• Title/Summary/Keyword: Safety Device

Search Result 1,786, Processing Time 0.03 seconds

A Wearable Safety Device for the Body Protection of Motorcyclists (모터사이클 운전자 신체보호용 안전장치 개발 프로세스)

  • Jang, Dong-Hwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.1
    • /
    • pp.25-33
    • /
    • 2021
  • This paper presents the development process for airbag safety devices fitted in motorcyclists' garments. Motorcycle riders often sustain multiple injuries in crashes since rider post-impact kinematics depend on several variables. This study proposes a newly inflatable safety system connected to the motorcycle by a cable. An airbag device with a mechanical triggering system is deployed when the cable detaches from its mounting clip. Airbag filling tests are performed to determine the mixing ratio of compressed gases with the severance of temperature. To estimate the airbag effectiveness to reduce riders' injuries, numerical analysis is performed using the finite element method. A comparative analysis (i.e., with and without the chosen device) was conducted to evaluate its protective efficacy. Prototype garments based on the proposed design have been created and have undergone sled tests. The proposed safety device could also be beneficial in accidents during other sports activities.

Development of an IoT Device for Detecting Escherichia coli from Various Agri-Foods and Production Environments (IoT 적용 대장균 검출기 개발과 농식품 및 생산환경에 적용)

  • Nguyen, Bao Hung;Chu, Hyeonjin;Kim, Won-Il;Hwang, Injun;Kim, Hyun-Ju;Kim, Hwangyong;Ryu, Kyoungyul;Kim, Se-Ri
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.6
    • /
    • pp.542-550
    • /
    • 2019
  • To detect Escherichia coli from agri-food and production environments, a device based on IoT (internet of things) technology that can check test results in real time on a mobile phone has been developed. The efficiency of the developed device, which combines an incubator equipped with a UV lamp, a high-resolution camera and software to detect E. coli in the field, was evaluated by measuring the device's temperature, detection limit, and detection time. The device showed a difference between its programmed temperature setting and actual temperature of about 1.0℃. In a detection limit test performed with a single-colony inoculation, a color change to yellow and a florescent signal were detected after 12 and 15 h incubations, respectively. The incubation time also decreased along with increasing bacteria levels. When applying the developed method and device to various samples, including utensils, gloves, irrigation water, seeds, and vegetables, detection rates of E. coli using the device were higher than those of the Korean Food Code method. These results show that the developed protocol and device can efficiently detect E. coli from agri-food production environments and vegetables.

Evaluation of dose received by workers while repairing a failed spent resin mixture treatment device

  • Choi, Woo Nyun;Byun, Jaehoon;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.442-448
    • /
    • 2022
  • Intermediate-level radioactive waste (ILW) is not subject to legal approval for cave disposal in Korea. To solve this problem, a spent resin treatment device that separates 14C-containing resin from zeolite/activated carbon and desorbs 14C through a microwave device has been developed. In this study, we evaluated the radiological safety of the operators performing repair work in the event of a failure in such a device treating 1 ton of spent resin mixture per day. Based on the safety evaluation results, it is possible to formulate a design plan that can ensure the safety of workers while developing a commercialized device. When each component of the resin treatment device can be repaired from the outside, the maximum and minimum allowable repair times are calculated as 263.2 h and 27.7 h for the 14C-detached resin storage tank and zeolite/activated carbon storage tank, respectively. For at least 6 h per quarter, the worker's annual dose limit remains within 50 mSv/year; further, over 5 years, it remained within 100 mSv. At least 6 h of repair time per quarter is considered, under conservative conditions, to verify the radiological safety of the worker during repair work within that time.

ISO14971:2019 Detailed Analysis and Periodic Safety Update Report Establishment Method for the Single Use Medical Device - Focusing on Medical Device Regulation 2017/745 requirements (일회용 의료기기에 적용을 위한 ISO 14971:2019 분석과 Periodic Safety Update Report 작성 방법 - Medical Device Regulation 2017/745 요구사항 중심으로)

  • Sang Min, Park;Gyu Ha, Ryu
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.1-10
    • /
    • 2023
  • With the announcement of MEDICAL DEVICE REGULATION 2017/745 (MDR) on April 5 2017, medical device manufacturers shall apply ISO 14971:2019 (3rd) revised in December 2019. However, there is not much related information and guidance available to medical device manufacturers, especially single use medical device. Risk management process basically follow 5 steps which are Risk Analysis, Risk Evaluation, Risk Control, Evaluation of overall residual risk and post-production activities. The purpose of this study is to provide a guidance of from risk analysis with Failure Mode and Effects Analysis (FMEA) table to overall residual risk evaluation for the single use medical device and to reflect it in a Periodic Safety Update Reports (PSUR) to satisfy with MDR requirements with single use medical device which are widely used and manufactured FDA class 2 or CE class IIb as examples. For this study, single use medical device manufacturer can adopt ISO 14971:2019 in accordance with MDR requirements and it can be extended to the PSUR. But there are still limitations to adopt to the all-single use medical device especially high class, private device and implantable device. So, Competent Authority (CA) shall publish more guidance for the single use medical device.

A Study on the Effectiveness of Gas Safety Devices for Domestic (가정용 가스안전기기의 실효성에 관한 연구)

  • Jo Young-Do;Lee Kyung-Sik;Jang Sung-Dong;Kim Ji-Yun
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.4 s.16
    • /
    • pp.62-69
    • /
    • 2001
  • Gas safety devices are very effective to prevent catastrophic gas accident in domestic. The safety devices are included in domestic gas equipment such as extinguishing safety device and adapted at pipeline such as fuse cock, shut off device with gas alarm and so forth. In spite of using those safety devices, a few hundreds of gas accident was happened annually in residential house. In this study, we analysed systematically the domestic accidents which was happened in five years using fault tree analysis(FTA) method and analysed the effectiveness of individual safety device. And also, it was suggested that the rate of accident was decreased quantitatively by increasing safety device which is adapted in domestic. By analysis of 769 gas accidents in domestic, the order of effectiveness of safety device to prevent domestic gas accident was the multi-functional gas-safe-meter(micom-meter), fuse cock, gas leak alarm and CO alarm. If the above four kind of safety device are adapted to every house, about $59\%$ of accident will be reduced and the most of catastrophic gas accident will be Prevented in domestic.

  • PDF

The Characteristics of Electric Shock Accidents and Their Countermeasures for Portable Electrical Tools (이동형 전기기기의 감전재해 특성 및 그 대책)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.21-26
    • /
    • 2017
  • According to the data of Korea Occupational Safety and Health Agency, electric shock accidents during recent 11 years exceeded more than 60% in architecture/other and construction work, the countermeasures for safety are required in the harsh environment of a construction site where moving electric machines and equipments are widely used. The establishment of countermeasure for insulation degradation and defect is required, in consideration of increasing trend for accidents caused by defective insulation among low voltage electrical installation each year. The aim of this study is to propose the policy about portable electrical tool standards and/or worker's safety standards for preventing electric shock accidents on safety workings, and is to develop the technology and the safety device to prevent electric shock for accident prevention reduction through experiments. It obtained the followings through this study; statistical data analysis of late about 10 years of electric shock-related industrial accidents analysis and portable electric tools; safety device development of 'device for testing continuous grounding and power shut-down' to prevent electric shock from portable electric tools. Furthermore, developed results and proposal in this study will help to prevent the electric shock accidents from portable electric tools and will be expected the utilization of policy formulation, educational data and field supplement of the safety device, and etc.

Investigation of an Infrared Temperature Measurement System for Thermal Safety Verification of Plasma Skin Treatment Devices

  • Choi, Jong-ryul;Kim, Wookeun;Kang, Bongkeun;Song, Tae-Ha;Baek, Hee Gyu;Han, Yeong Gil;Park, Jungmoon;Seo, Soowon
    • Current Optics and Photonics
    • /
    • v.1 no.5
    • /
    • pp.500-504
    • /
    • 2017
  • In this paper, we developed a temperature measurement system based on an infrared temperature imaging module for thermal safety verification of a plasma skin treatment device (PSTD). We tested a pilot product of the low-temperature PSTD using the system, and the temperature increase of each plasma torch was well-monitored in real-time. Additionally, through the approximation of the temperature increase of the plasma torches, a certain limitation of the plasma treatment time on skin was established with the International Electrotechnical Commission (IEC) guideline. We determined an appropriate plasma treatment time ($T_{Safe}$ < 24 minutes) using the configured temperature measurement system. We believe that the temperature measurement system has a potential to be employed for testing thermal safety and suitability of various medical devices and industrial instruments.

Development of a Shut-off Device of LP Gas Regulator for Home Use (가정용 LP가스 조정기 차단안전장치의 개발)

  • Kim Young-Gyu;Kim Pil-Jong;Kwon Boo-Kil;Park Gyo-Shik;Kim Ji-Youn
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.3 s.32
    • /
    • pp.54-59
    • /
    • 2006
  • A safety device with shut-off function was developed for preventing intentional accidents that might happen by separating of cutting hoses connected to pressure regulators used in residential LP gas facility. For the verification of function and field adaptability, the safety device with shut-off function was tested in the state of joining the device to the regulator and a field test was carried out at home. This study shows that, at the inlet pressure of 0.07-1.56 MPa, the device shuts off the gas within the 5m length of hose regardless of the installation condition of the regulator. The shut-off flow rate increases in the order of perpendicular upward, horizontal and perpendicular downward. From the results of the field tests carried out at home for 5 months, there appears no problem using a gas range or a boiler. If the developed shut-off device is commercialized and distributed in the market the intentional accidents occurred by cutting or separating hoses can be prevented remarkably.

  • PDF

A Comparative Study on the Electrostatic Eliminator of Piezo Type Ionizer and Pulse AC Corona Type Ionizer (피에조를 이용한 코로나 방전과 펄스교류 코로나 방전을 이용한 정전기 제거장치의 비교 연구)

  • Kwon, Sung-Yul;Lee, Dong-Hoon;Choi, Jae-Wook
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.6
    • /
    • pp.50-54
    • /
    • 2009
  • Ionizer is used for improving manufacturing process and reducing inferior goods in the clean room. As a general rule, neutralization of the electrostatic charge is most important to make TFT-LCD, PDP and OLED. Pulse AC-static eliminator with output voltage of about 10.5kV has been used these days as neutralization device. But this device has a problem with lower performance which was caused by particles-adhesion on the electrode when it has been used for a long time. So we studied to solve the problem with lower performance using high Frequency(72kHz) static eliminator which was produced by Piezo transformer device, and compared Pulse-AC type with Piezo-electronic device such as decay time and ion balance for 10 weeks periods. As a result of this study, we found that Piezo transformer device has been maintained normal condition for 10 weeks. Also, we made the rule by this study, normally Piezo transformer device has to clean the electrode during every 11th weeks.

Study on Reliability Assessment for the Medical Device Software from the Viewpoint of Functional Safety (기능 안전 관점에서의 의료기기 소프트웨어 신뢰성 평가 방법에 관한 연구)

  • Kim, Sung Min;Ko, Byeonggak;Do, Gyeong-Hun;Kim, Hye Jin;Ham, Jung-Keol
    • Journal of Applied Reliability
    • /
    • v.16 no.3
    • /
    • pp.216-223
    • /
    • 2016
  • Purpose: This paper suggests the procedure to enhance the reliability of the software of the medical device that is to cure, treat, diagnose, and prevent a disease or an abnormal health conditions. Methods: After test requirements are classified by the software requirements specification for safety and backgrounds, reliability assessment methods are suggested. Results: Verification and validation for function and safety can be performed whether the medical device software are implemented as intended. Conclusion: Procedure on the static analysis, unit test, integration test, and system test are provided for the medical device software.