• Title/Summary/Keyword: STAMP

Search Result 448, Processing Time 0.028 seconds

A Study on the Design of Synchronization Protocol for Multimedia Communication (멀티미디어 통신을 위한 동기 프로토콜의 설계에 관한 연구)

  • 우희곤;김대영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.8
    • /
    • pp.1612-1627
    • /
    • 1994
  • There is a synchronization function which deals with only single media of text in the OSI Session Layer. So new synchronization schem and synchronization protocol are required for multimedia communications which include audio, video and graphic as well as text information. In this paper, conceptional Multmedia Synchronization Layer(MS layer) environment is composed and its service primitives and protocols based on 'multi-channel, base media scheme' are designed and proposed for multimedia synchronization services. This MS layer Manager (MSM) establishes the MS layer connection to the peer MS layer and manages each media channel which is created in MS layer media by media. The MSM also finds the synch-position through the media frame number by utilizing it like the time stamp to provide inter-media synchronization services as well as intra-media synchronization services.

  • PDF

PDMS Stamp Fabrication for Photonic Crystal Waveguides (광자결정 도파로 성형용 PDMS 스탬프 제작)

  • Oh, Seung-Hun;Choi, Du-Seon;Kim, Chang-Seok;Jeong, Myung-Yung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.4 s.193
    • /
    • pp.153-158
    • /
    • 2007
  • Recently nano imprint lithography to fabricate photonic crystal on polymer is preferred because of its simplicity and short process time and ease of precise manufacturing. But, the technique requires the precise mold as an imprinting tool for good replication. These molds are made of the silicon, nickel and quartz. But this is not desirable due to complex fabrication process, high cost. So, we describe a simple, precise and low cost method of fabricating PDMS stamp to make the photonic crystals. In order to fabricate the PDMS mold, we make the original pattern with designed hole array by finding the optimal electron beam writing condition. And then, we have tried to fabricate PDMS mold by the replica molding with ultrasonic vibration and pressure system. We have used the cleaning process to solve the detaching problem on the interface. Using these methods, we acquired the PDMS mold for photonic crystals with characteristics of a good replication. And the accuracy of replication shows below 1% in 440nm at diameter and in 610nm at lattice constant by dimensional analysis by SEM and AFM.

Update Thresholds of More Accurate Time Stamp for Event Reconstruction (이벤트 재구성을 위한 타임스탬프 갱신 임계치)

  • James, Joshua I.;Jang, Yunsik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.2
    • /
    • pp.7-13
    • /
    • 2017
  • Many systems rely on reliable timestamps to determine the time of a particular action or event. This is especially true in digital investigations where investigators are attempting to determine when a suspect actually committed an action. The challenge, however, is that objects are not updated at the exact moment that an event occurs, but within some time-span after the actual event. In this work we define a simple model of digital systems with objects that have associated timestamps. The model is used to predict object update patterns for objects with associated timestamps, and make predictions about these update time-spans. Through empirical studies of digital systems, we show that timestamp update patterns are not instantaneous. We then provide a method for calculating the distribution of timestamp updates on a particular system to determine more accurate action instance times.

DSSCs Efficiencies of Photo Electrode Thickness and Modified Photo Electrode Surface Area (광전극 두께와 표면적 변형에 따른 DSSC의 효율 특성)

  • Kwon, Sung-Yeol;Yang, Wook;Zhou, Ze-Yuan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.2
    • /
    • pp.115-120
    • /
    • 2014
  • Photo electrode is an important component for DSSC. DSSCs electrical characteristics and efficiencies fabricated with different $TiO_2$ photo electrodes thickness and modified phoro electrode surface area were studied. $11{\mu}m$ $TiO_2$ photo electrode shows a 4.956% efficiency. The highest short circuit current density was a $9.949mA/cm^2$. Efficiencies and short circuit current density increased as tape casting thickness decreased. Modified surface area of the photo electrode by needle stamp processing were studied. 200 times needle stamp processing on photo electrodes shows a highest 5.168% efficiency. Also the short circuit current density was a $10.261mA/cm^2$.

High density line patterns fabricated by thermal imprint (Thermal imprint를 이용한 고밀도 line패턴 형성방법)

  • Lee, Sang-Moon;Kwak, Jung-Bok;Lee, Hwan-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.270-270
    • /
    • 2008
  • We present details of experimental results in the fabrication of high density line patterns, using imprint technique that can provide a simple and comparatively cost-effective manufacturing means. Barrier array structures for display or interconnects for semiconductor applications were the aims of this study. For pattern fabrication, a polymer layer (Ajinomoto GX-13 dielectric film) with a thickness of 38um that can act as either an insulating or a dielectric layer was laminated on a substrate. Fine tracks were then formed using a patterned stamp under isostatic pressure. The line width was ranged between 10 to 60 mm. A self-assembled monolayer (SAM) of fluorinated alkylchlorosilane [$CF_3(CF_2)5(CH_2)2SiCl_3$] as an anti-sticking layer was coated on the surface of the stamp prior to thermal imprint to improve the de-molding characteristic.

  • PDF

A Preliminary Study on Tantalum Recycling from Obsolete Condenser by Multidisciplinary Process (융복합기술(融複合技術)에 의한 폐(廢)콘덴서로부터 탄탈륨 재활용(再活用) 기초연구(基礎硏究))

  • Lee, Hoo-In;Kim, Sang-Bae;Kim, Byong-Gon;Choi, Young-Yoon
    • Resources Recycling
    • /
    • v.16 no.6
    • /
    • pp.34-38
    • /
    • 2007
  • For recycling of tantalum from obsolete condenser, physical separations and chlorination of tantalum scraps with $Cl_2$ and $CCl_4$ were investigated. The recovery ratio of tantalum from obsolete condenser was 98% by using a multidisciplinary process of crushing by stamp mill, wet gravity separation by the shaking table, and air classification. In the chlorination reaction of non-oxidized Ta anode with $Cl_2$, the highest weight loss ratio is at least 60%, while in the chlorination reaction of Ta anode with $CCl_4$, the reaction rate for the oxidized Ta anode is faster than that of the non-oxidized Ta anode.

Time Stamp Compression in RTP Protocols using Enhanced Negotiation Bits Decision Algorithm (RTP 프로토콜에서 Time Stamp필드의 압축을 위한 향상된 협상비트 결정 알고리즘)

  • Kim, Kyung-Shin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.10
    • /
    • pp.55-61
    • /
    • 2013
  • The important issue in header compression would be how to compress the dynamic field increasing constantly between consecutive packets in the head of IP wireless networks. Existent header compression scheme that can eliminated repeated field in header are RFC2507, RFC3095 and E-ROHC scheme. In this paper, I propose a new method of compressing TS fields, which are the Dynamic fields of the RTP packet, into BCB (Basic Compression Bits) basic bits or NCB (Negotiation Compression Bits, BCB + additional bits) bits. In order to verify the proposed header compression method, I have simulation about proposed video packets of IP wireless networks. using Visual SLAM.

Fabrication and evaluation of label-free protein sensor for diagnosing acute myocardial infarction (급성 심근경색 검지를 위한 비표지식 단백질 센서 제작 및 검증에 관한 연구)

  • Cho, Younggeol;Kang, Ki-Won;Kim, Hyo-Kyum;Cho, Eikhyun;Kang, Shinill
    • Transactions of the Society of Information Storage Systems
    • /
    • v.9 no.1
    • /
    • pp.28-31
    • /
    • 2013
  • We proposed a method to fabricate label-free protein sensor with sub-wavelength nanograting structures to be used for diagnosing acute myocardial infarction. A nickel stamp for the injection molding of nanograting integrated protein sensor was fabricated by electroforming process with high fidelity. By using metallic stamp, we replicated label-free protein sensor via injection molding, which is an outstanding method for low-cost and mass production of polymer products. Finally, we performed a feasibility test, examining cardiac troponin T (cTnT) and anti-cTnT interactions. From the results, we demonstrated that the fabricated protein sensor can provide information for the early and accurate detection of cardiac diseases such as acute myocardial infarction.

A Study on Manufacturing of LCD Prism Sheets Through Silicon Anisotropic Etching (실리콘 이방성 식각을 통한 LCD 프리즘 시트 제작 연구)

  • Jeon, Kwangseok;Ryoo, Kunkul
    • Korean Journal of Metals and Materials
    • /
    • v.46 no.6
    • /
    • pp.377-381
    • /
    • 2008
  • Prism sheet of LCD BLU which depends on supply from Japan and U.S.A was studied by using Si anisotropic etching and injection molding technologies. First, the prism sheet was patterned on Si wafer through photolithography, and the best conditions of Si etching were determined through etching Si wafer with TMAH to obtain straight optimized zigzag patterns, and a cross pattern to provide light diffusion and concurrent focusing. The etch rate of TMAH was concluded to be constant for $25wt%-70^{\circ}C$ condition. Ni stamp of prism sheet was made by electrodeposition using patterned Si wafer, normal or fast H/C(Heating/Cooling) injections were carried out to fabricate prism sheet. It was known that fast H/C injection could fabricate prism sheet more accurately than normal injection. Zigzag patterns and the cross pattern showed higher transmissivity than the straight patterns because of light diffusion through diagonal direction. The fast H/C injection for zigzag patterns showed lower transmissivity than normal injection because there occurred more light diffusion through precise injection patterns, but the fast H/C injection for straight patterns showed only refraction without diffusion, causing lower transmissivity than normal injection.

Nutrition Evaluation Screening Tool: An Easy to Use Screening Tool for Hospitalised Children

  • Dokal, Kitt;Asmar, Nadia;Shergill-Bonner, Rita;Mutalib, Mohamed
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.24 no.1
    • /
    • pp.90-99
    • /
    • 2021
  • Purpose: Nutrition screening is vital to ensure patients are appropriately managed in hospital. In paediatrics there is currently no universally accepted nutrition screening tool. The Nutrition Evaluation Screening Tool (NEST) was developed as an easy to use and practical screening tool for hospitalised children. We aim to evaluate compliance of the NEST and assess agreement of the NEST with the already validated nutrition screening tools, Screening Tool for Risk on Nutritional Status and Growth (STRONGkids), Screening Tool for the Assessment of Malnutrition in Paediatrics (STAMP) and the Subjective Global Nutritional Assessment (SGNA) tool. Methods: Retrospective review of 102 patient episodes at the Evelina London Children's Hospital. Electronic records were used to assess NEST compliance and to complete the nutrition tools for each patient episode. Cohen's kappa was used to determine the level of agreement between each nutrition tool. Results: There was moderate agreement between the NEST and the two screening tools, STRONGkids (κ=0.472) and STAMP (κ=0.416) for patients on initial screening at admission. 87.2% of patient episodes were NEST compliant within 24 hours of admission to hospital. Conclusion: The moderate agreement between these two already validated screening tools enhances the NEST's validity as a paediatric screening tool. The NEST had the strongest correlation with the SGNA tool compared to other screening tools. The NEST is user friendly screening tool for hospitalised children.