• 제목/요약/키워드: STATic synchronous COMpensator

검색결과 134건 처리시간 0.028초

Fault Immune Pico-Hydro Powered Base Station of Remote Telecommunication Tower

  • Verma, Vishal;Pant, Peeyush;Singh, Bhim
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1612-1620
    • /
    • 2016
  • This paper presents the dynamic excitation control of a siphon-turbine coupled pico-hydro powered cage rotor induction generator and load matching for off-grid electricity generation. Through the proposed dual-role of the current-controlled voltage source converter (VSC), acting as static synchronous compensator and load controller, real and reactive power are dynamically controlled in a decoupled manner with a self supported DC-bus. The proposed scheme entails minimal computation for ensuring the rated (set) capacity of real power. The scheme also exhibits fault immunity for protection, thus enabling the effective handling of constant power electrical loads presented by base telecom station towers in remote locations. The performance of the system is evaluated under MATLAB/Simulink and is experimented through a developed hardware prototype. Simulation and experimental results show close conformity and validate the effectiveness of the proposed scheme.

교류 전기철도 시스템의 해석에 적합한 조류계산 기법 및 STATCOM을 적용한 전압 강하 개선 연구 (A Study on a New Power Flow Method for Analysis of AC Electric Railway System and Improvement of Voltage Drop Using a STATCOM)

  • 백정명;이병하
    • 전기학회논문지
    • /
    • 제56권4호
    • /
    • pp.669-676
    • /
    • 2007
  • This paper presents a new power flow method to analyze the AC electric railway system effectively in both cases of traction and regenerative braking of the trains. The algorithm to easily solve the power flow of the AC electric railway system with the trains of regenerative braking from the system without a train of regenerative braking is derived. Using this new power flow method, the voltage characteristics of a typical AC electric railway system is easily analyzed in both cases of traction and regenerative braking of the trains. We show that the presented method can be applied effectively in order to analyze the AT-fed AC electric railway system in both cases of traction and regenerative braking of the trains. A STATCOM(Static Synchronous Compensator) is applied to the system in order to improve the voltage drop problem and this case is also analyzed to show the effect of STATCOM.

Implementation of a No Pulse Competition CPS-SPWM Technique Based on the Concentrated Control for Cascaded Multilevel DSTATCOMs

  • Wang, Yue;Yang, Kun;Chen, Guozhu
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1139-1146
    • /
    • 2014
  • Digital signal processor (DSP) and field programmable gate array (FPGA) based concentrated control systems are designed for implementing CPS-SPWM strategies. The self-defined universal asynchronous receiver/transmitter (UART) protocol is used for communication between a master controller and an individual module controller via high speed links. Aimed at undesired pulse competition, this paper analyzes its generation mechanism and presents a new method for eliminating competition pulses with no time delay. Finally, the proposed concentrated controller is applied to a 10kV/10MVar distribution static synchronous compensator (DSTATCOM) industrial prototype. Experimental results show the accuracy and reliability of the concentrated controller, and verify the superiority of the proposed elimination method for competition pulses.

SSSC 투입에 따른 연계선로의 송전운용한계 개선 (Enhancement of Interface Flow Limit using Static Synchronous Series Compensator(SSSC))

  • 김슬기;송화창;이병준;권세혁;장병훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.28-30
    • /
    • 2000
  • This paper introduces a power flow model of SSSC for voltage stability study. The SSSC model is obtained from the injection model of voltage source inverter by adding the condition that SSSC injection voltage is in quadrature with current of SSSC-installed branch. This model is incorporated into modified CPF algorithm to study effects of SSSC on the security-constrained interface flow limit. Determination of interface flow limit is simply briefed. In case study a 771-bus real system is used to show that SSSC can improve interface flow limit in terms of voltage stability.

  • PDF

Recursive Design of Nonlinear Disturbance Attenuation Control for STATCOM

  • Liu Feng;Mei Shengwei;Lu Qiang;Goto Masno
    • International Journal of Control, Automation, and Systems
    • /
    • 제3권spc2호
    • /
    • pp.262-269
    • /
    • 2005
  • In this paper, a nonlinear robust control approach is applied to design a controller for the Static Synchronous Compensator (STATCOM). A robust control dynamic model of STATCOM in a one-machine, infinite-bus system is established with consideration of the torque disturbance acting on the rotating shaft of the generator set and the disturbance to the output voltage of STATCOM. A novel recursive approach is utilized to construct the energy storage function of the system such that the solution to the disturbance attenuation control problem is acquired, which avoids the difficulty involved in solving the Hamilton-Jacobi-Issacs (HJI) inequality. Sequentially, the nonlinear disturbance attenuation control strategy of STATCOM is obtained. Simulation results demonstrate that STATCOM with the proposed controller can more effectively improve the voltage stability, damp the oscillation, and enhance the transient stability of power systems compared to the conventional PI+PSS controller.

대전력용 직렬형 멀티레벨 인버터 이용한 STATCOM의 새로운 제어기법 (Novel Control of STATCOM Using Cascade Multilevel Inverter for High Power Application)

  • 민완기;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.136-141
    • /
    • 2000
  • This paper proposes the novel control of a static synchronous compensator (STATCOM). This STATCOM system consists of cascade multilevel inverter which employs H-bridge inverter(HBI) The STATCOM system is modeled in the d-q transform matrix. This model is used to design a controller. The selective harmonic elimination method(SHEM) allows to keep the total harmonic distortion (THD) low in the output voltage. The switching method produces the staircase type waveform in cascade multilevel inverter. To balance the DC voltages in HBIs capacitor, the rotated switching scheme is newly proposed in this paper. The proposed control scheme is verified in the simulated results.

  • PDF

IPLAN을 이용한 SSSC 조류계산 모델 (SSSC model for Power Flow Study using IPLAN)

  • 국경수;김학만;이영운;오태규;장병훈;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1164-1166
    • /
    • 1999
  • This paper presents Static Synchronous Series Compensator(SSSC) model for power flow study using IPLAN. In the proposed model, SSSC is represented by the equivalent load variation. The equivalent load consists of active power load specified by user and reactive power load which is founded for considering characteristic of SSSC. And this is implemented by IPLAN which is a macro-external program for PSS/E. Using this model, SSSC can be solved in load-flow by just calling the model in PSS/E. The proposed model was applied to a realistic power system for validity test.

  • PDF

SSSC로 보상된 송전 선로의 거리계전 알고리즘에 관한 연구 (A Study on a Distance Relaying Algorithm for Transmission Line Compensated with SSSC)

  • 양진우;남순열;손진만;박종근;강용철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1401-1403
    • /
    • 1999
  • This paper presents a distance relaying algorithm for transmission line compensated with Static Synchronous Series Compensator (SSSC). The compensation voltage driven by SSSC is calculated from the line current measured at a relaying point Then the compensation voltage is subtracted from the voltage measured by the relay. We can apply conventional distance relaying algorithm with this subtracted voltage to locate a fault. The results of case studies using EMTP (Electro-Magnetic Transient Program) show the proposed algorithm has higher precision.

  • PDF

제주계통의 STATCOM 상정사고를 고려한 전력품질 해석 (Power Quality Analysis Considering Contingency of STATCOM in Jeju Power Grid)

  • 고지한;김동완;김승현;김호민;김일환
    • 한국태양에너지학회 논문집
    • /
    • 제34권2호
    • /
    • pp.91-97
    • /
    • 2014
  • This paper presents the modeling and contingency analysis of Jeju power system. For the analysis of contingency with simulation, thermal power plants, current source type HVDC systems, wind farms, STATCOMs and Jeju power load are modeled by PSCAD/EMTDC program. And three kinds of simulation are carried out. Firstly, two STATCOMSs are in normal operation. Secondly, one STATCOM is in fault. Lastly, all of STATCOMs are in fault. These comparative studies will be useful for evaluating the effectiveness of STATCOM to stabilize for the Jeju power system.

FACTS를 이용한 유효송전용량 증가를 통한 과도안정도 분석 (Transient Stability Analysis on Increasing Available Transfer Capacity Using FACTS Device)

  • 최동희;정광우;박정욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.201-202
    • /
    • 2015
  • 전력계통이 대형화, 복잡화됨에 따라 현재의 전력전송은 한계 전송량에 가깝게 운영되고 있다. 또한 정치적, 경제적, 사회적 수용성 등의 이유로 전력을 융통하기 위한 신규 초고압 송전선로의 건설도 어려운 실정이다. 이 때 루트 송전선로의 탈락은 계통의 과도안정도에 큰 영향을 끼칠 수 있으며, 발전기 탈락을 통하여 계통을 안정화 시킬 수 있다. 하지만 과도한 발전기 탈락은 계통의 신뢰성 있는 운영에 방해물이 될 수 있다. 유연송전기기(FACTS, Flexible AC Transmission Systems)는 이러한 루트 선로 탈락에 따른 발전기 탈락을 최소화 할 수 있다. 본 논문에서는 FACTS의 한 종류인 STATCOM(Static Synchronous Compensator)을 이용하여 사고 시, FACTS 기기 설치 유무에 따른 과도안정도 분석을 진행한다.

  • PDF