• Title/Summary/Keyword: STC

Search Result 230, Processing Time 0.031 seconds

Preparation of Vanadium Dioxide by Hydrogen Reduction of Vanadium Pentoxide and its Thermochromic Properties (오산화바나듐의 수소 환원에 의한 이산화바나듐의 제조 및 열변색 특성)

  • Choi, Seung Hoon;Lee, Chun Boo
    • Resources Recycling
    • /
    • v.26 no.5
    • /
    • pp.61-66
    • /
    • 2017
  • Vanadium Dioxide has been investigated for use as a "spectrally-selective" window coating to block infrared transmission and reduce the loss of building interior heat through windows. The preparation of thermochromic $VO_2$ powder by the reductive reaction with hydrogen was studied. The reductive reaction method has many advantages of easy and mass production of $VO_2$ powder according to controlled reaction without semi-conductor equipments like sputter and beam evaporator. The reaction temperature, time, concentration of reductive gas, post-annealing condition and W addition as dopant would affect the characterization of $VO_2$ powder and its thermochromism. Many applications for electrical device and energy-saving technologies is expected.

Analysis of Power Generation Characteristics of a Photovoltaic System in Korea (태양광발전시스템 국내 지역별 발전특성 분석)

  • Lee, Hyun-Seung;Kim, Beob-Jeon;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.2
    • /
    • pp.33-43
    • /
    • 2019
  • In this study, reflecting long-term climate characteristics, we analyzed electricity generation and generation characteristics of 3kWp PV system, which was semi-integrated with air duct behind. Using PVsyst as a simulation analysis tool, we inputted "National reference standard weather data" of 16 regions as a typical climatic data. The result is summarized as follows: First, the national average annual electricity generation was 1,312 kWh/kWp (StDev, ${\sigma}=71$). It was most abundant in Mokpo with 1,434 kWh/kWp, which was average 21% greater than the lowest with 1,165 kWh/kWp in Seoul and 1,197 kWh/kWp in Jeju. National average daily generating time based on STC was 3.6 hours (${\sigma}=0.43$), and that of Mokpo and Seoul was 3.9 and 3.2 hours respectively. Second, Jeju showed the great difference of annual monthly generation by month (annual average = 99.7 kWh/kWp, ${\sigma}=25.5$), while Jinju showed the smallest difference (annual average = 115.5 kWh/kWp, ${\sigma}=10.6$). Generation in Jeju was at the largest in April with 132.2 kWh/kWp, which was 2.3 times greater than the lowest 55.2 kWh/kWp in January. However, generation in Jinju was at the largest in March with 129.3 kWh/kWp, which was only 1.3 times greater than the lowest 101.1 kWh/kWp in June. Third, the annual average PR was the highest in Incheon with 85.8% and the lowest in Jeju with 83.2%. PR of Mokpo was 84.3%, which was lower than that of national average.

The Association Between Serum Lipid profiles and periodontitis on Convergence (혈청지질분포와 치주질환간의 연관성에 관한 융합연구)

  • Kim, Song Sook;Kim, Ji hyun
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.1
    • /
    • pp.239-244
    • /
    • 2019
  • The aim of this study was to evaluate the association between Lipid profiles and periodontal diseases in Korea adults. The date from the 2013, 2014 Korean National Health and Nutrition Survey were used, and 8,854 subjects over 30 years were included in the analysis. periodontal disease was assessed using the Community periodontal Index. Study participants with HDL between ${\leq}40mg/dL$(high) were 1.39 times(95% CI=1.16 to 1.66) as likely to have periodontal disease as those with normal levels and those with Triglyceride ${\geq}200mg/dL$(high) were 1.14 times(95% CI=1.02 to 1.27) as likely to have periodontal disease as those with normal levels. positive significant association was observed between serum lipid profiles and periodontal disease; however, further studies need to be conducted to understand the actual relationship between STC levels and periodontitis and to establish causality and directional association.

Reverse Engineering Procedure of Metal Brake Pad for Part 25 Aircraft (수송류 항공기용 금속계 제동패드의 역설계 절차)

  • Min-ji Kim;Kyung-il Kim;Kyung-taek Kim
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.5
    • /
    • pp.621-628
    • /
    • 2023
  • This study derived a reverse engineering procedure for verifying the design identity of original parts and developed parts for PMA(Parts Manufacturer Approval) and STC(Supplemental Type Certificate) of metal brake pads for transport aircraft, which are critical parts among aircraft parts and equipment. In Korea, the regulations for reverse engineering procedures are regulated by the Parts Manufacturer Approval Guidelines, and in the United States, AC No. 21. 303-4. In the reverse engineering for the brake pad, the detailed procedures for each component were determined by selecting verification test items to confirm identity based on sample quantity, dimensional tolerance, mechanical property measurement, material, weight and volume characteristics for each component. In addition, as a result of analyzing the regulation of Korea and United States, in the case of Korea, it is necessary to establish technical standards for braking systems for transport aircraft and regulations related to flight tests.

A Study on Water Contact Angle and Peel Strength by Anti- Adhesion Coating on Die Blade Materials for Adhesive Film Cutting (점착필름 절단용 다이 칼날 소재에 적용된 점착 방지 코팅의 물 접촉각 및 박리강도에 관한 연구)

  • Yujin Ha;Min-Wook Kim;Wook-Bae Kim
    • Tribology and Lubricants
    • /
    • v.39 no.5
    • /
    • pp.190-196
    • /
    • 2023
  • Anti-adhesion coatings are very important in the processing of adhesive materials such as optical clear adhesive (OCA) films. Choosing the appropriate release coating material for dies and tools can be quite challenging. Hydrophobic surface treatment is usually performed, and its performance is often estimated by the static water contact angle (CA). However, the relationship between the release performance and the CA is not well understood. In this study, the water CAs of surfaces coated with anti-adhesion materials and the peel strengths of the acrylic-based adhesive films are evaluated. STC5 and SUS304 are selected as the base materials. Base materials with different surface roughnesses are produced by hairline finishing, mirror-polishing, and end milling. Four fluoropolymer compounds, including a self-assembled monolayer, are selected to make the base surface hydrophobic. Static, advancing, and receding CAs are mostly increased due to the coating, but the CA hysteresis is found to increase or decrease depending on the coating material. The peel strengths all decreased after coating and are largely dependent on the coating material, with significantly lower values observed for fluorosilane and perfluoropolyether silane coatings. The peel strength is observed to correlate better with the static CA and advancing CA than with the receding CA or hysteresis. However, it is not possible to accurately predict the anti-adhesion performance based on water CA alone, as the peel strengths are not fully proportional to the CAs.

Dynamometer Test Procedure of Metal Brake Pad for Part 25 Aircraft (수송류 항공기용 금속계 제동패드의 다이나모시험 절차)

  • Min-ji Kim;Kyung-il Kim;Kyung-taek Kim
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.6
    • /
    • pp.821-827
    • /
    • 2023
  • In this study, the aircraft technical standards of the Korea and the United States were analyzed to derive the dynamometer test procedure required to prove the compatibility for flight test certification of the metal brake pad for transport aircraft. Since the design modification of the brake systems is classified as a major change, the STC(Supplemental Type Certificate) and the PMA(Parts Manufacturer Approval) are required. In accordance with the TSO-C135a, the technical standard order for brake system in the United States, the design landing-stop test, accelerate-stop test, and most severe landing stop test were selected among the test items for flight test. The conditions for the dynamometer test are determined according to the specifications provided by aircraft manufacturer, and the brake pad condition, deceleration, and the number of test are defined according to the TSO-C135a.

Characterization of Respirable Suspended Particles and Polycyclic Aromatic Hydrocarbons associated with Environmental Tobacco Smoke

  • Baek, Sung-Ok;Park, Jin-Soo;Kim, Mi-Hyun;Roger A, Jenkins
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.E
    • /
    • pp.1-17
    • /
    • 2000
  • In this study, the concentrations of particulate organic constituents of environmental tobacco smoke(ETS) were determined using an environmental smog chamber, where ETS is the sole source of target compounds. ETS was generated in a 30 ㎥ environmental chamber by a number of different cigarettes, including the Kentucky 1R4F reference cigarette and eight commercial brands. A total of 12 experimental runs was conducted, and target analytes included a group of ETS markers both in vapor and particulate phase and a class of polycylic aromatic hydrocarbos(PAHs) associated with ETS particles. The mass concentrations of PAH in ETS particles were also determined. The average contents of benzo(a) pyrene and benzo(a) anthracene in ETS particles for the commercial brands were 12.8 and 21.5$\mu\textrm{g}$/g, respectively, There values are all somewhat higher than those determined previously by other studies. Results form the chamber study are further used to estimate the average and variability of cigarette yields for target compounds associated with ETS. Finally, ratios of RSP to the surrogate standards of UVPM, FPM and solanesol were calculated for each sample. The average conversion factors factors for the eight commercial brands were 7.3, 38, and 41 for UVPM, EPM, and solanesol, respectively. The UVPM and FPM factors are in good agreement with the recently published values. Whereas there might be a substantial difference in the solanesol content among cigarettes produced in different countries, the variability is somewhat greater than those of UVPM and FPM, Unfortunately, comparison of the PAH yield data from this study with literature values was complicated by a lack of consistency in cigarette smoke generating methodology. Validation of the PAH yields was also difficult due to a lack of information on the ETS related PAH in the literature. From and engineering viewpoint , however, these data on the cigarette yields of ETS components may still provide useful information to studies on the mathematical modeling of indoor air quality management regarding tobacco smoke as a source of interest, or to studies on the assessment of human exposure to ETS.

  • PDF

Investigation of the sound insulation performance of walls and flanking noises in classrooms using field measurements (현장실험을 통한 학교교실의 벽체 차음성능 및 측로전달소음 조사)

  • Ryu, Da-Jung;Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.5
    • /
    • pp.329-337
    • /
    • 2017
  • In USA and UK, the standards of both reverberation time and background noise level have been established for the appropriate aural environment in classrooms. In order to realize this, guidelines for architectural planning and interior finishing have been also suggested. However, in Korea, there has hardly been any guidelines for satisfying background noise criteria and investigation about sound insulation performance of current walls of classrooms. The present study investigates the structure of outer wall and walls between classrooms of two middle schools in order to analyze the sound insulation performance against both exterior and interior noises. Acoustic parameters including transmission loss, standardized sound level difference, and signal to noise ratio have been measured and analyzed for sound insulation performance of walls and flanking noises. As a result, concerning the walls in between classrooms, it was found that walls of dry construction have greater sound insulation performance rather than the walls of wet construction especially in mid and high frequency bands. Also, It was revealed that thermopane, insulated pair glass, of outer walls, has greater sound insulation performance than the double window consisted of two single pane glass. Regarding flanking noises, the standards were exceeded when all windows, or windows and doors front onto corridor were opened. It denotes that students could be disturbed with the sound transmission by the interior noises.

Dissolution and Duodenal Permeation Characteristics of Lovastatin from Bile Salt Solid Dispersions (담즙산염과의 고체분산체로부터 로바스타틴의 용출 및 십이지장 점막 투과 특성)

  • Chun, In-Koo
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.2
    • /
    • pp.97-106
    • /
    • 2009
  • Although lovastatin (LS) is widely used in the treatment of hypercholesterolemia, its bioavailability is known to be around 5%. This study was aimed to increase the solubility and dissolution-permeation rates of LS using solid dispersions (SDs) with bile salts. The solubilities of LS in water, aqueous bile salt solutions and non-aqueous vehicles were determined, and effects of bile salts on the cellulose or duodenal permeation of LS from SDs were evaluated using a horizontal permeation system. SDs were prepared at various ratios of LS to carriers, such as sodium deoxycholate (SDC), sodium glycocholate (SGC) and/or 2-hydroxypropyl-$\beta$-cyclodextrin (HPCD). The addition of bile salts (25 mM) in water increased markedly the solubility of LS by the micellar solubilization. Some non-aqueous vehicles were effective in solubilizing LS. From differential scanning calorimetric studies, it was found that the crystallinity of LS in SDs disappeared, indicating a formation of amorphous state. The SDs showed markedly enhanced dissolution compared with those of their physical mixtures (PMs) and drug alone. In the dissolution-permeation studies using a cellulose membrane, the donor and receptor solutions were maintained as a sink condition using pH 7.0 phosphate buffer containing 0.05% sodium lauryl sulfate (SLS). The flux of LS alone was nearly same as that of LS-SDC-HPCD (1:3:6) PM. However, the flux of LS-SDC-HPCD (1:3:6) SD slightly increased compared with drug alone and PM, suggesting that entrapment of LS in micelles does not significantly hinder the permeation across cellulose membrane. In the dissolution-duodenal permeation studies using a LS-HPCD-SDC (1:3:6) SD, the addition of various bile salts in donor solutions (25 mM) enhanced the permeation of LS markedly, and the fluxes were found to be $0.69{\pm}0.41$, $0.87{\pm}0.51$, $0.84{\pm}0.46$, $0.47{\pm}0.17$ and $0.68{\pm}0.32{\mu}g/cm^2/hr$ for sodium cholate (SC), SDC, SGC, sodium taurodeoxycholate (STDC) and sodium taurocholate (STC), respectively. The stepwise increase of donor SGC concentration increased the flux dose-dependently. From the relationship of donor SGC concentration and flux, the concentration of SGC initiating the permeation across the duodenal mucosa was calculated to be 11.1 mM, which is nearly same as the critical micelle concentration (CMC, 11.6 mM) of SGC. However, with no addition of bile salts and below CMC, the permeation was very limited and irratic, indicating that LS itself is very poor permeable. Higher protions of bile salt in SD such as LS-SDC or LS-SGC (1 : 49 and 1 : 69) showed highly promoted fluxes. In conclusion, SD systems with bile salts, which may form their micelles in intestinal fluids, might be a promising means for providing enhanced dissolution and intestinal permeation of practically insoluble and non-absorbable LS.

Inhibitory Effects of ${\gamma}$-Aminobutyric Acid on the Contractility of Isolated Rat Vas Deferens (흰쥐의 적출 정관 수축성에 대한 ${\gamma}$-Aminobutyric Acid의 억제작용)

  • Ahn, Ki-Young;Kwon, Oh-Cheol;Ha, Jeoung-Hee;Lee, Kwang-Youn;Kim, Won-Joon
    • Journal of Yeungnam Medical Science
    • /
    • v.9 no.2
    • /
    • pp.382-395
    • /
    • 1992
  • GABA is an inhibitory neurotransmitter in central nervous system and produce sedative, antianxiety and muscle reaxing effects via $GABA_A$ receptor or $GABA_B$ receptor. Recently it is known that GABA is widely distributed throughout peripheral organs and may playa physiological role in certain organ. The vas deferens is innervated by species-difference. These study, therefore, was performed to investigate the mode and the mechanism of action of GABA on the norepiniphrine-, ATP- and electric stimulation-induced contraction of vas deferens of rat. Sprague-Dawley rats were sacrificed by cervical dislocation. The smooth muscle strips were isolated from the prostastic portion and were mounted in the isolated muscle bath. PSS in the bath was aerated with 95/5%-$O_2/CO_2$ at $33^{\circ}C$. Muscle tensions were measured by isometric tension transducer and were recorded by biological recording system. 1. GABA, muscimol, a $GAB_A$ agonist, and baclofen, a $GABA_B$ agonist inhibited the electric field stimulation(EFS, 0.2Hz, 1mSec, 80 V, monophasic square wave)-induced contraction with a rank order of potency of GABA greater than baclofen greater than muscimol. 2. The inhibitory effect of GABA was antagonized by delta aminovaleric acid(DAVA), a $GABA_B$ antagonist, but not by bicuculline, a $GABA_A$ mtagonist. 3. The inhibitory effect of baclofen was antagonized by DAVA, but the effect of muscimol was not antagonized by bicuculline. 4. Exogenous norepinephrine(NE) and ATP contracted muscle strip concentration dependently, but the effect of acetylcholine was negligible : and GABA did not affect the NE-and ATP-induced contractions. 5. GABA, baclofen and muscimol did not affect basal tone, and GABA did not affect the NE-and ATP-induced contractionsm 6. EFS-induced contraction was including 2 distinctable components. The first phasic component was inhibited by beta gamma-methylene ATP(mATP), a desensitizing agent of APT receptor and the second tonic component was reduced by pretreatment of reserpine(3 mg/Kg, IP). 7. GABA inhibited the EFS-induced contraction of reserpinized strips, but not the mATP-treated strips. These results suggest that in the prostatic portion of the rat vas deferens, adrenergic and purinergic neurotransmissions are exist, and GABA inhibits the release of ATP via presynaptic $GABA_B$ receptor on the excitatory neurons.

  • PDF