• Title/Summary/Keyword: Safety Inspections

Search Result 243, Processing Time 0.025 seconds

Implementation Status of Performance Demonstration Program for Steam Generator Tubing Analysts in Korea

  • Cho, Chan-Hee;Lee, Hee-Jong;Yoo, Hyun-Ju;Nam, Min-Woo;Hong, Sung-Yull
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.1
    • /
    • pp.63-68
    • /
    • 2013
  • Some essential components in nuclear power plants are periodically inspected using non-destructive examinations, for example ultrasonic, eddy current and radiographic examinations, in order to determine their integrity. These components include nuclear power plant items such as vessels, containments, piping systems, pumps, valves, tubes and core support structure. Steam generator tubes have an important safety role because they constitute one of the primary barriers between the radioactive and non-radioactive sides of the nuclear power plant. There is potential that if a tube bursts while a plant is operating, radioactivity from the primary coolant system could escape directly to the atmosphere. Therefore, in-service inspections are critical in maintaining steam generator tube integrity. In general, the eddy current testing is widely used for the inspection of steam generator tubes due to its high inspection speed and flaw detectability on non-magnetic tubes. However, it is not easy to analyze correctly eddy current signals because they are influenced by many factors. Therefore, the performance of eddy current data analysts for steam generator tubing should be demonstrated comprehensively. In Korea, the performance of steam generator tubing analysts has been demonstrated using the Qualified Data Analyst program. This paper describes the performance demonstration program for steam generator tubing analysts and its implementation results in Korea. The pass rate of domestic analysts for this program was 71.4%.

Structural evaluation of an existing steel natatorium by FEM and dynamic measurement

  • Liu, Wei;Gao, Wei-Cheng;Sun, Yi;Yu, Yan-Lei
    • Structural Engineering and Mechanics
    • /
    • v.31 no.5
    • /
    • pp.507-526
    • /
    • 2009
  • Based on numerical and experimental methods, a systematic structural evaluation of a steel natatorium in service was carried out in detail in this paper. Planning of inspection tasks was proposed firstly according to some national codes in China in order to obtain the economic and reliable results. The field visual inspections and static computation were conducted in turn under in-service environmental conditions. Further a three-dimensional finite element model was developed according to its factual geometry properties obtained from the field inspection. An analytical modal analysis was performed to provide the analytical modal properties. The field vibration tests on the natatorium were conducted and then two different system identification methods were used to obtain the dynamic characteristics of the natatorium. A good correlation was achieved in results obtained from the two system identification methods and the finite element method (FEM). The numerical and experimental results demonstrated that the main structure of the natatorium in its present status is safe and it still satisfies the demand of the national codes in China. But the roof system such as purlines and skeletons must be removed and rebuilt completely. Moreover the system identification results showed that field vibration test is sufficient to identify the reliable dynamic properties of the natatorium. The constructive suggestion on structural evaluation of the natatorium is that periodic assessment work must be maintained to ensure the natatorium's safety in the future.

Imporovement Plan of Fire Inspection System (소방검사제도의 개선방안)

  • Lee, Jong-Young;Ki, Tae-Geun
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.181-195
    • /
    • 2009
  • Modern constitution obtains its justice by protecting the people's basic legal rights. The constitutional rights can be more than a defensive measure against government power by modern viewpoints. The government has to create an atmosphere which the rights are not violated. The Constitution provides that the government has to make efforts to prevent disaster and protect the people from danger in Clause 34, Art. 6. The government has an obligation to protect the people's basic legal rights of life, health and property from fire damages, and those rights are gathering strength under a socialist state principle as fundamental ideology of modern societies. The present fire inspection system gains a point constitutionally but it still needs to be certified as the most suitable system. This article examines the solution to operate fire inspection system efficiently, given the reality of present system operation. It is necessary to improve the system by integrating the present fire inspection with the self fire inspection. Government needs to re-modification the Fire inspections system for prevent and promote (resolve) the problem which government officer (ex fire fighter) can make a irregularities and corruption as do it oneself.

Analysis of Fire-Related State Compensation Cases (화재와 관련된 국가배상 사례의 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.109-117
    • /
    • 2019
  • When those who have caused a fire have no ability to compensate fire victims, the victims tend to charge fire agencies for state compensation to receive damage relief. This study analyzed two state compensation cases related to fires. The findings suggest that if there is a causal relationship between fire damage and mistakes committed by fire officials that are associated with fire prevention or special fire inspections, courts usually decide that fire agencies should compensate fire victims. Despite the introduction of a new article in the Framework Act on Fire-Fighting Services on December 26, 2017, titled "Exemption from Responsibility for Fire-Fighting Activities", exemptions are only available if inevitability of the activity has been proven. However, unlike rescue or first aid activity, inevitability is difficult to prove when it comes to fire inspection activity. Therefore, it is expected that state compensation suits related to fires will not decrease.

Cloning and Expression of a Thermostable ${\alpha}$-Galactosidase from the Thermophilic Fungus Talaromyces emersonii in the Methylotrophic Yeast Pichia pastoris

  • Simila, Janika;Gernig, Anita;Murray, Patrick;Fernandes, Sara;Tuohy, Maria G.
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.12
    • /
    • pp.1653-1663
    • /
    • 2010
  • The first gene (${\alpha}$-gal1) encoding an extracellular ${\alpha}$-Dgalactosidase from the thermophilic fungus Talaromyces emersonii was cloned and characterized. The ${\alpha}$-gal1 gene consisted of an open reading frame of 1,792 base pairs interrupted by six introns that encoded a mature protein of 452 amino acids, including a 24 amino acid secretory signal sequence. The translated protein had highest identity with other fungal ${\alpha}$-galactosidases belonging to glycosyl hydrolase family 27. The ${\alpha}$-gal1 gene was overexpressed as a secretory protein with an N-terminal histidine tag in the methylotrophic yeast Pichia pastoris. Recombinant ${\alpha}$-Gal1 was secreted into the culture medium as a monomeric glycoprotein with a maximal yield of 10.75 mg/l and purified to homogeneity using Hisbinding nickel-agarose affinity chromatography. The purified enzyme was maximally active at $70^{\circ}C$, pH 4.5, and lost no activity over 10 days at $50^{\circ}C$. ${\alpha}$-Gal1 followed Michaelis-Menten kinetics ($V_{max}\;of\;240.3{\mu}M/min/mg,\;K_m\;of\;0.294 mM$) and was inhibited competitively by galactose ($K_m{^{obs}}$ of 0.57 mM, $K_i$ of 2.77 mM). The recombinant T. emersonii ${\alpha}$-galactosidase displayed broad substrate preference, being active on both oligo- and polymeric substrates, yet had strict specificity for the ${\alpha}$-galactosidic linkage. Owing to its substrate preference and noteworthy stability, ${\alpha}$-Gal1 is of particular interest for possible biotechnological applications involving the processing of plant materials.

Optimal Inspection Policy for One-Shot Systems Considering Reliability Goal (목표 신뢰도를 고려한 원-샷 시스템의 최적검사정책)

  • Jeong, Seung-Woo;Chung, Young-Bae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.40 no.4
    • /
    • pp.96-104
    • /
    • 2017
  • A one-shot system (device) refers to a system that is stored for a long period of time and is then disposed of after a single mission because it is accompanied by a chemical reaction or physical destruction when it operates, such as shells, munitions in a defense weapon system and automobile airbags. Because these systems are primarily related with safety and life, it is required to maintain a high level of storage reliability. Storage reliability is the probability that the system will operate at a particular point in time after storage. Since the stored one-shot system can be confirmed only through inspection, periodic inspection and maintenance should be performed to maintain a high level of storage reliability. Since the one-shot system is characterized by a large loss in the event of a failure, it is necessary to determine an appropriate inspection period to maintain the storage reliability above the reliability goal. In this study, we propose an optimal inspection policy that minimizes the total cost while exceeding the reliability goal that the storage reliability is set in advance for the one-shot system in which periodic inspections are performed. We assume that the failure time is the Weibull distribution. And the cost model is presented considering the existing storage reliability model by Martinez and Kim et al. The cost components to be included in the cost model are the cost of inspection $c_1$, the cost of loss per unit time between failure and detection $c_2$, the cost of minimum repair of the detected breakdown of units $c_3$, and the overhaul cost $c_4$ of $R_s{\leq}R_g$. And in this paper, we will determine the optimal inspection policy to find the inspection period and number of tests that minimize the expected cost per unit time from the finite lifetime to the overhaul. Compare them through numerical examples.

Development of Image Processing Program to Inspect Concrete Bridges (콘크리트 교량 외관조사용 이미지 처리 프로그램 개발)

  • Lee, Byeong-Ju;Shin, Jae-In;Park, Chang-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.189-192
    • /
    • 2008
  • Generally, the inspection is hard work and needs a lot of time. So, this work contains subjectivity of inspector owing to carry out the visual evaluations through naked eye. Thus, the result of inspection is not objective and reliable. The purpose of this study is to develop new inspection technique to solve above problems and to provide convenient inspection work. We make a new inspection system using digital image processing technology. This program can stitch each image and detect cracks of surface of concrete bridge. Also, It can extract an investigation drawing from the picture. Also, this program is a kind of management tools designed to have some functions such as converting the image data obtained from cameras to Data-Base format, searching and storing the data. At first, we try to make a automatic extracting program. But, changed by semiautomatic method because of various problems. Through field experiments, the application of this inspection system with specialty software has proven to be much faster, safer, and reliable than the inspections carried out by the naked eyes in managing safety of the bridges. The new inspection method may be able to make the inspection of bridge more efficient and reliable.

  • PDF

Anticorrosive Monitoring and Complex Diagnostics of Corrosion-Technical Condition of Main Oil Pipelines in Russia

  • Kosterina, M.;Artemeva, S.;Komarov, M.;Vjunitsky, I.;Pritula, V.
    • Corrosion Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.208-211
    • /
    • 2008
  • Safety operation of main pipelines is primarily provided by anticorrosive monitoring. Anticorrosive monitoring of oil pipeline transportation objects is based on results of complex corrosion inspections, analysis of basic data including design data, definition of a corrosion residual rate and diagnostic of general equipment's technical condition. All the abovementioned arrangements are regulated by normative documents. For diagnostics of corrosion-technical condition of oil pipeline transportation objects one presently uses different methods such as in-line inspection using devices with ultrasonic, magnetic or another detector, acoustic-emission diagnostics, electrometric survey, general external corrosion diagnostics and cameral processing of obtained data. Results of a complex of diagnostics give a possibility: $\cdot$ to arrange a pipeline's sectors according to a degree of corrosion danger; $\cdot$ to check up true condition of pipeline's metal; $\cdot$ to estimate technical condition and working ability of a system of anticorrosive protection. However such a control of corrosion technical condition of a main pipeline creates the appearance of estimation of a true degree of protection of an object if values of protective potential with resistive component are taken into consideration only. So in addition to corrosive technical diagnostics one must define a true residual corrosion rate taking into account protective action of electrochemical protection and true protection of a pipeline one must at times. Realized anticorrosive monitoring enables to take a reasonable decision about further operation of objects according to objects' residual life, variation of operation parameters, repair and dismantlement of objects.

RESEARCH FOR ROBUSTNESS OF THE MIRIS OPTICAL COMPONENTS IN THE SHOCK ENVIRONMENT TEST (MIRIS 충격시험에서의 광학계 안정성 확보를 위한 연구)

  • Moon, B.K.;Kanai, Yoshikazu;Park, S.J.;Park, K.J.;Lee, D.H.;Jeong, W.S.;Park, Y.S.;Pyo, J.H.;Nam, U.W.;Lee, D.H.;Ree, S.W.;Matsumoto, Toshio;Han, W.
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.3
    • /
    • pp.39-47
    • /
    • 2012
  • MIRIS, Multi-purpose Infra-Red Imaging System, is the main payload of STSAT-3 (Korea Science & Technology Satellite 3), which will be launched in the end of 2012 (the exact date to be determined) by a Russian Dnepr rocket. MIRIS consists of two camera systems, SOC (Space Observation Camera) and EOC (Earth Observation Camera). During a shock test for the flight model stability in the launching environment, some lenses of SOC EQM (Engineering Qualification Model) were broken. In order to resolve the lens failure, analyses for cause were performed with visual inspections for lenses and opto-mechanical parts. After modifications of SOC opto-mechanical parts, the shock test was performed again and passed. In this paper, we introduce the solution for lens safety and report the test results.

A Study on the Status of Waterproof Pressure of Indoor Hydrant Proportioner by a survey (옥내소화전의 방수압 실측에 의한 실태조사 연구)

  • Choi, Kyu-Chool;Jeong, Sang
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.255-263
    • /
    • 2009
  • A indoor hydrant proportioner that is installed as fire extinction equipment when a fire breaks out in a building plays a vital role for a fire extinction at an early stage. The indoor waterproof hydrant proportioner installed currently can function in case of fire as fire extinction equipment only when it can maintain proper waterproof pressure meeting the standards stipulated in NFSC. The results of the survey on the waterproof pressure of the indoor hydrant proportioner installed in most buildings showed that the waterproof pressure installed inside the buildings was higher than the agreed level suggested by NFSC, which is very desirable state and is regarded as the results of fire facilities being maintained and managed by regular fire inspections. It is thought that the safety management of fire extinction facilities should be kept up both regularly and steadily through TAB.

  • PDF