• 제목/요약/키워드: Safety Measurement

검색결과 2,495건 처리시간 0.026초

철도차량용 차륜 플레이트에서의 새로운 횡압 계측방법 (New Lateral Force Measurement Method of the Wheel Plate for Railway Vehicles)

  • 함영삼;전현규;서정원;이동형;권석진
    • 한국정밀공학회지
    • /
    • 제29권6호
    • /
    • pp.621-625
    • /
    • 2012
  • Conventionally, to measure derailment coefficient of a railway wheel, strain gauges for lateral force measurement are attached to both side of the wheel. But narrow gap between railway wheel and traction motor makes it difficult to attache the strain gauges at the inner side of wheel. In this study, to overcome the hard accessibility to the strain gauge points by narrow gap, a new Wheatstone bridge connection method is presented by attaching all the strain gauges at the outer side of wheel with a new bridge connection. We evaluate the running safety of railway vehicles in accordance with railway safety regulations. The experimental results obtained shows higher sensitivity than conventional methods and the derailment coefficient measurement procedure becomes simpler.

지진가속도 계측기를 이용한 건축물의 긴급 안전성 평가 알고리즘 개발에 대한 연구 (A Study on the Development of a Rapid Safety Assessment System for Buildings Using Seismic Accelerometers)

  • 정성훈;장원석;박병철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권6호
    • /
    • pp.161-170
    • /
    • 2020
  • 본 연구에서는 공공 시설물을 대상으로 설치된 지진가속도 계측 시스템의 운영 효율성 개선을 위하여 지진 이벤트 신호 변환 및 처리 알고리즘을 개발하였다. 더불어 처리된 지진 가속도 시간이력의 분석을 통해 건축물의 안전성을 평가할 수 있는 평가 방법과 평가 기준을 제안하였으며, 테스트베드 건축물에 적용하여 그 작동과 활용성을 검증하였다. 이를 통해 지진 이벤트 계측자료의 분석 정확성을 확보하고, 지진재해 상황에서 재난 대응의 방향과 우선순위 판단을 위한 의사결정 지원자료로 활용할 수 있을 것으로 판단된다.

소듐냉각고속로 KALIMER-600 축소 물모의 열유동 가시화 실험장치 구축 및 거시 유동장 특성 측정 (Water-Simulant Facility Installation for the Sodium-Cooled Fast Reactor KALIMER-600 and Global Flow Measurement)

  • 차재은;김성오
    • 한국가시화정보학회지
    • /
    • 제9권4호
    • /
    • pp.54-62
    • /
    • 2011
  • KAERI has developed a KALIMER-600 which is a pool-type sodium-cooled fast reactor with a 600MWe electric generation capacity. For a SFR development, one of the main topics is an enhancement of the reactor system safety. Therefore, we have a long-term plan to design the large sodium experimental facility to evaluate the reactor safety and component performance. In order to extrapolate a thermal hydraulic phenomena in a large sodium reactor, the thermal hydraulics phenomena is under investigation in a 1/$10^{th}$ water-simulant facility for the KALIMER-600. In this paper, we shortly described the experimental facility setup and the measurement of the isothermal global flow behavior. For the flow field measurement, the PIV method was used in a transparent Plexiglas reactor vessel model at around $20^{\circ}C$ water condition.

e-Business 환경에서 e-Business 인력의 능력 측정을 위한 방법론 (A Methodology to Measure e-HR Capability in an e-Business Environment)

  • 배영주;정순석;유지철
    • 대한안전경영과학회지
    • /
    • 제11권4호
    • /
    • pp.293-300
    • /
    • 2009
  • 기업 인력의 e-Business 적용 능력은 e-Business 환경에서 개인에게 주어진 업무를 효율적으로 수행하고 업무성과를 향상하기 위해 필요하다. 본 연구는 e-Business 인력의 측정도구, 측정체계 및 방법을 제시한다. 개발된 측정도구는 요인분석과 신뢰성 분석을 통하여 그 구조의 타당성을 검증하였고, e-Business 인력을 효과적으로 측정할 수 있는 16 개의 측정항목을 갖는 측정 도구를 제시하였다. 개발된 측정도구의 적용성과 활용성은 실제 e-Business 환경의 기업에서 근무하는e-Business 인력에 적용하여 그 결과를 제시함으로써 확인 하였다. 본 연구는 e-Business 환경의 기업에서 근무하는 인력의 e-Business 능력을 측정하고 개선하는 방법론을 개발하는 데 공헌할 것이다.

RADIATION SAFETY STUDIES AT TOHOKU UNIVERSITY CYRIC

  • Yamadera M. Baba A.;Miura T.;Aoki T.;Hagiwara M.;Kawata N.
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.231-236
    • /
    • 2001
  • A brief introduction is presented on the radiation safety studies at Tohoku University Cyclotron & Radioisotope Center. Studies on two subject are described; (1) measurement of the thick target neutron yield and radioisotope production / activation cross section for ten's of MeV neutrons and ions using K=110 Tohoku University cyclotron to provide basicdata for accelerator shielding, and (2) development of techniques for high sensitive radiation detection and profile measurement using an Imaging Plate which is a high sensitive two-dimensional radiation sensor. Application of the Imaging Plate techniques to localization of very weak radioactivity and to neutron profile measurement is described.

  • PDF

수공구 손잡이의 인간공학적 요소 평가 (Ergonomic Factors Assessment on Hand Tool Handle)

  • 양성환;조문선;강영식
    • 대한안전경영과학회지
    • /
    • 제8권1호
    • /
    • pp.43-52
    • /
    • 2006
  • The goal of this study is to investigate the ergonomic factors in designing or selecting the hand tool handle. Electromyogram (EMG) were measured for various wrist postures and handle sizes under two loading conditions. Anthropometric data were measured and the correlation with EMG measurement data were analyzed. Investigations of this study show that wrist posture should be neutral for minimum muscle tension and optimum handle size can be found by measuring the EMG measurement data. It show that hand width and EMG measurement data is greatly correlated also. This study can be a guide of designing or selecting a hand tool, but further study with large sample sizes and various groups is needed for making general conclusion.

다구찌의 품질특성 측정에 대한 고찰과 사례 연구 (Study on establish for unit of measure for Quality Feature)

  • 박노국;이상복
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2013년 춘계학술대회
    • /
    • pp.163-172
    • /
    • 2013
  • In this Paper, We study on establish for unit of measure. Quality means abstract for customer needs. we surveyed unit of measurement of quality feature of Juran, Taguchi, 6 sigma method. We suggest unit of measurement of quality feature. Each enterprise can use defining own unit of measurement of quality feature. Effect is expected in enterprise that these proposals do quality control. There is meaning in direction that measuring mean of quality feature that propose in this treatise understands actuality to be deeply and reconcile exact point of theory.

  • PDF

품질 특성의 측정에 대한 분석 사례 연구 (Study on establish for unit of measure for Quality Feature)

  • 이희춘;박노국;이상복
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2011년도 추계학술대회
    • /
    • pp.157-165
    • /
    • 2011
  • In this Paper, We study on establish for unit of measure. Quality means abstract for customer needs. we surveyed unit of measurement of quality feature of Juran, Taguchi, 6 sigma method. We suggest unit of measurement of quality feature. Each enterprise can use defining own unit of measurement of quality feature. Effect is expected in enterprise that these proposals do quality control. There is meaning in direction that measuring mean of quality feature that propose in this treatise understands actuality to be deeply and reconcile exact point of theory.

  • PDF

초음파를 이용한 이체 평면접촉부의 정량적인 접촉압력 측정에 관한 연구 (A Study on a Quantitative Measurement of Contact Pressure Between two Rough Flat SurFaces by Means of Ultrasonic Waves.)

  • 김경모;정인성
    • 한국안전학회지
    • /
    • 제5권3호
    • /
    • pp.8-26
    • /
    • 1990
  • It is important to have exact information about the contact pressure distribution in the design of connected parts of machines and structures. In previous works, stress analyses on a two body contact problem have been carried out in large numbers. Besides, the measurement of contact stress is important to confirm the adequateness of the theoretical analysis, to verify appropriateness of Hertzian contact theory and to know the practical pressure distribution, but an excellent measuring method con't be found at present. Therefore, a quantitative measurement of contact pressure by means of ultrasonic waves using a normal probe and an angle has been proposed to measure the contact pressure distribution between two rough flat surfaces. At first, in a new proposed calibration method, the relation between mean contact pressure and sound pressure of reflected waves is obtained by using calibration blocks with various surface roughnesses made of the same material as the rectangular section beams And then, this experimental results are compared with the analytical ones, and the utility of this method is discussed.

  • PDF

정보시스템 신뢰성 향상을 위한 위험점수 측정모델 연구 (A Risk Point Measuring Model for Improvement of the Information System Reliability)

  • 조두호;서장훈
    • 대한안전경영과학회지
    • /
    • 제7권3호
    • /
    • pp.47-61
    • /
    • 2005
  • Many researchers have proved that risk measurement of information systems is a very effective tool for improving confidence of information systems. However, information system risk in Korea still includes many subjective judgements. This study deals with applying a quantitative model to improve risk measurement of information system quality. First of all, we have come up with solutions to improve the evaluation efficiency on risk measurement. We have merged the risk guidelines of COBIT and CMM, and developed a quantified evaluation scheme that call by risk point. We have proved the validity of this model by interviews with experts and by case studies.