• Title/Summary/Keyword: STATCOM power system

Search Result 147, Processing Time 0.026 seconds

Robust Stability Analysis of STATCOM System for Power Quality Enhancement (전력 품질 개선을 위한 STATCOM 시스템의 강인 안정도 해석)

  • Sung, Hwa-Chang;Park, Jin-Bae;Tak, Myung-Hwan;Joo, Young-Hoon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.2
    • /
    • pp.220-225
    • /
    • 2010
  • This paper deals with the robust stability analysis of STATCOM (Static Synchronous Compensator) power system for power quality enhancement and power system stability. The STATCOM plays an important role in controlling the reactive power flow to the power network and hence the system voltage fluctuations and stability. The control areas of this plant are very large and the overall composition of the system is nonlinear. Also, STATCOM is influence of the uncertainties so that it is necessary to apply the new control technique. For solving these problems, we perform the fuzzy modeling and robust analysis for STATCOM system.

Analysis of the Distribution STATCOM Operating Results for Improving Distribution System Power Quality (전력품질 향상을 위한 배전용 STATCOM 운전결과 분석)

  • 오관일;전영수;박상태;추진부
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.377-385
    • /
    • 2000
  • This paper presents the test and operation results of the domestic demonstration of the reactive power compensation device called STATCOM (STATic COMpensator). The object of the paper is to describe the reliability of the unit based on the extensive operation databases. The custom power is similar in nature to the concept of FACTS(Flexibel AC Transmission System). By controlling reactive power, the technology offers utilities the opportunity for increased efficiency and their capabilities will permit transmission planners make the best use of their existing transmission resources. STATCOM is a custom power device in a way and can be used in a similar way for the dynamic compensation of power transmission systems, providing reactive power compensation, voltage regulation and mitigation of voltage flicker. It is shown that the STATCOM has clear advantages in areas such as; providing reactive power compensation and improving power factor.

  • PDF

Study on the control coordination of STATCOM and Switched Shunt considering their dynamic characteristics in bulk power system (대규모 전력계통에서 STATCOM과 Switched Shunt의 동특성을 고려한 협조제어 검토)

  • Kook, Kyung-Soo;Oh, Tae-Kyoo;Lee, J.H.;Kim, Hak-Man
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.184-186
    • /
    • 2003
  • As STATCOM is considered to be installed in bulk power system, various studios are conducted to establish strategies for system operation considering STATCOM. This paper describes control strategy for coordinating STATCOM with existing switched shunt in bulk power system.

  • PDF

A Study on Local Coordinative Reactive Power Control between STATCOM and Other Reactive Power Controllers for Voltage Stability Improvement at Substation (변전소 전압안정화를 위한 STATCOM과 기존 조상 설비간의 지역 무효전력 협조제어에 관한 연구)

  • Jeong, Ki-Seok;Chang, Byun-Hoon;Lee, Hyun-Chul;Lee, Geun-Joon;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.525-530
    • /
    • 2010
  • Installation of FACTS(Flexible AC Transmission System) device can maximize utilization of existing power facilities and reliability of power system. STATCOM has excellent characteristics in operating cost, maintaining facilities, loss and so on. However, STATCOM has a disadvantage of facility cost over capacity. So it is effective to coordinate STATCOM and existing external bank(capacitor and reactor) and OLTC(On Load Tap Changer). This paper mainly proposes coordinative control method between STATCOM installed within substation and other reactive power resources including Shunt Reactors and Shunt Capacitors and OLTC for voltage stability improvement. The proposed coordinative control method is developed for the STATCOM of Mi-gum substation and the simulation results of EMTP/RV model show the effectiveness of the proposed method.

A Study on a New Power Flow Method for Analysis of AC Electric Railway System and Improvement of Voltage Drop Using a STATCOM (교류 전기철도 시스템의 해석에 적합한 조류계산 기법 및 STATCOM을 적용한 전압 강하 개선 연구)

  • Baek, Jung-Myoung;Lee, Byung-Ha
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.669-676
    • /
    • 2007
  • This paper presents a new power flow method to analyze the AC electric railway system effectively in both cases of traction and regenerative braking of the trains. The algorithm to easily solve the power flow of the AC electric railway system with the trains of regenerative braking from the system without a train of regenerative braking is derived. Using this new power flow method, the voltage characteristics of a typical AC electric railway system is easily analyzed in both cases of traction and regenerative braking of the trains. We show that the presented method can be applied effectively in order to analyze the AT-fed AC electric railway system in both cases of traction and regenerative braking of the trains. A STATCOM(Static Synchronous Compensator) is applied to the system in order to improve the voltage drop problem and this case is also analyzed to show the effect of STATCOM.

Improvement of Power Quality in DC Traction Systems Using Statcom

  • Hosseini, Seyed Hossein;Sarhangzadeh, Mitra;Ajami, Ali
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.164-168
    • /
    • 2005
  • In this paper a statcom is developed to improve the power quality in a dc traction system. The proposed statcom can be used as both inverter and active filter. As an active filter, it can compensate harmonic distortion and reactive power and as an inverter, it can recycle regenerative energy caused by decelerating trains. The simulation results are carried out by using PSCAD/EMTDC software.

  • PDF

Combined Design of PSS and STATCOM Controllers for Power System Stability Enhancement

  • Rohani, Ahmad;Tirtashi, M. Reza Safari;Noroozian, Reza
    • Journal of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.734-742
    • /
    • 2011
  • In this paper a robust method is presented for the combined design of STATCOM and Power System Stabilizer (PSS) controllers in order to enhance the damping of the low frequency oscillations in power systems. The combined design problems among PSS and STATCOM internal ac and dc voltage controllers has been taken into consideration. The equations that describe the proposed system have been linearized and a Fuzzy Logic Controller (FLC) has been designed for the PSS. Then, the Particle Swarm Optimization technique (PSO) which has a strong ability to find the most optimistic results is employed to search for the optimal STATCOM controller parameters. The proposed controllers are evaluated on a single machine infinite bus power system with the STATCOM installed in the midpoint of the transmission line. The results analysis reveals that the combined design has an excellent capability in damping a power system's low frequency oscillations, and that it greatly enhances the dynamic stability of power systems. Moreover, a system performance analysis under different operating conditions and some performance indices studies show the effectiveness of the combined design.

Characteristic Analysis of Voltage Stability Improvement and Power Factor Correction by STATCOM (STATCOM의 전압안정도개선 및 역률 보상 특성분석)

  • Park, Ji-Yong;Park, Duk-Hee;Han, Byung-Moon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.12
    • /
    • pp.1507-1513
    • /
    • 1999
  • This paper describes simulation and experimental results to analyze the dynamic characteristics of STATCOM, which is connected to the ac system for compensation the power factor and improving the voltage stability. The simulation and experimental results confirm that the scaled model for STATCOM can properly compesate the power factor of the load and regulate the bus voltage at the common connection point.

  • PDF

SVC and Stacom Characteristics for Voltage Stability in Jeju Power System (제주계통 전압 안정성을 위한 SVC 및 Statcom 동작특성 비교)

  • Lee, DoHeon;Lee, Seung Min;Kim, Ho-Min;Kim, Eel-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.548-549
    • /
    • 2014
  • In Jeju power sytstem, the generation of reactive power depends on the operation of CSC-HVDC filter. Thus, the grid voltage will be affected. Statcom and SVC have demonstrated that it has excellent charateristics to solve this problem. First, this paper analyzes the operation of the Statcom based on the real power system in Jeju. Then, the characteristics of Statcom will be compared to the SVC. The modelling of the Jeju power system including Statcom and SVC will be performed by using PSCAD/EMTDC program and the real data from the real Jeju power system.

  • PDF

Coordination Control of Voltage Between STATCOM and Reactive Power Compensation Devices in Steady-State

  • Park, Ji-Ho;Baek, Young-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.5
    • /
    • pp.689-697
    • /
    • 2012
  • This paper proposes a new coordinated voltage control scheme between STATCOM (Static Synchronous Compensator) and reactive power compensation devices, such as shunt elements(shunt capacitor and shunt reactor) and ULTC(Under-Load Tap Changer) transformer in a local substation. If STATCOM and reactive power compensators are cooperatively used with well designed control algorithm, the target of the voltage control can be achieved in a suddenly changed power system. Also, keeping reactive power reserve in a STATCOM during steady-state operation is always needed to provide reactive power requirements during emergencies. This paper describes the coordinative voltage control method to keep or control the voltage of power system in an allowable range of steady-state and securing method of momentary reactive power reserve using PSS/E with Python. In the proposed method of this paper, the voltage reference of STATCOM is adjusted to keep the voltage of the most sensitive bus to the change of loads and other reactive power compensators also are settled to supply the reactive power shortage in out range of STATCOM to cope with the change of loads. As the result of simulation, it is possible to keep the load bus voltage in limited range and secure the momentary reactive power reserve in spite of broad load range condition.