• 제목/요약/키워드: Safe position

검색결과 314건 처리시간 0.022초

1차 포장이 이침의 침첨 불량에 미치는 영향 (The effect of initial packaging on the deformation of ear acupuncture needle tips)

  • 최광호;권오상;이상훈;조성진;이새봄;연선희;최선미;류연희
    • 한국한의학연구원논문집
    • /
    • 제18권3호
    • /
    • pp.87-93
    • /
    • 2012
  • Objectives : The present study is to verify whether the deformation of ear acupuncture needle tips that are currently on the market is caused during the process of initial packaging. Methods : Ear acupuncture needles distributed from three different companies were collected to measure the size of the groove on the transparent plate which is used in for the intial packaging. Then the tolerance range for off-centered tips, which represent the range of the groove size that is safe from damaging the needle tip, was determined based on the vertical length measured from tip to handle. 200 ear acupuncture needles were dipped in alcohol and scanned to confirm the position of the needles. Stereo-microscope was used to observe the needle tips that were located outside the tolerance range. Results : The increased number of ear acupuncture needle tips placed outside the tolerance range were seen from in the order of C company, A company and B company. The increased deformation of the needle tips caused by initial packaging was observed in the order of A company, C company and B company. Conclusion : Only the ear acupuncture needles from B company showed the strong correlation between needle tip deformation and initial packaging. It has been observed that the deformation of the ear acupuncture needles is mainly due to manufacturing process, not the packaging process.

좁은 치조골에서 사다리꼴형 디자인으로 개발된 단폭경임플란트의 증례 보고 (Case report of a newly designed narrow-diameter implant with trapezoid-shape for deficient alveolar bone)

  • 이사야;고미선;고석영;윤정호
    • 대한치과의사협회지
    • /
    • 제56권5호
    • /
    • pp.263-276
    • /
    • 2018
  • Long-term survival and prognosis of narrow-diameter implants have been reported to be adequate to consider them a safe method for treating a deficient alveolar ridge. The objective of this study was to perform case report of narrow-diameter implants with a trapezoid-shape in anterior teeth alveolar bone. A 50-year-old male patient presented with discomfort due to mobility of all of the maxillary teeth and mandibular incisors. Due to destruction of alveolar bone, four anterior mandibular teeth were extracted. Soft tissue healing was allowed for approximately 3 months after the extraction, and a new design of implant placement was planned for the mandibular incisor area, followed by clinical and radiological evaluation. Implant placement was determined using an R2GATE surgical stent. The stability of the implants was assessed by ISQ measurements at the first and second implant surgery and after prosthetic placement. At 1 and 3 months and 1 year after implantation of the prosthesis, clinical and radiological examinations were performed. Another 50-year-old male patient presented with discomfort due to mobility of the mandibular central incisors. For the same reason as in the first patient, implant placement was carried out in the same way after extraction. ISQ measurements and clinical and radiological examinations were performed as in the previous case. In these two clinical cases, 12 months of follow-up revealed that the implant remained stable without inflammation or additional bone loss, and there was no discomfort to the patient. In conclusion, computer-guided implant surgery was used to place an implant in an optimal position considering the upper prosthesis. A new design of a narrow-diameter implant with a trapezoid-shape into anterior mandibular alveolar bone is a less invasive treatment method and is based on the contour of the deficient alveolar ridge. Through all of these procedures, we were able to reduce the number of traumas during surgery, reduce the operation time and total treatment period, and provide patients with more comfortable treatment.

  • PDF

새송이버섯 재배사의 환경요인 분석 (Analysis of Environment Factors in Pleurotus eryngii Cultivation House)

  • 윤용철;서원명;이현우
    • 생물환경조절학회지
    • /
    • 제12권4호
    • /
    • pp.200-206
    • /
    • 2003
  • 본 연구에서는 새송이버섯을 중심으로 품질향상 및 생산량 증대를 목적으로 적정재배사의 구조설계 및 환경조절 기술을 개발 ${\cdot}$ 보급하기 위하여 서부 경남지역의 새송이버서 재배농가를 중심으로 재배사의 구조 및 환경조절장치를 조사하였다. 또한 환경조절실태를 조사하기 위하여 농가에 위치한 2개 동의 상업용 버섯재배사를 대상으로 환경인자를 계측하였다. 본 연구에서는 이들 연구 중 환경인자 계측결과를 분석하였다. 실험기간동안 외기온은 평년과 큰 차이가 없었으나, 재배사 내부의 온도가 설정온도보다 다소 낮게 유지되고 있기 때문에 진주지역의 동절기 최저 외기온을 고려하면, 난방기 용량이나 배관에 문제가 있는 것으로 판단되었다. 난방 시 상하 재배상간 온도차가 최대 2~3$^{\circ}C$ 정도로 높게 나타나 높이별 온도분포가 일정하지 않을 뿐만 아니라 또 최하단 재배상에서 균상이 지나치게 건조하게 되어 버섯의 발이가 잘 되지 않는 등의 문제도 종종 발생하였다. 그리고 상대습도는 재배 기간 동안 변화가 심하고, 평균상대습도도 일반적으로 알려져 인ㅅ는 것보다 발이기나 생육기에 모두 다소 높거나 낮게 유지되는 등 습도유지가 일정하지 않은 것을 알 수 있었다. 탄산가스 농도도 권장농도보다 높게 유지되는 등이 문제가 있었다. 조도는 권장조도보다 전반적으로 낮게 유지되고 있음을 알 수 있었다. 또한 버섯의 수확량은 평균적으로 병당 약 67~85 g 정도로 나타났고, 총 판매금액은 균상 구입비의 2배 이사인 것으로 조사되었다.

무선통신기반 열차제어시스템에서의 운전시격 계산과 간격제어 성능개선을 위한 열차간격제어 알고리즘 (Headway Calculation and Train Control Algorithm for Performance Improvement in Radio based Train Control System)

  • 오세찬;김경희;이성훈;김자영;전종화
    • 한국산학기술학회논문지
    • /
    • 제16권10호
    • /
    • pp.6949-6958
    • /
    • 2015
  • 무선통신기반 열차제어시스템은 관할영역 내에 운행 중인 열차의 위치정보를 지상시스템에서 실시간으로 수신하고 다시 각각의 열차의 차상시스템에 새로운 이동권한을 제공함으로써 안전한 간격제어를 수행한다. 열차제어시스템의 성능은 최소 운전시격으로 평가되며 그것은 열차제어시스템의 간격제어 성능뿐만 아니라 운영특성 그리고 열차의 특성을 반영하여 계산된다. 본 논문은 무선통신기반 열차제어시스템의 운전시격 계산과 운전시격을 개선하기 위한 새로운 열차간격제어 알고리즘을 제안한다. 제안된 운전시격 계산 방법은 열차제어시스템 간격제어 성능을 반영한 안전마진 추정을 통해 각각 역간 운전시격과 역 운전시격을 정의한다. 또한 제안된 열차간격제어 개선 알고리즘은 간격제어 개선을 위해 거리와 속도를 포함하는 이동권한을 새롭게 정의하며 선행열차에서 필연적으로 발생하는 제동거리를 이용함으로써 열차의 운전시격을 향상시킬 수 있다. 제안된 운전시격 계산방법을 한국형 무선통신기반 열차제어시스템의 간격제어 성능을 대상으로 시뮬레이션을 수행하며 개선된 열차간격제어 알고리즘과 비교분석 한다. 시뮬레이션 결과에 따르면 제안된 운전시격 계산방법은 향후 무선통신기반 열차제어시스템의 성능 지표로 활용이 가능하며 제안된 간격제어 알고리즘은 기존의 무선통신기반 열차제어시스템의 역 운전시격과 역간 운전시격을 개선할 수 있음을 확인한다.

극한지 탐사 로버의 카메라 시스템 설계를 위한 시뮬레이션 기법 개발 (Development of Simulation Method to Design Rover's Camera System for Extreme Region Exploration)

  • 김창재;박재민;최강혁;신휴성;홍성철
    • 한국산학기술학회논문지
    • /
    • 제20권12호
    • /
    • pp.271-279
    • /
    • 2019
  • 극한환경 지역에서 무인 로버는 다수의 센서와 장비를 탑재하고 인간을 대신해 장기간 탐사 임무를 수행하기 위해 개발된다. 하지만 혹독한 기상과 거친 지형조건을 가진 극한환경 지역에서 로버 카메라 영상은 제한된 가시거리와 시야각을 가지므로, 카메라들은 안전한 원격 주행과 효율적 지형정보 구축을 위해 배치되어야 한다. 이에 본 연구에서는 로버 설계 도면을 기반으로 한 카메라 배치 시뮬레이션을 수행함으로써, 향후 로버 카메라 시스템 제작을 위한 시간과 비용을 최소화 하고자 하였다. 제안한 로버의 카메라 시스템은 총 8대의 카메라가 탑재되며, 기능적 요건에 따라 탐사 및 주행 카메라로 분류 된다. 카메라 배치 시뮬레이션에서는 카메라들의 위치와 경사 각도를 변경하여 가상의 지형을 촬영한다. 로버 카메라의 최적 배치는 가상 지형영상의 가시거리 및 중첩도, 지형 데이터의 정확도 등을 비교 및 분석하여 결정하였다. 카메라 배치 시뮬레이션 결과는 실제 로버 제작에 반영될 예정으로, 향후 극한환경지역을 모사한 모의지형을 구축하고 로버 성능을 종합적으로 평가하여 로버 카메라 시스템의 성능을 개선할 예정이다.

안저골절 정복술 후 풍선 달린 카테터와 방사선조영제의 이용 (Reconstruction of the Orbital Floor Fracture using the Antral Balloon Catheter with Radiopaque Dye)

  • 최환준;이한정;양형은;이영만
    • Archives of Plastic Surgery
    • /
    • 제37권1호
    • /
    • pp.99-103
    • /
    • 2010
  • Purpose: Blow-out fractures are reduced through transcutaneous or transconjunctival incisions. But the field of orbital surgery is difficult due to lack of visualization of fracture site, blind dissection of orbital floor, susceptibility of injury of orbital structures. In these situations, the former technique of using an antral balloon catheter has advantages over other methods for reconstruction because of its rapidity, simplicity, and inexpensiveness. Furthermore, the antral balloon catheter allows not only elevation of the orbital bone fragment but also expansion of the maxillary sinus in cases where there is a fracture of its walls. But postoperative follow-up method using computed tomography is expensive. Hence, we report a simple and inexpensive follow-up method using radiopaque dye inflation. Methods: We performed endoscopic transantral approach in 5 cases of blow-out fracture under general anesthesia. To accomplish this technique, a rigid 4 mm, 0 or 30 degree angled endoscopy was inserted into the maxillary sinus. Inflation of the catheter started gradually, with 10 to 15 mL of saline mixed radiopaque dye (saline: dye, 5 : 1) by syringe and while observing the elevation of the fracture site with endoscope until a proper contour was reached. For the maintain of the position of fractured site, 12 French urinary balloon foley catheter were used in fracture site for 7 - 10 days. Results: Postoperative assessment was performed by means of clinical and simple radiographic examination to secure the catheter under the inferior orbital wall and in the maxillary sinus. No specific complications occurred related to this procedure. Results of the surgery and follow-up in all cases were satisfactory. Conclusion: It may be a better alternative to the conventional follow-up method, with less cost and effectiveness of the catheter patency. The advantages of using the urinary balloon foley catheter with the radiopaque dye include the following : it is safe, efficacy, simple, and especially low cost. On drawback of this method is the discomfort to the patient caused by the catheter during the treatment.

Bone-Anchored Hearing Aid Implant에 대한 1.5 T와 3.0 T에서 MRI 안전성의 생체외 평가 (In Vitro Assessment of MRI Safety at 1.5 T and 3.0 T for Bone-Anchored Hearing Aid Implant)

  • 연규진;김현수;이승근;이태수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권1호
    • /
    • pp.19-25
    • /
    • 2017
  • 본 연구는 1.5 T와 3.0 T Magnetic Resonance Imaging에서 Bone-Anchored Hearing Aid (BAHA) implant의 수평인력, 회전력, 그리고 자화감수성 인공물의 크기를 표준측정 방법에 의해 측정하여 MR 안전성을 평가하였다. BAHA implant의 고정장치와 지지대는 0.5%의 철(iron)이 포함 된 티타늄으로 만들어졌으며, 길이는 10 mm (고정장치 4 mm, 지지대 6 mm), 최대 직경은 7.0 mm이다. 수평인력 측정장치와 자화감수성 인공물 측정장치는 각각 American Society for Testing and Materials (ASTM) F2052-06, F2119-07을 참조하여 아크릴을 이용해 제작했으며, 회전력 측정은 원형 플라스틱 용기를 이용한 측정장치를 사용하였다. 자기유도에 의한 BAHA implnat의 수평인력은 주자장이 가장 큰 지점인 96 cm지점에서 최대 변위각을 측정하였고, 회전력은 원형용기 내부의 $45^{\circ}$간격의 실선 위에 놓았을 때 나타난 회전형태를 정성적 평가기준으로 측정하였다. 자화감수성 인공물은 황산구리($CuS0_4$) 용액이 채워진 용기의 중앙에 BAHA implant를 매달아 영상을 획득한 후 Susceptibility Artifact Measurement (SAM) software를 이용해 크기를 측정하였다. 측정결과 수평인력은 1.5 T와 3.0 T에서 변위각과 변위력은 모두 0으로 나타났다. 회전력은 1.5 T에서는 0(no torque), 3.0 T에서는 +1(mild torque)로 나타났다. 자화감수성 인공물은 최소 13.20 mm, 최대 38.91 mm의 크기로 나타났다. 따라서 1.5 T, 3.0 T의 MR 환경에서 BAHA implant는 환자에게 안전하다.

하악각 골절에서 제 3 대구치 발치 후 아테로-콜라겐 스펀지의 유용성 (Usefulness of Atelo-collgen sponge (Teruplug$^{(R)}$) for Treatment of Mandibular Angle Fractures with Third Molar Extraction)

  • 오화영;최환준;권준성;이형교;김용배
    • Archives of Plastic Surgery
    • /
    • 제38권2호
    • /
    • pp.155-160
    • /
    • 2011
  • Purpose: Fibrillar collagens like type I collagen, are the major constituent of the extracellular matrix and structural protein of bone. Also, it can be a scaffold for osteoblast migration. The purpose of this study is to estimate the effects of absorbable atelo-collagen sponge (Teruplug$^{(R)}$, Terumo biomaterials Co., Tokyo, Japan) insertion in tooth extraction sites on periodontal healing of the second molar, healing of the fractured mandibular bone and new bone formation of third molar socket after the extraction of the impacted third molar with mandibular angle fracture. Methods: In our study of six cases of mandibular angle fractures, all of them underwent the extraction of the third molar tooth & absorbable atelo-collagen sponge insertion in tooth extraction site. Three of them had a intraoral infection & oral opening to fracture site, two of the six had dental caries, and only one had reduction problem due to third molar position. Six consecutive patients with noncomminuted fractures of the mandibular angle were treated by open reduction and internal fixation using one noncompression miniplates and screws placed through a transoral incision. Results: All of the patients have showed good postoperative functions and have not experienced complications requiring second surgical intervention. There was well healing of the mandibular bone and the most new bone formation of third molar socket after the extraction of the impacted third molar with mandibular angle fracture. Conclusion: The results of this study suggest that absorbable atelo-collagen sponge is relatively favorable bone void filler with prevention of tissue collapse, food packing, and enhance periodontal healing. Thus, the use of atelo-collagen sponge and one noncompression miniplate seems to be relatively easy, safe, and effective for the treatment of fractures of the mandibular angle and third molar extraction.

Interactive Navigational Structures

  • Czaplewski, Krzysztof;Wisniewski, Zbigniew
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2006년도 International Symposium on GPS/GNSS Vol.1
    • /
    • pp.495-500
    • /
    • 2006
  • Satellite systems for objects positioning appeared indispensable for performing basic tasks of maritime navigation. Navigation, understood as safe and effective conducting a vehicle from one point to another, within a specific physical-geographical environment. [Kopacz, $Urba{\acute{n}}ski$, 1998]. However, the systems have not solved the problem of accessibility to reliable and highly accurate information about a position of an object, especially if surveyed toward on-shore navigational signs or in sea depth. And it's of considerable significance for many navigational tasks, carried out within the frameworks of special works performance and submarine navigation. In addition, positioning precisely the objects other than vessels, while executing hydrographical works, is not always possible with a use of any satellite system. Difficulties with GPS application show up also while positioning such off-lying dangers as wrecks, underwater and aquatic rocks also other naturaland artificial obstacles. It is caused by impossibility of surveyors approaching directly any such object while its positioning. Moreover, determination of vessels positions mutually (mutual geometrical relations) by teams carrying out one common tasks at sea, demands applying the navigational techniques other than the satellite ones. Vessels'staying precisely on specified positions is of special importance in, among the others, the cases as follows: - surveying vessels while carrying out bathymetric works, wire dragging; - special tasks watercraft in course of carrying out scientific research, sea bottom exploration etc. The problems are essential for maritime economy and the Country defence readiness. Resolving them requires applying not only the satellite navigation methods, but also the terrestrial ones. The condition for implementation of the geo-navigation methods is at present the methods development both: in aspects of their techniques and technologies as well as survey data evaluation. Now, the classical geo-navigation comprises procedures, which meet out-of-date accuracy standards. To enable meeting the present-day requirements, the methods should refer to well-recognised and still developed methods of contemporary geodesy. Moreover, in a time of computerization and automation of calculating, it is feasible to create also such software, which could be applied in the integrated navigational systems, allowing carrying out navigation, provided with combinatory systems as well as with the new positioning methods. Whereas, as regards data evaluation, there should be applied the most advanced achievements in that subject; first of all the newest, although theoretically well-recognised estimation methods, including estimation [Hampel et al. 1986; $Wi{\acute{s}}niewski$ 2005; Yang 1997; Yang et al. 1999]. Such approach to the problem consisting in positioning a vehicle in motion and solid objects under observation enables an opportunity of creating dynamic and interactive navigational structures. The main subject of the theoretical suggested in this paper is the Interactive Navigational Structure. In this paper, the Structure will stand for the existing navigational signs systems, any observed solid objects and also vehicles, carrying out navigation (submarines inclusive), which, owing to mutual dependencies, (geometrical and physical) allow to determine coordinates of this new Structure's elements and to correct the already known coordinates of other elements.

  • PDF

자기부상열차 차량과 분기기 동적상호작용 시험 평가 (Dynamic Interaction Evaluation of Maglev Vehicle and the Segmented Switching System)

  • 이종민;한종부;김성수
    • 한국산학기술학회논문지
    • /
    • 제18권2호
    • /
    • pp.576-582
    • /
    • 2017
  • 자기부상열차의 분기기는 차량의 진행방향에 따라 노선을 변경해 주는 장치로서 차량의 분기기 통과시 차량의 주행 안전성을 보장해야만 한다. 일반 바퀴식 열차의 분기기기와는 달리 자기부상열차의 분기기는 대차가 궤도를 감싸고 주행하므로 분기기를 지지하는 구조물은 거더 형태로 구성된다. 이러한 분기기 구조는 거더 자체가 움직여 작은 반경의 곡선을 생성하기 위하여 단지 3~4개의 관절만을 이용하기 때문에 비연속적 선형레일을 만들게 된다. 이로 인하여 비연속적 선형 레일은 거더 사이에 변곡점이 생기고, 이를 통과하는 차량의 진동을 발생시킬 수 있다. 그로인해 해당 지점에서 대차와 레일의 접촉이 발생할 수 있다. 또한 분기기 전체가 강 구조물로 구성되어 있어 진동 측면에서도 일반적인 콘크리트 구조물에 비해 취약한 구조를 가지고 있다. 본 논문에서는 인천공항 시범노선에서 운행 중인 차량의 분기기 통과 시 동적상호작용에 의한 분기기의 진동 및 처짐 등을 측정하고, 차량의 진동 및 부상안정성 등을 측정하여 분기기의 설계 타당성과 안전성을 평가하고 향후 성능 개선에 도움을 주고자 한다. 본 연구의 결과를 통해서 차량의 25km/h 속도에서 부상 및 횡공극의 안정성을 확인하였고, 차량의 승차감이 UIC 513 기준에서 "편안함" 결과를 확인하였다.