Abstract
In this study, reflecting long-term climate characteristics, we analyzed electricity generation and generation characteristics of 3kWp PV system, which was semi-integrated with air duct behind. Using PVsyst as a simulation analysis tool, we inputted "National reference standard weather data" of 16 regions as a typical climatic data. The result is summarized as follows: First, the national average annual electricity generation was 1,312 kWh/kWp (StDev, ${\sigma}=71$). It was most abundant in Mokpo with 1,434 kWh/kWp, which was average 21% greater than the lowest with 1,165 kWh/kWp in Seoul and 1,197 kWh/kWp in Jeju. National average daily generating time based on STC was 3.6 hours (${\sigma}=0.43$), and that of Mokpo and Seoul was 3.9 and 3.2 hours respectively. Second, Jeju showed the great difference of annual monthly generation by month (annual average = 99.7 kWh/kWp, ${\sigma}=25.5$), while Jinju showed the smallest difference (annual average = 115.5 kWh/kWp, ${\sigma}=10.6$). Generation in Jeju was at the largest in April with 132.2 kWh/kWp, which was 2.3 times greater than the lowest 55.2 kWh/kWp in January. However, generation in Jinju was at the largest in March with 129.3 kWh/kWp, which was only 1.3 times greater than the lowest 101.1 kWh/kWp in June. Third, the annual average PR was the highest in Incheon with 85.8% and the lowest in Jeju with 83.2%. PR of Mokpo was 84.3%, which was lower than that of national average.
Keywords
Perfornance Ratio; Photovoltaic System; TMY(Typical Meteorological Year); TRY(Test Reference Year);
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Park, S. H. and Seo, J. H., A Study on the Photovoltaic Module Layout Considering the Azimuth and Inclination in Region, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 24, pp. 461-466, 2012   DOI
2 Kim, S. H., Lee, Y. H., Hwang, J. H., and Cho, Y. H., A Study on Method for Improving Renewable Energy Supply Ratio for the School Building Applied PV System, Journal of the Korean Solar Energy Society, Vol. 33, pp. 42-49, 2013.
3 Jung, S. M., Chung, M. H., Park, J. C., and Rhee, E. K., A Study on the Application of Solar Energy System in Apartment Complex, Journal of 2009 Spring Conference of 'The Korean Solar Energy Society', pp. 43-48, 2009.
4 An, Y. S., Kim, S. T., Chae, K. J., Kang, J. H., and Yang, H. J., Estimation of Energy Self-sufficiency in Municipal Wastewater Treatment Plant Using Simulated Solar Photovoltaic Performance, Journal of 2011 Winter Conference of The Korean Solar Energy Society, pp. 291-296, 2011.
5 PVsyst User's manual, PVSYST SA, 2014.
6 Kim, B. J., Park, J. W., Yoon, J. H., and Shin, U. C., The Development of Performance Evaluation Program of Building Integrated Photovoltaic System, KIEAE Journal, Vol. 15, No. 4, pp. 85-90, 2015.   DOI
7 Jin, C. K. and Kyung, N. K., Study on the Regional Differences of Optimal Orientation and Tilt Angle for Photovoltaic Systems : Simulations by a System Advisor Model, The Korean Society for New and Renewable Energy, Vol. 14, pp. 9-20, 2018.   DOI
8 Ministry of Trade, Industry and Energy, Plan for the Implementation of 3020 of Renewable Energy, 2017.
9 KOrean Statistical Information Service, http://kosis.kr/search/search.do?query=태양광
10 Kim, D.S., Shin, U.C., and Yoon, J.H., Annual Energy Yield Prediction of Building Added PV System Depending on the Installation Angle and the Location in Korea, The International Journal of The Korea Institute of Ecological Architecture and Environment, Vol. 14, pp. 67-74, 2014.
11 Chang, H. S., Power Output in Various Types of Solar Panels in the Central Region of Korea, Journal of the Korean Solar Energy Society, Vol. 38, pp. 37-44, 2018.
12 Lee, G. M. and Hwang, C. G., Analysis on the Generation Characteristics of the 1 MW PV Plant in the Jeju Island, The Transactions of The Korean Institute of Electrical Engineers, Vol. 64, pp. 726-731, 2015.   DOI
13 Oh, S. I., Ihm, P. C., and Lee, K. H., Optimal Electric Generation for Fixed-Type Photovoltaic System Installed for Residential Building in Korea, GRI REVIEW, Vol. 14, pp. 271-288, 2012.
14 Lee, H. J., Kim, S. Y., and Yun, C. Y., Generation of Typical Meteorological Year Data Suitable for Solar Energy Systems and Aalysis of Solar Irradiance Data, New & Renewable Energy, Vol. 13, pp. 24-32, 2017.   DOI
15 Yoo, H. C., Creation of standard weather data for major cities in Korea, The Magazine of Korean Solar Energy Society, Vol. 8, pp. 42-45, 2009.
16 ASHRAE 2018, http://ashrae.whiteboxtechnologies.com/faq#Q1
17 Handbook part 1 : Software., METEOTEST
18 www.srd.re.kr
19 www.kier.re.kr
20 Noh, J. Y. and Hwang, D. K., Photovoltaic System Performance Analysis in a Apartment, Journal of 2012 Summer Conference of 'The Society of Air-Conditioning and Refrigerating Engineers of Korea', pp. 650-654, 2012.
21 Kim, B. J., Kim, D. S., Lim, H. W., Lee, W. J. and Shin, U. C., Case Analysis on Electric Load Matching of Photovoltaic House, Journal of 2017 Spring Conference of 'The Korean Society for New and Renewable Energy', pp. 180, 2017.
22 Hong, S. K., Cho, Y. J. and Choi, A. S., Comparison of Meteorological Data of KMA and Measured Data for Feasibility Analysis of Photovoltaic Systems, The Korean Institute of Illuminating and electrical Installation Engineers, Proceedings of KIIEE Annual Conference, pp. 27, 2017.
23 Yoon, J. H., Shin, U. C., and Park, J. W., Software Development on Power and Economic Analysis of Photovoltaic System for Building Application, Journal of the Korean Solar Energy Society, Vol. 28, pp. 1-8, 2008.
24 Hwang, G. H., Kim, W. G., Yun, J. B., and Jung, D. Y., A Study on Simulation of Photovoltaic Module for Stand-Alone Photovoltaic System, Journal of the Korean Institute of Illuminating and Electrical Installation Engineers, Vol. 23, pp. 131-137, 2009.   DOI
25 Jeon, J. P. and Kim, K. H., An Optimal Decision Model for Capacity and Inclining Angle of Residential Photovoltaic Systems, The transactions of The Korean Institute of Electrical Engineers, Vol. 59, pp. 1046-1052, 2010.   DOI
26 No, S. T., Comparison of Measured and Predicted Photovoltaic Electricity Generation and Input Options of Various Softwares, KIEAE Journal, Vol. 14, pp. 87-92, 2014.
27 Kim, D. S., Kim, B. J. and Shin, U. C., Evaluation of Electricity Generation According to Installation Type of Photovoltaic System in Residential Buildings, Journal of the Korean Solar Energy Society, Vol. 37, pp. 35-45, 2017.