• Title/Summary/Keyword: STORAGE

Search Result 22,983, Processing Time 0.052 seconds

Population Dynamics of Effective Microorganisms in Microbial Pesticides and Environmental-friendly Organic Materials According to Storing Period and Temperature (저장기간 및 저장온도에 따른 미생물농약 및 친환경 유기농자재 유효미생물의 밀도변동)

  • Kim, Yong-Ki;Hong, Sung-Jun;Jee, Hyung-Jin;Shim, Chang-Kee;Park, Jong-Ho;Han, Eun-Jung;An, Nan-Hee;Lee, Seong-Don;Yoo, Jae-Hong
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.1
    • /
    • pp.55-60
    • /
    • 2011
  • To work out quality control methods of environmental-friendly organic materials (EFOMs), the reason and basis for EFOM-selection and farmer's favorite formulation type of EFOMs, etc were investigated on farmers who had been practicing environmental-friendly agriculture. EFOMs used were soil amendments, control agents of plant diseases and insect pests, plant growth promotion formulations, in turns. In EFOMs application time, 22.7% of farmers sprayed EFOMs without delay after they were bought, in other hand, 77.3% of farmers used EFOMs which had been bought and stored for some period. Microbial density on seventeen environmental-friendly microbial formulates (EFMFs) including microbial pesticides, a microbial fertilizer, and environmental-friendly organic materials was investigated at different storing temperature and shelf life. When the microbial density of EFMFs was investigated without delay after they were bought, all used microbial pesticides and a microbial fertilizer was confirmed to be optimal for the certified density but two of environmental-friendly organic materials was confirmed not to be optimal. When microbial density of 17 EFMFs were investigated after storing them for six months at $4^{\circ}C$, only one of 9 microbial pesticides was confirmed not to be optimal, the other hand four of seven environmental-friendly organic materials not to be optimal, which each of their microbial density was less than the certified density. Population dynamics of microbial agents was much more influenced in fluctuated temperature (room temperature) than in static temperature condition ($5^{\circ}C$ and $25^{\circ}C$). Shelf life of microbial agents according to microbial formulation type were high in granule type, liquid wettable type and liquid type in turns.

Processing and Quality Control of Flux Data at Gwangneung Forest (광릉 산림의 플럭스 자료 처리와 품질 관리)

  • Lim, Hee-Jeong;Lee, Young-Hee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.10 no.3
    • /
    • pp.82-93
    • /
    • 2008
  • In order to ensure a standardized data analysis of the eddy covariance measurements, Hong and Kim's quality control program has been updated and used to process eddy covariance data measured at two levels on the main flux tower at Gwangneung site from January to May in 2005. The updated program was allowed to remove outliers automatically for $CO_2$ and latent heat fluxes. The flag system consists of four quality groups(G, D, B and M). During the study period, the missing data were about 25% of the total records. About 60% of the good quality data were obtained after the quality control. The number of record in G group was larger at 40m than at 20m. It is due that the level of 20m was within the roughness sublayer where the presence of the canopy influences directly on the character of the turbulence. About 60% of the bad data were due to low wind speed. Energy balance closure at this site was about 40% during the study period. Large imbalance is attributed partly to the combined effects of the neglected heat storage terms, inaccuracy of ground heat flux and advection due to local wind system near the surface. The analysis of wind direction indicates that the frequent occurrence of positive momentum flux was closely associated with mountain valley wind system at this site. The negative $CO_2$ flux at night was examined in terms of averaging time. The results show that when averaging time is larger than 10min, the magnitude of calculated $CO_2$ fluxes increases rapidly, suggesting that the 30min $CO_2$ flux is influenced severely by the mesoscale motion or nonstationarity. A proper choice of averaging time needs to be considered to get accurate turbulent fluxes during nighttime.

High-Speed Implementation and Efficient Memory Usage of Min-Entropy Estimation Algorithms in NIST SP 800-90B (NIST SP 800-90B의 최소 엔트로피 추정 알고리즘에 대한 고속 구현 및 효율적인 메모리 사용 기법)

  • Kim, Wontae;Yeom, Yongjin;Kang, Ju-Sung
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.28 no.1
    • /
    • pp.25-39
    • /
    • 2018
  • NIST(National Institute of Standards and Technology) has recently published SP 800-90B second draft which is the document for evaluating security of entropy source, a key element of a cryptographic random number generator(RNG), and provided a tool implemented on Python code. In SP 800-90B, the security evaluation of the entropy sources is a process of estimating min-entropy by several estimators. The process of estimating min-entropy is divided into IID track and non-IID track. In IID track, the entropy sources are estimated only from MCV estimator. In non-IID Track, the entropy sources are estimated from 10 estimators including MCV estimator. The running time of the NIST's tool in non-IID track is approximately 20 minutes and the memory usage is over 5.5 GB. For evaluation agencies that have to perform repeatedly evaluations on various samples, and developers or researchers who have to perform experiments in various environments, it may be inconvenient to estimate entropy using the tool and depending on the environment, it may be impossible to execute. In this paper, we propose high-speed implementations and an efficient memory usage technique for min-entropy estimation algorithm of SP 800-90B. Our major achievements are the three improved speed and efficient memory usage reduction methods which are the method applying advantages of C++ code for improving speed of MultiMCW estimator, the method effectively reducing the memory and improving speed of MultiMMC by rebuilding the data storage structure, and the method improving the speed of LZ78Y by rebuilding the data structure. The tool applied our proposed methods is 14 times faster and saves 13 times more memory usage than NIST's tool.

A Sustainable Operation Plan for School Gardens - Based on a Survey of Elementary School Gardens in Seoul (학교 텃밭의 지속적인 운영방안에 관한 연구 - 서울특별시 초등학교의 학교 텃밭 실태조사를 바탕으로 -)

  • Choi, I-Jin;Lee, Jae Jung;Cho, Sang Tae;Jang, Yoon Ah;Heo, Joo Nyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.4
    • /
    • pp.36-48
    • /
    • 2018
  • This study surveyed 599 elementary schools in Seoul to provide measures for the quantitative expansion and sustainable operation of environmentally-friendly school garden. Of all schools, 161 schools had formed and were operating school gardens. The total area of school gardens was $166,901m^2$ and the mean area was $131.2m^2$ in elementary, junior high and high schools in Seoul. Meanwhile, the total area of school gardens was $65,493m^2$ and the mean area was $363m^2$ in 161 schools that participated in the survey, indicating $1.15m^2$ per student. Of these schools, 11.8% were operating gardens themselves, while 50.3% were operating gardens that had been newly renovated or environmentally improved by institutional support projects after initially managing gardens themselves. According to the locations of school gardens, mixed-type gardening (a combination of school gardening and container vegetable gardening) accounted for 34.8%, followed by school gardening at 32.9%, container vegetable gardening at 29.2%, and suburb community gardening at 3.1%. Those in charge of garden operations were teachers at 51.6%, comprising the largest percentage. Facilities built when forming the garden included storage facilities for small-scale greenhouses and farming equipment at 26.1%, accounting for the largest percentage. No additional facilities constructed accounted for 21.7%. The greatest difficulty in operating gardens was garden management at 34.2%. The most needed elements for the sustainable operation of gardens were improvement in physical environment and the need for hiring a paid garden, each accounting for 32%. The most important purpose for school gardening was creating educational environments (81.6%). The major source for gaining information on garden management was consultation from acquaintances (67.8%). Schools that utilize plant waste from gardens as natural fertilizers accounted for 45.8% of all schools. Responses to the impact of operating school gardens for educational purpose were positive in all schools as 'very effective' in 63.2% and 'effective' in 36.8%. This study was meaningful in that it intended to identify the current status of the operation of school gardens in elementary schools in Seoul, support the formation of school gardens appropriate for each school with sustainable operation measures, implement a high-quality education program, develop teaching materials, expand job training opportunities for teachers in charge, devise measures to support specialized instructors, and propose the need for a garden management organization.

Design of MAHA Supercomputing System for Human Genome Analysis (대용량 유전체 분석을 위한 고성능 컴퓨팅 시스템 MAHA)

  • Kim, Young Woo;Kim, Hong-Yeon;Bae, Seungjo;Kim, Hag-Young;Woo, Young-Choon;Park, Soo-Jun;Choi, Wan
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.2 no.2
    • /
    • pp.81-90
    • /
    • 2013
  • During the past decade, many changes and attempts have been tried and are continued developing new technologies in the computing area. The brick wall in computing area, especially power wall, changes computing paradigm from computing hardwares including processor and system architecture to programming environment and application usage. The high performance computing (HPC) area, especially, has been experienced catastrophic changes, and it is now considered as a key to the national competitiveness. In the late 2000's, many leading countries rushed to develop Exascale supercomputing systems, and as a results tens of PetaFLOPS system are prevalent now. In Korea, ICT is well developed and Korea is considered as a one of leading countries in the world, but not for supercomputing area. In this paper, we describe architecture design of MAHA supercomputing system which is aimed to develop 300 TeraFLOPS system for bio-informatics applications like human genome analysis and protein-protein docking. MAHA supercomputing system is consists of four major parts - computing hardware, file system, system software and bio-applications. MAHA supercomputing system is designed to utilize heterogeneous computing accelerators (co-processors like GPGPUs and MICs) to get more performance/$, performance/area, and performance/power. To provide high speed data movement and large capacity, MAHA file system is designed to have asymmetric cluster architecture, and consists of metadata server, data server, and client file system on top of SSD and MAID storage servers. MAHA system softwares are designed to provide user-friendliness and easy-to-use based on integrated system management component - like Bio Workflow management, Integrated Cluster management and Heterogeneous Resource management. MAHA supercomputing system was first installed in Dec., 2011. The theoretical performance of MAHA system was 50 TeraFLOPS and measured performance of 30.3 TeraFLOPS with 32 computing nodes. MAHA system will be upgraded to have 100 TeraFLOPS performance at Jan., 2013.

Effects of Dietary Taurine on the Lipid Metabolism in Laying Hens (사료내 타우린 첨가가 산란계의 지방대사에 미치는 영향)

  • 박강희
    • Korean Journal of Poultry Science
    • /
    • v.29 no.2
    • /
    • pp.95-100
    • /
    • 2002
  • Two experiments were conducted to investigate the effect of taurine supplementation on lipid metabolism in laying hens. In experiment 1, 19-wk-old laying hens were given one of four taurine supplemented diets (0 (control), 0.4, 0.8, and 1.2% taurine) fur 10 weeks. Abdominal fat weight was lower in the 1.2% diet by 29.2% compared to the control. Serum concentrations of triacylglycerol and HDL-cholesterol were not different among the treatments. However, seam concentration of total cholesterol was higher by 22.4% in the 1.2% diet compared to the control. Concentration of triacylglycerol or total cholesterol in the liver were decreased by 26.1% or 26.4% and 28.2% or 26.4%, respectively in the 0.8% and 1.2% diets compared to the control. The concentration of HDL-cholesterol in liver was also lower by 33.9% in the 1.2% diet compared to the control. In experiment 2, 81-wk-old laying hens were allocated to one of three taurine supplemented diets (0 (control), 1 and 2% taurine) fur 6 weeks. Abdominal fat weight was lower by 25% in 1% taurine supplementation compared to the control. Serum concentrations of triacylglycerol, total cholesterol and HDL-cholesterol of hens fed with 1% diet were not different from those of control group. However, sew concentrations of triacylglycerol and total cholesterol were lower by 44.0% and 19.8%, respectively in the 2% diet compared to the control. Furthermore, serum concentration of HDL -cholesterol in the 2% diet was higher by 75% compared to the control. Concentrations of triacylglycerol and total cholesterol in the liver in the 2% diet were decreased in the 1% diet by 36.8 and 23%, respectively, but increased by 78.4% and 70%, respectively, compared to the control. The concentration of HDL-cholesterol in the liver was not different between the 1% diet and the control, but higher by 62.8% in the 2% diet compared to the control. These results indicated that taurine supplementation decreased the fat storage in abdominal cavity, which was accompanied by the changes in triacylglycerol and cholesterol metabolisms of laying hens.

A Study of Industrial Patients from Selected General in the Kyung Pook and Taegu City areas (일부지역 산업재해환자 실태 조사 연구 -대구${\cdot}$경북지역 일부 종합병원 중심으로-)

  • Huh, Choon-Bok
    • The Journal of Korean Physical Therapy
    • /
    • v.3 no.1
    • /
    • pp.151-174
    • /
    • 1991
  • The purpose of this study is to research the actual conditions of industrial accident patients and to produce worker satisfaction and a rational and effective counter measure plan. Direct interviews with 179 cases (in and out patients) were carried out during a three month period from April to July 1990, at six hospitals : two general hospitals Sun Lin and Sung Mo in Po Hang, and four general hospitals in Taegu : Kyung pooh University Hospital, Dong San Medical Center, Young Nam Medical Center and Catholic Hospital. The results of this study are summarized as fellows : 1. Among the 179 cases, $51.6\%$ were male and $48.4\%$ were female. The two largest age groups were 30-39, $31.8\%$ and 20-29, $27.4\%$. Among the 179 cases, $51.6\%$ were married, the largest family number was 2 to 3, $41.1\%$ and 4 to 5, $25.6\%$. Educationally, graduation from high school was the largest group, $46.4\%$ among ,the patients, followed by middle school and primary school. The largest group income level was from 40-69 만원, $45.2\%$. The largest group of patients who worked over 50 hrs. a week was $52.0\%$. The largest group of patients who worked less than 1 year was $44.7\%$, of the patients in work places of less than 100 people, $60.3\%$ were injured and in work places of 100-299 people, $20.1\%$ were injured. In manufacturing, the largest group injured was $55.3\%$, the next group was transport, storage, communication. The largest group of production workers injured was $40.2\%$. 2. The cause of injury in the largest group was facility problems, $33.5\%$. The next group was unsafe habits, $30.2\%$ ; a lack of safety knowledge, $17.9\%$ ; and insufficient supervision, $12.3\%$. The 30-39 year age group head the highest number of injuries, $40.4\%$ ; work places with more than 10 years of work, $44.4\%$ ; work places with more than 1000 people, $56.3\%$ and mining accidents, $80.0\%$. Among. these groups the highest cause of injury was due to facility problems. 3. The accident pattern showed machinery injuries $28.5\%$ as the largest group, followed by falls & falling objects $17.3\%$, fire & electric $15.1\%$, strucke by an object $14.5\%$, followed by overaction and vehicular accidents. The accident pattern showed $46.4\%$ among workers over the 50 year age group, workers in the 5-10 year group, $50.0\%$ ; places employing more than 1000 workers, $35.3\%$ ; construction $73.7\%$, and construction workers $57.1\%$, among these fall & falling objects caused the greatest number of injuries. 4. The largest group of injuries was fractures $54.8\%$, trauma $14.5\%$, amputation $11.7\%$, open wound, and burns. The largest number of fractures occurred in people in the 30-39 year age group, $63.2\%$ : over 10 years of work, $55.0\%$ ; in work places of 300-490 people, $63.6\%$ ; construction $63.2\%$ and general workers $57.2\%$. 5. The largest group of injuries was upper extremity $45.3\%$, lower extremity $24.0\%$, trunk $18.5\%$ and head or neck $12.2\%$. Of these groups, upper extremity injuries were the highest in those less than 20 years old $75.0\%$, less than 1 year or work $59.5\%$, in work places of 500-999 people $60.0\%$, manufacturing $56.6\%$ and production workers $55.6\%$. 6. Periods of injury showed 34 people injured in September, to be the largest followed by October, 32 ; August, 22 people : July, 19 people and the lowest December, 2 people. During the week, Friday had the largest group injured, 35 people ; followed by Saturday, 26 people and the lowest was Wednesday, 17 people, During the day 1400 hours had the largest group injured, 38 people ; followed by 800 hours, 31 people. 7. On a basis of 5 as the highest mark, the average, according to worker satisfaction showed facility safety 3.55, work environment 3.47, income 3.44, job 3.21 and treatment 2.98. 8. The correlation between general characteristics and injury showed that age was directly correlated to the duration of work (r=2591) p<0.01, age was directly correlated to industry (r=2311) p<0.01, and the duration was directly correlated to occupation (r=4372) p<0.001.

  • PDF

Parameter Estimation of Water Balance Analysis Method and Recharge Calculation Using Groundwater Levels (지하수위를 이용한 물수지분석법의 매개변수추정과 함양량산정)

  • An, Jung-Gi;Choi, Mu-Woong
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.4 s.165
    • /
    • pp.299-311
    • /
    • 2006
  • In this paper it is outlined the methodology of estimating the parameters of water balance analysis method for calculating recharge, using ground water level rises in monitoring well when values of specific yield of aquifer are not available. This methodology is applied for two monitoring wells of the case study area in northern area of the Jeiu Island. A water balance of soil layer of plant rooting zone is computed on a daily basis in the following manner. Diect runoff is estimated by using SCS method. Potential evapotranspiration calculated with Penman-Monteith equation is multiplied by crop coefficients($K_c$) and water stress coefficient to compute actual evapotranspiration(AET). Daily runoff and AET is subtracted from the rainfall plus the soil water storage of the previous day. Soil water remaining above soil water retention capacity(SWRC) is assumed to be recharge. Parameters such as the SCS curve number, SWRC and Kc are estimated from a linear relationship between water level rise and recharge for rainfall events. The upper threshold value of specific yield($n_m$) at the monitoring well location is derived from the relationship between rainfall and the resulting water level rise. The specific yield($n_c$) and the coefficient of determination ($R^2$) are calculated from a linear relationship between observed water level rise and calculated recharge for the different simulations. A set of parameter values with maximum value of $R^2$ is selected among parameter values with calculated specific yield($n_c$) less than the upper threshold value of specific yield($n_m$). Results applied for two monitoring wells show that the 81% of variance of the observed water level rises are explained by calculated recharge with the estimated parameters. It is shown that the data of groundwater level is useful in estimating the parameter of water balance analysis method for calculating recharge.

Conservation and Reproduction of Cheongpung Buwongun Kim Wumyeong's Funeral Bier (청풍부원군 김우명 상여의 보존 및 복제)

  • Jeong, Jaeung;Huh, Ilkwon;Park, Seungwon;Yi, Yonghee
    • Conservation Science in Museum
    • /
    • v.14
    • /
    • pp.91-113
    • /
    • 2013
  • Cheongpung Buwongun Kim Wu-myeong's Funeral Bier, an important folklore cultural property No.120, possessed by Chuncheon National Museum was donated in 2002 (by Kim Seonggu). It consists of a bier, yoyeo(腰輿), myeongjeongdae(銘旌臺), and manjangdae(輓章臺). It has a high value as the oldest royal bier. The bier which had a resting time in the storage for special exhibition of "The great cultural treasure of Gangwon province" was inspected in September 2012 and colored pigment layer of the wooden part had the risk of peeling off and surface damage of the textile was serious. Therefore, conservation treatment was conducted. In addition, knots and susiks(垂飾) were severely damaged and their exhibition was impossible. Therefore, a reproduction to replace them through a close investigation was made. All parts of the funeral bier were in separation except for the basic furniture. Conservation was made by dividing the parts into wooden parts and textile parts. Yoyeo was reinforced after disassembling bujae from it and then was reassembled. Paraloid B-72 2 wt% (in ethyle acetate), acrylic resin, was applied to the wooden part of the bier in order to reinforce the colored pigment layer with the addition of sodium alginate 2 wt%(in stilled water) and glue 4 wt%(in stilled water). The pollutants on the surface of the textile part were removed (vacuuming) and its creases were smoothed out (steaming). Fat-soluble pollutants were removed using an nonionic surfactant(Saponin, concentration at 0.25 to 0.5 g/𝑙, in de-ionized water). After the disassembly of the yoyeo from the broken wooden, it was bonded with glue (3 wt% for the first gluing, 35 wt% for gluing), and pine wood was used to restore missing parts. In the process of connecting Wongak(雲角), the original metal hinge and nails were reused to complete the assembly.

Determination of plasma C16-C24 globotriaosylceramide (Gb3) isoforms by tandem mass spectrometry for diagnosis of Fabry disease (패브리병(Fabry) 진단을 위한 혈장 중 Globotriaosylceramide (Gb3)의 탠덤매스 분석법 개발과 임상 응용)

  • Yoon, Hye-Ran;Cho, Kyung-Hee;Yoo, Han-Wook;Choi, Jin-Ho;Lee, Dong-Hwan;Zhang, Kate;Keutzer, Joan
    • Journal of Genetic Medicine
    • /
    • v.4 no.1
    • /
    • pp.45-52
    • /
    • 2007
  • Purpose : A simple, rapid, and highly sensitive analytical method for Gb3 in plasma was developed without labor-ex tensive pre-treatment by electrospray ionization MS/ MS (ESI-MS/MS). Measurement of globotriaosy lceramide (Gb3, ceramide trihex oside) in plasma has clinical importance for monitoring after enzyme replacement therapy in Fabry disease patients. The disease is an X-linked lipid storage disorder that results from a deficiency of the enzyme ${\alpha}$-galactosidase A (${\alpha}$-Gal A). The lack of ${\alpha}$-Gal A causes an intracellular accumulation of glycosphingolipids, mainly Gb3. Methods : Only simple 50-fold dilution of plasma is necessary for the extraction and isolation of Gb3 in plasma. Gb3 in diluted plasma was dissolved in dioxane containing C17:0 Gb3 as an internal standard. After centrifugation it was directly injected and analyzed through guard column by in combination with multiple reaction monitoring mode of ESI-MS/MS. Results : Eight isoforms of Gb3 were completely resolved from plasma matrix. C16:0 Gb3 occupied 50% of total Gb3 as a major component in plasma. Linear relationship for Gb3 isoforms w as found in the range of 0.001-1.0 ${\mu}g$/mL. The limit of detection (S/N=3) was 0.001 ${\mu}g$/mL and limit of quantification was 0.01 ${\mu}g$/mL for C16:0 Gb3 with acceptable precision and accuracy. Correlation coefficient of calibration curves for 8 Gb3 isoforms ranged from 0.9678 to 0.9982. Conclusion : This quantitative method developed could be useful for rapid and sensitive 1st line Fabry disease screening, monitoring and/or diagnostic tool for Fabry disease.

  • PDF