• Title/Summary/Keyword: SUPER Concrete

Search Result 291, Processing Time 0.025 seconds

Prediction of compressive strength of concrete using neural networks

  • Al-Salloum, Yousef A.;Shah, Abid A.;Abbas, H.;Alsayed, Saleh H.;Almusallam, Tarek H.;Al-Haddad, M.S.
    • Computers and Concrete
    • /
    • v.10 no.2
    • /
    • pp.197-217
    • /
    • 2012
  • This research deals with the prediction of compressive strength of normal and high strength concrete using neural networks. The compressive strength was modeled as a function of eight variables: quantities of cement, fine aggregate, coarse aggregate, micro-silica, water and super-plasticizer, maximum size of coarse aggregate, fineness modulus of fine aggregate. Two networks, one using raw variables and another using grouped dimensionless variables were constructed, trained and tested using available experimental data, covering a large range of concrete compressive strengths. The neural network models were compared with regression models. The neural networks based model gave high prediction accuracy and the results demonstrated that the use of neural networks in assessing compressive strength of concrete is both practical and beneficial. The performance of model using the grouped dimensionless variables is better than the prediction using raw variables.

Experimental analysis and modeling of steel fiber reinforced SCC using central composite design

  • Kandasamy, S.;Akila, P.
    • Computers and Concrete
    • /
    • v.15 no.2
    • /
    • pp.215-229
    • /
    • 2015
  • The emerging technology of self compacting concrete, fiber reinforcement together reduces vibration and substitute conventional reinforcement which help in improving the economic efficiency of the construction. The objective of this work is to find the regression model to determine the response surface of mix proportioning Steel Fiber Reinforced Self Compacting Concrete (SFSCC) using statistical investigation. A total of 30 mixtures were designed and analyzed based on Design of Experiment (DOE). The fresh properties of SCC and mechanical properties of concrete were studied using Response Surface Methodology (RSM). The results were analyzed by limited proportion of fly ash, fiber, volume combination ratio of two steel fibers with aspect ratio of 50/35: 60/30 and super plasticizer (SP) dosage. The center composite designs (CCD) have selected to produce the response in quadratic equation. The model responses included in the primary stage were flowing ability, filling ability, passing ability and segregation index whereas in harden stage of concrete, compressive strength, split tensile strength and flexural strength at 28 days were tested. In this paper, the regression model and the response surface plots have been discussed, and optimal results were found for all the responses.

Concrete Test for Creep and Shrinkage Properties on High Strength Concrete (고강도 콘크리트 크리프 및 건조수축 특성을 위한 재료실험)

  • Moon, Hyung-Jae;Cha, Han-Il;Seok, Won-Kyun;Park, Soon-Jeon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.857-860
    • /
    • 2008
  • This study shows systematic procedures for investigating creep and shrinkage properties of 50, 60, 70 MPa concrete mixes, which were developed by Lotte E&C R&D Ins. for Lotte Super Tower Jamsil. The concrete test was performed both local and foreign laboratory, S-Lab. and CTL Group respectively. The former have done for total five days. The procedures included the followings, specimen fabrication, mold removal, specimen marking, water bath curing, packaging, and shipment. The latter has been doing by CTL within PCA(Portland Cement Association). They are testing on static and dynamic modulus of elasticity, compressive strength, creep & shrinkage, splitting tensile strength. In the case of creep and shrinkage, the test will be doing for 18 months according to each loading age.

  • PDF

A Experimental Study on Autogenous Shrinkage properties of Ultra High-Strength Concrete Using Expansion Agent and Shrinkage-reducing (수축저감제 및 팽창재를 조합 사용한 초고강도 콘크리트의 자기수축 특성에 관한 실험적 연구)

  • Park, Hyun;Park, Heung-Lee;Kim, Hak-Young;Paik, Min-Su;Kim, Woo-Jae;Jung, Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.73-76
    • /
    • 2009
  • In ultra-high-strength concrete, chemical shrinkage is larger than drying shrinkage due to using a large amount of cement and admixtures, and this is a factor deteriorating the quality of structures. Thus, we need a new technology for minimizing the shrinkage strain of ultra-high-strength concrete. So, this study have prepared super-high-strength concrete with specified mixing design strength of over 100MPa and have evaluated a method of reducing chemical shrinkage by using expander and shrinkage-reducing agent. According to the results of this study, with regard to the change in length by chemical shrinkage, an expansion effect was observed until the age of seven days. The expansion effect was higher than previous research that used only expander or shrinkage reducing agent. In addition, ultra-high-strength concrete showed a shrinkage rate that slowed down with time, and the effect of the addition of expander material on compressive strength was insignificant. That is shown that required more database to be accumulated through experimental research for the shrinkage strain of members.

  • PDF

A Basic Study on Autogenous Shrinkage and physical property of the Ultra-High-Strength Concrete (초고강도 콘크리트의 자기수축 및 물리적 특성에 관한 기초적 연구)

  • Park, Hyun;Yoon, Ki-Hyun;Cho, Seung-Ho;Kim, Kwang-Ki;Kim, Woo-Jae;Jung, Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.57-60
    • /
    • 2009
  • In ultra-high-strength concrete, autogenous shrinkage is larger than dry shrinkage due to the consume of a large amount of cement and cementitous material, and this is a factor deteriorating the quality of structures. Thus, we need a new technology for minimizing the shrinkage strain for ultra-high-strength concrete. So, this paper have prepared super-high-strength concrete with specified mixing design strength of over 150MPa and have evaluated a method of reducing autogenous shrinkage by utilizing expander and shrinkage-reducing agent. According to the results of this study, with regard to the change in length by autogenous shrinkage, an expansion effect was observed until the age of seven days. The expansion effect was higher when the contents of the expander material were higher. In addition, ultra-high-strength concrete showed a shrinkage rate that slowed down with time, and the effect of the addition of expander material on compressive strength was insignificant. That is shown that required more database to be accumulated through experimental research for the shrinkage strain of members.

  • PDF

DEVELOPMENT OF CONCRETE FILLED TUBE AS A PILLAR PILE FOR TOP DOWN METHOD

  • Jee-Yun Song;Hong-Chul Rhim;Seung-Weon Kim
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.808-813
    • /
    • 2009
  • Top-down method is widely used for urban area construction for its advantages in reducing environmental problems such as dust and noise, and saving construction cost depending on given conditions of a construction site. Because the excavation and construction of super- and sub-structures of the building have to be proceeded simultaneously, a column has to be embedded prior to excavation. This column is called a pillar column or pre-founded column. Usually a wide flange section is used for these columns. To place the columns, usually the diameter of casing holes needs to be larger than the section of the wide flange itself in order to accommodate a couple of tremie pipes for pouring concrete. In this paper, a newly developed method of using circular pipe as an alternative to the existing wide flange section is discussed. The crucial part of the new method is to develop a connection between the circular column and concrete flat slabs. For shear force transfer from concrete slab to the concrete filled tube (CFT) column, shear jackets with studs and shear bands are proposed. The studs are welded on the jackets at shop and placed around the circular column on site. The shear bands are welded on the outer side of the CFT at shop and inserted into ground with the CFT. Test results and application of the method to a construction site are also provided in this paper.

  • PDF

Field monitoring of wind effects on a super-tall building during typhoons

  • Zhi, Lunhai;Li, Q.S.;Wu, J.R.;Li, Z.N.
    • Wind and Structures
    • /
    • v.14 no.3
    • /
    • pp.253-283
    • /
    • 2011
  • This paper presents the field measurement results of wind effects on a super-tall building (CITIC Plaza, 391 m high) located in Guangzhou. The field data such as wind speed, wind direction and acceleration responses were simultaneously and continuously recorded from the tall building by a wind and vibration monitoring system during two typhoons. The typhoon-generated wind characteristics including turbulence intensity, gust factor, peak factor, turbulence integral length scale and power spectral density of fluctuating wind speed were presented and discussed. The dynamic characteristics of the tall building were determined based on the field measurements and compared with those calculated from a 3D finite element model of the building. The measured natural frequencies of the two fundamental sway modes of the building were found to be larger than those calculated. The damping ratios of the building were evaluated by the random decrement technique, which demonstrated amplitude-dependent characteristics. The field measured acceleration responses were compared with wind tunnel test results, which were found to be consistent with the model test data. Finally, the serviceability performance of the super-tall building was assessed based on the field measurement results.

Optimum Mix Design on the Mortar of the Super Flowing Concrete (초유동 콘크리트용 모르터의 최적배합설계)

  • 박칠림;안재현;권영호;이상수
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.3
    • /
    • pp.135-142
    • /
    • 1998
  • 본 연구는 초유동 콘크리트용 모르타르의 물/결합재비 및 고성능 감수제 첨가율에 따른 상대플로우 면적비와 상대깔대기 속도비의 상관관계를 실험으로 검토한 것이다. 구속수비 실험결과, C급 플라이애쉬>F급 플라이애쉬 > 석회석분순으로 나타났기 때문에 F급 플라이애쉬 및 석회석분은 유동성 개선에 효과적인 것으로 나타났다. 또한 모르타르 실험결과, 상대플로우 면적비와 상대깔대기 속도비는 고성능 감수제 첨가율이 일정할 경우 물/결합재비의 변화에 따라 원점을 지나는 직선관계로 나타났지만, 물/결합재비가 일정할 경우에는 고성능 감수제 첨가율의 변화에 따라 원점을 지나는 곡선관계로 나타났다. 따라서, 수식화 모델은 Rm= A. m0.4가 합리적이며, 최적값인 ( m .Rm)=(5.1)을 만족하는 배합조건은 플라이애쉬의 경우 치환율 30%, 물/결합재비 83%이며, 석회분의 경우 치환율30%, 물/결합재비 77%로 판명되었다.

A Study on the Performance Restoration of Deteriorated Concrete by Long Distance Delivery (장시간 운반에 따라 저하된 콘크리트의 품질회복에 관한 연구)

  • Pei Chang-Chun;Jin Hu-Lin;Hwang Yin-Seong;Lee Hyung Won;Yang Seong-Hwan;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • v.y2004m10
    • /
    • pp.7-10
    • /
    • 2004
  • This paper investigated the possibility of quality restoration of deteriorated concrete caused by long distance delivery using chemical admixtures such as superplasticizer. AE agent and retarding agent. According to test results, long distance delivery lead to reducing fluidity and air content markedly, while setting time accelerated. Quality restoration agent(QRA) was made by combining super- plasticizer. AE agent and retarding agent with the proportion of 1:0.0025:0.1. It was confirmed that deteriorated concrete achieved quality restoration with the level of target slump, air content and setting time without strength loss when using QRA with proper amount.

  • PDF

Features of Temperature Distribution of Exposed Reinforcement Bars Depending on Changes of Covering Methods of Bubble Sheets (버블시트 피복방법 변화에 따른 동절기 노출철근의 온도분포 특성)

  • Lee, Jea-Hyeon;Lee, Sang-Un;Lee, Joung-Gyo;Yang, Seong-Hwan;Kyung, Yeong-Hyeok;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.11-12
    • /
    • 2016
  • The contemporary buildings are becoming super-taller gradually as the industry evolves. Accordingly, winter concrete also became an important element for the year-round construction since shortening of a construction duration became important. Accordingly, this research team once developed a double bubble sheet as concrete cover curing compound during winter. But since there is no proper countermeasure for the exposed reinforcement bars, it is worried that the concrete can be damaged by exposed frozen reinforcement bars at a low temperature during the initial period. Therefore, in this study, it is intended to review the temperature history of the reinforcement bars depending on changes of the covering methods of the exposed reinforcement bars by using bubble sheets.

  • PDF