• Title/Summary/Keyword: Safe work load

Search Result 42, Processing Time 0.247 seconds

Development of Non-Electric and Delay-Type Explosive Bolt (비전기식 지연형 폭발볼트 개발)

  • Lee YeungJo;Kim DongJin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.9 no.3
    • /
    • pp.60-65
    • /
    • 2005
  • The present work has developed non-electric and delay-type explosive bolt that does not need electric power supply device and has the delay function in the operation. Non-electric power supply system enables separation device system to be minimized. In order to prove the mechanism of the operation, the power of air resistance caused from aviation object used to ignite the initiator. we can be founded from the present work that the changes in the operation load influence directly the ignition of the initiator. The design of non-electric and delay type of explosive bolt is the most suitable for the separation system that is necessary to reduce the velocity of aviation object and safe landing of parachute system.

Measurement of Shoulder Muscle Workload at Various Working Postures (작업자세에 따른 어깨근육의 작업부하 측정)

  • Kim, Jung-Yong;Park, Ji-Soo;Park, Chang-Soon;Phyun, Heung-Kook
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.25 no.2
    • /
    • pp.266-273
    • /
    • 1999
  • The maximum work capacity at various shoulder angles was estimated in terms of joint moment through maximum voluntary contraction (MVC) measurement, and the result was compared to workload computed from 3-D static lifting model (3DSSPP) based upon national institute of safety and health (NIOSH) lifting guideline (1991). The electromyography (EMG) of anterior/posterior deltoid and trapezius muscle was also recorded to study the function of individual muscle during asymmetric shoulder lifting. Psychophysical workload was measured to observe the difference from MVC or biomechanical estimation. An apparatus was constructed for the study and twenty five trials including five flexion angles and five add/abduction angles were performed isometrically. Results indicated that MVC at 30 degree of flexion was the strongest whereas MVC at 120 degree was the weakest. In case of add/abduction, MVC decreased to 77 to 89 % during add/abduction compared to the MVC at neutral position. Regarding the normalized EMG value, a substantial increase was observed at 30 and 60 degree abduction. More importantly, the shoulder moment computed from maximum permissible limit (MPL) was greater than the moment at MVC condition during 30 degree adduction. Current result can be used as a reference information for a safe workplace design to prevent the shoulder from an excessive work load in industry.

  • PDF

A Study on the Safety Improvement of Lifting Purpose Chain Sling (인양용 체인슬링의 안전성 향상 방안 고찰)

  • Jin Woo Lee;Cheol Ho Han;Song Woo Lee;Young Hun Jeon;Chang Hee Lee
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.4
    • /
    • pp.60-67
    • /
    • 2023
  • Various lifting slings are used in domestic industrial sites depending on the purpose, form, and environment. Each sling has its characteristics, and safe lifting work is possible when its performance meets the regulations. Therefore, this study analyzed domestic and foreign regulations and guidelines related to chain slings. It identified significant problems by analyzing the chain-sling-related disaster cases. The current status of chain slings used by various industries and the ways to improve chain sling safety were studied. The major chain sling issues were: 1) employing improper components to chains, 2) having different safety coefficients between the regulation and industrial standards, and 3) using chains unsuitable for lifting purposes. Based on these issues, the following measures were proposed to improve chain sling work safety: 1) revise the safety coefficient requirements under the Regulations on Occupational Safety and Health Standards, 2) disseminate specialized sling courses, and 3) strengthen on-site chain slings-related training. In the future, this study is expected to minimize chain use mistakes by unifying the safety coefficient related to chain slings and recognizing the importance of correctly selecting components employed in the chain.

Effect of Density Variation of High Tenacity PET Interlace Yarn on the Physical Properties of Pack Style Shock Energy Absorber (고강력 PET Interlace Yarn 밀도변화가 Pack Style Shock Energy Absorber의 물성에 미치는 영향)

  • Cho, Jin Won;Kwon, Sang Jun;Choe, Jong Deok;Kim, Sang Tae;Ji, Byung Chul;Yang, Seong Baek;Yeum, Jeong Hyun
    • Textile Coloration and Finishing
    • /
    • v.27 no.2
    • /
    • pp.132-141
    • /
    • 2015
  • Fall-arrest systems(maximum arrest force and allowable free-fall) have been widely applied to provide a safe stop during fall incidents for various industrial activities. Fabric structure affects on the mechanical properties of shock energy absorber. The object of this study is to perform the basic research for the evaluation of the capacity of fall arrest energy absorber in relation to the different interlace yarn density. In this work, pack style energy absorber was prepared by weaving 10 types(Interlace yarn density used high tenacity PET 1000D : 60, 59, 58, 57, 56, 55, 54, 53, 52, 51). The paper presents the results of theoretical investigations of the performance of adjustable absorber during fall arrest. Dynamic load tests based on the EU fall protection equipment standard(CE : EN355:2002) were conducted. Results showed that the maximum arrest force by dynamic load test of energy absorber was satisfied with global standard(below 6,000N). Also, Maximum allowable free-fall of energy absorber showed below 1.75m.

Development of MK $III^{TM}$ Type Large Arctic LNG Carrier

  • Suh, Yong-Suk;Jang, Ki-Bok;Ito, Hisashi;Park, Seung-Mun;Chung, Sung-Wook;Han, Sung-Yong
    • Journal of Ship and Ocean Technology
    • /
    • v.11 no.3
    • /
    • pp.24-38
    • /
    • 2007
  • It is a very challenging work to design large Arctic LNG carrier, since LNG carrier requires high reliability for the structural safety and the environment of Arctic region is known to be very severe. Therefore, special attention should be paid for the verifying the structural safety of LNG career particularly with regard to LNG leakage. In this paper, the safety of the hull structure and cargo containment system of 208K MK $III^{TM}$ type LNG carriers with Arc4 is investigated based on the direct calculation of ice loads as well as wave loads. From the whole investigation, it is clear that the developed vessel - 208K MK $III^{TM}$ type LNG carrier with RMRS Ice class Arc4 - has enough strength and is safe to be operated in Arctic region.

Physiological viewpoint of the recommended safe weights of load for manual materials handling tasks (인력물자취급의 권장안전하중에 대한 생리학적 고찰)

  • 김홍기
    • Journal of the Ergonomics Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.23-36
    • /
    • 1997
  • The objective of this study was to make a comparison of the oxygen consumption rates during the lifting activities and the physiological criteria of the recommended weights of RWL, AL, and MPL by NIOSH Guideline. The physical Work Capacity (PWC) based on the bicycle ergometer was 2562.71ml/min, and the one based on the treadmill was 2874.89ml/min for the college male students of Korea. Lifting activities with four different lifting frequencies(2, 5, 8, 11 lifts/min) for one lifting range from floor to 76cm height were studied. The oxygen consumption rates and the heart rates were measured or recorded while subjects were lifting the weight of RWL, AL, and MPL. The heart rates and the oxygen consumption rates increased as the frequency increased from 2 to lifts/min. However, those slightly decreased at the frequency of 11 lifts/ min. The measured oxygen consumption rates were ranging from 2.3% to 29.6% higher than the physiological criteria 620, 700, and 1000ml/min, respectively, of the RWL, AL, and MPL for all the lifting frequencies (5, 8, 11 lift/min) except 2 lifts/min. It si suggested that the physiological criteria of NIOSH Guideline should be based on the lifting PWC, which can consider the type of lifting activity and the frequency of the task, rather than using the PWC by ergometer or treadmill. The measured oxygen consumption rates were ranging from 13.26% to 40.11% higher than the values estimated using the models by Garg and Kim. From these findings it is suggested that the NIOSH Equation should not be directly applied to Korean without resonable modifications.

  • PDF

The STCW Manila Amendments and its Challenges to the Far East

  • Chae, Chong-Ju
    • Journal of Navigation and Port Research
    • /
    • v.38 no.3
    • /
    • pp.193-202
    • /
    • 2014
  • The comprehensive review of the STCW 1978, as amended in 1995 and associated Code was carried out from 2006 to 2010. These amendments will have a certain degree of impact on Maritime Education and Training(MET) institutes in terms of education and training of seafarer worldwide. Particularly, the Far East region countries are effected more than other regions since they covered about 30% of officers and 37% ratings in the world. In view of these facts this dissertation conceived to analyze the problems in the Far East main seafarer supply countries faced the implementation of "STCW Manila Amendments" To analyze these problems, this dissertation carried out questionnaire research to 7 targeted main MET of major Far East seafarer supply countries. After research this dissertation suggests the possible solutions such as, Joint On-Board Training Center; Joint Asia Maritime E-learning Systems; methods to reducing work-load, ship inspection burden and determine mandatory minimum safety manning standards in a safe way; technical cooperation fund to installation of training equipment; and clarify vague terminology of STCW Manila Amendments, to solve problems identified through the questionnaires.

Chemical-assisted Ultrasonic Machining of Glass by Using HF Substitute Solution (불산대체용액을 이용한 유리의 초음파 가공)

  • 전성건;남권선;김병희;김헌영;전병희
    • Transactions of Materials Processing
    • /
    • v.13 no.3
    • /
    • pp.262-267
    • /
    • 2004
  • Ultrasonic machining has been known as one of the conventional machining methods in the glass fabrication processes. In ultrasonic machining, typically, glass is removed by the impulse energy of the abrasive generated by the ultrasonic power. However, when the machining feature decrease under hundreds of micrometers, as conventional ultrasonic machining uses only the impulse energy of the abrasive, the speed of ultrasonic machining decreases significantly and the surface roughness becomes deteriorated. To overcome this size effect, the chemicals which can erode glasses, such as HF, XF, etc, are added to the slurry. The chemical-assisted ultrasonic machining method, so called, is another alternating effective way for micro machining of glasses. In previous work, we used the hydrofluoric acid (HF) as an additive chemical. But, as the HF solution is too poisonous to be used as a ultrasonic process additive, it is needed to be substituted by other safe chemicals. As results of the machinability comparison of several chemicals, the GST-500F was selected to replace the HF. The GST-500F (pH $4.0{\pm}1.0$) is non-volatile, odorless. During experimental works, it was shown that the machining rate increases 1.5 times faster than the conventional ultrasonic machining. The machining load also decreases. However, the enlargement of the hole diameter and significant tool wear are still the problems to be solved.

Seismic response of bridge pier supported on rocking shallow foundation

  • Deviprasad, B.S.;Dodagoudar, G.R.
    • Geomechanics and Engineering
    • /
    • v.21 no.1
    • /
    • pp.73-84
    • /
    • 2020
  • In the seismic design of bridges, formation of plastic hinges plays an important role in the dissipation of seismic energy. In the case of conventional fixed-base bridges, the plastic hinges are allowed to form in the superstructure alone. During seismic event, such bridges may be safe from collapse but the superstructure undergoes significant plastic deformations. As an alternative design approach, the plastic hinges are guided to form in the soil thereby utilizing the inevitable yielding of the soil. Rocking foundations work on this concept. The formation of plastic hinges in the soil reduces the load and displacement demands on the superstructure. This study aims at evaluating the seismic response of bridge pier supported on rocking shallow foundation. For this purpose, a BNWF model is implemented in OpenSees platform. The capability of the BNWF model to capture the SSI effects, nonlinear behavior and dynamic loading response are validated using the centrifuge and shake table test results. A comparative study is performed between the seismic response of the bridge pier supported on the rocking shallow foundation and conventional fixed-base foundation. Results of the study have established the beneficial effects of using the rocking shallow foundation for the seismic response analysis of the bridge piers.

National Survey of Kangaroo Care Practice, Barriers, Knowledge, and Belief (신생아중환자실 캥거루 케어 전국 실태조사- 간호행위, 장애요인, 간호사의 지식과 신념)

  • Kim, Hee Young;Jang, Eun Kyung;Lee, Jin-Hee;Lee, Eun Jung;Oh, Seyeon;Jo, Keum Sig
    • Journal of Korean Clinical Nursing Research
    • /
    • v.23 no.2
    • /
    • pp.211-221
    • /
    • 2017
  • Purpose: A National survey was conducted to assess neonatal intensive care nurses' practice, barriers, knowledge, and belief regarding Kangaroo Care (KC). Methods: A descriptive survey was conducted. Kangaroo care questionares were sent to nurses in all hospitals in Korea whose were identified as providing neonatal intensive care services(N=263). Descriptive statistics were used to summarized the data. Results: Among 67 neonatal care units, 61.1% adapted KC in their practice. About 60% of nurses in the KC providing hospital actually practiced KC. Major barrier of practicing KC were infant safety concerns, as well as work load of nurses. Respondants who had practiced KC were more knowledgable and were more positive in their belief regarding KC. Conclusion: The findings suggest that in order to overcome barriers of practicing KC, educational programs are recommended designed for nurses. In addition, development of KC practice guideline is necessary to facilicate successful and safe KC.