• Title/Summary/Keyword: Safety Circuit Design

Search Result 136, Processing Time 0.023 seconds

The Design of Squib Circuit using Hybrid Interlock (하이브리드 인터락을 적용한 점화회로 설계)

  • Jang, Bu-Cheol;Cho, Kil-Seok;Shin, Jin-Beom;Koo, Bong-Joo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.404-412
    • /
    • 2014
  • We proposed a design method for squib current supply & interlock circuits in guided-missile fire control systems. In order to design squib current supply circuits, various missile squib loads including line resistance and squib devices have to be considered in advance minimizing probability of redesign of circuits and reducing the development cost by implementing the most proper squib current supply circuit. Also, we presented a hardware interlock logic instead of the commonly used software safety logic to improve the safety of guided-missile fire control systems. The proposed squib interlock circuit enhances safety requirements of guided-missile fire control systems. We confirmed that simulation and measurement results of the proposed design method are the same as theoretical analysis results.

Case Study : Application of Specific Evaluation Criteria For Safety Circuit Design of EN ISO 13849-1 (사례 연구 : EN ISO 13849-1의 안전회로 설계를 위한 구체적 평가 기준의 적용)

  • Jung, Hwansuk;Lee, Dongju
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.1
    • /
    • pp.94-101
    • /
    • 2018
  • With the development of industrial technology and science, production and manufacturing facilities have been enhanced and improved, and the importance of the safety of workers has also been regulated and limited by various safety management methods. As a way to secure the safety of the workers from the production facility, the fail-safe and fool-proof methods are now being applied. Any possible insecure behavior and unsafe conditions can be removed by adopting the standards and specifications that are now secure the safety of workers and equipment. This research analyzes EN ISO 13849-1 international and European standards during CE certification. In order to secure acceptable reduced risks, the risk assessment process of ISO 12100 and the processes for reducing its risk are applied. In the current ISO 13849-1 standard, the criteria for the required performance level PLr (Required Performance Level) for the applicable risk and safety functions through the risk assessment are subjective and not subdivided. Therefore, the evaluation criteria are likely to cause judge's judgement error due to qualitative judgement. This research focuses on evaluation and acceptable performance level setting for the safety circuit of the equipment. We propose an objective and specific evaluation criteria to secure safety, and the proposed evaluation criteria are applied to the case study of the safety circuit for the equipment. In order to secure the safety of the entire safety circuit, the improvement of the MTTFd and DC level related to the SRP/CS (Safety-Related Parts of Control Systems)' lifetime is required for the future research.

Design for a New Signals Analyzer through the Circuit Modeling Simulation under Severe Accident Conditions (중대사고 조건에서 회로 모델링 모의시험을 통한 새로운 신호분기의 설계)

  • Koo, Kil-Mo;Kim, Sang-Baik;Kim, Hee-Dong;Kang, Hee-Young;Kang, Hae-Yong
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.171-174
    • /
    • 2005
  • The circuit simulation analysis and diagnosis methods are used to instruments in detail when they give apparently abnormal readings. In this paper, a new simulator through an analysis of the important circuits modeling under severe accident conditions has been designed, the realization for a body work instead of the two sorts of the Labview & Pspice as an one order command in the Labview program. The program can be shown the output graph form the circuit modeling as an order commend. The procedure for the simulator design was divided into two design steps, of which the first step was the diagnosis methods, the second step was the circuit simulator for the signal processing tool. It has three main functions which are a signal processing tool, an accident management tool, and an additional guide from the initial screen.

  • PDF

Numerical Analysis of Heat Transfer of a Printed Circuit Boards for Safety Design of Electronic Equipment at Each Design Stage (전자장비 안전설계를 위한 PCB의 설계단계별 열전달 해석)

  • 김재홍;김종일
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.2
    • /
    • pp.22-29
    • /
    • 1998
  • The natural convection cooling of simulated electronic chips located on a printed circuit board(PCB) has been studied by Computer Aided Engineering(CAE). In CAE, 3-dimensional finite element model of simulated electronic chip was made to accomplish heat transfer analysis at each design stage of a printed circuit boards for thermal optimization. The simulated electronic chips are installed protrudent from the plate about 3mm. The materials the plates are epoxy and aluminum. The results show that the chip with relatively high heat generation rates should not be close to each other. It is found, as well that cooling effect for the aluminum plate is superior to the epoxy plate and location of maximum temperature is significantly influenced by the structure variation of PCB. In developing PCB and electronic chips, it's recommended that CAE is very useful to estimate to the distribution of temperature.

  • PDF

Optimization Design for the Use of Mechanical Switch in Z-source DC Circuit Breaker (Z-source 직류 차단기의 기계식 스위치 적용을 위한 최적화 설계)

  • Lee, Hyeon Seung;Lee, Kun-A
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.1
    • /
    • pp.12-19
    • /
    • 2022
  • Circuit breakers are a crucial factor in ensuring the safety of a Direct Current (DC) grid. One type of DC circuit breaker, the Z-source DC circuit breaker (ZCB), uses a thyristor, which is a type of semiconductor switch. In the event of a fault in the circuit, the ZCB isolates the fault by generating a zero crossing current in the thyristor. The thyristor quickly and actively isolates the fault while generating a zero crossing current, but thyristor switch cannot control turn-off and the allowable current is lower than the current of the mechanical switch. Therefore, it is best to use a mechanical switch with a high allowable current capacity that is capable of on/off control. Due to the slow reaction time of mechanical switches, they may not isolate the fault during the zero crossing current time interval created by the existing circuit. In this case, the zero crossing current time can be increased by using the property that hinders the rapid change in the current of the inductor. This paper will explore whether adding system inductance to increase the zero crossing current time interval is a solution to this problem. The simulation of changing inductor and capacitor (LC) of the circuit is repeated to find an optimal change in the zero crossing current time according to the LC change and provides an inductor and capacitor range optimized for a specific load. The inductor and capacitor range are expected to provide optimization information in the form LC values for future applications of ZCB's using a mechanical switch.

The Optimum Design According to Type Analysis of the Safety Circuit Design (LED 조명의 안전회로설계 Type분석에 따른 최적설계)

  • Jang, In-Hyeok;Kim, Jeong-Ho;Lim, Hong-Woo;Oh, Geun-Tae;Choi, Youn-Ok
    • Journal of Applied Reliability
    • /
    • v.16 no.4
    • /
    • pp.331-337
    • /
    • 2016
  • Purpose: The purpose of this study is the analysis of the failure mechanisms effect of circuit design characteristics of the ballast for LED Lamp Methods: Recently, electronic circuit of ballasts for LED lamp are being occurred on various failure mechanisms (whiskers, ion migration, heat dissipation problem, switching element damage) because electronic ballast circuit design characteristics are becoming more and more diverse. Results: we analysis failure mechanisms that occurs in accordance with the circuit design characteristics The ballast for LED lamp were divided into three different types (Type A, Type B, Type C) considering circuit design characteristics (thermal design, PCB patten spacing, element material) and it was experimented in the acceleration test conditions ($85^{\circ}C$, 85% R.H). Conclusion: We confirmed that failure mechanism of the ballast for LED Lamp had occurred differently in accordance with the circuit design characteristics.

A Study on Fault Detection and Fault Device Estimation Method for Cab Cubicle in High Speed Electrical Train (고속전철용 Cab Cubicle의 이상검출과 고장부위 추정에 관한 연구)

  • 장영건;조경환;박계서;최권희
    • Proceedings of the KSR Conference
    • /
    • 2000.05a
    • /
    • pp.188-194
    • /
    • 2000
  • This study is about fault detection and fault area detection of LV circuit in Cab Cubicle system which have control of train to keep safety in High Speed Train. LV circuit is operated with diagnosis system like safety system. In this paper, we suggest a design and an implementation method to detect fault or to detect fault area automatically about LV circuit. The implemented system is tested successfully after implementation of some function. We expect reduction to diagnosis area or repair time by fault area module

  • PDF

A Study on Implementation of LV circuit analysis simulator for Reliability Evaluation (신뢰성 평가를 위한 LV 회로 분석시뮬레이터 구현에 관한 연구)

  • 장영건;조경환;박계서;최권희
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.602-609
    • /
    • 2000
  • This study is concerned with analysis and reliability evaluation of LV circuit in Cab Cubicle system which controls train to keep safety in High Speed Train. LV circuit is operated with diagnosis system as safety system. In this paper, we suggest a design and an implementation method to analyze LV circuit or trace fault area in LV circuit. This simulator uses 28 package modules and examines input and output by equations. So, user can trace where is fault area. The implemented system can be expected to be useful for long term test and evaluation of circuit in high speed train systems. We expect reduction to diagnosis area or repair time by this simulator.

  • PDF

A Study on the Design of ESJ of Jointless Track Circuit (무절연 궤도회로의 ESJ설계에 대한 연구)

  • 김정열;신석균;정용운;이기서;이길영
    • Proceedings of the KSR Conference
    • /
    • 2000.05a
    • /
    • pp.195-201
    • /
    • 2000
  • In this paper propose the new method on desig ESJ(Electrical Separation Joint) of Jointless Track Circuit. ESJ has a capability to saparate track signal electrically but enable connected a track section physically. So It is more proper to high-speed line. Because that demand a critical traveling safety and convient taking a train. In spite of existing ESJ of Jointless Track Circuit, UM7l, S-bond, According to new pole-zero placement and desgining tuining-unit It is possible to prove a independence of track-section and track-signal in new ESJ design of this paper

  • PDF

A Study on the Short-circuit Protection System for Learning Teaching Instruction Using Incandescent Light Bulb (백열전구를 이용한 학습 교구용 단락보호장치에 대한 고찰)

  • Hong-yong Kim
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.4
    • /
    • pp.844-850
    • /
    • 2023
  • Purpose: This paper is about the development of a short-circuit protection power supply device using incandescent bulbs and its application for educational materials. This article, which considers electrical safety and energy conservation at the same time, has many kinds of potential applications for both educational and industrial areas. The above mentioned short-circuit protection power supply device using incandescent bulbs enhances safety and efficiency compared to normal current power supply devices. Additionally, as an educational materials, it can be used for electric safety training, and provides practical electrical safety knowledge on our actual life. Method: Using incandescent bulbs, design new type of short-circuit protection power supply device, and through verifying the function and safety of the device, make new type device, and applying it for an educational tool. Conclusion: This study is to develop new type of power supply device, and verify the possibility of the application for the device as an educational materials. Through this research, show an innovative solution, which contribute to electrical safety and energy conservation, and open the potential possibility on educational and industrial sectors.This kind of research is expected to contributes to enhanced research, and education on electrical safety and energy conservation management.