• Title/Summary/Keyword: SV40

Search Result 219, Processing Time 0.027 seconds

Obtainment and Characterization of Brain Tumor Cell Using Vasopressin-SV40 T Ag Transgenic Mouse

  • Kim, Sung-Hyun;Lee, Eun-Ju;Kim, Myoung-Li;Park, Jun-Hong;Cho, Kyoungin;Jung, Boo-Kyung;Kim, Hee-Chul;Hwnag, Sol-Ha;Lee, Hoon-Taek;Ryoo, Zae-Young
    • Proceedings of the Korean Society of Developmental Biology Conference
    • /
    • 2003.10a
    • /
    • pp.105-105
    • /
    • 2003
  • In previous reports, pVPSV.IGR2.1 transgenic mouse were described that brain tumor and lymphoma by reason of Vasopressin-SV40 T antigen. In this study, we produced pVPSV.IGR3.6 transgenic mouse that used pVPSV.IGR3.6 vector. Expression of transgene was vary different in transgenic mouse. We obtained 6 transgenic mouse line, moreover they had died at the age of 2-6 weeks without transmitting the transgene to their offspring, and had tumorigenesis on same location with pVPSV.IGR2.1 transgenic mouse. Only a founder mouse was investigated for expression of fusion gene. Here we extended this transgenic approach to the study of tumor progression. From the mouse, we confirmed brain tumor cell, after then cultured for investigate characterization. In this report, we demonstrate that reduction of survival rate in transgenic mouse fused vasopressin gene length, acquisition of brain tumor cell, composition with astrocyte cells and neuronal cells. Finally, cells had no change with increase of passage.

  • PDF

DEVELOPMENT OF ANIMAL CELL EXPRESSION SYSTEM WHICH CONFERS POSITION-INDEPENDENT AND ENHANCED FOREIGN GENE EXPRESSION

  • Yoon, Yeup;Kim, Jong-Mook;Kim, Jung-seob;Oh, Sun-Mo;Kim, Jong-Il;Yoon, Jae-Seung;Baek, Kwang-Hee
    • Proceedings of the Korean Society for Applied Microbiology Conference
    • /
    • 2000.04a
    • /
    • pp.178-181
    • /
    • 2000
  • In order to develop the novel gene expression system, we introduced new control elements which could influence the foreign gene expression in animal cells. When the foreign genes are introduced into the genome of higher eukaryotic cells, the expressions from these integrated genes are often low and can vary greatly depending on the positions of the integration sites due to the complex nature of the chromatin structures (1). First we screened the various DNA sequence elements which can function as an insulator of gene expression from these position effects and can cooperate with the SV40 enhancer/promoter. Among the several DNA elements from the various sources, we identified the particular DNA element which confers the increased frequency of the positive colonies, assayed by the reporter gene from stable selections indicating significantly reduced position effects. This element also showed the several fold-increased expression level as well as the copy-number dependent expression with host cell specificity. Second we modified the transcription termination element where we introduced the specific terminator in combination with SV40 polyA signal. This modified terminator showed the increased efficiency and the level of the gene expression. By combining these two elements, we made the animal cell expression system and tested successfully for the recombinant protein productions of TGF ${\beta}$-soluble receptor, Antithrombin III, and single chain Pro-Urokinase. [Supported by grants from MOCIE]

  • PDF

HEALTH RISK ASSESSMENT OF HOUSEHOLD EXPOSURE TO INDOOR RADON IN ASSOCIATION WITH THE DWELLING'S AGE

  • Shahrokhi, Amin;Shokraee, Forough;Reza, Ali;Rahimi, Hasn
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.155-161
    • /
    • 2015
  • Radon is a naturally occurring radioactive gas and a major indoor contribution of exposure to ionizing radiation in dwellings. $^{222}Rn$ is a health hazard gas what is responsible for thousand lung cancer deaths every year. In this study, indoor radon concentrations present in thirty representative houses in Mahallat city, Iran, were determined in order to estimate lung cancer risk associated with residential radon exposure. Long-term passive method, using CR-39, was used to measure the radon concentration. The results showed an association between the age of the dwellings and the indoor radon concentration that was found, in that the concentration of radon tended to increase as the age of the dwelling also increased. The indoor radon concentrations were calculated to be within the range of $23{\pm}2$ to $350{\pm}26Bq{\cdot}m^{-3}$, with an average of $158Bq{\cdot}m^{-3}$. The annual effective dose from inhaled radon and its decay products was calculated between $0.8{\pm}0.1$ and $12.3{\pm}0.9mSv{\cdot}y^{-1}$, with an average of $5.5mSv{\cdot}y^{-1}$. By taking into consideration the EPA recommendation and ICRP statement, the average annual risk of lung cancer from inhaled radon was calculated as 0.09%, 0.06%, 0.01%, and 0.03% for current smokers (CS), those who had ever smoked (ES), never smokers (NS) and the general population, respectively.

EQUIVALENT DOSE FROM SECONDARY NEUTRONS AND SCATTER PHOTONS IN ADVANCE RADIATION THERAPY TECHNIQUES WITH 15 MV PHOTON BEAMS

  • Ayuthaya, Isra Israngkul Na;Suriyapee, Sivalee;Pengvanich, Phongpheath
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.147-154
    • /
    • 2015
  • The scatter photons and photoneutrons from high energy photon beams (more than 10 MV) will increase the undesired dose to the patient and the staff working in linear accelerator room. This undesired dose which is found at out-of-field area can increase the probability of secondary malignancy. The purpose of this study is to determine the equivalent dose of scatter photons and neutrons generated by 3 different treatment techniques: 3D-conformal, intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT). The measurement was performed using two types of the optically stimulation luminescence detectors (OSL and OSLN) in the Alderson Rando phantom that was irradiated by 3 different treatment techniques following the actual prostate cancer treatment plans. The scatter photon and neutron equivalent dose were compared among the 3 treatments techniques at the surface in the out-of-field area and the critical organs. Maximum equivalent dose of scatter photons and neutrons was found when using the IMRT technique. The scatter neutrons showed average equivalent doses of 0.26, 0.63 and $0.31mSv{\cdot}Gy^{-1}$ at abdominal surface region which was 20 cm from isocenter for 3D, IMRT and VMAT, respectively. The scattered photons equivalent doses were 6.94, 10.17 and $6.56mSv{\cdot}Gy^{-1}$ for 3D, IMRT and VMAT, respectively. For the 5 organ dose measurements, the scattered neutron and photon equivalent doses in out of field from the IMRT plan were highest. The result revealed that the scatter equivalent doses for neutron and photon were higher for IMRT. So the suitable treatment techniques should be selected to benefit the patient and the treatment room staff.

Yeast two-hybrid assay with fluorescence reporter (형광 리포터를 활용한 효모 단백질 잡종 기법 개발)

  • Park, Seong Kyun;Seo, Su Ryeon;Hwang, Byung Joon
    • Korean Journal of Microbiology
    • /
    • v.55 no.3
    • /
    • pp.199-205
    • /
    • 2019
  • Yeast two-hybrid (Y2H) technique has been used to study protein-protein interactions, but its application particularly to a large-scale analysis of protein interaction networks, is limited by the fact that the technique is labor-intensive, based on scoring colonies on plate. Here, we develop a new reporter for the measurement of the protein-protein interactions by flow cytometry. The yeast harboring interacting proteins can also be enriched by fluorescence-activated cell sorting (FACS) or magnetic-activated cell sorting (MACS). When two interacting proteins are present in the same yeast cell, a reporter protein containing 10 tandem repeats of c-myc epitope becomes localized on the surface of the cell wall, without affecting cell growth. We successful measured the surface display of c-myc epitope upon interacting p53 with SV40 T antigen by flow cytometry. Thus, the newly developed Y2H assay based on the display of c-myc repeat on yeast cell wall could be used to the simultaneous analysis of multiple protein-protein interactions without laborious counting colonies on plate.

External Exposure Due to Natural Radionuclides in Building Materials in Korean Dwellings (건축자재내 포함된 천연방사성핵종에 의한 실내 공간의 방사선량 평가)

  • Cho, Yoon Hae;Kim, Chang Jong;Yun, Ju Yong;Cho, Dae-Hyung;Kim, Kwang Pyo
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.181-190
    • /
    • 2012
  • Naturally occurring radioactive materials (NORM) in building materials are main sources of external radiation exposure to the general public. The objective of this study was to assess external radiation dose in Korean dwellings due to NORM in concrete walls. Reference room model for dose assessment was made by analyzing room structure and housing scale of Korean dwellings. In addition, dose assessments were made for varying room sizes. Absorbed doses to air and effective dose rates were calculated using radiation transport code MCNPX. Assuming a reference room of $3{\times}4{\times}2.8m^3$, absorbed dose rates in air were 0.80, 0.97, 0.08 nGy $h^{-1}$ per Bq $kg^{-1}$ for uranium series, thorium series, and $^{40}K$, respectively. Effective dose rates were 0.57, 0.69, 0.058 nSv $h^{-1}$ per Bq $kg^{-1}$, respectively. Radiation dose resulting from concrete of ceiling and floor increased with room area while radiation dose from concrete of walls decreased with room area. Therefore, total radiation doses were almost the same for the varying room area from 5 to $30m^2$. Effective dose in Korean dwellings was calculated based on measurement data of NORM concentration in concrete and occupancy fraction of Korean population by location. Annual effective dose was 0.59 mSv assuming that indoor occupancy fraction was 0.89 and concentrations of uranium series, thorium series and $^{40}K$ were 26, 39, 596 Bq $kg^{-1}$, respectively. Finally, annual effective dose in Korean dwellings can be calculated by the following equation: Effective dose=indoor occupancy fraction${\times}8760\;h\;y^{-1}{\times}(0.57C_U+0.69C_{Th}+0.058C_K)$.

The Effect of 131I Therapy by Taking in Laxatives (방사성요오드 치료 시 완하제 투여 효과)

  • Kil, Sang-Hyeong;LEE, Hyo-Yeong;Park, Kwang-Yeol;Jo, Kyung-Nam;Baek, Seung-Jo;Hwang, Kyo-Min;Cho, Seong-Mook;Choi, Jae-Hyeok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.3-9
    • /
    • 2014
  • Purpose: Our goals were to evaluate the effect of high dose radioiodine treatment for thyroid cancer by taking in laxatives. Materials and Methods: Twenty patients(M:F=13:7, age $46.3{\pm}8.1\;yrs$) who underwent high dose radioiodine treatment were seperated into Group 1 taking $^{131}I$ 5,500 MBq and Group 2 with the use of laxatives after taking $^{131}I$ 5,500 MBq. The whole body was scanned 16 hours and 40 hours after taking radioactive iodines by using gamma camera, the ROIs were drawn on the gastro-intestinal tract and thigh for calculation of reduction ratio. At particular time during hospitalization, the radioactivity remaining in the body was measured in 1 meter from patient by using survey meter (RadEye-G10, Thermo Fisher Scientific, USA). Schematic presentation of an Origin 8.5.1 software was used for spatial dose rate. Statistical comparison between groups were done using independent samples t-test. P value less than 0.05 was regarded as statistically significant. Results: The reduction ratio in gastro-intestinal 16 hours and 40 hours after taking laxatives is $42.1{\pm}6.3%$ in Group 1 and $72.1{\pm}6.4%$ in Group 2. The spatial dose rate measured when discharging from hospital was $23.8{\pm}6.7{\mu}Sv/h$ in Group 1 and $8.2{\pm}2.4{\mu}Sv/h$ in Group 2. The radioactivity remaining in the body is much decreased at the patient with laxatives(P<0.05). Conclusion: The use in combination with laxatives is helpful for decreasing radioactivity remaining in the body. The radioactive contamination could be decreased at marginal individuals from patients.

  • PDF

Presbyopic Spectacle and Monovision for Reading Performance Before Adaptation (노안안경과 모노비젼 콘택트렌즈 착용 후 적응 전 읽기 능력 평가)

  • Chu, Byoung Sun;Hwang, Jeong Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.263-268
    • /
    • 2010
  • Purpose: Eye movements and fixation ability are an important procedure to obtain external information and essential means of clear vision. The purpose of this study was to determine the reading performance such as reading time and number of fixations when random text was viewed at varying distances. Methods: Twenty two presbyopes were participated. All subjects were screened for their suitability to participate in the study by clinical examination, and none of the participants had previously worn contact lenses and no previous experience of wearing any types of presbyopic vision correction except single vision. The reading time and number of fixations were recorded using eye tracker while each subjects was waring four vision corrections which included single vision for distance (SV), bifocal spectacle lenses (BIF), progressive addition lenses (PAL), and monovision (MV). The reading material was presented at distance and near distance. Results: Reading time and number of fixations for near stimulus were significantly different among vision correction used in this study (p<0.001). In particular, wearing SV required longer reading time and produced longer fixation duration for near text. However, reading distance text was similarity performed across vision corrections tested and there was no statistical difference found for either reading time and number of fixations. Conclusions: Wearing presbyopic vision correction is advantageous for reading task of near stimuli, but not having near correction such as wearing SV could result in longer reading time and higher number of fixation due to lacks of accommodative ability for near task. For the future studies, it would be interesting to examine the performance of reading both at adapted and unadapted stages as examining only unadapted wearers was limitation of this study.

3D SH-wave Velocity Structure of East Asia using Love-Wave Tomography and Implication on Radial Anisotropy (러브파 토모그래피를 이용한 동아시아의 3차원 SH파 속도구조와 이방성 연구)

  • Min, Kyungmin;Chang, Sung-Joon
    • Geophysics and Geophysical Exploration
    • /
    • v.20 no.1
    • /
    • pp.25-32
    • /
    • 2017
  • We present a 3D SH-wave velocity model of the crust and uppermost mantle and seismic radial anisotropy beneath East Asia. The SH-wave velocity structure model was built using Love-wave group-velocity dispersion data from earthquake data recorded at broadband seismic networks of Korea, Japan, and China. Love-wave group-velocity dispersion curves were obtained by using the multiple filtering technique in the period range of 3 to 150 s for 3,369 event-station pairs. The inverted model using these data sets provides a crust and upper mantle SH-wave velocity structure down to 100 km depth. At 10 ~ 40 km depths SH-wave velocity beneath the East Sea is higher than beneath the Japanese island region. We estimated the Moho beneath the East Sea to be between 10 ~ 20 km depth, while Moho beneath the Korean Peninsula at around 35 km based on the depth where high-velocity anomalies are detected. We estimated the lithosphere-asthenosphere boundary beneath the East Sea to be at around 50 km based on the depth where strong low-velocity anomalies are observed. Widespread low-velocity anomalies are found between 50 ~ 100 km depth in the study region. Positive radial anisotropy ($V_{SV}$ > $V _{SH}$) is observed down to 35 km depth, while negative radial anisotropy ($V_{SV}$ > $V _{SH}$) is observed for deeper depth.

Composition of a Medium for Serum-free Culture of an Adipose-derived Stem Cell Line Established with a Simian Virus 40 T Antigen (Simian virus 40의 T항원 도입으로 수립한 지방유래줄기세포주의 효율적인 무혈청 배양법 및 무혈청 배지조성)

  • Kim, Gyu Bin;Joo, Woo Hong;Kim, Dong Wan
    • Journal of Life Science
    • /
    • v.24 no.12
    • /
    • pp.1301-1307
    • /
    • 2014
  • Adipose-derived stem cells (ADSCs) are considered promising tools for tissue regeneration. However, ADSCs have very poor proliferation capacity. Therefore, fetal bovine serum (FBS) is generally added to the culture media of ADSCs. As FBS contains many uncharacterized components that may affect cellular functions, methods for serum-free cultures of ADSCs have been widely investigated. In this study, to develop an efficient method for a serum-free culture of ADSC-T, we used an ADSC line established by introducing the simian virus 40 (SV40) T gene into primary ADSCs. We then investigated the effect of amino acids, vitamins, and other components on the growth of ADSC-T. When the ADSC-T cells were plated with DMEM/F12 serum-free medium, the cells did not proliferate, and the mixture of amino acids, vitamins, and B27 supplement did not increase the growth of the cells. However, when the ADSC-T cells were provided with serum-free DMEM/F12 after they had been cultured with serum-supplemented DMEM for 24 h, the cells proliferated, and the vitamins and B27 supplement increased the cell growth. Stem-Pro serum-free medium also appeared to be useful as a suspension culture for the ADSC-T cells. The ADSC-T cells secreted large amounts of proteins of around 70 kDa. Insulin-like growth factor (IGF) and fibroblast growth factor basic (FGF basic) were secreted by ADSC-T in larger amounts in the serum-free culture than in the serum-supplemented culture.