• Title/Summary/Keyword: Safety Device

Search Result 1,822, Processing Time 0.029 seconds

Photonic-Crystal-Based Thin Film Sensor for Detecting Volatile Organic Compounds (광결정 기반의 휘발성 유기 화합물 검지 박막 센서)

  • Chang, Hyung-Kwan;Park, Jungyul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.3
    • /
    • pp.149-155
    • /
    • 2016
  • Early detection of toxic gases, such as volatile organic compounds (VOCs), is important for safety and environmental protection. However, the conventional detection methods require long-term measurement times and expensive equipment. In this study, we propose a thin-film-type chemical sensor for VOCs, which consists of self-assembled monosize nanoparticles for 3-D photonic crystal structures and polydimthylsiloxane (PDMS) film. It is operated without any external power source, is truly portable, and has a fast response time. The structure color of the sensor changes when it is exposed to VOCs, because VOCs induce a swelling of the PDMS. Therefore, using this principle of color change, we can create a thin-film sensor for immediate detection of various types of VOCs. The proposed device evidences that a fast response time of just seconds, along with a clear color change, are successfully observed when the sensor is exposed to gas-phase VOCs.

A Study on the Improvement Direction through the Present Status of Nursing Home - Focus on the Nursing Home in Chungcheongbuk-do - (노인요양시설의 건축현황 및 개선방향에 관한 연구 - 충청북도 노인요양시설을 중심으로 -)

  • Lee, Wan-Geon
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.3
    • /
    • pp.242-250
    • /
    • 2010
  • Recently, the long-term care insurance for the elderly was carried out according to the elderly is increased rapidly and the formation of sympathy that a nation and society try commonly to share health and welfare promotion of the elderly. The purpose of this study is to analyze the present status of nursing home after that the long-term care insurance is enforced in chungcheongbuk-do and to utilize as basic data. The study limited its survey to those facilities that refer to the Ministry of Health and Welfare data, that had the capacity of more than 50 people. The result are as followings. Firstly, most of the nursing home were located on the outskirts of the city. But it must be constructed in the city center if the recent deinstitutionalization trend is reflected. Secondly, notwithstanding the provisions of the Elderly Welfare Law, if the Livability and amenity are considered, the plan of a single or a twin room is needed. The ondol(溫突) system bedroom for the safety of the elderly had to be planned and for the color planning of a bedroom, a heating, the furniture, the form of a door, corridors, etc. should be partly improved. The fastener in which it is appropriate for the main exit, a stair, an elevator, the lighting device, and etc. is needed and the installation of a wandering path for the dementia patient and etc. is required. Thirdly, most of the dining room arranged on the first floor but it is not nearly used and it used for employee or the other use. Therefore, we have to consider the system in which it can deliver the meal to a bedroom. If the smell of the elderly and etc. is considered, the sufficient height of the floor should be reflected for the ventilation equipment. Lastly, The improvement of the existing law are required.

BellaGel breast implant: 6-Year results of a prospective cohort study

  • Oh, Joon Seok;Jeong, Jae Hoon;Myung, Yujin;Oh, Jeongseok;Kang, Shin Hyeok;Park, Eonju;Kim, Ara;Bang, Sa Ik;Heo, Chan Yeong
    • Archives of Plastic Surgery
    • /
    • v.47 no.3
    • /
    • pp.235-241
    • /
    • 2020
  • Background This is the first clinical study conducted among Asian women using breast implants manufactured by an Asian company. Four-year data regarding the safety and efficacy of BellaGel breast implants have already been published, and we now report 6-year data. Methods This study was designed to take place over 10 years. It included 103 patients who underwent breast reconstruction or augmentation using BellaGel breast implants. The rates of implant rupture and capsular contracture were measured and analyzed to evaluate the effectiveness of the breast implant. Results At patients' 6-year postoperative visits, the implant rupture and capsular contracture rates were 1.15% and 2.30%, respectively. The implant rupture rate was 3.77% among reconstruction cases and 0% among augmentation cases. The capsular contracture rate was 5.66% among reconstruction cases and 0.83% among augmentation cases. Conclusions The 6-year data from this planned 10-year study suggest that the BellaGel cohesive silicone gel-filled breast implant is an effective and safe medical device that can be used in breast reconstruction and augmentation.

A Study on the Development of Web-based Preventive Maintenance System for the Driverless Rubber-Tired K-AGT (한국형 무인운전 고무차륜 AGT 시스템의 유지보수를 위한 신뢰성 기반의 고장 예방정비 시스템 개발에 관한 연구)

  • Son, Young-Tak;Chun, Hwan-Kyu;Uhm, Ho-Young;Lee, Ho-Yong;Han, Seok-Youn;Suh, Myung-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.5
    • /
    • pp.36-47
    • /
    • 2010
  • The Korean Railroad Research Institute (KRRI) has developed the rubber tired AGT system (Model: K-AGT) between 1999 and 2005. The K-AGT is a light rail transit system does not require a driver and generally operates on an elevated railroad for transporting passengers. Accidents caused by driverless vehicles can severely affect social confidence, safety and economy therefore, it is very important to minimize the occurrences of such faults, and to accurately perform detailed maintenance tasks and thoroughly investigate the cause of any repeated failures. This research develops the web-based Preventive Maintenance (PM) system for the KAGT train system. The framework of the PM system is based on performing a reliability analysis and a failure mode effects analyses (FMEA) procedure on all the sub-systems in the K-AGT system. Out of the devices that have a low reliability, the high failure ranked devices are included high in the list for performing the overall maintenance plans. Through registration of historical failure data, the reliability indexes can be updated. Such a process is repeated continuously and can achieve very accurate predictions for device operational life times and failure rates. Therefore, this research describes the development of the overall PM system consists of a reliability analysis module, a failure mode effect analysis module, and maintenance request module.

Analysis and Test for Turn-buckle of Capacity for Measuring Tensile Force (용량별 인장력 측정용 턴버클의 해석 및 실험)

  • Shin, Kyung-Jae;Lee, Swoo-Heon;Lee, Hee-Du
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.6
    • /
    • pp.715-724
    • /
    • 2011
  • A turn buckle inserted between tension members that sustain the structural loads in a suspension structure system is a device that is capable of adjusting the tensile force. The tension member is an important element of a tension structure, but no simple and economical method of measuring a tensile force applied to members has been proposed yet. Thus, a turn buckle for measuring the tensile force in a tension member was developed in this study. The turn buckles of the measurement limit loads of 100kN, 200kN, and 300kN were tested through a theoretical analysis and a finite element analysis. There was no significant difference in the results of the theoretical analysis, FEA, and the test. In addition, the ultimate strength of the turn buckle using FEA showed that a new turn buckle is sufficiently safe to use even when there is a five-times overload in the measurement limit load.

Parameter Estimation and Reliability Analysis Using Bayesian Approach for Bolted Joint and O-ring Seal of Solid Rocket Motor (고체 로켓 모터의 체결 볼트와 오링에 대한 베이지안 접근법 기반 모수 추정과 신뢰성 해석)

  • Gang, Jin Hyuk;Choi, Joo Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.11
    • /
    • pp.1055-1064
    • /
    • 2017
  • Since a device such as a rocket motor requires very high reliability, a reasonable reliability design process is essential. However, Korea has implemented a design method for applying a safety factor to each component. In classic reliability analysis, input variables such as mean and standard deviation, used in the limit state function, are treated as deterministic values. Because the mean and standard deviation are determined by a small amount of data, this approach could lead to inaccurate results. In this study, reliability analysis is performed for bolted joints and o-ring seals, and the Bayesian approach is used to statistically estimate the input variables. The estimated variables and failure probability, calculated by the reliability analysis, are derived in the form of probability distributions.

Effectiveness of the Verif $EYE^{TM}$ machine -vision technology for complying with reducing microbial indicator counts on beef carcasses

  • Lee, Jeong-Ah;Kim, Sa-Hyun;Lee, Sang-Koan;Kim, Gi-Cheol;Oh, Hye-Won;Jung, Tae-Nam;Lee, Yang-Soo;Jung, Chang-Jin;Jang, Won-Hyuck
    • Korean Journal of Veterinary Service
    • /
    • v.30 no.2
    • /
    • pp.191-196
    • /
    • 2007
  • The slaughter process for cattle will inevitably transfer some bacteria onto the carcasses. The goal of food safety programs is to minimize and effectively remove this contamination. This study was attempted by the Verif $EYE^{TM}$ machine-vision technology that might be useful for reducing microbial indicator counts and could reduce the contamination chance of E coli O157:H7 and Salmonella spp on beef carcasses. For the evaluation of the effectiveness of the Verif $EYE^{TM}$ technology, 80 samples were examined by the inspection device over 15 days. On an examination of FDS-positive samples compared to negative controls from the same carcasses, aerobic plate counts were bigger than the negative control samples (5.26 vs 4.60 log). Enterobacteriaceae counts were greater on the positive samples than the corresponding negative control samples (2.07 vs 1.17log). There was a consistent correlation between samples detected by the Verif $EYE^{TM}$ system with detectable counts. For example, 100% of positive samples had detectable APC and 91.2% of positive samples had detectable TCC. Therefore, if areas detected as positive for contamination by the Verif $EYE^{TM}$ system were removed from the carcasses, significant sources of microbial contamination will be reduced for objective compliance with HACCP. This results suggest that the use of Verif $EYE^{TM}$ machine-vision technology might be useful for reducing microbial indicator counts (APC, TCC) and could help reduce the risk of presence of E coJi O157:H7 and Salmonella spp on Beef carcasses.

Comparison of Analgesic Efficacy and Side Effects between Continuous Epidural Morphine-Bupivacaine and Intravenous Nalbuphine Administration for Analgesia after Cesarean Section (제왕절개술후 통증치료를 위한 지속적 경막외 Morphine-Bupivacaine 주입법과 정맥내 Nalbuphine 주입법의 진통효과와 부작용의 비교)

  • Paek, Keum-Cheol;Kim, Sang-Hyun;Kim, Kee-Seong
    • The Korean Journal of Pain
    • /
    • v.10 no.2
    • /
    • pp.196-202
    • /
    • 1997
  • Background: Various pain treatments have been administered to relieve patients suffering from postoperative pain. Among these, epidural or intravenous opiate administration is by far the most widly applied treatment in recent times. However it was our objective to device a more effective and safe means of postoperative analgesia. Methods: We studied 110 healthy pregnant women scheduled for delivery by elective cesarean section. EPI(epidural)-group is administered morphine 1.5 mg and 0.25% bupivacaine 8 ml as bolus dose, then, a mixture of morphine 6 mg and 0.125% bupivacaine 95 ml as continuous dose via epidural route. IV(intravenous)-group is administered nalbuphine 6~7 mg as bolus dose and nalbuphine 60~70 mg with 0.9% normal saline 90 ml as continuous dose via intravenous route, at the rate of 2 ml/hr for 2 days. We compared the analgesic efficacy and side effects of these two groups using VAS pain score and time duration of constant pain level. Results: VAS pain score was similar between the two groups, but pain duration was significantly shorter in EPI-group. Incidence of pruritus was significantly lower with the IV-group, of nausea and vomiting were similar for both groups, no respiratory depression for either groups. Conclusions: Although the EPI-group had better analgesic efficacy, the IV-group had lower incidence of side effects, and simplicity and safety methods of operation. Therefore, We propose further research and consideration of administering the kinds and doses of those medications prescribe to the IV group in conjunction with other drugs for safer and better efficacy of postoperative analgesia.

  • PDF

The Effect of Postoperative Propacetamol on Acute Pain and Endocrine-Metabolic Response in Gynecological Surgery (부인과 수술 후 통증관리에 있어서 프로파세타몰의 모르핀 절감 및 내분비 대사에 대한 효과)

  • Han, Tae-Hyung;Seo, Jae-Wan;Shin, Baek-Hyo;Son, Jong-Chan
    • The Korean Journal of Pain
    • /
    • v.10 no.2
    • /
    • pp.170-178
    • /
    • 1997
  • Background: The analgesic efficacy and safety of propacetamol, an injectable prodrug of acetoaminophen, in combination with intravenous morphine PCA were studied in 40 patients after gynecological surgery requiring lower abdominal incision. Methods: Using a double-blind, randomized, parallel-group design, the effects of four(every 6 hr) intravenous injections of 2 g propacetamol(=1 g acetoaminophen) were compared with four injections of placebo(PL) immediately after surgery. Efficacy of cumulative dose of morphine and number of boluses requested was assessed over 24 hours by automated recording on the PCA device. It was assessed on pain scores rated on a ten-point verbal scale along with vital signs, $K^+$, glucose, BUN, creatinine, PT and PTT were measured along with stress hormones(epinephrine, norepinephrine and cortisol). Results: There were no differences in demographic data between two groups. Propacetamol group demonstrated approximately 21% morphine sparing effect compared to placebo group($33.1{\pm}10.4$ mg vs $41.4{\pm}8.0$ mg). No significant differences noted in $K^+$, glucose, BUN, Creatinine, PT and PTT levels. There were significant increases in norepinephrine and cortisol in placebo group postoperatively, compared to preoperative values. At the same time, propacetamol group also showed significant changes in these hormones. Both group revealed high degree of patient satisfaction. Conclusion: Propacetamol showed significant morphine sparing effect to some degree. Side effects were much less in propacetamol group with subsequently high patient satisfaction. The secretion of stress hormone were not blocked by postoperative propacetamol injections. Authors concluded that propacetamol should be considered as an excellent adjuvant analgesics in postoperative pain control in opioid patient controlled analgesia.

  • PDF

Environment Corresponding Package by Quantitative Mixing System with Functional Inorganic Material and Polyolefin Resin (기능성 무기물과 폴리올레핀계 수지의 정량적 혼합시스템에 의한 환경대응형 포장소재 개발)

  • Kim, Hi-Sam;Lim, Hyun-Ju;Park, Young-Mi
    • Textile Coloration and Finishing
    • /
    • v.21 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • A lot of research has been made over the recent decade to develop testing packages with antimicrobial properties to improve food safety. In this study, a new method, experimental device and technology for environmental corresponding packages of polypropylene (PP) film has been developed to provide effective temperature buffering during the transport/long-term storage of grains or foodstuffs from the supplier to the market. This quantitatively optimized mixing system enabled to produce PP films with the 700$\sim$1,400d (width;1.5$\sim$3mm, thickness;0.01$\sim$0.5mm). In the whole mixing systems, the finely-granulated inorganic illite and PP virgin chip for master batch (M/B) chip was calculated by digital measurement methods, and then the M/B chip for PP film was adapted through a air jet and PP grinding method. The prepared PP film was characterized with tensile strength and elongation, far infrared radiation (FIR) emissivity, antimicrobial activity and deodorization properties. The results revealed that the two differently grain-sized illite could be show homogeneously dispersed on PP chip surface, and as the increasing of illite content, the FIR emissivity and the anion emission rate of film was increasingly improved. In both of 325 and 1,500 mesh-sized illite contained PP chip, of course the antimicrobial activity was good. But the ultimate deodorization rate for ammonia gas of PP film were found to be approximately the same.