• Title/Summary/Keyword: SaO2

Search Result 368, Processing Time 0.027 seconds

The Changes of Arterial Oxygen Saturation During Sleep in Chronic Obstructive Pulmonary Disease Patients (만성 폐쇄성 폐질환 환자에서 수면중 동맥혈 산소 포화도의 변화)

  • Jeong, Ki-Ho;Choi, Hyung-Seok;Hyun, In-Gyu;Choi, Dong-Chull;Yoo, Chul-Gyu;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo;Kim, Keon-Youl;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.38 no.3
    • /
    • pp.255-261
    • /
    • 1991
  • Frequently patients with chronic obstructive pulmonary disease have lowered arterial oxygen saturation in daytime. During sleep, they are apt to experience additional hypoxemia. These episode of nocturnal hypoxemia are usually associated with periods of relative hypoventilation. Noctunal hypoxemia may be associated with cardiac arrhythmia and with acute increase in pulmonary arterial pressure and may be implicated in the development of chronic pulmonary hypertension and cor pulmonale. We selected 14 patients with chronic obstructive pulmonary disease, 9 with emphysema dominant type and 5 with chronic bronchitis dominant type, to examine the frequency and severity of nocturnal hypoxemia and the effect of oxygen in prevention of nocturnal hypoxemia. The results were as follows; 1) On PFT, FVC, $FEV_1$, and $FEV_1$/FVC showed no significant difference between the emphysema dominant type (pink puffers, PP) and the chronic bronchitis dominant type (blue bloaters, BB). But DLCO/VA for the PP group was $45.7{\pm}15.1%$ which was significantly different from BB group, $82.4{\pm}5.6%$. 2) The daytime arterial oxygen saturation ($SaO_2$) and the lowest $SaO_2$, during sleep for the BB group were significantly lower than for the PP group. 3) The hypoxemic episodes during sleep were more frequent in BB group and the duration of hypoxemic episode was longer in BB group. 4) In both group studied, although there was a tendency for a lower L-$SaO_2$ (the lowest $SaO_2$, during sleep), an increase in hypoxemic episodes and duration as the daytime $SaO_2$, fell lower, the only parameter which showed significant correlation was daytime $SaO_2$, and the frequency of hypoxemic episodes in the PP group (r=-0.68, P<0.05). 5) In PP group, with oxygen supplementation, L-$SaO_2$, during sleep showed significant increase, and there was a tendency for the frequency of hypoxemic episodes and duration to fall but it was not significant. 6) In BB group, oxygen supplementation significantly increased the L-$SaO_2$ during sleep and also significantly decreased the frequency and duration of hypoxemic episode. From these results, we can see that oxygen supplementation during sleep can prevent the decrease in $SaO_2$ to some extent and that this effect of oxygen can be seen more prominently in the BB group.

  • PDF

Microwave Thermal Decomposition of CF4 using SiC-Al2O3 (SiC-Al2O3 촉매를 이용한 CF4의 마이크로파 열분해)

  • Choi, Sung-Woo
    • Journal of Environmental Science International
    • /
    • v.22 no.9
    • /
    • pp.1097-1103
    • /
    • 2013
  • Tetrafluoromethane($CF_4$) have been widely used as etching and chemical vapor deposition gases for semiconductor manufacturing processes. $CF_4$ decomposition efficiency using microwave system was carried out as a function of the microwave power, the reaction temperature, and the quantity of $Al_2O_3$ addition. High reaction temperature and addition of $Al_2O_3$ increased the $CF_4$ removal efficiencies and the $CO_2/CF_4$ ratio. When the SA30 (SiC+30wt%$Al_2O_3$) and SA50 (SiC+50wt%$Al_2O_3$) were used, complete $CF_4$ removal was achieved at $1000^{\circ}C$. The $CF_4$ was reacted with $Al_2O_3$ and by-products such as $CO_2/CF_4$ and $AlF_3$ were produced. Significant amount of by-product such as $AlF_3$ was identified by X-ray powder diffraction analysis. It also showed that the ${\gamma}-Al_2O_3$ was transformed to ${\alpha}-Al_2O_3$ after microwave thermal reaction.

Influence of subsequent-annealing on the oxide layer of AZ91 Mg alloy prepared by plasma electrolytic oxidation (PEO 코팅 처리된 AZ91 합금의 산화층에 미치는 후-열처리의 영향)

  • Kim, Y.M.;Ko, Y.G.;Shin, D.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.429-432
    • /
    • 2009
  • The influence of the subsequent-annealing (SA) treatment on plasma electrolytic oxidation (PEO)-treated Mg-based alloy was investigated and the dependence of the dehydration reaction on the SA temperature was also studied. For this purpose, a series of the SA treatments were carried out on the coated samples at two different temperatures, i.e. 423 and 523 K for 10 h. In contrast to the sample without SA treatment, the sample annealed at 523 K exhibited a significant difference in term of surface morphology since the MgO content in the oxide layer increased with increasing SA temperature. With increasing SA temperature, the dehydration of $Mg(OH)_2$ led to the increase in the relative amount of the MgO, which was a hard phase. From the nano-indentation results, the applied loads of the samples were seen to increase as SA temperature increased. However, the corrosion resistance of the sample annealed at 423 K was higher than that of the samples annealed at 523 K.

  • PDF

A Comparative Study on Closed vs. Open Endotracheal Suctioning on the Newborn Infants Treated with Ventilator (인공호흡기 사용 신생아의 폐쇄형과 개방형 기관흡인에 관한 연구)

  • Park, Jeong-Won;Park, Yeong-Ae
    • 아동간호학회:학술대회논문집
    • /
    • 1997.11a
    • /
    • pp.61-74
    • /
    • 1997
  • Endotracheal suctioning is a routine procedure used for clearing secretions from the airway of the intubated infant. This procedure is not without complications. Endotracheal suctioning has been associated with decreases in $PaO_2$, decreases in systemic venous oxygenation, alterations in mean arterial Pressure, disturbances in cardiac rhythm and development of nosocomial pneumonia. So several endotracheal suctioning techniques have been developed to prevent these blown complications. Another method of Endotracheal suctioning eliminates the risk associated with disconnecting the infant from the ventilatior to perform the suctioning procedure. Studies examining closed endotracheal suctioning methods reported that the closed method results in less arterial oxygen saturation, and less systemic venous oxygen desaturation. However those studies have focused on adult patients, and there have been no published studies for newborn infants. The specific purpose of this study is to investigate the two methods and to make a comparison in terms of (1)variations in $SaO_2$, heart rate, and respiration rate appeared before and after the endotracheal suctioning; (2)difference in occurrence of nosocomial infection; (3)difference in recovery time to arrive at pre-suction baseline after suctioning and in nursing time taken for the suctioning. The present study is based on the data obtained from two groups of newborn infants : one group comprises 8 infants with closed suctioning (a total of 304 suctions) among 17 infants treated with ventilator and the other group 9 infants with open method (a total of 629 suctions). The data were analyzed using the SPSS statistical program package. As the distribution test on dependent variables with the Skewnesser Shapiro Wilk test showed an asymmetric distribution, the Wilcoxon Matched-pairs Singled- Ranks test was used for the test of variations in $SaO_2$, heart rate, and respiration rate appeared before and after the endotracheal suctioning. The difference in $SaO_2$ recovery time and nursing time was analyzed with the Mann-Whitney U-Test. The difference in physiologic consequences and occurrence of nosocomial infection between the two groups was analyzed with the Fisher's Exact Test. The results of the study are summarized as follows. For the hypothesis 1 (There would be a difference in $SaO_2$, heart rate, and respiration rate before and after suctioning between the two suctioning methods), the difference in $SaO_2$ turns out to be statistically significant (P=0.015), but heart rate and respiration rate do not procedure a notable difference (P=0.630). The hypothesis 2 (There would be a difference in rates at which a complication arises after suctioning between the two groups) does not prove to be statistically valid (P=0.246). For the hypothesis 3(There would be a difference in $SaO_2$ recovery time and nursing time between the two groups), the average $SaO_2$ recovery time after suctioning turned out to have somewhat significant difference (P=0.064), however the difference in nursing time taken for the suctioning was not statistically significant (P=0.610). The analyses indicate that the closed endotracheal suctioning is more efficient as compared with the open method, in maintaining pre-suction baseline $SaO_2$ and a rapid recovery of newborn infants. Based on these results we suggust to apply the closed method to newborn infants in the ventilation treatment. We also suggest to extend the investigation to include the comparison of suction cost taking into account the case in which a complication arises after endotracheal suctioning between the two groups.

  • PDF

Catalytic Hydrogenation of Triglyceride in a Semi-batch Reactor (Semi-batch 반응기에서의 트리글리세라이드 접촉 수소화 반응)

  • An, Jae-Yong;Lee, Choul-Ho;Jeon, Jong-Ki
    • Clean Technology
    • /
    • v.25 no.2
    • /
    • pp.101-106
    • /
    • 2019
  • The aim of this study is to investigate the feasibility of an Ni-SA catalyst, which was prepared from nickel, kieselguhr, and alumina, for the hydrogenation of triglyceride in a bench-scale reactor. Ni-SA powders were prepared by precipitating nickel precursors on a silica and alumina support. The powder was reduced in a hydrogen flow, mixed with a saturated palm oil, and then cooled to prepare an Ni-SA catalyst tablet. The sizes of NiO crystals of a commercial Pricat catalyst and the Ni-SA catalyst prepared in this study were $35{\AA}$ and $38{\AA}$, respectively. The pore volume and pore size of the Ni-SA catalyst was much larger than the pore volume and pore size of the Pricat catalyst. In addition, the average particle size of the Ni-SA catalyst was much smaller than that of the Pricat catalyst. The triglyceride hydrogenation reaction was carried out in a semi-batch reactor using catalysts impregnated with oil and molded into tablets. It was found that the Ni-SA catalyst was superior to the commercial Pricat catalyst in triglyceride hydrogenation, which could be ascribed to the raw material and the products being less influenced by the diffusion resistance in the pores of the Ni-SA catalyst. The Ni-SA catalyst prepared in this study has the potential to replace the Pricat catalyst as a catalyst for use in the commercial process for hydrogenation of triglyceride.

Effect of Inorganic Particles on Organic Fouling in Pressurized Membrane Filtration (가압식 분리막 여과에서 무기입자의 존재가 유기파울링에 미치는 영향)

  • Jang, Hoseok;Kim, Jeonghwan
    • Membrane Journal
    • /
    • v.30 no.2
    • /
    • pp.131-137
    • /
    • 2020
  • In this study, effect of inorganic particles on organic fouling was investigated by a laboratory-scaled pressurized membrane filtration. In order to cause organic fouling, sodium alginate (SA) was used as a feed solution. Regardless of the presence of inorganic SiO2 particles, the complete pore blocking played an important role in determining the fouling rate during the initial period of membrane filtration. However, the formation of cake layer resulted in the membrane fouling more dominantly as filtration time progressed. In the presence of inorganic particles, both specific cake resistance and compressibility associated with the membrane fouling formed were relatively lower than that without SiO2 particles. Membrane fouling was more severe at constant flux mode of filtration than that observed at constant pressure mode probably due to the concomitant increase of compressibility of fouling layer with transmembrane pressure (TMP). It was found that the presence of SA and SiO2 particles in feed solution provided the synergistic effect on the hydraulic backwashing to reduce membrane fouling as compared to the SA solution alone without the inorganic particles.

A New Snap-back Suppressed SA-LIGBT with Gradual Hole Injection (점진적인 홀의 주입을 통해 스냅백을 억제한 새로운 구조의 SA-LIGBT)

  • Jeon, Jeong-Hun;Lee, Byeong-Hun;Byeon, Dae-Seok;Lee, Won-O;Han, Min-Gu;Choe, Yeol-Ik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.2
    • /
    • pp.113-115
    • /
    • 2000
  • The gradual hole injection LIGBT (GI-LIGBT) which employs the dual gate and the p+ injector, was fabricated for eliminating a negative resistance regime and reducing a forward voltage drop in SA-LIGBT. The elimination of the negative resistance regime is successfully achieved by initiating the hole injection gradually. Furthermore, the experimental results show that the forward voltage drop of GI-LIGBT decreases by lV at the current density of 200 $A/cm^2$, when compared with that of the conventional SA-LIGBT. It is also found that the improvement in the on-state characteristics can be obtained without sacrificing the inherent fast switching characteristics of SA-LIGBT.

  • PDF

CDMA-Based Ubiquitous $SaO_2$ Monitoring System for Oxygen Therapy Patients

  • Lee, Seung-Yup;Kang, Jae-Min;Shin, Il-Hyeung;Lee, Jae-Ho;Lee, Choon-Taek;Kim, Hee-Chan
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.5
    • /
    • pp.274-281
    • /
    • 2006
  • In this paper, we propose a ubiquitous $SaO_2$ monitoring system for patients using oxygen therapy. For these patients, the ability to monitor oxygen saturation ubiquitously is very important fur accurate adjustment of ventilator's flow rate to match the patient's time-varying requirements with the shortest lag time possible. We have developed a portable device to measure $SaO_2$ and transmit it to hospital in real-time or in store-and-forward mode through the integration of $Bluetooth^{TM}$ technology and the code division multiple access (CDMA) cellular network. We also developed software for doctors to receive and manage the patients' $SaO_2$ information. Performance of the developed system was evaluated as acceptable by assessing the accuracy of the measured oxygen saturation value and the stability of communication network. Test results in real clinical setting demonstrate that our system is feasible for immediate use in home oxygen therapy.

Studies on the Chemical Constituents of the New Zealand Deer Velvet Antler Cervus elaphus var. scoticus-(I)

  • Lee, Nam Kyung;Shin, Hyun Jung;Kim, Wan Seok;Lee, Jong Tae;Park, Chae Kyu
    • Natural Product Sciences
    • /
    • v.20 no.3
    • /
    • pp.160-169
    • /
    • 2014
  • 44 compounds and 9 minerals were isolated from and detected in the New Zealand deer velvet antler Cervus elaphus var. scoticus L$\ddot{o}$nnberg. The chemical structures of (1 - 26) were identified on the basis of the spectroscopic methods and comparisons with literature, respectively. The structures were identified as cholesterol (CS, 6), 7-keto-CS (7), $7{\beta}$-hydroxy-CS (8), and $7{\alpha}$-hydroxy-CS (9), and included 12 steroid $3{\beta}$-O-(palmitic/stearic/myristic acid esters; PM/SA/MS) [CS-$3{\beta}$-O-PM (1 - 1), CS-$3{\beta}$-O-SA (1 - 2), CS-$3{\beta}$-O-MR (1 - 3), 7-keto-CS-$3{\beta}$-O-PM (2 - 1), 7-keto-CS-$3{\beta}$-O-SA (2 - 2), 7-keto-CS-$3{\beta}$-O-MR (2 - 3), $7{\beta}$-hydroxy-CS-$3{\beta}$-O-SA (3 -1), $7{\beta}$-hydroxy-CS-$3{\beta}$-O-PM (3 - 2), $7{\beta}$-hydroxy-CS-$3{\beta}$-O-MR (3 - 3), $7{\alpha}$-hydroxy-CS-$3{\beta}$-O-SA (4 - 1), $7{\alpha}$-hydroxy-CS-$3{\beta}$-O-PM (4 - 2), and $7{\alpha}$-hydroxy-CS-$3{\beta}$-O-MR (4 - 3)], dinonyl phthalate (5), 8 nucleic acids analogues [uracil (10), deoxyguanosine (11), deoxyuridine (12), uridine (13), deoxyadenosine (14), adenosine (15), inosine (16), and guanosine (17)], and the 9 free amino acids [L-phenylalanine (18), L-isoleucine (19), L-leucine (20), L-tyrosine (21), L-valine (22), L-proline (23), L-threonine (24), L-alanine (25), and L-hydroxyproline (26)]. Also, there are 8 kinds of amino acids [asparagine, serine, glutamine, glycine, histidine, arginine, methionine, and lysine], 2 sialic acids [N-acetylneuraminic acid (27), ketodeoxynonulosonic acid (28)], and 9 minerals [Na > K > Ca > Mg > Fe > Zn > B > Al > Cu] were detected from the autoaminoacid analyzer and ICP spectrometer, HPAEC-PAD/HPLC-FLD, respectively. 9 kinds of oxycholesterol-$3{\beta}$-O-fatty acid ester (2 - 1, 2 - 2, 2 - 3, 3 - 1, 3 - 2, 3 - 3, 4 - 1, 4 - 2, and 4 - 3) and 3 nucleic acids (12, 14, and 15) were isolated from the velvet antler for the first time. 6 kinds of steroids (7, 8, 9, 2 - 1, 3 - 1, and 4 - 1) were examined for their anti-proliferative effects against L1210, P388D1, K562, MEG-01, KG-1, MOLT-4, A549, HepG2, MCF-7, SK-OV-3, and SW-620 cancer cell lines. They showed anti-proliferative effects with $IC_{50}$ values of 0.06, 2.16, 2.42, > 50.0, 1.66 and $8.31{\mu}M$ against L1210, while the values were 24.05, 9.44, 5.22, 0.25. 9.48 and $49.77{\mu}M$ against P388D1, respectively. The others were inactive.