device is devided into col=netting pipe (down side) and cap part.(upper side) On the outside diameter of connecting pipe, several horizontal grooves and two vertical grooves are formed. Through the horizontal grooves, the hight of cap part ran be adjusted with ground level. Therefore, this device can help easy maintenence in running water pipe.

  • PDF

Web-based Predictive Maintenance(PM) (웹 기반 예방 보전에 관한 연구)

  • Gi-Heung Choi
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.213-217
    • /
    • 2001
  • Requirements for Device Networks differ greatly from those of typical data networks. Specifically, any device network technology which employs a fieldbus protocol is different from IP network protocol TCP/IP. In general, one needs to integrate fieldbus protocol and TCP/IP to realize device network over IP network or internet. Interoperability between devices and equipments is essential to enhance the quality and the performance of predictive maintenance(PM). This paper suggests a basic framework for web-based predicted maintenance and a method to guarantee interoperability between devices and equipments.

  • PDF

Development and Application of a Loading/Unloading Device for Effective Material Handling (효율적 인력물자 운반용 적.하화대의 개발 및 활용)

  • 황춘수;장통일;임현교
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.2
    • /
    • pp.125-131
    • /
    • 2003
  • In recent years, the Korean Army made use of fork-lifters or conveyors when loading and/or unloading military material in order to prevent accidents and to promote efficiency of military material handling activities. However, in troops smaller thin battalions, manual material handling activities are still committed for many reasons. In this thesis, a brand new loading/unloading device for efficient military material handling or manual workers was developed, and its validation study was conducted through objective assessment based on electromyography, subjective assessment based on Body-Map technique developed by Corlett and Bishop, and finally work performance comparison. The results of EMG analysis showed that muscular workload improved by 24% when using the device compared to manual work without the device, and complain of each body part was remarkably reduced. In addition, remarkable effectiveness enhancement was observed in the work performance. Consequently, it could be concluded that ergonomic devices like one developed in this research should be studied further in the ergonomic sense as well as in the economical sense.

Development of ESAD with Flight Environment Sensing Function and Sled Test Method for Function Verification (비행환경 감지 기능을 보유한 ESAD 개발 및 기능 확인을 위한 슬레드 시험 방안)

  • Hanseong Jo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.273-280
    • /
    • 2023
  • Recently electronic safety and arming device(ESAD) has attracted increasing attention due to its design flexibility. However, ESAD can be armed unintentionally due to a malfunction of an external device or interface. Thus ESAD needs an internally generated arming signal independent from the external device. In this paper, a new sensor-hybrid ESAD(SHESAD) with a flight environment sensing function for generating arming signal internally is proposed and a sled test based method is also suggested for evaluating its functions. Through the test results, the operability of the flight environment sensing function was confirmed. Also, it is shown that the proposed test method is suitable for verification of ESAD with the flight environment sensing function.

A Study on Development of Guideline on Writing Technical Document for Electrical Medical Devices: Dental X-ray Equipment (치과용엑스선장치의 기술문서 작성을 위한 가이드라인 개발 연구)

  • Lee, Seung-Youl;Kim, Jae-Ryang;Lee, Jun-Ho;Park, Chang-Won
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.651-660
    • /
    • 2016
  • Due to recent population aging, the number of check-up for senior citizens has increased steadily. According to this trend, the market size of dental X-ray equipment and the number of approval and review for these devices have simultaneously increased. The technical document of medical device is required for approval and review for medical device, and medical device companies needs to have work comprehension and expertise, as the document needs to include the overall contents such as performances, test criteria, etc.. Yet, since most of domestic manufacturers or importers of medical devices are small businesses, it is difficult for them to recruit professional manpower for approval of medical devices, and submission of inaccurate technical documents has increased. These problems lead to delay of the approval process and to difficulties in quick entering into the market. Especially, the Ministry of Food and Drug safety (MFDS) standards of a dental extra-oral X-ray equipment, a dental intra-oral X-ray equipment, an arm-type computed tomography, and a portable X-ray system have been recently enacted or not. this guideline of dental X-ray equipment adjusting revised standards was developed to help relative companies and reviewers. For this study, first, the methods to write technical document have been reviewed with revised international and domestic regulations and system. Second, the domestic and foreign market status of each item has been surveyed and analyzed. Third, the contents of technical documents already approved by MFDS have been analyzed to select the correct example, test items, criteria, and methods. Finally, the guideline has been developed based on international and domestic regulation, through close review of a consultative body composed of academic, industrial, research institute and government experts.

Local Installation Device Models for Remote Electrical Safety Monitoring of Electrical Facilities for General Use (일반용 전기설비의 원격 전기안전 감시를 위한 수용가 설치 장치 모델)

  • Jeon, Hyun-Jae;Jeon, Jeong-Chay;Yoo, Jae-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.101-107
    • /
    • 2007
  • In order to introduce remote monitoring system for effective safety management of electrical facilities for general use, which the most of electrical fires and non-inspection problems due to absence are generated development of local device model considering cost and installation is requested. This paper presents local device models for remote electrical safety inspection of electrical facilities for general use and in order to rational model according to installation place of electrical facilities for general use, compare and analysis cost, installation and communication method of local device models. The results show that rational model for remote safety inspection of electrical facilities located in houses, which occupy the must of electrical facilities for general use, is to give safety monitoring ability to low voltage remote meter reading(or automatic meter reading: AMR).

Study on Pedestrian Protection device in collision using Pneumatic cylinder and simple link mechanism (공압 실린더 및 단순 링크기구를 이용한 충돌 보행자 보호 장치에 관한 연구)

  • Noh, S.H.;Lee, D.R.
    • Journal of Power System Engineering
    • /
    • v.12 no.4
    • /
    • pp.64-71
    • /
    • 2008
  • This study is on pedestrian protection device using pneumatic cylinder and simple link mechanism when vehicle collide with pedestrian. This study ensured the safety space between engine and hood after it applies to simple link mechanism and pneumatic cylinder. It can absorb the damage which measure the specific device if vehicle collide with pedestrian. Combination of simple link mechanism and pneumatic cylinder was more superior than the present pedestrian protection device. Simple link mechanism could confirm superior height and survival probability than when only cylinder operated. It also ensured enough space between engine and hood. And if a cylinder is not working because of old cylinder, poor repair or damage of accident vertical cylinder would be difficult to execute because there exists the irregular space between engine and hood. If simple link mechanism operates with only one cylinder it could ensure the regular space because simple link mechanism set up at the middle of hood. So this device could confirm high safety for pedestrian.

  • PDF

A study on Evaluation Methods for Safety and Performance of Electrical Stimulations for Home Use (개인용전기자극기 성능 및 안전성 평가 방법 연구)

  • Kim, San;Jang, Moo-Young;Hwang, Yoon Su;Lee, Ki-Hun;Hur, Chan-Hoi;Hong, Choongman
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.3
    • /
    • pp.187-202
    • /
    • 2013
  • The electronic medical device industry and the relevant market have been greatly expanded owing to various factors, such as the advent of the aged society and the spread of the desire for well-being in developed countries, and rapid development of China, India and other emerging markets. The electrical stimulator is one of electronic medical devices most commonly used in homes. The electrical stimulator is widely used for pain relief, rehabilitation, muscle conditioning and others. Since it is mainly used in homes, it is very important to assure the safety and performance for protection of users. However, there is no guideline on evaluation of safety and performance of such electrical stimulator for home use. In this study, various local and foreign references were reviewed to develop the internationally harmonized procedures for safety and performance evaluation of the electrical stimulator and test items, specifications and methods are proposed. In addition, such proposed test items were validated to decide the internationally harmonized tests for safety and performance evaluation. This study will contribute to improvement of quality and safety of electrical stimulators for home use and help the Korean medical device industry have the international competitiveness.