• Title/Summary/Keyword: STEPPER

Search Result 91, Processing Time 0.029 seconds

Development of pulse diagnosis possible simulator using the stepper motor pumps (스텝 모터 펌프를 이용한 맥진 가능한 시뮬레이터의 개발)

  • Ryu, Geun-Taek;Woo, Sung-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.915-918
    • /
    • 2016
  • Virtual testing devices are required due to rapid changes in the health care industry and the increase of the medical or nursing workforce. The importance of devices such as the simulator, blood vessels, and lab equipment for modeling blood flow to the heart is increasing too. In this study, we made heart pump by using a step motor and developed device which simulates arterial, venous blood pressure, and blood flow. We finally evaluated the function of proposed device. The proposed system is composed of the pump for simulating, the valve device to describe the resistance of the artery and vein, and a reducing device showing the characteristics of the venous system. We used BOXER pump for heart simulator and silicon tube for arterial and venous vessels, and designed a reducing device. We also used the pressure sensor to measure arterial blood pressure. For the evaluation of the proposed system, we selected a range of 50~100mmHg of the blood circuit 60 per minute and then compared the blood pressure of a person and the measured blood pressure.

  • PDF

Automatic Pill Dispenser Based on Arduino (아두이노 기반의 자동 알약 배급기)

  • Kim, Ji-Min;Kim, Min-Ji;Lee, Su-Jin;Kim, Sung-Chan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.854-856
    • /
    • 2016
  • Nowadays, the interests about medical service and health concerting, in other words "Healthcare",are increasing. For healthcare, one of the most convenient and populated methods is taking nutritional supplements like vitamin everyday. According to social currency, we realize ' Automatic Pill Dispenser (APD)' in order to make the storage of pills easy and to help people take pills steadily periodically. First, the APD alerts at the time when the user sets. To prevent polluting pills, if the ultrasonic sensor recognizes user hands, and then after the APD distributes pills through activating the motor. If there are more the APDs, for example, hospitals can manage manpower more efficiently. Furthermore, If it is recorded which and how much pills are distributed automatically, It can be expected that people can take the pills more efficiently and healthfully.

  • PDF

Effect of two types of muscle contraction training on muscle thickness, strength, and delayed onset of muscle soreness in persons with chronic stroke

  • Lim, Seung-yeop;Lee, Wan-hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.7 no.4
    • /
    • pp.154-163
    • /
    • 2018
  • Objective: The purpose of this study was to investigate the effects of eccentric contraction training (ECT) and concentric contraction training (CCT) on the muscle thickness (MT), muscle strength (MS) and delayed onset of muscle soreness (DOMS) of the lower extremities in persons with chronic stroke. Design: Randomized controlled trial. Methods: Thirty persons with chronic stroke were randomly assigned to the ECT or the CCT group. The ECT was performed in a specially designed system of eccentric contraction of both legs and, the CCT was performed using a traditional stepper system for concentric contraction of both legs. The training was performed for 30 min/times, 3 times/wk for 6 weeks. Rehabilitation ultrasound imaging was used to measure MT of the vastus medialis/lateralis (VL), and soleus (SOL), a digital muscle tester was used to measure MS, and a visual analog scale was used to assess DOMS. Results: In the ECT group, MT was significantly improved except for SOL resting (p<0.01). In the CCT group, the MT was significantly improved except for VL contraction (p<0.05). The MS was significantly improved in both groups, especially in the ECT group (p<0.01). In the ECT group, muscle soreness was highest in the first week after training but gradually decreased, and in the CCT group, it was highest in the second week of training but gradually decreased (p<0.01). Conclusions: ECT can improve lower limb MT, MS, and DOMS of chronic stroke survivors. Therefore, it is recommended that ECT be used in the rehabilitation of persons with chronic stroke.

A Study on the Design of Small SMT Platform for Education (교육용 소형 SMT 플랫폼 설계에 관한 연구)

  • Park, Se-Jun
    • Journal of Platform Technology
    • /
    • v.8 no.1
    • /
    • pp.24-32
    • /
    • 2020
  • This paper designed and manufactured a chip mounter based on 3D printer technology that can be used for educational research or sample production to disseminate chip mounter, a core technology of SMT line. A stepper motor with open loop control is used for low cost drive design. The shortcomings of the motor's vibration and disassembly caused by the use of the step motor were compensated by the Micro-Step control method. In the chip mounter experiment, the gerber file was generated on the small chip mounter, printed at the actual size, and the solder cream was printed on the HASL-treated PCB in the same manner as the sample board fabrication. As a result of the experiment, unlike the 2012 micro components, parts such as SOIC and TQFP that require correction are twice as long as the component mounting time, but it can be confirmed that they are mounted relatively accurately. In addition, as a result of repeatedly measuring the error of the initial position 10 times, it was confirmed that a relatively small error of about 0.110mm occurs.

  • PDF

Fatigue performance evaluation of reinforced concrete element: Efficient numerical and SWOT analysis

  • Saiful Islam, A.B.M.
    • Computers and Concrete
    • /
    • v.30 no.4
    • /
    • pp.277-287
    • /
    • 2022
  • Due to the scarcity of extortionate experimental data, fatigue failure of the reinforced concrete (RC) element might be achieved economically adopting nonlinear finite element (FE) analysis as an alternative approach. However, conventional implicit dynamic analysis is expensive, quasi-static method overlooks interaction effects and inertia, direct cyclic analysis computes stabilized responses. Apart from this, explicit dynamic analysis may provide a numerical operating system for factual long-term responses. The study explores the fatigue behavior based on a simplified explicit dynamic solution employing nonlinear time domain analysis. Among fourteen RC beams, one beam is selected to validate under static loading, one under fatigue with the experimental study and other twelve to check the detail fatigue behavior. The SWOT (Strength, Weakness, Opportunities, Threats) analysis has been carried out to pinpoint the detail scenario in the adoption of numerical approach as an alternative to the experimental study. Excellent agreement of FE and experimental results is seen. The 3D nonlinear RC beam model at service fatigue limits is truthful to be used as an expedient contrivance to envisage the precise fatigue behavior. The simplified analysis approach for RC beam under fatigue offers savings in computation to predict responses providing acceptable accuracy rather than the complicated laboratory investigation. At higher frequency, the flexural failure occurs a bit earlier gradually compared to the repeated loading case of lower frequency. The deflection increases by 6%-10% at the end of first cycle for beams with increasing frequency of cyclic loading. However, at the end of fatigue loading, greater deflection occur earlier for higher load range because of more rapid stiffness degradation. For higher frequency, a slight boost in concrete compressive strains at an initial stage of loading has been seen indicating somewhat stepper increment. Stiffness degradation in larger loading cycle at same duration escalates the upsurge of the rate of strain in case of higher frequency.

THE RETROSPECTIVE STUDY ON THE PROGNOSIS OF CLASS III MALOCCLUSION TREATMENTS (III급 부정교합의 치료후 예후에 관한 후향적 고찰)

  • Sung, Jae-Hyun;Kwon, Oh-Won;Kim, Sang-Doo
    • The korean journal of orthodontics
    • /
    • v.28 no.2 s.67
    • /
    • pp.175-187
    • /
    • 1998
  • The purpose of this study was to predict the prognosis of class III malocclusion treatments. 25 patients selected for this study were devided into two groups by the stability of dentitional, skeletal and soft tissue profile improvement. One was stable group which consisted of 12 children and the other was relapse group with 13 children. Various measurements in initial lateral cephalogram were calculated and analyzed by t-test, correlation coefficient and discriminant analysis. The results of this study were summarized as follows 1. In both stable and relapse groups, there was not distinct difference in the antero-posterior skeletal relationship (P<0.05). 2. As the result of wits, hn to occlusal plane angle and occlusal plane to mandubular plane angle, the occlusal plane of relapse group was stepper than that of the stable group. 3. In correlation coefficient analysis, the overjet and the occlusal plane to mandibular plane angle showed significant correlations (p<0.001, p<0.01). 4. The discriminant function was obtained from three major influential measurements; overjet, AB to occlusal plane angle and articular angle, and this function could discriminate correctly in 88% of these samples.

  • PDF

Effects of aerobic and combined exercise on body composition and blood lipid in the middle-aged women (운동형태에 따른 중년여성의 신체구성과 혈중지질의 변화)

  • Kim, Yong Cheol;Kim, Young Soo;Yang, Jeong Ok;Lee, Bom Jin;Lee, Joong Sook
    • Journal of the Korean Data and Information Science Society
    • /
    • v.24 no.6
    • /
    • pp.1241-1251
    • /
    • 2013
  • The purpose of this study was to investigate and compare the effects of aerobic and complex exercise on body composition and blood lipids in the middle-aged women. Sixteen women whose ages ranged in 40 to 50 years were included in the sample of the study. The sample was divided into two groups: (a) aerobic exercise group (n = 8) and (b) combined exercise training group (n = 8). The aerobic exercise program consisted of bicycle ergometer, stepper, and treadmill, whereas; the combined exercise program was designed to improve muscular strength and aerobic capacity. Both programs took place 4 times a week for 12 weeks with the gradual increase of intensity (HRmax 60% 75% and 1 RM 60% 80%). Data were analyzed by nonparametric methods for pre-post within group mean differences (Wilcoxon signed rank test) and for between group mean differences (Wilcoxon rank sum test). Results indicated that there were statistically significant differences in BMI, body fat mass, and triglyceride within the sample of combined exercise; whereas, no significance existed in any variables within the aerobic exercise group. Results also revealed that statistical significance did exist in body fat mass between the combined and aerobic exercise group. These results implies that the combined exercise may be superior to aerobic only excercise for the body composition and blood lipid of the middle-aged women.

KrF 엑시머 레이저를 이용한 웨이퍼 스텝퍼의 제작 및 성능분석

  • 이종현;최부연;김도훈;장원익;이용일;이진효
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.15-21
    • /
    • 1993
  • This paper describes the design and development of a KrF excimer laser stepper and discusses the detailed system parameters and characterization data obtained from the performance test. We have developed a deep UV step-and-repeat system, operating at 248 nm, by retrofitting a commercial modules such as KrF excimer laser, precision wafer stage and fused silica illumination and 5X projection optics of numerical aperture 0.42. What we have developed, to the basic structure, are wafer alignment optics, reticle alignment system, autofocusing/leveling mechanisms and environment chamber. Finally, all these subsystem were integrated under the control of microprocessor-based controllers and computer. The wafer alignment system comprises the OFF-AXIS and the TTL alignment. The OFF-AXIS alignment system was realized with two kinds of optics. One is the magnification system with the image processing technique and the other is He-Ne laser diffraction type system using the alignment grating on the wafer. 'The TTL alignment system employs a dual beam inteferometric method, which takes advantages of higher diffraction efficiency compared with other TTL type alignment systems. As the results, alignment accuracy for OFF-AXIS and TTL alignment system were obtained within 0.1 $\mu\textrm{m}$/ 3 $\sigma$ for the various substrate on the wafers. The wafer focusing and leveling system is modified version of the conventional systems using position sensitive detectors (PSD). This type of detection method showed focusing and leveling accuracies of about $\pm$ 0.1 $\mu\textrm{m}$ and $\pm$ 0.5 arcsec, respectively. From the CD measurement, we obtained 0.4 $\mu\textrm{m}$ resolution features over the full field with routine use, and 0.3 $\mu\textrm{m}$ resolution was attainable under more strict conditions.

  • PDF

Remote Sensing of Atmospheric Trace Species using Multi Axis Differential Optical Absorption Spectroscopy (Multi Axis DOAS를 이용한 대기미량 물질 원격 측정)

  • Lee Chul-Kyu;Kim Young-Joon
    • Korean Journal of Remote Sensing
    • /
    • v.22 no.2
    • /
    • pp.141-151
    • /
    • 2006
  • UV-visible absorption measurement techniques using several horizone viewing directions in addition to the traditional zenith-sky pointing have been recently developed in ground-based remote sensing of atmospheric constituents. The spatial distribution of various trace gases close to the instrument can be derived by combing several viewing directions. Multi-axis differential optical absorption spectroscopy (MAX-DOAS) technique, one of the remote sensing techniques for air quality measurements, uses the scattered sunlight as a light source and measures it at various elevation angles (corresponding to the viewing directions) by sequential scanning with a stepper motor. A MAX-DOAS system developed by GIST/ADEMRC has been applied to measuring trace gases in urban air and plumes of the volcano and fossil fuel power plant in January, May, and October 2004, respectively. MAX-DOAS spectra were analyzed to identify and quantify $SO_2,\;NO_2,\;BrO,\;and\;O_4$ (based on Slant Column Densities, SCD) in the urban air, volcanic plume, and fossil fuel power plant utilizing theirs specific structured absorption features in the UV-visible region. Vertical scan through the multiple elevation angles was performed at different directions perpendicular to the plume dispersion to retrieve cross-sectional distribution of $SO_2\;or\;NO_2$ in the plumes of the volcano and fossil fuel power plant. Based on the estimated cross sections of the plumes the mixing ratios were estimated to 580 $SO_2$ ppbv in the volcanic Plume, and 337 $NO_2\;and\;227\;SO_2$ ppbv in the plume of the fossil fuel power plant, respectively.

Development of Defect Inspection System for Polygonal Containers (다각형 용기의 결함 검사 시스템 개발)

  • Yoon, Suk-Moon;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.25 no.3
    • /
    • pp.485-492
    • /
    • 2021
  • In this paper, we propose the development of a defect inspection system for polygonal containers. Embedded board consists of main part, communication part, input/output part, etc. The main unit is a main arithmetic unit, and the operating system that drives the embedded board is ported to control input/output for external communication, sensors and control. The input/output unit converts the electrical signals of the sensors installed in the field into digital and transmits them to the main module and plays the role of controlling the external stepper motor. The communication unit performs a role of setting an image capturing camera trigger and driving setting of the control device. The input/output unit converts the electrical signals of the control switches and sensors into digital and transmits them to the main module. In the input circuit for receiving the pulse input related to the operation mode, etc., a photocoupler is designed for each input port in order to minimize the interference of external noise. In order to objectively evaluate the accuracy of the development of the proposed polygonal container defect inspection system, comparison with other machine vision inspection systems is required, but it is impossible because there is currently no machine vision inspection system for polygonal containers. Therefore, by measuring the operation timing with an oscilloscope, it was confirmed that waveforms such as Test Time, One Angle Pulse Value, One Pulse Time, Camera Trigger Pulse, and BLU brightness control were accurately output.