• Title/Summary/Keyword: Safety Circuit Design

Search Result 136, Processing Time 0.024 seconds

A Study on the Optimal Design of Soft X-ray Ionizer using the Monte Carlo N-Particle Extended Code (Monte Carlo N-Particle Extended 코드를 이용한 연X선 정전기제거장치의 최적설계에 관한 연구)

  • Jeong, Phil hoon;Lee, Dong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.34-37
    • /
    • 2017
  • In recent emerging industry, Display field becomes bigger and bigger, and also semiconductor technology becomes high density integration. In Flat Panel Display, there is an issue that electrostatic phenomenon results in fine dust adsorption as electrostatic capacity increases due to bigger size. Destruction of high integrated circuit and pattern deterioration occur in semiconductor and this causes the problem of weakening of thermal resistance. In order to solve this sort of electrostatic failure in this process, Soft X-ray ionizer is mainly used. Soft X-ray Ionizer does not only generate electrical noise and minute particle but also is efficient to remove electrostatic as it has a wide range of ionization. X-ray Generating efficiency has an effect on soft X-ray Ionizer affects neutralizing performance. There exist variable factors such as type of anode, thickness, tube voltage etc., and it takes a lot of time and financial resource to find optimal performance by manufacturing with actual X-ray tube source. MCNPX (Monte Carlo N-Particle Extended) is used for simulation to solve this kind of problem, and optimum efficiency of X-ray generation is anticipated. In this study, X-ray generation efficiency was measured according to target material thickness using MCNPX under the conditions that tube voltage is 5 keV, 10 keV, 15 keV and the target Material is Tungsten(W), Gold(Au), Silver(Ag). At the result, Gold(Au) shows optimum efficiency. In Tube voltage 5 keV, optimal target thickness is $0.05{\mu}m$ and Largest energy of Light flux appears $2.22{\times}10^8$ x-ray flux. In Tube voltage 10 keV, optimal target Thickness is $0.18{\mu}m$ and Largest energy of Light flux appears $1.97{\times}10^9$ x-ray flux. In Tube voltage 15 keV, optimal target Thickness is $0.29{\mu}m$ and Largest energy of Light flux appears $4.59{\times}10^9$ x-ray flux.

A study on the design of a trumpet horn for automobiles based on acoustic reactance at the horn throat (혼 입구에서의 음향 리액턴스에 근거한 자동차용 트럼펫 혼의 설계 연구)

  • Junsu Lee;Woongji Kim;Daehyun Kim;Dongwook Yoo;Wonkyu Moon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.1
    • /
    • pp.39-48
    • /
    • 2024
  • A car horn serves a crucial safety role as a means of communication between drivers and a part that alerts pedestrians in advance. While previous studies have utilized finite element method and electric circuit model to simulate and analyze characteristics of the car horns, there remains a lack of research on design methods of a trumpet horn. This paper presents a design approach that predicts the operating frequency based on the acoustic reactance at the throat of the horn, once the vibrating part is determined. We deal with a horn combining both an exponential horn and a waveguide in the acoustic section, and confirm that the acoustic reactance at the horn throat measured by impedance tube experiment agrees well compared with the numerical result obtained using the finite element method. The resonance frequency of the car horn is predicted using the COMSOL Multiphysics finite element numerical analysis model, and the proposed design method is validated by measuring the operating frequency of the designed horn in a sound pressure experiment. As a result, the resonance measured in a semi-anechoic chamber environment by applying a DC voltage of 12 [V] excluding the holder occurs accurately within a few [Hz] of the design operating frequency. This paper discuss the design method of a trumpet horn from the perspective of the horn's acoustic reactance, and is expected to be useful for designing horn systems.

Effect Analysis of Classical Line TI-21 type Audio Frequency Track Circuit from KTX Sancheon Return Current Harmonics (KTX산천 귀선전류고조파가 일반선 TI-21형 AF궤도회로에 미치는 영향분석)

  • Choi, Jae Sik;Kim, Hie Sik;Park, Ju Hun;Kim, Bun Gon
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.1
    • /
    • pp.38-45
    • /
    • 2016
  • The power transformation system of High Speed rolling stocks like KTX-Sancheon has shown excellent control capacities in the areas of riding comfortability, switching efficiency, safety and energy consumption due to technical developments in power-electronics, high speed & large scale integrated semiconductors and microprocessors. However, harmonics from IGBT, a high speed switching device used in the Convertor & Invertor equipment of rolling stocks have given rise to various problems in transformer substations, signaling systems, data transmission systems and facility monitoring systems. Especially, TI21 non-insulated track circuits have malfunctioned due to the influence of returning current harmonics which were generated at around of integer times of the number of power transformation equipment in the frequency domain. This paper, measures and analyzes various schemes to analyze the traveling path of the returning current harmonics generated due to the relationship between the rolling stocks and track circuits on site. Ultimately, theseschemes will be used to design high speed rolling stocks, AF track circuits and a common grounding network.

IoT-Based Device Utilization Technology for Big Data Collection in Foundry (주물공장의 빅데이터 수집을 위한 IoT 기반 디바이스 활용 기술)

  • Kim, Moon-Jo;Kim, DongEung
    • Journal of Korea Foundry Society
    • /
    • v.41 no.6
    • /
    • pp.550-557
    • /
    • 2021
  • With the advent of the fourth industrial revolution, the interest in the internet of things (IoT) in manufacturing is growing, even at foundries. There are several types of process data that can be automatically collected at a foundry, but considerable amounts of process data are still managed based on handwriting for reasons such as the limited functions of outdated production facilities and process design based on operator know-how. In particular, despite recognizing the importance of converting process data into big data, many companies have difficulty adopting these steps willingly due to the burden of system construction costs. In this study, the field applicability of IoT-based devices was examined by manufacturing devices and applying them directly to the site of a centrifugal foundry. For the centrifugal casting process, the temperature and humidity of the working site, the molten metal temperature, and mold rotation speed were selected as process parameters to be collected. The sensors were selected in consideration of the detailed product specifications and cost required for each process parameter, and the circuit was configured using a NodeMCU board capable of wireless communication for IoT-based devices. After designing the circuit, PCB boards were prepared for each parameter, and each device was installed on site considering the working environment. After the on-site installation process, it was confirmed that the level of satisfaction with the safety of the workers and the efficiency of process management increased. Also, it is expected that it will be possible to link process data and quality data in the future, if process parameters are continuously collected. The IoT-based device designed in this study has adequate reliability at a low cast, meaning that the application of this technique can be considered as a cornerstone of data collecting at foundries.

A Study on Quality Improvement of Electrical Master Box for KUH (한국형 기동헬기 전원분배 제어장치의 품질 향상에 관한 연구)

  • Kim, Young Mok;Jun, Byung Kyu;Jeong, Sang Gyu;Lee, Joo Hyung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.1
    • /
    • pp.71-78
    • /
    • 2017
  • The electrical power system of Korean Utility Helicopter(KUH) is designed as a dual control system to enhance the system safety of aircraft and each system is installed separately at left and right of the aircraft. The system is composed of 2 AC generators, 1 APU generator, 2 Transformer Rectifier Units(TRU), AC/DC Electrical Master Box(AC/DC EMB). The AC/DC EMB, consists of 2 AC EMB and 2 DC EMB, is essential equipment which supply and distribute electric power to the aviation electronics and electrical equipment of KUH. There were defects caused by internal short circuit in AC EMB during the first production phase of the KUH. This paper describes the analysis of the defects, troubleshooting process, root cause, and the solution by design change.

Modeling and Control Method for High-power Electromagnetic Transmitter Power Supplies

  • Yu, Fei;Zhang, Yi-Ming
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.679-691
    • /
    • 2013
  • High-power electromagnetic transmitter power supplies are an important part of deep geophysical exploration equipment. This is especially true in complex environments, where the ability to produce a highly accurate and stable output and safety through redundancy have become the key issues in the design of high-power electromagnetic transmitter power supplies. To solve these issues, a high-frequency switching power cascade based emission power supply is designed. By combining the circuit averaged model and the equivalent controlled source method, a modular mathematical model is established with the on-state loss and transformer induction loss being taken into account. A triple-loop control including an inner current loop, an outer voltage loop and a load current forward feedback, and a digitalized voltage/current sharing control method are proposed for the realization of the rapid, stable and highly accurate output of the system. By using a new algorithm referred to as GAPSO, which integrates a genetic algorithm and a particle swarm algorithm, the parameters of the controller are tuned. A multi-module cascade helps to achieve system redundancy. A simulation analysis of the open-loop system proves the accuracy of the established system and provides a better reflection of the characteristics of the power supply. A parameter tuning simulation proves the effectiveness of the GAPSO algorithm. A closed-loop simulation of the system and field geological exploration experiments demonstrate the effectiveness of the control method. This ensures both the system's excellent stability and the output's accuracy. It also ensures the accuracy of the established mathematical model as well as its ability to meet the requirements of practical field deep exploration.

A Study on the interface of information processing system on Human enhancement fire fighting helmet (휴먼 증강 소방헬멧 정보처리 시스템 인터페이스 연구)

  • Park, Hyun-Ju;Lee, Kam-Yeon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.497-498
    • /
    • 2018
  • In the fire scene, it is difficult to see 1m ahead because of power failure, smoke and toxic gas, even with thermal imaging camera and Xenon searchlight. Analysis of the smoke particles in the fire scene shows that even if the smoke is $5{\mu}m$ or less in wavelength, it is difficult to obtain a front view when using a conventional thermal imaging camera if the visual distance exceeds 1 meter. In the case of black smoke with a particle wavelength of $5{\mu}m$ or more, a space permeation sensor technology using various sensors other than a single sensor is required because chemical materials, gas, and water molecules are mixed. Firefighters need a smoke detection technology for smoke detection and spatial information visualization for forward safety view.In this paper, we design the interface of the information processing system with 32bit CPU core and peripheral circuit. We also implemented and simulated the interface with Lidar sensor. Through this, we provide interface that can implement information processing system of human enhancement fire helmet in the future.

  • PDF

Optimum Condition of Micro Fuse Fusing as a Function Changed Thickness of Thermosetting Ink Epoxy (열경화성 잉크 에폭시의 두께 변화에 따른 마이크로 퓨즈 용단의 최적 조건)

  • Kim, Do-Kyeong;Hwang, Neung-Hwan;Kil, Tae-Hong;Lee, Soo-Hwa;Seo, Dae-Man;Kim, Min-Ho;Kim, Jong-Sick
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.10
    • /
    • pp.623-629
    • /
    • 2014
  • For the semiconductor device safety from over current in the digital electronic circuit system must be surely designed that it's surface mount type micro fuse device. In this paper, We has analysed to the fusing character of micro fuse as a function changed thickness of thermosetting ink epoxy. To the change of thermosetting ink epoxy thickness with in production lot, in the electrically character (fusing test in the 2 multiple over current and 10 multiple over current, surface temperature test in the 1.25 multiple over current) of micro fuse has been tested. According to the electrically character result, changed thickness of thermosetting ink epoxy in designed micro fuse withheld direct effect in both end resistance changes. Also, because high thermal energy in the micro fuse test of over current was occurred to effect such as thermal runaway and explosion. Therefore, screen printing process in the design of micro fuse using thermosetting ink epoxy is very important for production quality improvement.

An Integrated Approach of CNT Front-end Amplifier towards Spikes Monitoring for Neuro-prosthetic Diagnosis

  • Kumar, Sandeep;Kim, Byeong-Soo;Song, Hanjung
    • BioChip Journal
    • /
    • v.12 no.4
    • /
    • pp.332-339
    • /
    • 2018
  • The future neuro-prosthetic devices would be required spikes data monitoring through sub-nanoscale transistors that enables to neuroscientists and clinicals for scalable, wireless and implantable applications. This research investigates the spikes monitoring through integrated CNT front-end amplifier for neuro-prosthetic diagnosis. The proposed carbon nanotube-based architecture consists of front-end amplifier (FEA), integrate fire neuron and pseudo resistor technique that observed high electrical performance through neural activity. A pseudo resistor technique ensures large input impedance for integrated FEA by compensating the input leakage current. While carbon nanotube based FEA provides low-voltage operation with directly impacts on the power consumption and also give detector size that demonstrates fidelity of the neural signals. The observed neural activity shows amplitude of spiking in terms of action potential up to $80{\mu}V$ while local field potentials up to 40 mV by using proposed architecture. This fully integrated architecture is implemented in Analog cadence virtuoso using design kit of CNT process. The fabricated chip consumes less power consumption of $2{\mu}W$ under the supply voltage of 0.7 V. The experimental and simulated results of the integrated FEA achieves $60G{\Omega}$ of input impedance and input referred noise of $8.5nv/{\sqrt{Hz}}$ over the wide bandwidth. Moreover, measured gain of the amplifier achieves 75 dB midband from range of 1 KHz to 35 KHz. The proposed research provides refreshing neural recording data through nanotube integrated circuit and which could be beneficial for the next generation neuroscientists.

Design and Implementation of Portable Electrostatic Meter Applicable to Industrial Site (산업 현장에 적용할 수 있는 휴대형 정전기 측정기 설계 및 구현)

  • Jang, Mun-Seok;Lee, Eung-Hyuk
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.6_2
    • /
    • pp.971-977
    • /
    • 2020
  • In this paper, We propose a portable electrostatic meter which can measure high voltage static electricity caused by friction to prevent fire or explosion accidents in grinding, crushing, power injection, transport, filling, dust removal, painting, and foreign matter removal processes. The proposed device not only shows static electricity strength in 4 steps with respect to distance and voltage but also gives warning with a buzzer, on process facilities that are likely to generate high voltage static electricity due to friction. The device is implemented by filtering the signal detected by the wireless antenna, amplifying the signal by 6 times, and passing the signal through the integrator circuit. Tests are carried out with an electrostatic discharge simulator. And the results show that 4 LEDs are turned on at the distance of 10cm, 3 LEDs at 12cm, 2 LEDs at 13cm, and 1 LED at 15cm, when a fixed voltage of 500V is given. And also, the tests show that the static electricity can be detected at 5cm on 100V, 10cm on 200V, 15cm on 500V, 20cm on 1000V, and 25cm on 1500V. We expect to reduce accidents caused by static electricity by allowing safety managers on fields where fire or explosion accidents can happen to monitor static electricity.