• Title/Summary/Keyword: SV40

Search Result 218, Processing Time 0.023 seconds

A Study on Ways to Optimize the Period of Hospitalization During High-Dose $^{131}I$ Treatment of the Thyroid Cancer (갑상선암의 고용량 $^{131}I$ 치료 시 입원기간의 최적화방안 연구)

  • Baek, Seong-Min;Ko, Seong-Jin;Kim, Chang-Soo;Kim, Jung-Hoon;Kang, Se-Sik
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.269-276
    • /
    • 2010
  • This study attempts to propose ways to optimize and improve the period of hospitalization for the radioiodine treatment by calculating the dose rate of patients treated with high-dose radioiodine by distance and time slot. As a result, 24 hours after the patient was treated with 100 mCi high-dose iodine, the dose rate was attenuated to $1,035{\mu}Sv/hr$ at the navel, to $109{\mu}Sv/hr$ at 50 cm, and to $33{\mu}Sv/hr$ at 100 cm. 24 hours after the patient was treated with 150 mCi high-dose iodine, the dose rate was attenuated to $637{\mu}Sv/hr$ at the navel, to $100{\mu}Sv/hr$ at 50 cm, and to $40{\mu}Sv/hr$ at 100 cm. 24 hours after the patient was treated with 180 mCi high-dose iodine, the dose rate was attenuated to $1,251{\mu}Sv/hr$ at the navel, $140{\mu}Sv/hr$ at 50 cm, and to $56{\mu}Sv/hr$ at 100 cm. In light of the current criterion for discharge recommended by the US Nuclear Regulatory Commission being $70.4{\mu}Sv/hr$, the present study indicates earlier discharge is feasible by applying a new scheme. This suggests that the proposed scheme in this study will help to solve the problem of shortage of treatment beds with the increasing trend of patients with thyroid cancer taken into consideration.

Assessment of Effective Dose for General Radiography of Adults Based on Diagnostic Reference Level(DRL) by Using PCXMC Program (진단참고준위(DRL)를 기준으로 PCXMC 프로그램을 이용한 성인의 일반촬영 부위별 유효선량 평가)

  • Jeong, Hee-Cheol;Lee, SamYol
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.807-812
    • /
    • 2018
  • In this study, we investigated the conditions used in setting the recommendation level of general radiography diagnostic reference and tried to evaluate the effective dose and biological evaluation using PCXMC v2.0 program. As a result based on the effective dose of male in ICRP 60, the highest Pelvis AP was 0.794 mSv. The lowest Chest PA was 0.050 mSv. In the case of ICRP 103, the highest T-Spine AP was 0.906 mSv The lowest Chest PA was 0.052 mSv. For 40 years old male and female adults, effective doses of general radiography were evaluated and even if the medical exposures are not subject to the limit of dose, efforts should be made to reduce the medical exposures of the people by keeping the dose below the recommended amount in order to minimize the probable effect of radiation hazard.

Effect of Transcriptional Terminator Sequences on Recombinant Protein Expression from Drosophila melanogaster S2 Cell (전사 종결 염기 서열이 Drosophila melanogaster Schneider line 2 세포에서 외래 단백질의 발현에 미치는 영향)

  • Hwang, In-Sook;Park, Jong-Hwa;Lee, Youn-Hyung;Yoon, Jae-Seung;Baek, Kwang-Hee;Chung, In-Sik
    • Applied Biological Chemistry
    • /
    • v.44 no.4
    • /
    • pp.211-214
    • /
    • 2001
  • Utilizing the foreign gene expression system of Drosophila melanogaster Schneider line 2(S2) cell, the degree of transient protein and mRNA expression was examined with different terminators. In the case of transient expression, the expression level of green fluorescent protein(GFP) was the highest when the transfection agent was eliminated and then cultivated for 36 to 48 hr. The terminators(SV40 p(A), SV40 small T-antigen and human gastrin 3'UTR) of the expression vector system were each cloned with endostatin; thereafter, the expression levels of the endostatin and its mRNA were compared. When the expression levels of endostatin were compared 36 hr after transfection, the SV40 p(A) terminator showed the highest expression level of endostatin and its mRNA.

  • PDF

Radiation Exposure of Operator in Intracoronary Radiotherapy Using $^{188}Re$ ($^{188}He$을 이용한 혈관내 방사선 치료시 시술자의 방사선 피폭 수준)

  • Chie, Eui-Kyu;Lee, Myung-Mook;Wu, Hong-Gyun
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.4
    • /
    • pp.191-195
    • /
    • 2000
  • This study was undertaken to estimate the exposed dose of the medical personnel during the intracoronary radiotherapy procedure as a part of ongoing SPARE (Seoul National University Hospital Post-Angioplasty Rhenium) trial. Data of thirty-four patients among forty-two irradiated patients participating in this trial due to coronary artery stenosis were retrospectively analyzed. Intracoronary radiotherapy was delivered to the patient immediately after angioplasty ballooning. Prescribed dose was 17 Gy to media of the diseased artery and was delivered with $^{188}Re$ filled balloon catheter. Dosimetry was carried out with GM counter at eight different points. Ten centimeter and forty centimeter from the patient's heart were selected to represent maximum and whole-body exposed dose of the operator, respectively. Median delivered dose was 111.6 mCi with average treatment time of 576 seconds. Average exposed dose rate at 10 cm and 40 cm from the patient's heart were 0.43 mSv/hr and 0.30 mSv/hr, respectively. Average exposed doses per treatment were 0.07 mSv and 0.05 mSv for 10 cm and 40 cm from the patient's heart, respectively. Exposed doses measured are much lower than recommended limit of 50 mSv for radiation workers or 1 mSv for general population in ICRP-60. This study proves that current method of intracoronary radiotherapy incorporated in this trial is very safe regarding radiation protection.

  • PDF

Spatial Dose Distribution from Portable Hand-Held Dental X-Ray Equipment (이동형 치과 X선 발생장치의 공간선량 분포)

  • Han, Gyeong-Soon;Ahn, Sung-Min
    • Journal of dental hygiene science
    • /
    • v.15 no.3
    • /
    • pp.254-258
    • /
    • 2015
  • To compare the stationary dental X-ray generator and the portable dental X-ray generator and to understand spatial radiation dose depended on locations by measuring spatial radiation dose of the portable dental X-ray generator. The researchers used an Ionization chamber to measure spatial radiation dose which was generated while applying X-ray radiation to real bone skull phantom with both portable and stationary dental X-ray generator. There were 4 measurement locations which were immediate anterior, right, left and posterior. Distance of measurement was 50 cm in every location and the recorded result is an average of two applications of X-ray radiation to the maxillary molar area under the condition of 70 kVp, 3 mA, 0.1 sec. Average spatial radiation dose of portable X-ray generator was $37.51{\mu}Sv$, much higher than that of stationary X-ray generator which was $10.77{\mu}Sv$ (p<0.001). The result of the spatial radiation dose of the portable X-ray generator showed a huge difference depending on types of units which varied from $17.77{\mu}Sv$ to $68.90{\mu}Sv$ (p<0.05), also depending on the measurement location, immediate anterior resulted in the highest radiation dose of $54.14{\mu}Sv$ and immediate right was the lowest of $13.60{\mu}Sv$. Immediate left and posterior, however, resulted in similar radiation dose which were $42.12{\mu}Sv$, $40.18{\mu}Sv$ (p<0.01). With this result, we claim that usage of portable dental X-ray generator should be restricted to patients who can't move and exposure to radiation should be minimized by wearing lead-apron.

Development of a Plasmid Vector(pSS4) for the Use in Animal Transgenesis (유전자 변환 동물 생산을 위한 Plasmid Vector(pSS4)의 개발)

  • 전진태;이상호;박성수
    • Korean Journal of Animal Reproduction
    • /
    • v.17 no.3
    • /
    • pp.263-267
    • /
    • 1993
  • Transgenic animals have become an important tool in the basic and applied sectors of genetic and biomedical sciences. In particular transgenes provide clear-cut markers in the spatial and temporal analysis of developing embryos for the understanding of developmental mechanisms. For the long-term use of plasmid vector in a particular purpose it would be necessary to develop one's own vector system which can be properly expressed in eukaryotic system. Plasmids were constructed from ori region of pUC19 and early region of SV40 through various steps. LacZ gene coding for $\beta$-galactosides was fused to early gene of SV40 in translational in-frame. Poly(A) tailing site of SV40 was inserted at the 3' lacZ so that initiation, elongation and terminatin be controlled by SV40 transcription (pSS4). Biological function of the constructed pSS4 was demonstrated via microinjection of the plasmid into fertilized loach eggs and subsequent detection of $\beta$-galactosidase in developing embryos. The result indicate that the newly constructed pSS4 is functional in a eukaryotic system in vivo. Thus pSS4 may be used as an efficient tool for the study of embryogenesis and a basic carrier for various genes for animal transgenesis.

  • PDF

Formation of Brain Tumor and Lymphoma by Deregulation of Apoptosis Related Gene Expression in VP-SV40 T Ag Transgenic Mice

  • Lee, Jeong-Woong;Lee, Eun-Ju;Lee, Hoon-Taek;Chung, Kil-Saeng;Ryoo, Zae-Yoong
    • Proceedings of the KSAR Conference
    • /
    • 2001.03a
    • /
    • pp.47-47
    • /
    • 2001
  • The neuropeptide vasopressin (VP) is a nine- amino acid hormone synthesized as preprohormone in the cell bodies of hypothalamic magnocellular neurons. The tumor in magnocellular neurons of the hypothalamus is associated with disfunctions of the cell bodies, leading to the diabetes insipidus. In order to study with the diabetes insipidus caused by a defect in VP synthesis and its secretion, we have produced the transgenic mice regulated by vasopressin promoter inserted to SV40 T antigen coding sequence (pVPSV.IGR2.1). One transgenic line expressing high levels of SV40 T antigen was propagated. The founder and all transgene positive adult animals have appeared with shorten mortality or apparent phenotypic abnormalities, including immune complex disease, and eventually die between 4 and 8 months of age. The mRNA and protein of SV40T antigen transgene were detected in brain of fetus as well as in brain, spleen, lung and lymph node in moribund at the age of 20 weeks. Histological analysis of transgenic mice showed that tumor developed in brain similar to primitive neuroectodermal tumors (PNET) in man. We also detected lymphomas in spleen and lymph node, and consequent tumor formation in various tissues of the transgenic mice. In pVPSV.IGR2.1, 21% mice showed brain tumor (PNET) at 5 weeks and 100% mice showed brain tumor after 15 weeks. In addition, Expression of apoptosis related genes (Bcl-28 & Bax) was increased over their age in mice with PNET as compared to control mice. Apoptosis related gene expression might be deregulated in mice with brain tumor. However, transgenic mice were not developed with the diabetes insipidus. These mice represent the first disease model to exhibit primitive neuroectodermal tumor in brain, as well as a unique model system for exploring the cellular pathogenesis of lymphomas.

  • PDF

A Study on the Individual Radiation Exposure of Medical Facility Nuclear Workers by Job (의료기관 핵의학 종사자의 직무 별 개인피폭선량에 관한 연구)

  • Kang, Chun-Goo;Oh, Ki-Baek;Park, Hoon-Hee;Oh, Shin-Hyun;Park, Min-Soo;Kim, Jung-Yul;Lee, Jin-Kyu;Na, Soo-Kyung;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.9-16
    • /
    • 2010
  • Purpose: With increasing medical use of radiation and radioactive isotopes, there is a need to better manage the risk of radiation exposure. This study aims to grasp and analyze the individual radiation exposure situations of radiation-related workers in a medical facility by specific job, in order to instill awareness of radiation danger and to assist in safety and radiation exposure management for such workers. Materials and Methods: 1 January 2007 to 31 December 2009 to work in medical institutions are classified as radiation workers Nuclear personal radiation dosimeter regularly, continuously administered survey of 40 workers in three years of occupation to target, Imaging Unit beautifully, age, dose sector, job function-related tasks to identify the average annual dose for a deep dose, respectively, were analyzed. The frequency analysis and ANOVA analysis was performed. Results: Imaging Unit beautifully three years the annual dose PET and PET/CT in the work room 11.06~12.62 mSv dose showed the highest, gamma camera injection room 11.72 mSv with a higher average annual dose of occupation by the clinical technicians 8.92 mSv the highest, radiological 7.50 mSv, a nurse 2.61 mSv, the researchers 0.69 mSv, received 0.48 mSv, 0.35 mSv doctors orderly, and detail work employed the average annual dose of the PET and PET/CT work is 12.09 mSv showed the highest radiation dose, gamma camera injection work the 11.72 mSv, gamma camera imaging work 4.92 mSv, treatment and safety management and 2.98 mSv, a nurse working 2.96 mSv, management of 1.72 mSv, work image analysis 0.92 mSv, reading task 0.54 mSv, with receiving 0.51 mSv, 0.29 mSv research work, respectively. Dose sector average annual dose of the study subjects, 15 people (37.5%) than the 1 mSv dose distribution and 5 people (12.5%) and 1.01~5.0 mSv with the dose distribution was less than, 5.01~10.0 mSv in the 14 people (35.0%), 10.01~20.0 mSv in the 6 people (15.0%) of the distribution were analyzed. The average annual dose according to age in occupations that radiological workers 25~34 years old have the highest average of 8.69 mSv dose showed the average annual dose of tenure of 5~9 years in jobs radiation workers in the 9.5 mSv The average was the highest dose. Conclusion: These results suggest that medical radiation workers working in Nuclear Medicine radiation safety management of the majority of the current were carried out in the effectiveness, depending on job characteristics has been found that many differences. However, this requires efforts to minimize radiation exposure, and systematic training for them and for reasonable radiation exposure management system is needed.

  • PDF

Delivery of Hypoxia Inducible Heme Oxygenase-1 Gene Using Dexamethasone Conjugated Polyethylenimine for Protection of Cardiomyocytes under Hypoxia

  • Kim, Hyun-Jung;Kim, Hyun-Ah;Choi, Joon-Sig;Lee, Min-Hyung
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.4
    • /
    • pp.897-901
    • /
    • 2009
  • Heme oxygenase-1 (HO-1) is an anti-inflammatory and anti-apoptotic protein and has been applied to various gene therapy researches. However, constitutive expression of HO-1 may induce deleterious side effects. In this research, hypoxia inducible HO-1 expression plasmid, pEpo-SV-HO-1, was constructed with the erythropoietin (epo) enhancer and simian virus 40 (SV40) promoter to avoid these unwanted side effects. Dexamethasone conjugated polyethylenimine (PEI-Dexa) was used as a gene carrier. It was previously reported that dexamethasone protected cardiomyocytes from apoptosis under hypoxia. In this research, PEI-Dexa reduced the caspase-3 level in hypoxic H9C2 cardiomyocytes as a derivative of dexamethasone, suggesting that PEI-Dexa is an anti-apoptotic reagent as well as a gene carrier. pEpo-SV-HO-1 was transfected to H9C2 cardiomyocytes using PEI-Dexa and the cells were incubated under normoxia or hypoxia. HO-1 expression was induced in the pEpo-SV-HO-1 transfected cells under hypoxia. In addition, cell viability under hypoxia was higher in the pEpo-SV-HO-1 transfected cells than the pEpo-SV-Luc transfected cells. Also, caspase-3 level was reduced in the pEpo-SV-HO-1 transfected cells under hypoxia. In addition to the anti-apoptotic effect of PEI-Dexa, hypoxia inducible HO-1 expression by pEpo-SVHO- 1 may be helpful to protect cardiomyocytes under hypoxia. Therefore, pEpo-SV-HO-1/PEI-Dexa complex may be useful for ischemic heart disease gene therapy.

An Analysis of the Radiation Exposure of Radiologic Technologists in the Field of Diagnostic Radiology according to Duty Station (방사선 진단영역에서 방사선사의 부서별 의료피폭의 분석)

  • Han, Jae-Jin;Kim, Seung-Kook
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.71-75
    • /
    • 1997
  • This study was Investigation that we will become aware of the scattering dose of duty station and TLD value of the radiation exposure by the radiation technologists based on the university hospital located in Kwang ju. The results are followings ; 1. The air of scattering dose in chest, when the number of objects are large, is 2.0 mR in P-A and 4.6 mR in Lat. at the back of X-ray tube 2. Radiologists, radiation exposure in duty station Is 0.22 mSv to 1.96 mSv in general examination, 0.22 mSv to 1.12 mSv in contrast and special examination, 0.26 mSv to 30.96 mSv in angiography, and 0.22 mSv to 0.40 mSv in C.T 3. The value of workig condition reveals 85.5% in general examination, 6% in contrast and special examination, and 5.8% in C.T. When the annual exposure is over 20 mSv, it must be measured again according to ICRP public 60.

  • PDF