• Title/Summary/Keyword: Safety Design

Search Result 9,642, Processing Time 0.051 seconds

Developing a General Recycling Method of FRP Boats (FRP선박의 범용 재활용을 위한 재처리시스템의 연구)

  • Yoon, Koo-Young
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.1
    • /
    • pp.29-34
    • /
    • 2009
  • For several decades, many researchers have been involved in developing recycling methods for FRP boats. There are four basic classes of recycling covered in the literature. Despite of environmental problems(safety hazards), mechanical recycling of FRP boats, which involves shredding and grinding of the scrap FRP, is one of the simpler and more technically proven methods than incineration, reclamation or chemical ones. Because FRP is made up of reinforced fiber glass, it is very difficult to break into pieces. It also leads to secondary problem in recycling process, such as air pollution and unacceptable shredding noise level. Another serious problem of mechanical FRP recycling is very limited reusable applications for the residue. This study is to propose a new and efficient method which is more wide range applications and environment friendly waste FRP regenerating system. New system is added with the cyclone sorting machine for airborne pollutions and modified cutting system for several glass fiber chips sizes. It also has shown the FRP chip fiber-reinforced concrete and fiber-reinforced secondary concrete applications with the waste FRP boat to be more eligible than existing recycling method.

  • PDF

Evaluation of Interlayer Shear Properties and Bonding Strengths of a Stress-Absorbing Membrane Interlayer and Development of a Predictive Model for Fracture Energy (덧씌우기 응력흡수층에 대한 전단, 부착강도 평가 및 파괴에너지 예측모델 개발)

  • Kim, Dowan;Mun, Sungho;Kwon, Ohsun;Moon, Kihoon
    • International Journal of Highway Engineering
    • /
    • v.20 no.1
    • /
    • pp.87-95
    • /
    • 2018
  • PURPOSES : A geo-grid pavement, e.g., a stress-absorbing membrane interlayer (SAMI), can be applied to an asphalt-overlay method on the existing surface-pavement layer for pavement maintenance related to reflection cracking. Reflection cracking can occur when a crack in the existing surface layer influences the overlay pavement. It can reduce the pavement life cycle and adversely affect traffic safety. Moreover, a failed overlay can reduce the economic value. In this regard, the objective of this study is to evaluate the bonding properties between the rigid pavement and a SAMI by using the direct shear test and the pull-off test. The predicted fractural energy functions with the shear stress were determined from a numerical analysis of the moving average method and the polynomial regression method. METHODS : In this research, the shear and pull-off tests were performed to evaluate the properties of mixtures constructed using no interlayer, a tack-coat, and SAMI with fabric and without fabric. The lower mixture parts (describing the existing pavement) were mixed using the 25-40-8 joint cement-concrete standard. The overlay layer was constructed especially using polymer-modified stone mastic asphalt (SMA) pavement. It was composed of an SMA aggregate gradation and applied as the modified agent. The sixth polynomial regression equation and the general moving average method were utilized to estimate the interlayer shear strength. These numerical analysis methods were also used to determine the predictive models for estimating the fracture energy. RESULTS : From the direct shear test and the pull-off test results, the mixture bonded using the tack-coat (applied as the interlayer between the overlay layer and the jointed cement concrete) had the strongest shear resistance and bonding strength. In contrast, the SAMI pavement without fiber has a strong need for fractural energy at failure. CONCLUSIONS : The effects of site-reflection cracking can be determined using the same tests on cored specimens. Further, an empirical-mechanical finite-element method (FEM) must be done to understand the appropriate SAMI application. In this regard, the FEM application analy pavement-design analysis using thesis and bonding property tests using cored specimens from public roads will be conducted in further research.

Serum Concentration and Exposure History of Dioxins and Organochlorine Pesticides among Residents around the Camp Carroll Area (캠프캐럴 인근 주민에서 다이옥신류 및 유기염소계 농약의 혈중 농도 및 노출력)

  • Bae, Sang Geun;Kim, Geun-Bae;Cho, Yong-Sung;Lee, Yu-mi;Lee, Duk Hee;Yang, Wonho;Ju, Young-Su;Lee, Kwan;Min, Young-Sun;Lim, Hyun-Sul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.277-285
    • /
    • 2016
  • Objectives: This study was performed in order to evaluate whether 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) could be detected among residents living near Camp Caroll in Waegwan and whether serum concentrations of dioxins, including 2,3,7,8-TCDD, and organochlorine pesticides (OCPs) are associated with length of residence. Methods: Study subjects totaled 113 (for dioxins) and 190 (for OCPs) adults who were selected from participants in a medical investigation. Serum concentrations of dioxins and OCPs were measured using HRGC/HRMS. Information on length of residence was obtained through questionnaires. Results: 2,3,7,8-TCDD was not detected in serum among all subjects. When length of residence was classified as a categorical variable, after adjusting for confounding variables, only residents living in Waegwan for 40 years or longer tended to have high total TEQ values and 2,3,4,7,8-PeCDF with marginal significances. There was no dose-response relation between length of residence and serum concentrations of these chemicals. In multiple regression models with continuous values of the length of residence, total TEQ value and 1,2,3,4,6,7,8-HpCDF were positively associated with length of residence. However, they explained about 3-5% of total variations of serum concentrations of these compounds, while age, consumption of fatty fish, body mass index, alcohol drinking, and cigarette smoking were main variables affecting serum concentrations of dioxins or OCPs. Conclusions: In the current study, high concentrations of certain compounds were mainly observed among persons who lived in Waegwan for at least for 40 years without a dose-response relation. Therefore, it seems difficult to conclude that length of residence meaningfully contributed to the current serum concentrations of dioxins or OCPs among residents in Waegwan. However, considering the half-life of 2,3,7,8-TCDD and indirect exposure routes, the limitations of the current study design should be considered in the interpretation of the study findings.

Comparison of the Activities Satisfaction Factors between Volunteer Firefighters and General Volunteers: Focusing on a Resident of Sejong City (의용소방대원과 자원봉사자의 활동만족도에 미치는 영향요인 비교 연구: 세종특별자치시 거주 주민을 중심으로)

  • Lee, Wonjoo;Lee, Chang-Seop
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.89-100
    • /
    • 2017
  • This study compared the activities satisfaction factors between volunteer firefighters and general volunteers in Sejong City. For this purpose, 112 volunteer firefighters and 227 general volunteers working in Sejong City were surveyed. In the questionnaire, the independent variable was the motivations, the interpersonal relationships, and the rewards and the dependent variable was the activities satisfaction. The reliability of the survey data in questionnaire design was analyzed by the SPSS 20.0 win program. The factor of the motivations, interpersonal relationships, and rewards had a significant positive influence on the activities satisfaction of volunteer firefighters and general volunteers (<0.05). The activities satisfaction of the volunteer firefighters was influenced in the order of the motivations, rewards, interpersonal relationships, and activities satisfaction of the general volunteers was influenced in order of the motivations, interpersonal relationships, and rewards.

Prediction of Occupant Load Density using People Counting System in Discount Stores (무인계수시스템을 이용한 대형할인점의 재실자밀도 예측)

  • Seo, Dong-Goo;Hwang, Eun-Kyoung
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.53-59
    • /
    • 2017
  • The purpose of this study is to verify the suitability of the current standards by predicting the density of the occupant load density for discount stores. An internal data survey as well as an actual survey using a People Counting System (PCS) were employed to ascertain the number of occupants and 95% confidence interval of nationwide discount stores. According to the results of the actual survey, the time and days on which the maximum number of occupants were reached was from 16:00 to 18:00 and Christmas Eve and the weekend before New Year's Day, respectively. From the results of the maximum number of occupants, a regression equation was derived from the relationship between the internal data and the amount of sales, and this equation was verified in a previous study. Thus, the internal data of 50 discount stores were analyzed using this process. As a result, the 95% confidence interval was determined to be $2.7{\sim}2.9m^2/pers.$ and the error level was not large compared to the domestic and foreign standards. Therefore, this study proposes that a conservative estimate of the standard occupant load density for discount stores is $2.7m^2/pers.$

Analysis on Ventilation Efficiency of Standard Duck House using Computational Fluid Dynamics (전산유체역학을 이용한 표준 오리사 설계안에 대한 환기효율성 분석)

  • Yeo, Uk-Hyeon;Jo, Ye-Seul;Kwon, Kyeong-Seok;Ha, Tae-Hwan;Park, Se-Jun;Kim, Rack-Woo;Lee, Sang-Yeon;Lee, Seung-No;Lee, In-Bok;Seo, Il-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.5
    • /
    • pp.51-60
    • /
    • 2015
  • In Korea, 69.4 % of duck farms had utilized conventional plastic greenhouses. In this facilities, there are difficulties in controlling indoor environments for raising duck. High rearing density in duct farms also made the environmental control difficult resulting in getting more stressed making their immune system weaker. Therefore, a facility is needed to having structurally enough solidity and high efficiency on the environmental control. So, new design plans of duck house have recently been conducted by National Institute of Animal Science in Korea. As a study in advance to establish standard, computational fluid dynamics (CFD) was used to estimate the aerodynamic problems according to the designs by means of overall and regional ventilation efficiencies quantitatively and qualitatively. Tracer gas decay (TGD) method was used to calculate ventilation rate according to the structural characteristics of duck houses including installation of indoor circulation fan. The results showed that natural ventilation rate was averagely 164 % higher than typically designed ventilation rate, 1 AER ($min^{-1}$). Meanwhile, mechanically ventilated duck houses made 81.2 % of summer ventilation rate requirement. Therefore, it is urgent to develop a new duck house considering more structural safety as well as higher efficiency of environmental control.

Enhancing Connectivity of Guiding Points at Road Signs (도로표지 안내지명의 연계성 확보 방안)

  • Kim, Eung-Cheol;Lee, Tae-Yoon;Kwon, Young-In
    • International Journal of Highway Engineering
    • /
    • v.8 no.4 s.30
    • /
    • pp.37-47
    • /
    • 2006
  • The road sign is one of street furnitures functioning to guide directions for drivers. The road sign should be employed and designed to help drivers find their destinations easily and accurately. It is obvious that the road sign is one of the main components that enhance efficiency and safety of driving environments. The current way of guiding strategy at road signs in Korea is a system for mainly guiding 'points' although a new system guiding 'road names' and 'street numbers' with the introduction of new address system is now being introduced on urban areas. When the regional territory management offices and local governments try to employ current road sign systems, they are supposed to follow the sign regulations which contains standard project processes, selection methods of guiding points, character size and design, and location selection for each road sign. However, the current road sign regulations are very complex to understand and unclear for a person in charge to do tasks described above. Especially, selection process and criteria of guiding points are cumbersome and controversial. Furthermore, non sufficient ways of selecting guiding points considering road functions and geographic characteristics decrease the connectivity of guiding points. This study develops enhanced ways of increasing connectivity of successive guiding points through three case studies. Developed ways will help highway agencies and officials understand how to improve the connectivity of road signs.

  • PDF

Inelastic Time History Analysis of a Five-Story Steel Framed Structure Considering Rigidity of TSD Connection (TSD 접합부의 강성을 고려한 5층 철골골조구조물의 비탄성 시간이력해석)

  • Kang, Suk-Bong;Lee, Jae-Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.3
    • /
    • pp.281-291
    • /
    • 2010
  • In this study, a five-story steel frame was designed in accordance with KBC2005 to evaluate the effects of the beam-column connection on the structural behavior. The connections were designed as fully rigid and semi-rigid. The fiber model was used to describe the moment-curvature relationship of the steel beam and the column, the power model for the moment-rotation angle of the semi-rigid connection and the three-parameter model for the hysteretic behavior of the steel beam, column, and connection. The structure was idealized as separate 2-D frames and as connected 2-D frames. The peak ground accelerations of four earthquake records were modified in a time-history analysis for the levels of the mean return period and for the maximum base-shear force in a pushover analysis. The top story displacement, base-shear force, story drift, demanded ductility ratio for the semi-rigid connection, maximum bending moment of the column, beam, and connection, and distribution of the plastic hinge were examined in the time-history analysis. The frame with the semi-rigid connection yielded a lower base-shear force, less magnitude, and increasing ratio in the bending moment of the column, beam, and connection than the frame with a fully rigid connection. The TSD connection was deemed to have secured the economy and safety of the sample structure that was subjected to seismic excitation for the Korean design level.

The Effect of Psychological Factors of Speeding Behavior Using a Driving Simulator (Focused on Speeding Intention) (차량시뮬레이터를 이용한 과속운전의 심리적 요인 연구 (과속의도를 중심으로))

  • Ryu, Jun-Beom;Sin, Yong-Gyun;Park, Je-Jin
    • Journal of Korean Society of Transportation
    • /
    • v.29 no.1
    • /
    • pp.39-46
    • /
    • 2011
  • Speeding is a major cause of traffic accidents that affects the safety of pedestrians and harms drivers and their families, property and mental health. However, most researches on speeding behavior have been conducted by survey method, so the relationship between cause and effect is not clear. The reliability of the research cannot be carefully examined because most researches involve retrospective methods. It is clear that conducting experimental research is important for overcoming these limitations, but it is impossible to perform tests with real cars in real traffic situations due to the inability to control situational factors (e.g., other vehicles, traffic signal) which affect participants' behavior. A car simulator experiment was designed and the theory of planned behavior was applied to the experiment. Each participant was grouped and assigned to either high speeding intention group or low speeding intention group according to their levels of speeding intention and analyzed the difference of driving behavior indexes between two groups. The results revealed statistically significant differences between two groups on driving speed, speeding frequency, and accelerator pressure deviation. Finally, the limitations and the implications of this study were discussed.

Safety Analysis of Storm Sewer Using Probability of Failure and Multiple Failure Mode (파괴확률과 다중파괴유형을 이용한 우수관의 안전성 분석)

  • Kwon, Hyuk-Jae;Lee, Cheol-Eung
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.11
    • /
    • pp.967-976
    • /
    • 2010
  • AFDA (Approximate Full Distribution Approach) model of FORM (First-Order Reliability Model) which can quantitatively calculate the probability that storm sewer reach to performance limit state was developed in this study. It was defined as a failure if amount of inflow exceed the capacity of storm sewer. Manning's equation and rational equation were used to determine the capacity and inflow of reliability function. Furthermore, statistical characteristics and distribution for the random variables were analyzed as a reliability analysis. It was found that the statistical distribution for annual maximum rainfall intensity of 10 cities in Korea is matched well with Gumbel distribution. Reliability model developed in this study was applied to Y shaped storm sewer system to calculate the probability that storm sewer may exceed the performance limit state. Probability of failure according to diameter was calculated using Manning's equation. Especially, probability of failure of storm sewer in Mungyeong and Daejeon was calculated using rainfall intensity of 50-year return period. It was found that probability of failure can be significantly increased if diameter is decreased below the original diameter. Therefore, cleaning the debris in sewer pipes to maintain the original pipe diameter should be one of the best ways to reduce the probability of failure of storm sewer. In sewer system, two sewer pipes can flow into one sewer pipe. For this case, probability of system failure was calculated using multiple failure mode. Reliability model developed in this study can be applied to design, maintenance, management, and control of storm sewer system.