• Title/Summary/Keyword: Safety Assessment Factor

Search Result 526, Processing Time 0.034 seconds

Seismic Margin Assessment of Concrete Retaining Walls (콘크리트 옹벽의 지진여유도 평가)

  • Park, Duhee;Baeg, Jongmin;Park, Inn-Joon;Hwang, Kyeungmin;Jang, Jungbum
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.7
    • /
    • pp.5-10
    • /
    • 2019
  • In recent Gyeongju and Pohang earthquakes, motions that exceed the design ground motion were recorded. This has led to adjustments to the design earthquake intensity in selected design guidelines. An increment in the design intensity requires reevaluation of all associated facilities, requiring extensive time and cost. Firstly, the seismic factor of safety of built concrete retaining walls are calculated. Secondly, the seismic margin of concrete retaining walls is evaluated. The design sections of concrete walls built at power plants and available site investigation reports are utilized. Widely used pseudo-static analysis method is used to evaluate the seismic performance. It is shown that all concrete walls are safe against the adjusted design ground motion. To determine the seismic margin of concrete walls, the critical accelerations, which is defined as the acceleration that causes the seismic factor of safety to exceed the allowable value, are calculated. The critical acceleration is calculated as 0.36g~0.8g. The limit accelerations are significantly higher than the design intensity and are demonstrated to have sufficient seismic margin. Therefore, it is concluded that the concrete retaining walls do not need to be reevaluated even if the design demand is increased up to 0.3g.

Fall Risk Assessment of the Elderly living in Nursing Home (노인요양시설 거주 노인의 낙상 위험요인 조사 연구)

  • Yang, Sun-Hee;Park, Young-Hae;Cho, Hae-Sook;Baek, Hee-Chong
    • Journal of Home Health Care Nursing
    • /
    • v.12 no.2
    • /
    • pp.1-15
    • /
    • 2005
  • Purpose: This study was conducted to assess the fall risk factors. Method: The subjects were 87 persons who were older than 65 years living at 28 nursing home in Seoul and Gyunggi province. Subjects were interviewed using RAFS II for intrinsic factor and the environmental factor were assessed using a structured questionnaire from Oct. to Dec. in 2004. The data were analyzed by SPSS(ver. 12.0) programs, using descriptive statistics, $x^2$-test, and t-test. Result: The 37.9% of the subjects experienced the fall, and its average number is $1.94\pm1.75$. The Women's experience of the fall was higher than that of the men, but it was no significant difference with gender. There was no significant difference with the age and duration of living. The mean of the intrinsic risk factor was 13.38 in total score 39 points marks on the RAFS II scales. The intrinsic risk factor score of the fallen group 15.71 was significantly higher than the non-fallen group 12.10. The variables of recent fall experience(t=4.72, p=0.000) and urinary dysfunction(t=2.64, p=0.010) was significantly higher than the non-fallen group. The highest variable of the intrinsic factor was the age and the variables of drug intake, balance, chronic disease, recent fall experience, urinary dysfunction were followed in order. The mean of the environmental risk factor was 0.24 points. No significant differences were shown in environmental risk factor between the fallen and the non-fallen groups. To the fallen group, the place of entrance was the highest risky environmental factor. To see in area dimension, the floor surfaces was the highest risky environmental factor and equipment and illumination factor was the following risky elements in order. In the total score of environmental risk factors based on the ares, the fallen group was 0.26 and the non-fallen group was 0.24, but there were no significant differences between the groups. Conclusion: This results suggested that visual protection strategy, set up the safety device in the place of entrance and inner stairway, bathroom and nonskid mat in the nursing home would be contribute to the prevention of the fall for the elderly.

  • PDF

A study on development of disaster-risk assessment criteria for steep slope -Based on the cases of NDMS in Ministry of Interior and Safety- (급경사지 재해위험도 평가 기준 개선 방안 연구 -행정안전부 급경사지 관리시스템 사례를 중심으로-)

  • Suk, Jae-Wook;Kang, Hyo-Sub;Jeong, Hyang-Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.372-381
    • /
    • 2019
  • In this study, the National Disaster Management System (NDMS) was analyzed to evaluate the disaster impact assessment standards for steep slopes. Problems in the assessment methods and systems were discovered, which could be reasons for poor reliability. The disaster-risk evaluation index needs improvement to evaluate various types of retaining walls, such as concrete/reinforced soil walls and reinforcing stone masonry. Additionally, using the same score for overturning, bulging, and efflorescence could be reasons for poor reliability, and different weighting factors are needed. Assessment methods are needed to subdivide the social influence evaluation index while considering environmental conditions of steep slopes, such as railroads and reservoirs. For the evaluation of steep slopes, standards for start and end points of steep slopes should be created for effective management, and disaster impact assessment needs to be performed after redevelopment from an advanced index for protection and reinforcement. These problems were derived from a current evaluation system, so a disaster impact assessment is necessary to supplement the results of this study.

Analysis of Effects on Adoption of a Safety e-Reporting System (안전신고 제도(안전신문고) 도입에 따른 효과 분석)

  • Lee, Jun;Cho, Sangmyeong;Park, Eunmi;Lee, Sanghwa
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.4
    • /
    • pp.27-41
    • /
    • 2019
  • To analyze the effectiveness of the safety e-reporting system, the present study carried out analysis of safety e-reporting data reported between September 2014 and July 2019, and selected items for measuring the effectiveness of safety e-reporting. Using these items, the effects of adopting the reporting system for the four major parking violations was analyzed, alongside an analysis of effects in terms of traffic accidents using the unit model. When we count the securement of the tax revenue through measures such as charging fines as the beneficial factor per case, the estimation of the benefit is around 62,000 KRW per case. Summing the two factors up, the total value of citizen's reports pertaining to the big four parking violations is about 275,000 KRW per case. Most of the reports made through the Safety e-Report system are about traffic and facilities. When we calculate the total annual benefit with the representative reporting value defined with traffic and facilities, the system received a total of 1,164,439 cases from 2014 to 2019, while citizens reported 52,721 cases for the big four parking violations from April to July 2019. As the value of a safety report is around the net benefit for last five years is around 27,340,000,000 KRW.

Assessment of a Pre-conceptual Design of a Spent PWR Fuel Disposal Container (가압경수로형 사용후핵연료 처분용기의 예비 개념설계 평가)

  • Choi, Jong-Won;Cho, Dong-Keun;Lee, Yang;Choi, Heui-Joo;Lee, Jong-Youl
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.1
    • /
    • pp.41-50
    • /
    • 2006
  • In this paper, sets of engineering analyses were conducted to renew the overall dimensions and configurations of a disposal container proposed as a prototype in the previous study. Such efforts and calculation results can provide new design variables such as the inner basket array type and thickness of the outer shell and the lid & bottom of a spent nuclear fuel disposal container. These efforts include radiation shielding and nuclear criticality analyses to check to see whether the dimensions of the container proposed from the mechanical structural analyses can provide a nuclear safety or not. According to the results of the structural analysis of a PWR disposal container by varying the diameter of the container insert, the Maximum Von Mises stress from the 102 cm-container meets the safety factor of 2.0 for both extreme and normal load conditions. This container also satisfies the nuclear criticality and radiation safety limits. This decrease in the diameter results in a weight loss of a container by $\sim20$ tons.

  • PDF

An Experimental Study on the Extinguishing Performance of Sprinkler Heads according to Discharge Coefficient (스프링클러 헤드의 방수상수에 따른 소화성능에 관한 실험적 연구)

  • Hur, Min Noung;Shin, Chang Sub
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.2
    • /
    • pp.32-38
    • /
    • 2018
  • The sprinkler system is a basic fire extinguishing system widely used, but there is a lack of quantitative assessment of its performance. In this study, to evaluate the fire extinguishing performance of the sprinkler head according to the discharge coefficients, experiments were conducted. Experimental sprinkler heads were selected with heads having K50, K80 and K115 water discharge coefficients, and the fire source was assumed to be an indoor fire in Class A Model 1. As experimental results, the time required for the fire chamber to cool down to $200^{\circ}C$ was 26 seconds for the K115 head, 414 seconds for the K80 head, and 481 seconds for the K50 head, so the cooling time of the K115 head was decreased by 94.5% compared to K50 head. In the case of restoring the oxygen concentration to 15%, the K115 head did not decrease below the oxygen concentration of 15%, and the K80 head took 145 seconds and the K50 head took 484 seconds. The lowest oxygen concentration in the fire chamber was 16.1% for the K115 head, 14.33% for the K80 head, and 11.28% for the K50 head, indicating that the K115 head was superior to the K80 and K50 heads by 13.1% and 43.7%, respectively. As the experimental results show, there is big difference in the extinguishing performance depending on the discharge coefficients of the sprinkler head. Therefore, in designing the sprinkler system, the discharge coefficients of the sprinkler head should be selected considering the heat release rate at the installation site and the fire extinguishing characteristics of sprinkler head.

Evaluation of the Effectiveness of Emission Control Measures to Improve PM2.5 Concentration in South Korea (미세먼지 농도 개선을 위한 배출량 저감대책 효과 분석)

  • Kim, Eunhye;Bae, Changhan;Yoo, Chul;Kim, Byeong-Uk;Kim, Hyun Cheol;Kim, Soontae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.3
    • /
    • pp.469-485
    • /
    • 2018
  • On September 26, 2017, South Korean government has established the Particulate Matter Comprehensive Plan to improve Korean air quality by 2022, which aims to reduce annual mean surface $PM_{2.5}$ concentration to $18{\mu}g/m^3$. This study demonstrates quantitative assessment of predicted $PM_{2.5}$ concentrations over 17 South Korean regions with the enforcement of the comprehensive plan. We utilize the Community Multi-scale Air Quality (CMAQ) modeling system with CAPSS 2013 and CREATE 2015 emissions inventories. Simulations are conducted for 2015 with the base emissions and the planned emissions, and impacts from model biases are minimized using the RRF (Relative Response Factor). With effective emission reduction scenario suggested by the comprehensive plan, the model demonstrates that the surface $PM_{2.5}$ concentration may decrease by $6{\mu}g/m^3$ ($23{\mu}g/m^3{\rightarrow}17{\mu}g/m^3$) and $7{\mu}g/m^3$ ($25{\mu}g/m^3{\rightarrow}18{\mu}g/m^3$) for Seoul and South Korea, respectively. The number of high $PM_{2.5}$ days(daily mean>$25{\mu}g/m^3$) also decreases from 21 days to 4 days.

A Study on the Analysis of Hazardous Risk Factors for Component in Hydrogen Station with Water Electrolysis Device (수전해 수소충전소 부품별 유해위험요인 분석)

  • Seo, Doo-Hyoun;Rhie, Kwang-Won;Kim, Tae-Hun
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.33-38
    • /
    • 2019
  • In order to invigoration the hydrogen economy, production of hydrogen needed for hydrogen charging stations and hydrogen fuel cells is needed. Generally, it is reforming used to coal fuel or natural gas. Other technologies include water electrolysis using pure water. Among these water electrolysis technologies, development is mainly carried out using PEM(Polymer Electrolyte Membrane electrolysis). In this study, the company aims to identify potential harmful hazards to PEM electrolysis hydrogen stations in the development stage among hydrogen charging stations. In order to find the hazardous factors in the facilities of the electrolysis and hydrogen charging stations, we were analyzed by Failure Mode & Effect Analysis(FMEA).

Meta-Analysis: Association Between Wrist Posture and Carpal Tunnel Syndrome Among Workers

  • You, Doohee;Smith, Allan H.;Rempel, David
    • Safety and Health at Work
    • /
    • v.5 no.1
    • /
    • pp.27-31
    • /
    • 2014
  • Background: Carpal tunnel syndrome (CTS) is a common work-related peripheral neuropathy. In addition to grip force and repetitive hand exertions, wrist posture (hyperextension and hyperflexion) may be a risk factor for CTS among workers. However, findings of studies evaluating the relationship between wrist posture and CTS are inconsistent. The purpose of this paper was to conduct a meta-analysis of existing studies to evaluate the evidence of the relationship between wrist posture at work and risk of CTS. Methods: PubMed and Google Scholar were searched to identify relevant studies published between 1980 and 2012. The following search terms were used: "work related", "carpal tunnel syndrome", "wrist posture", and "epidemiology". The studies defined wrist posture as the deviation of the wrist in extension or flexion from a neutral wrist posture. Relative risk (RR) of individual studies for postural risk was pooled to evaluate the overall risk of wrist posture on CTS. Results: Nine studies met the inclusion criteria. All were cross-sectional or case-control designs and relied on self-report or observer's estimates for wrist posture assessment. The pooled RR of work-related CTS increased with increasing hours of exposure to wrist deviation or extension/flexion [RR = 2.01; 95% confidence interval (CI): 1.646-2.43; p < 0.01: Shore-adjusted 95% CI: 1.32-2.97]. Conclusion: We found evidence that prolonged exposure to non-neutral wrist postures is associated with a twofold increased risk for CTS compared with low hours of exposure to non-neutral wrist postures. Workplace interventions to prevent CTS should incorporate training and engineering interventions that reduce sustained non-neutral wrist postures.

Measuring Situation Awareness of Operating Team in Different Main Control Room Environments of Nuclear Power Plants

  • Lee, Seung Woo;Kim, Ar Ryum;Park, Jinkyun;Kang, Hyun Gook;Seong, Poong Hyun
    • Nuclear Engineering and Technology
    • /
    • v.48 no.1
    • /
    • pp.153-163
    • /
    • 2016
  • Environments in nuclear power plants (NPPs) are changing as the design of instrumentation and control systems for NPPs is rapidly moving toward fully digital instrumentation and control, and modern computer techniques are gradually introduced into main control rooms (MCRs). Within the context of these environmental changes, the level of performance of operators in a digital MCR is a major concern. Situation awareness (SA), which is used within human factors research to explain to what extent operators of safety-critical systems know what is transpiring in the system and the environment, is considered a prerequisite factor to guarantee the safe operation of NPPs. However, the safe operation of NPPs can be guaranteed through a team effort. In this regard, the operating team's SA in a conventional and digital MCR should be measured in order to assess whether the new design features implemented in a digital MCR affect this parameter. This paper explains the team SA measurement method used in this study and the results of applying this measurement method to operating teams in different MCR environments. The paper also discusses several empirical lessons learned from the results.