Fault Immune Pico-Hydro Powered Base Station of Remote Telecommunication Tower

  • Verma, Vishal;Pant, Peeyush;Singh, Bhim
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1612-1620
    • /
    • 2016
  • This paper presents the dynamic excitation control of a siphon-turbine coupled pico-hydro powered cage rotor induction generator and load matching for off-grid electricity generation. Through the proposed dual-role of the current-controlled voltage source converter (VSC), acting as static synchronous compensator and load controller, real and reactive power are dynamically controlled in a decoupled manner with a self supported DC-bus. The proposed scheme entails minimal computation for ensuring the rated (set) capacity of real power. The scheme also exhibits fault immunity for protection, thus enabling the effective handling of constant power electrical loads presented by base telecom station towers in remote locations. The performance of the system is evaluated under MATLAB/Simulink and is experimented through a developed hardware prototype. Simulation and experimental results show close conformity and validate the effectiveness of the proposed scheme.

EMTP MODELS를 이용한 전기철도 FACTS 설비의 제어 구현 연구 (A Study on control realization of FACTS equipment in Electric Railway Systems using EMTP MODELS)

  • 오민혁;이병하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.329-330
    • /
    • 2006
  • The purpose of this paper is to compensate the voltage drop of the power system in the AC Electric Railway Systems. Reactive power compensation is often the most effective way to improve system voltage drop. The suitable modeling of the electric railway system should be applied to the EMTP. the dynamic characteristics of 3-Phase Induction Motor in Electric Railway Systems is considered for precise modeling. it is shown through EMTP simulation using EMTP MODELS that voltage drop can be compensated effectively by STATCOM.

  • PDF

대규모 전력계통에서의 하위 송전계통 축약을 이용한 FACTS 위치선정 연구 (Subtransmission Reduction for FAGTS Site Selection in Large Power System)

  • 장병훈;추진부;권세혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1302-1304
    • /
    • 1999
  • This Paper Proposes the FACTS site selection method using subtransmission system reduction. A general method which uses the sensitivity of the variation in voltage and reactive Power has been used to determine the location of shunt type FACTS device, but there is a difficulty to find a proper location due to the overestimation of the effect of sub-transmission systems. Therefore, there is a need to reduce sub-transmission system for finding an effective location of shunt type FACTS devices such as SVC(Static Var Compensator), STATCOM(Static Synchronous Compesator), and so on.

  • PDF

3-레벨 반브리지 인버터로 구성된 새로운 UPFC의 동특성 분석 (Dynamic Characteristic Analysis of Novel Unified Power Flow Controller Using 3-Level Half-Bridge Inverter Modules)

  • 백승택;소용철;한병문
    • 전기학회논문지P
    • /
    • 제53권3호
    • /
    • pp.116-121
    • /
    • 2004
  • This paper proposes a novel UPFC based on 3-level Half-bridge modules, isolated through single-phase multi-winding transformers. The dynamic performance of proposed system was analyzed by simulation with EMTDC, assuming that the UPFC is connected with the 138-kV transmission line of one-machine-infinite-bus power system. The proposed system can be directly connected to the transmission line without series injection transformers. It has flexibility in expanding the operation voltage by increasing the number of 3-level Half-bridge modules.

싸이리스터 전류원인버터를 이용한 새로운 무효전력보상기 (New Reactive-Power Compensator using Thyristor Current-Source Inverter)

  • 백승택;한병문
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권4호
    • /
    • pp.219-225
    • /
    • 1999
  • This paper proposes a new reactive-power compensator composed of a thyristor current-source inverter. The compensator consists of a 6-pulse thyristor bridge, dc reactor, and a commutation circuit. The commutation circuit offers the thyristor bridge to have PWM operation with minimal switching losses. The operation of proposed system was analyzed by computer simulations with EMTP and experimental works with hardware scaled-model. The proposed system would have low cost and easy expansion of operation voltage due to using the conventional thyristors.

  • PDF

다중브리지 PWM 인버터로 구성된 SSSC의 동특성 분석 (Dynamic Characteristics Analysis of Multi-bridge PWM Inverter SSSC)

  • 한병문;박덕희;김성남
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권6호
    • /
    • pp.296-302
    • /
    • 2001
  • This paper proposes a SSSC based on multi-bridge inverters. The dynamic characteristic of the proposed SSSC was analyzed by EMTP simulation and a scaled hardware model, assuming that the SSSC is inserted in the transmission line of the one-machine-infinite-bus power system. The proposed SSSC has 6 multi-bridge inverters per phase, which generates 13 pulses for each half period of power frequency. The proposed SSSC generates a quasi-sinusoidal output voltage by 90 degree phase shift to the line current. The proposed SSSC does not require the coupling transformer for voltage injection, and has a flexibility in operation voltage by increasing the number of series connection.

  • PDF

SMES 와 DVR을 이용한 전력계통품질 안정화 시스템 모델링 (Modeling of Power Quality Stabilization using SMES and DVR)

  • 박성열;정희열;김아롱;김재호;박민원;유인근;김석호;김해종;성기철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2251-2252
    • /
    • 2008
  • Recently, voltage sag from sudden increasing loads is also one of the major problems inside the utility network. In order to compensate the voltage sag problem, power compensation device systems could be a good solution method. In case of voltage sag, an energy source is needed to overcome the energy loss caused by the voltage sag. Superconducting Magnetic Energy Storage (SMES) is a very promising source of this energy due to its fast response of charging and discharging time. Before constructing the power electronic delivering system for the SMES, it is necessary to simulate the system to understand its behavior. Nowadays, a lot of devices have been developed to compensate voltage sag such as Dynamic Voltage Restorer (DVR), Distribution Static Compensator (D-STATCOM) and Uninterruptible Power Supply (UPS). In this paper, focus is given only on DVR system which will be simulated by using PSCAD/EMTDC software.

  • PDF

Matlab/Simulink를 이용한 무효전력 보상장치의 플리커 저감 효과 연구 (Comparative Simulation of flicker Mitigating Efficiencies of Various Compensating Devices using Matlab/Simulink)

  • 정재안;조수환;장길수;강문호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.83-84
    • /
    • 2008
  • Voltage fluctuation, also known as flicker, is a power quality problem caused by nonlinear loads like electric arc furnace. Since it is interpreted as a variation of the supplied electrical energy, it causes the residential customers to feel much annoyed visually through the lamps. Due to the statistical nature of IEC (International Electrotechnical Commission) short-term flicker severity index, Pst, it is not feasible to pre-evaluate the flicker level using the transient power system simulators such as Sim Power System in Matlab/Simulink. So this paper presents not only how to design the Matlab/Simulink IEC flickermeter to yield the Pst value, which considering electric distribution environments of South Korea, but also how to mitigate the voltage flicker at the Point of Common Coupling (PCC). In order to achieve this, the flicker mitigation efficiencies of various compensating devices, such as Static Var Compensator (SVC), STATCOM will be applied and compared. The simulated result demonstrates which compensating equipment is the most efficient method to mitigate the flicker phenomenon.

  • PDF

A Study on an Operation Strategy of Dual-Infeed HVDC System

  • Kim, Chan-Ki;Jang, Gilsoo
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.45-52
    • /
    • 2017
  • This paper deals with the operation strategy of reactive power in a multi-infeed HVDC (MIHVDC) system, in which several converters are connected to the same or nearby separate AC buses. The potential problems concerning a MIHVDC system when feeding a weak AC network are as follows: the need for coordination of the recovery control, the possibility of voltage instability or low quality of the area connected to the MIHVDC system, and the risk of mutual commutation failures. These problems in MIHVDC systems are similar to those in single-infeed HVDC (SIHVDC) systems, but the differences with the phenomenon of the SIHVDC system are the interactions between converters. The main reason for the potential problems of HVDC systems (MIHVDC or SIHVDC) is voltage variation; therefore, to mitigate the voltage variations, the performances of the HVDC system should be enhanced. Consequently, to mitigate the potential problems of MIHVDC systems, several solutions are suggested in this study, including installing STATCOM and installing a line arrester on the tower. The study results will be applied to a multi-infeed HVDC system in Korea.

계통연계형 풍력발전 시뮬레이터 개발 (Development of the Wind Power Simulator Connected to the Grid)

  • 최영도;전영수;전동훈;신정훈
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.542-545
    • /
    • 2009
  • 고창의 전력품질 실증시험장에서 계통에 연계된 풍력발전 시뮬레이터를 이용하여 풍력발전기의 특성을 파악하기 위해, 가변 풍속에서 이중여자 풍력발전기의 회전속도와 유효전력의 변화가 계통에 미치는 영향을 분석하였다. 고창의 전력품질 실증시험장은 22.9kV 계통에 전력품질 향상기기(DVR, STATCOM, SSTS)와 전력품질 외란 발생장치 등이 구축되어 있다. 모터와 VVVF를 이용하여 풍력발전기의 블레이드를 구현하고, 유도형과 이중여자 유도형 풍력발전기를 모의할 수 있는 시뮬레이터를 개발하였다. 선로의 길이를 20 kM로 가정하고, 덕적도의 풍속데이터를 이용한 가변풍속 패턴을 설정하여 풍력발전기의 회전속도에 대한 출력특성을 확인하였다.