• 제목/요약/키워드: SV40

검색결과 219건 처리시간 0.033초

Detection Limit of a NaI(Tl) Survey Meter to Measure 131I Accumulation in Thyroid Glands of Children after a Nuclear Power Plant Accident

  • Takahiro Kitajima;Michiaki Kai
    • Journal of Radiation Protection and Research
    • /
    • 제48권3호
    • /
    • pp.131-143
    • /
    • 2023
  • Background: This study examined the detection limit of thyroid screening monitoring conducted at the time of the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident in 2011 using a Monte Carlo simulation. Materials and Methods: We calculated the detection limit of a NaI(Tl) survey meter to measure 131I accumulation in the thyroid gland of children. Mathematical phantoms of 1- and 5-year-old children were developed in the simulation of the Particle and Heavy Ion Transport code System code. Contamination of the body surface with eight radionuclides found after the FDNPP accident was assumed to have been deposited on the neck and shoulder area. Results and Discussion: The detection limit was calculated as a function of ambient dose rate. In the case of 40 Bq/cm2 contamination on the body surface of the neck, the present simulations showed that residual thyroid radioactivity corresponding to thyroid dose of 100 mSv can be detected within 21 days after intake at the ambient dose rate of 0.2 µSv/hr and within 11 days in the case of 2.0 µSv/hr. When a time constant of 10 seconds was used at the dose rate of 0.2 µSv/hr, the estimated survey meter output error was 5%. Evaluation of the effect of individual differences in the location of the thyroid gland confirmed that the measured value would decrease by approximately 6% for a height difference of ±1 cm and increase by approximately 65% for a depth of 1 cm. Conclusion: In the event of a nuclear disaster, simple measurements carried out using a NaI(Tl) scintillation survey meter remain effective for assessing 131I intake. However, it should be noted that the presence of short-half-life radioactive materials on the body surface affects the detection limit.

Characterization of a Positive Regulatory cis-Element and Transacting Factors for the Hepatitis B Viral Pregenomic Promoter

  • Choi, Cheol-Yong;Park, Geon-Tae;Rho, Hyune-Mo
    • BMB Reports
    • /
    • 제29권2호
    • /
    • pp.156-162
    • /
    • 1996
  • Transcription of hepatitis B viral pregenomic promoter is known to be regulated mainly by the combined interaction of enhancers I, II and the intervening regulatory sequences between the two enhancers. A positive regulatory element was identified by serial deletion and measuring the linked chloramphenicol acetyltransferase (CAT) activities, which overlapped with the 5' region of the X open reading frame. When the positive regulatory element was inserted upstream of the SV40 early promoter, it elevated SV40 promoter activity in HepG2 cells. Two cellular proteins of 110 (p110) and 33 (p33) kDa interacted with the positive element and both of them were present in the nucleus, but p110 also existed in the cytoplasm in phosphorylated form. Dephosphorylation of p110 by acid phosphatase enhanced the DNA-binding activity of p110. The p33 could bind to single-strand DNA specifically as well as to double-strand DNA.

  • PDF

10 MV 이상 고에너지 치료 시 발생되는 광중성자의 영향 (The Effect of Photoneutron Dose in High Energy Radiotherapy)

  • 박병석;안종호;권동열;서정민;송기원
    • 대한방사선치료학회지
    • /
    • 제25권1호
    • /
    • pp.9-14
    • /
    • 2013
  • 목 적: 10 MV 이상 고에너지 방사선 치료 시 광핵반응을 통해 광중성자가 발생된다. 광중성자는 방사선하중계수가 X선 보다 커 작은 선량에도 인체에 미치는 영향이 크므로 정확한 선량계산 및 고려가 필요하다. 이에 광자선 에너지 크기와 치료방법에 따른 광중성자의 선량변화를 공간적인 측면에서 비교 분석하였다. 대상 및 방법: 광자선의 에너지 크기에 따른 광중성자의 선량 변화를 측정하고자 동일한 치료부위의 환자를 대상으로 치료 계획을 10 MV와 15 MV conventional plan으로 각각 만들었다. 그리고 치료방법에 따른 차이에 대해 측정하고자 10 MV conventional plan과 10 MV IMRT plan을 각각 만들었다. 검출기의 위치는 광자선원으로부터 isocenter까지의 거리를 100 cm으로 정한 기준점을 $^3He$비례계수기의 중심점에 위치시키고 광중성자 선량을 측정하였다. 또한 중심점을 기준으로 couch의 longitudinal 방향으로 상방, 하방 50 cm 방향으로 각각 $^3He$비례계수기를 위치시켜 위치변화에 따른 선량변화를 측정하여 상용프로그램을 이용하여 분석하였다. 결 과: 에너지 크기에 따른 광중성자의 평균 누적선량은 10 MV, 15 MV conventional RT시 각각 $220.27{\mu}Sv$, $526.61{\mu}Sv$로 15 MV conventional RT가 평균 2.39배의 선량이 증가하였다. 동일한 에너지의 conventional RT와 IMRT의 광중성자의 평균 누적선량은 Conventional RT, IMRT 시 각각 $220.27{\mu}Sv$, $308.27{\mu}Sv$로 IMRT가 1.40배의 선량이 증가하였다. 측정위치에 따른 광중성자의 누적선량은 Conventional RT시 point 2가 3보다 10 MV에서는 약 7.1%, 15 MV에서는 3.0%로 유의하게 높게 측정되었다. 결 론: 고에너지 방사선 치료 시 광중성자에 의한 불필요한 선량을 줄이기 위해 에너지의 선택, 치료 방법의 결정 및 환자의 position을 고려해야 할 것이다. 또한 광중성자의 선량 데이터를 체계화하여 전산화계획 프로그램에 적용되는 방안을 모색하여야 할 것이다. 이는 환자에게 불필요한 선량을 최소화하고 방사선 치료로 인한 2차 암 발생확률과 부작용을 감소시킬 수 있을 것으로 사료된다.

  • PDF

Flavonoid Fraction Purified from Rhus verniciflua Stokes Actively Inhibits Cell Growth Via Induction of Apoptosis in Mouse Tumorigenic Hepatocytes

  • Lee, Jeong-Chae
    • Natural Product Sciences
    • /
    • 제10권2호
    • /
    • pp.74-79
    • /
    • 2004
  • Dietary flavonoids are currently receiving considerable attention in developing novel cancer-preventive approaches because of their potential capacities to actively induce apoptosis of cancer cells. In our previous report, a flavonoid fraction, which consisted mainly of protocatechuic acid, fustin, fisetin, sulfuretin, and butein and named RCMF (RVS chloroform-methanol fraction), was prepared from a crude acetone extract of Rhus verniciflua Stokes (RVS) that is traditionally used as food additive and herbal medicine. In this study, we evaluated the effects of the RCMF on cell proliferation and apoptosis using SV40-transformed tumorigenic hepatocytes, BNL SV A.8. Tritium uptake assay showing the proliferative capacity of the cells was strongly suppressed in the presence of RCMF. This anti-proliferative effect was further confirmed through trypan blue exclusion. RCMF-mediated suppression of cell growth was verified to be apoptotic, based on the increase in DNA fragmentation, low fluorescence intensity in nuclei after propidium iodide staining, and the appearance of DNA laddering. Collectively, this study demonstrated that RCMF can be approached as a potential agent that is capable of significantly inhibiting cell growth of hepatic cancer cells.

방선균에서 분리한 Macrolide 계 항암활성물질 (Antitumoral Macrolide Antibiotics from Streptomyces sp. Ba16)

  • 김항섭;김세은;이성우;방희재;김영호;이정준
    • 한국미생물·생명공학회지
    • /
    • 제22권4호
    • /
    • pp.368-372
    • /
    • 1994
  • Three more unusual macrolides in addition to concnamycin B were isolated from the mycelium of Streptomyces sp. strain Bal6. These four compounds showed a potent cytotoxity to hunian cancer cell lines, SNU-1 (stomach cancer cell line), SNU-354 (liver cancer cell line), MCF- 7 (breast cancer cell line) and KB-3-1 (oral epidermoid carcinoma cell line). Interestingly, these compounds confered slight differential cytotoxity on RHEK-1, a human epidermal keratinocyte cell line immotalized by AD12-SV40 hybrid virus and RHEK-1/pSV$_{2}$ ras which was resulted from H-ras transfomation of RHEK-1. These compounds were determined to be concanamycin A, conca- namycin E and 0-methyl concanamycin B by NMR and other spectral analysis.

  • PDF

Evaluation of physicochemical and biological properties of python fat (Python bivittatus)

  • Pham Thi Quyen;Le Pham Tan Quoc
    • 한국식품저장유통학회지
    • /
    • 제30권5호
    • /
    • pp.758-769
    • /
    • 2023
  • The main aim of this study was to determine python fat's several physicochemical properties, including dimensions, color, structure, acid value (AV), saponification value (SV), density, and recovery efficiency. The optimum yield obtained was approximately 80.40% at 180℃ for 60 min with an AV of 0.3366 and SV of 179.56 mg KOH/g. Fatty acids, comprising oleic acid (72.462%), palmitic acid (26.243%), linolenic acid (0.835%), and myristic acid (0.459%), were identified using gas chromatography-mass spectrometry (GC-MS). The python fat had a very weak antioxidant capacity and almost no antibacterial ability with gram-positive (Staphylococcus aureus - ATCC 25923 and Bacillus cereus - ATCC 10876) and gram-negative (Escherichia coli - ATCC 25922 and Salmonella enterica - ATCC 35664) bacteria (used the paper disc diffusion method for antibiotic susceptibility testing). Moreover, python fat is considered to be very resistant to high temperatures.

형질 전환 기법을 이용한 인체 간암의 마우스 모델 제작 및 특성 규명 (Production and Characterization of a Transgenic Mouse Model of Human Liver Cancer)

  • 이종숙;이정웅;현병화;이철호;정규식;방남수;염영일
    • Reproductive and Developmental Biology
    • /
    • 제31권3호
    • /
    • pp.145-152
    • /
    • 2007
  • 본 연구에서는 SV40 Tag을 마우스 albumin 유전자의 promoter/enhancer 조절 하에 발현하도록 설계된 재조합 유전자를 마우스 1세포기 수정란에 미세 주입하여 형질 전환마우스를 제작하고 이들의 인체 간암 모델로써의 적합성을 조사하였다. 형질 전환이 확인된 총 11개체의 founder 생쥐들 중 4개체가 간암을 일으켰고, 두 개체는 신장암을, 한 개체는 피부 및 뇌에서 종양을 각각 일으켰다. 이들로부터 외래 유전자를 계대 유전하는 3가계를 얻었다(#1-2, #1-6, #1-11). 이들 가계의 자소들에서 8주령(#1-2, #1-6)혹은 10주령(#1-11)시부터 간암이 반복적으로 발생되었으며, #1-11 founder개체에서 폐로 암세포가 전이된 것 외에는 다른 조직에서의 형태학적 변이가 발견되지 않았다. 간암 발생은 조직학적 변화에 따라 3단계로 나눌 수 있었다. 즉, 출생에서 3주령까지는 간세포의 과량증식을 보이나 세포핵의 이상은 관찰되지 않았으며, 4주령부터 7주령(#1-2, #1-6) 혹은 9주령(#1-11)까지는 diffuse liver cell dysplasia를 나타내지만 tumor nodule은 발견되지 않았고, 그 이후에는 liver dysplasia를 배경으로 간암이 발생하였다. 본 연구에서 작출한 간암 모델 마우스는 인체 간암과 일부 유사한 소견을 보였는바 인체 간암 기전 연구를 위한 유용한 동물 모델로 이용할 수 있을 것으로 생각된다.

건강검진 차량 내 흉부 방사선검사 시 공간산란선 분포 연구 (A Study on the Distribution of Scatter Ray in Chest Radiography of a Health Examination Bus)

  • 조지환;진성진;민병인
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권3호
    • /
    • pp.377-383
    • /
    • 2017
  • 건강검진의 증가와 함께 검진 차량을 이용한 건강검진의 수효 또한 증가하는 추세로, 검진 차량에서의 흉부 방사선검사 시 피폭선량에 대해서도 간과할 수 없다. 실제 피사체가 있을 때 피사체의 체질량지수(BMI), 관전류량(mAs)과의 비교를 통해 산란선 발생량을 측정하여 불필요한 피폭을 최소화할 수 있는 방법을 찾고자 한다. 본 연구의 결과 대상자 BMI 전체 평균은 $23.31{\pm}3.12$으로 남자가 여자보다 BMI 값이 높게 나타났다. 전체 평균 mAs값은 $2.92{\pm}1.19$으로 남자가 여자에 비하여 높게 나타났다. 검사실 내부 위치 1의 산란선 전체 평균값은 $771.81{\pm}151.15{\mu}Sv/hr$로 나타났다. 검사실 출입문 외부 위치 2의 산란선 전체 평균값은 $53.86{\pm}25.66{\mu}Sv/hr$로 측정되었다. 이에 BMI나 mAs가 증가할수록 검사실 내부 위치 1과 외부 위치 2에서의 공간산란선량은 증가하는 것으로 나타났다. 건강검진 차량에서의 피폭선량은 거리역자승법칙을 적용하기에 매우 좁은 공간으로 공간산란선의 피폭을 최대한 줄이기 위해 방사선 관계종사자는 영상의 품질을 저해하지 않는 범위 내에서 가능한 낮은 조사조건으로 검사하고, 검사실 출입문 근처에 검사자가 대기하지 않도록 하는 노력이 필요할 것으로 생각된다.

방사성의약품 투여 시 피폭선량 저감에 대한 연구 (The Study of Radiation Reducing Method during Injection Radiopharmaceuticals)

  • 조석원;정석;박준영;오신현;남궁혁;오기백;김재삼;이창호
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.80-85
    • /
    • 2012
  • 전신 골 스캔은 골친화성 방사성의약품으로 뼈의 생리적 변화를 영상화하는 검사방법으로, 140 keV의 감마선을 방출하는 방사성핵종이 표지된 방사성의약품을 주사 후 촬영하는 영상기법이다. 외부피폭으로부터 방사선방호의 3원칙은 시간, 거리, 차폐이다. 방사성의약품은 투여 시 개봉선원이 되기 때문에 방사선방호 원칙에 따라 피폭을 줄이기 위하여 빠른 시간 내에 주사하는 것이 좋다. 하지만 방사성의약품은 환자에게 직접 투여하기 때문에 선원으로부터 거리를 멀리할 수 없는 제한점이 있다. 본 연구는 방사성의약품으로부터 거리에 따른 피폭선량 변화를 확인하고, 차폐체를 사용 후 피폭량의 변화를 관찰하여 방사선 종사자의 피폭 관리에 도움이 되고자 한다. 방사성의약품 투여 시 소요되는 주사시간의 평균을 구하기 위하여 훈련된 주사 담당자가 환자에게 주사하는 시간을 총 50회 측정하였고, 그 평균값(약 2분)을 구하였다. 1 mL주사기에 옥시드로산테크네슘 925 MBq를 0.2 mL 로 맞춘 다음 50 cm, 100 cm, 150 cm, 200 cm에서 방사선 측정기(FH-40, Thermo Scientific, USA)로 선량을 측정하였다. 그리고 방사선차폐체(납 6 mm)를 선원으로부터 25 cm에 설치 한 후 50 cm 거리에서 선량을 측정하였다. 모든 선량측정은 각각 20회에 걸쳐 재현성을 검증하였다. 차폐 전과 차폐 후의 선량의 상관관계는 SPSS (ver. 18)을 사용하여 paired t-test로 검증하였다. 차폐체를 설치하지 않은 선원으로부터 거리에 따른 2분간 받는 피폭량은 50 cm에서 $1.986{\pm}0.052{\mu}Sv$, 100 cm에서 $0.515{\pm}0.022{\mu}Sv$, 150 cm에서 $0.251{\pm}0.012{\mu}Sv$, 200 cm에서 $0.148{\pm}0.006{\mu}Sv$로 나타났다. 차폐를 설치 후 측정 시 피폭량은 $0.035{\pm}0.003{\mu}Sv$로 차폐체 사용 전과 후의 피폭선량은 통계적으로 유의한 차이가 있는 것으로 나타났다($p$<0.001).전신 골스캔은 핵의학 검사에서 많은 비중을 차지하고 있기 때문에 방사성의약품 투여 시 피폭을 줄이기 위해서 외부피폭의 방어원칙을 적절히 병행하여 피폭 저감을 위해 노력해야 한다. 하지만 방사성의약품은 환자에게 직접 투여하기 때문에 선원으로부터 거리를 멀리할 수 없고, 환자의 혈관 확보가 어려운 경우 주사시간이 길어질 수 있다. 본 연구를 통해 거리가 멀어짐에 따라 피폭선량이 감소하는 것을 확인하였고, 선원으로부터25 cm 거리에 차폐체 설치 시 피폭선량이 감소하는 것을 확인할 수 있었다. 본 연구를 통해 방사성의약품 투여 시 차폐체를 사용함으로써 방사선 피폭 저감에 도움이 될 것으로 사료된다.

  • PDF

64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소 (Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols)

  • 김문찬
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권3호
    • /
    • pp.299-306
    • /
    • 2009
  • MDCT의 시간분해능 향상과 등방성 해상능(isotrophic resolution) 영상의 획득, 그리고 지능적인 심전도 동조를 바탕으로 하여 심혈관 질환의 효과적인 진단검사로 인정받고 있는 후향적 심전도 동조화(retrospective ECG gating) 하의 coronary CT angiography는 상대적으로 많은 환자선량을 제공함으로 인해 우수한 진단방법으로서의 장점을 반감시키고 있다. 이에 각 장치 제조사에서는 환자선량을 감소시키는 방법의 연구가 활성화되어 왔으며, 이의 일환으로 지능적인 cardiac dose modulation 기술과 전향적 심전도 동조화(prospective ECG gating)를 사용한 sequential scan이 도입되고 있다. 이에 본 연구에서는 64 채널 MDCT에서 54 kg, 163 cm인 여성 인체모형팬텀을 대상으로 하고 형광유리선량계를 사용하여 후향적 심전도 동조화 하의 coronary CT angiography 프로토콜에서 환자선량의 정량적 평가와 환자선량 감소를 위해 본원에서 선택적으로 적용하고 있는 5가지 검사 프로토콜을 적용하였을 경우의 effective dose와 중요 부위의 organ dose를 측정 비교하여 다음과 같은 결과를 얻었다. 1) Dose modulation없이 120 kVp와 210 mAs의 노출조건으로 retrospectively ECG gated helical scan으로 시행한 conventional coronary CT angiography 프로토콜의 effective dose는 17.8 mSv였으며, 심장의 organ dose는 103.8 mGy였다. 2) 관전압을 120 kVp에서 100 kVp로 낮추었을 경우 effective dose는 11.0 mSv로 conventional coronary CT에 비해 38.2%가 감소하였으며, 심장은 67.3 mGy로 45.2%가 감소하였다. 3) Cardiac dose modulation을 적용한 경우 effective dose는 13.3 mSv로 conventional coronary CT에 비해 25.3%가 감소하였으며, 심장은 80.0 mGy로 22.9%가 감소하였다. 4) 100 kVp의 저관전압과 cardiac dose modulation을 적용한 경우 effective dose는 8.1 mSv로 conventional coronary CT angiography에 비해 54.5%가 감소하였으며, 심장은 49.5 mGy로 52.3%가 감소하였다.

  • PDF