• Title/Summary/Keyword: SV

Search Result 1,103, Processing Time 0.024 seconds

Voltammetric measurements of iron using an infrared photodiode electrode (적외선 광 다이오드를 사용한 철의 전압전류 정량)

  • Ly, Suw Young;June, Young Sam;Lee, Hyun Ku;Kwak, Kyu Ju;Kim, Kun Woo;Kim, Jong Hyoung;Jeong, Ho Young;Kim, Bong Kyun;Chun, Seok Joo;Chang, Jin Won
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.289-295
    • /
    • 2007
  • A simple electric circuit of an infrared photodiode electrode (IPDE) was utilized to monitor iron using square-wave (SW) anodic stripping voltammetry (SV) and cyclic voltammetry (CV). The optimum analytical conditions were determined and were compared with those of common working electrodes. The comparison showed that CV is more sensitive and convenient to use than the common voltammetry methods. At the optimized conditions, the working ranges of 0.1- to 0.8- and 0.85- to 6.0 mg/L iron was obtained. Relative standard deviation of 15 measurements of iron (0.4 mg/L) was 0.09%. The analytical detection limit was found to be $80{\pm}0.6ug/L$, which was applied to iron in waste water.

The extension of a continuous beliefs system and analyzing herd behavior in stock markets (연속신념시스템의 확장모형을 이용한 주식시장의 군집행동 분석)

  • Park, Beum-Jo
    • Economic Analysis
    • /
    • v.17 no.2
    • /
    • pp.27-55
    • /
    • 2011
  • Although many theoretical studies have tried to explain the volatility in financial markets using models of herd behavior, there have been few empirical studies on dynamic herding due to the technical difficulty of detecting herd behavior with time-series data. Thus, this paper theoretically extends a continuous beliefs system belonging to an agent based economic model by introducing a term representing agents'mutual dependence into each agent's utility function and derives a SV(stochastic volatility)-type econometric model. From this model the time-varying herding parameters are efficiently estimated by a Markov chain Monte Carlo method. Using monthly data of KOSPI and DOW, this paper provides some empirical evidences for stronger herding in the Korean stock market than in the U.S. stock market, and further stronger herding after the global financial crisis than before it. More interesting finding is that time-varying herd behavior has weak autocorrelation and the global financial crisis may increase its volatility significantly.

Development of simultaneous multi-channel data acquisition system for large-area Compton camera (LACC)

  • Junyoung Lee;Youngmo Ku;Sehoon Choi;Goeun Lee ;Taehyeon Eom ;Hyun Su Lee ;Jae Hyeon Kim ;Chan Hyeong Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3822-3830
    • /
    • 2023
  • The large-area Compton camera (LACC), featuring significantly high detection sensitivity, was developed for high-speed localization of gamma-ray sources. Due to the high gamma-ray interaction event rate induced by the high sensitivity, however, the multiplexer-based data acquisition system (DAQ) rapidly saturated, leading to deteriorated energy and imaging resolution at event rates higher than 4.7 × 103 s-1. In the present study, a new simultaneous multi-channel DAQ was developed to improve the energy and imaging resolution of the LACC even under high event rate conditions (104-106 s-1). The performance of the DAQ was evaluated with several point sources under different event rate conditions. The results indicated that the new DAQ offers significantly better performance than the existing DAQ over the entire energy and event rate ranges. Especially, the new DAQ showed high energy resolution under very high event rate conditions, i.e., 6.9% and 8.6% (for 662 keV) at 1.3 × 105 and 1.2 × 106 s-1, respectively. Furthermore, the new DAQ successfully acquired Compton images under those event rates, i.e., imaging resolutions of 13.8° and 19.3° at 8.7 × 104 and 106 s-1, which correspond to 1.8 and 73 μSv/hr or about 18 and 730 times the background level, respectively.

Doses of Pediatric and X-ray Examination Assistants according to Changes in Pediatric X-ray Exposure Conditions (소아 X선 촬영조건 변화에 따른 소아 및 촬영보조자 선량)

  • Beom-Jin Jang;Ha-Yun Nam;Hye-Min Shin;Dong-Min Yun;Seung-Kook Lee;In-Hwa Jang;Sungchul Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.5
    • /
    • pp.409-415
    • /
    • 2023
  • Although pediatric X-ray examinations are continuously increasing, there are not many studies on the radiation exposure to children and X-ray examination assistants according to X-ray Exposure conditions. Accordingly, we measured the radiation exposure dose of pediatric and X-ray examination assistants according to the standard guidelines and clinical average X-ray Exposure conditions when X-ray examination 10-year-old children. The effective dose and organ dose to pediatric were measured using an Dose area production meter and Monte Carlo-based PCXMC program, and the exposure dose of X-ray examination assistants was measured using an ion-chamber. When performing abdominal supine AP projection, the effective dose to children was up to 2.38 times higher under clinical average X-ray Exposure conditions than the standard guidelines. In addition, during abdominal supine AP projection, the radiation exposure dose to the X-ray examination assistants was highest on the hands at 0.0148 ~ 0.0709 mSv, and exposure dose could be reduced by up to 35% when wearing protective gloves. In conclusion, because the X-ray Exposure conditions used in clinical are unnecessarily high, unnecessary medical radiation exposure could be reduced if appropriate X-ray Exposure conditions and the radiation field area were minimized and the assistant wore shielding gloves.

Hemodynamic effects of Chunwangbosim-dan - A 3-dimensional radial pulse tonometry device study (3차원 맥영상 검사로 살펴본 천왕보심단이 심혈관계에 미치는 영향)

  • HeeJung KANG;YoungSang KUN;Tae Hun KU;Gyeung Cheul KIM
    • Journal of Convergence Korean Medicine
    • /
    • v.6 no.1
    • /
    • pp.5-20
    • /
    • 2024
  • Objectives: This study was aimed to evaluate the hemodynamic feasibility using pulse parameters as a way to establish safe dose guidelines for Chunwangbosim-dan, and to provide a foundation for developing evidence-based guidelines for clinical use. Methods: Forty-one volunteers were recruited to participate in a study examining the changes in pulse wave characteristics following the ingestion of Chunwangbosim-dan, over a period of 2 weeks, and pulse wave measurements were taken before and after the administration. Pulse wave parameters were measured in this study using a 3-dimensional radial pulse tonometry device(DMP-Lifeplus). In addition, questionnaire, blood pressure, temperature, and body composition were also measured as secondary measures. Results: Fifteen minutes after administration of Chunwangbosim-dan, the non-adverse event group(non-AE) exhibited a statistically significant increase in several power and pressure-related parameters, including h1, h3, h4, h5, SA, PA and PW, while the adverse event group(AE) showed a trend of decreasing stroke volume and increasing Systemic Vascular Resistance Index(SVRI) and applied pressure. After 2 weeks of administration, non-adverse event group(non-AE) exhibited significant changes in standard deviation of pulse rate and HRV_LH ratio. Notably, there are significant differences between AE group and non-AE group in h4/h1, w/t, applied pressure, SV and pulse rate. Conclusion: These findings suggest that pulse parameters may be a useful way to establish safe dosing guidelines for Chunwangbosim-dan. Further research is needed to confirm these results and to develop evidence-based guidelines for clinical use.

  • PDF

Dynamic CT Myocardial Perfusion Imaging in Patients without Obstructive Coronary Artery Disease: Quantification of Myocardial Blood Flow according to Varied Heart Rate Increments after Stress

  • Lihua Yu;Xiaofeng Tao;Xu Dai;Ting Liu;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • v.22 no.1
    • /
    • pp.97-105
    • /
    • 2021
  • Objective: The present study aimed to investigate the association between myocardial blood flow (MBF) quantified by dynamic CT myocardial perfusion imaging (CT-MPI) and the increments in heart rate (HR) after stress in patients without obstructive coronary artery disease. Materials and Methods: We retrospectively included 204 subjects who underwent both dynamic CT-MPI and coronary CT angiography (CCTA). Patients with more than minimal coronary stenosis (diameter ≥ 25%), history of myocardial infarction/revascularization, cardiomyopathy, and microvascular dysfunction were excluded. Global MBF at stress was measured using hybrid deconvolution and maximum slope model. Furthermore, the HR increments after stress were recorded. Results: The median radiation dose of dynamic CT-MPI plus CCTA was 5.5 (4.5-6.8) mSv. The median global MBF of all subjects was 156.4 (139.8-180.4) mL/100 mL/min. In subjects with HR increment between 10 to 19 beats per minute (bpm), the global MBF was significantly lower than that of subjects with increment between 20 to 29 bpm (153.3 mL/100 mL/min vs. 171.3 mL/100 mL/min, p = 0.027). This difference became insignificant when the HR increment further increased to ≥ 30 bpm. Conclusion: The global MBF value was associated with the extent of increase in HR after stress. Significantly higher global MBF was seen in subjects with HR increment of ≥ 20 bpm.

Radionuclide concentrations in agricultural soil and lifetime cancer risk due to gamma radioactivity in district Swabi, KPK, Pakistan

  • Umair Azeem;Hannan Younis;Niamat ullah;Khurram Mehboob;Muhammad Ajaz;Mushtaq Ali;Abdullah Hidayat;Wazir Muhammad
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.207-215
    • /
    • 2024
  • This study focuses on measuring the levels of naturally occurring radioactivity in the soil of Swabi, Khyber Pakhtunkhwa, Pakistan, as well as the associated health hazard. Thirty (30) soil samples were collected from various locations and analyzed for 226Ra, 232Th, and 40K radioactivity levels using a High Purity Germanium detector (HPGe) gamma-ray spectrometer with a photo-peak efficiency of approximately 52.3%. The average values obtained for these radionuclides are 35.6 ± 5.7 Bqkg-1, 47 ± 12.5 Bqkg-1, and 877 ± 153 Bqkg-1, respectively. The level of 232Th is slightly higher and 40K is 2.2 times higher than the internationally recommended limit of 30 Bqkg-1 and 400 Bqkg-1, respectively. Various parameters were calculated based on the results obtained, including Radium Equivalent (Raeq), External Hazard (Hex), Absorbed Dose Rate (D), Annual Gonadal Equivalent Dose (AGDE), Annual Effective Dose Rate, and Excess Lifetime Cancer Risk (ELCR), which are 170.3 ± 24 Bqkg-1, 0.46 ± 0.06 Bqkg-1, 81.4 ± 2.04 nGy h-1, 582 ± 78.08 µSvy-1, 99.8 ± 13.5 µSv Gy-1, and 0.349 ± 0.04, respectively. These values are below the limits recommended by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) in 2002. This study highlights the potential radiation threats associated with natural radioactivity levels in the soil of Swabi and provides valuable information for public health and safety.

Effects of Fertilization and Clone on Aboveground and Soil Carbon Storages in a Willow (Salix spp.) Bioenergy Plantation (버드나무(Salix spp.) 조림지내(造林地內) 시비(施肥)와 클론이 지상부(地上部) 및 토양중(土壤中) 탄소축적(炭素蓄積)에 미치는 영향(影響))

  • Park, Gwansoo
    • Journal of Korean Society of Forest Science
    • /
    • v.86 no.2
    • /
    • pp.177-185
    • /
    • 1997
  • The influences of fertilizer treatment and clones of five willows and one hybrid poplar on above ground and soil carbon (C) accumulations in a willow bioenergy plantation were studied. The aboveground and soil samples were collected in the winter of 1992 and 1993 from the previously established willow plantation at Tully, New York, U.S.A. in 1987. Half of the plots were fertilized annually with 336kg/ha N, 112kg/ha P, and 224kg/ha K. All trees were harvested annually. The most productive clone, willow clone SV1 with fertilization, accumulated 5.4 and 6.8 t/ha/yr aboveground C contents during the sixth(1992) and seventh(1993) growing seasons, respectively. The average percentage of C in bolewood, bolebark, and branches for the five willow clones and one hybrid poplar clone ranged from 51.1 to 57.5, from 54.0 to 55.4, and from 55.6 to 56.5, respectively, among all treatment combinations. Only tyro of the six clones(SA22 and SA2) responded significantly to the addition of fertilizer by increasing the amount of aboveground C accumulated for the 1992 sampling period(clone-by-fertilizer interaction). No fertilization effect, on aboveground C content, was noted for the 1993 sampling period. No significant fertilization effect on soil C accumulation for all soil sampling depths(0-10, 10-20, and 20-40cm) was found in 1992 and 1993 sampling years. Little clone effect on soil C content was found in 1992 and 1993 sampling years, except at 0-10cm soil depth in 1992. The significant clonal effect on soil C content at 0-10cm soil depth could be because of stone content variation rather than clonal effect. The significant clone-by-fertilizer treatment interaction observed requires that evaluation of response to fertilization by willows be made for each clone individually.

  • PDF

Usefulness of the quantitative analysis by using the functional parameter index from dynamic salivary glands scintigraphy (동적 타액선 신티그라피에서 기능적 매개변수 지표를 활용한 정량 분석의 유용성)

  • Shin, Chae Ho;Kim, Bong Su;Cho, Yong Gyi;Jo, Jin Woo;JIn, Sung Eun;Pyo, Sung Jai
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.81-86
    • /
    • 2015
  • Purpose This study was to evaluate the usefulness through the comparison of patients group and healthy control group by acquiring a variety of functional parameters index from time-activity curves of salivary gland scintigraphy using $^{99m}Tc$. Materials and Methods From December 2014 to February 2015 with the targets of 30 patients in the patient group who presented themselves with xerostomia and underwent the salivary gland scan and 10 people in healthy control group, approximately 30 minutes of dynamic Scan was carried out after the intravenous bolus injection of 370 MBq of $^{99m}TcO_4{^-}$ and per os stimulation with Vitamin C powder 20 minutes after the injection. The method of quantitative analysis was as follows, the time-activity curve was drawn after the parotid gland and submandible gland were prescribed as a region of interest, a variety of functional parameters index was obtained in each position of the curve, and the patients group and the control group were compared. Results As for the methods applied in comparison and measurement, uptake ratio (UR), time at maximum counts (Tmax), time at minimum counts (Tmin), maximum accumulation (MA), accumulation velocity, maximum secretion (MS), maximum stimulation secretion (MSS), and secretion velocity (SV) were used. In the comparison of functional parameters index of patient group and normal group, the healthy normal group showed significant difference compared to the patient group in all indices except for the minimum radioactivity time (Tmin), and also in terms of variation over time the normal group showed significant difference compared to the patient group (p<0.05). Conclusion Consequently, it was considered that the quantitative analysis that used a variety of functional parameters index would be useful for evaluating the function of the salivary glands of the patients with xerostomia as an objective and standardized information.

  • PDF

Flow Resistance and Modeling Rule of Fishing Nets -2. Flow Resistance of Bag Nets- (그물어구의 유수저항과 모형수칙 -2. 자루형 그물의 유수저항-)

  • KIM Dae-An
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.2
    • /
    • pp.194-201
    • /
    • 1995
  • In order to make clear the resistance of bag nets, the resistance R of bag nets with wall area S designed in pyramid shape was measured in a circulating water tank with control of flow velocity v and the coefficient k in $R=kSv^2$ was investigated. The coefficient k showed no change In the nets designed in regular pyramid shape when their mouths were attached alternately to the circular and square frames, because their shape in water became a circular cone in the circular frame and equal to the cone with the exception of the vicinity of frame in the square one. On the other hand, a net designed in right pyramid shape and then attached to a rectangular frame showed an elliptic cone with the exception of the vicinity of frame in water, but produced no significant difference in value of k in comparison with that making a circular cone in water. In the nets making a circular cone in water, k was higher in nets with larger d/l, ratio of diameter d to length I of bars, and decreased as the ratio S/S_m$ of S to the area $S_m$ of net mouth was increased or as the attack angle 9 of net to the water flow was decreased. But the value of ks15m was almost constant in the region of S/S_m=1-4$ or $\theta=15-90^{\circ}$ and in creased linearly in S/S_m>4 or in $\theta<15^{\circ}$ However, these variation of k could be summarized by the equation obtained in the previous paper. That is, the coefficient $k(kg\;\cdot\;sec^2/m^4)$ of bag nets was expressed as $$k=160R_e\;^{-01}(\frac{S_n}{S_m})^{1.2}\;(\frac{S_m}{S})^{1.6}$$ for the condition of $R_e<100$ and $$k=100(\frac{S_n}{S_m})^{1.2}\;(\frac{S_m}{S})^{1.6}$$ for $R_e\geq100$, where $S_n$ is their total area projected to the plane perpendicular to the water flow and $R_e$ the Reynolds' number on which the representative size was taken by the value of $\lambda$ defined as $$\lambda={\frac{\pi d^2}{21\;sin\;2\varphi}$$ where If is the angle between two adjacent bars, d the diameter of bars, and 21 the mesh size. Conclusively, it is clarified that the coefficient k obtained in the previous paper agrees with the experimental results for bag nets.

  • PDF