• 제목/요약/키워드: SS concentration

검색결과 670건 처리시간 0.032초

신규 플루오로퀴놀론계 DWP20367의 흰쥐 및 개에서의 체내동태와 조직분포 (Pharmacokinetics and Tissue Distribution of DWP20367, a Novel Fluoroquinoloce, in Rats and Beagle Dogs)

  • 조재열;한승희;김병오;남권호;손호정;유영효;정대영
    • Biomolecules & Therapeutics
    • /
    • 제5권3호
    • /
    • pp.284-291
    • /
    • 1997
  • The pharmacokinetics and tissue distribution of DWP20367 (1-cyclopropyl-6-fluoro-8-chloro-7-(2, 7-diazabicyclo[3,3,0]tract-4-ene-7-yl)-1,4-dihydro-4-oxoquinoline-3-carboxylic acid), a novel fluoroquinolone, were examined in rats and beagle dogs after a single intravenous and oral administration. Analysis of DWP20367 in plasma, tissue, and urine was determined by both HPLC and microbiological assay (bioassay). The plasma concentration-time curves of the drug in rats and beagle dogs were biexponentially declined. The terminal half-life (t$_{1}$2$\beta$/) of the drug in rats was about 60.1 $\pm$7.3 min (i.v.) and 61.3 $\pm$ 12.4 min (p.o.) in bioassay, and 86.3 $\pm$19.8 min (i.v.) and 50.9$\pm$ 14.9 min (p.o.) in HPLC. In beagle dogs, half-life of the drug determined by bioassay was about 121.8$\pm$6.2 min (i.v.) and 111.0$\pm$7.6 min (p.o.). The volume of distribution at steady-state (Vd$_{ss}$ ) was 243.8$\pm$74.1 ml/kg (bioassay) and 339.2$\pm$84.3 ml/kg (HPLC) in rats, and 1587.5 $\pm$536.9 ml/kg (bioassay) in beagle dogs. The total body clearance (Cl$_{t}$) of DWP20367 was 3.4 $\pm$ 0.4 ml/min/kg (bioassay) and 2.4$\pm$0.4 ml/min/kg (HPLC) in rats, and 12.3$\pm$ 1.0 ml/min/kg (bioassay) in beagle dogs, respectively. The extent of bioavailability after oral administration was 89.1%(bioassay) and 79.9% (HPLC) in rats, and 78.7% (bioassay) in beagle dogs. Urinary recovery (24-h) assayed by bioassay was 0.7% (p.o.) and 1.2% (i.v.) in rats, and 0.8% (p.o.) and 1.0% (i.v.) in beagle dogs. In rats, 24-h fecal recovery determined by bioassay was 11.2% (p.o.) and 0.1% (i.v.). Rat and human serum protein binding ratios at 2$\mu$g/ml were about 90~91%. This drug determined by bioassay was also distributed by the order of liver, kidney, lung, heart, spleen and muscle 30 min after oral administration.on.

  • PDF

하천 생물 서식처 평가를 위한 하천 자연도와 수질의 상관성 분석 (A Correlation Analysis of the River Naturalness and Water Quality for Biological Habitat Evaluation)

  • 박봉진;성영두;정관수
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.386-390
    • /
    • 2006
  • 금번 연구에서는 낙동강 유역내 주요하천을 대상으로 자연도 평가와 수질을 분석하였다. 하천 자연도의 종합평가 결과는 $1.428{\sim}4.107$의 1등급과 4등급으로 평가 되었으며, 부문별 평가 결과는 하천형태의 평가지수가 $2.111{\sim}4.048$으로 2등급에서 4등급으로, 하천환경의 평가지수는 $1.774{\sim}3.643$의 1등급에서 4등급으로 평가되었다. 수질 평가 결과는 수소이온농도는 $7.102{\sim}8.497mg/{\ell}$이었으며, 생물화학적 산소요구량은 $0.748{\sim}5.271mg/{\ell}$, 용존산소량 $3.668{\sim}19,960mg/{\ell}$, 부유물질은 $5.077{\sim}12.335mg/{\ell}$이었다. 하천 자연도 평가 지표의 독립성과 유사성을 판단하기 위하여 하천 자연도 평가와 수질 상관분석을 실시한 결과, 상관계수가 $-0.1503{\sim}-0.5886$로 낮은 상관성을 갖고 있으며, 서로 독립적인 지표인 것으로 분석되었다.

  • PDF

회전원판법을 적용한 Modified Dephanox 공정의 하수처리특성 (Characteristics of Wastewater Treatment in Applying RBC Modified Dephanox Process)

  • 강민구;김금용;류홍덕;이상일
    • 대한환경공학회지
    • /
    • 제32권5호
    • /
    • pp.477-486
    • /
    • 2010
  • 본 연구는 생물학적 폐수처리공정의 하나인 회전원판법(RBC)을 이용하여 질산화 반응을 향상 시키는 목적으로 수행되었다. 그 일환으로 회전원판법(RBC)에 의한 질산화반응의 향상을 평가하기 위해서 본 연구에서는 Modified Dephanox 공정에 회전원판법(RBC)를 적용하여 연구를 수행 하였다. 회전원판법(RBC)을 이용한 공정의 가장 두드러진 특징은 질산화 반응조 안으로 질산화반응에 방해인자로 작용하는 고농도의 부유성 고형물(suspended solid)이 유입되어도 질산화반응을 원활히 수행할 수 있다는 데 있다. 게다가 공정의 운영결과 TCOD 제거 효율은 유입 TCOD 부하율이 0.04~0.1 kg/$day{\cdot}m^3$ 일 때는 약 90%이상의 TCOD 제거효율이 나타났다. T-N 제거효율은 약 75% 정도로 실험실규모의 공정운영에도 불구하고 높은 제거효율이 관찰되었다. 또한 인 의 경우 ${PO_4}^{3-}$-P 및 T-P 제거효율은 유입 ${PO_4}^{3-}$-P 및 T-P 부하율이 증가할수록 제거효율은 증가하는 경향을 나타내고 있다. 결론적으로 Modified Dephanox 공정에서 독립질산화 반응을 수행하는 회전원판법(RBC)의 이용은 높은 질산화반응을 수행할 뿐만 아니라 유입되는 부유성 고형물(suspended solid)의 영향을 최소화하여 안정적인 처리효율을 나타내는 시스템이다.

버블의 크기별 입도분포와 부상시간과의 상관특성에 관한 연구 (A Study on the Relation Characteristics between Bubble Size Distribution and Floating Time)

  • 전건;박철휘
    • 대한환경공학회지
    • /
    • 제39권5호
    • /
    • pp.277-281
    • /
    • 2017
  • 최근 강우는 짧은 시간에 많은 비가 오는 특성을 자주 나타낸다. 이런 기상현상 때문에, 초기유출수와 합류식하수관거 월류수의 유입유량과 농도도 변화되고 있다. 이와 같이 유입조건이 변동되는 경우에는, 높은 수면적부하율을 가지는 부상방법이 공공수역의 수질관리에 적합하다. 왜냐하면 부상법은 공공수계의 요구조건을 충족 할 수 있기 때문이다. 현재까지 이러한 부상법의 검증과 진단을 위하여, 공급공기량과 유입SS량의 비율을 반영하여 왔다. 그러나 불행하게도 이러한 방식은 기술진단과 검증을 위한 판단기준으로는 그 한계를 가진다. 왜냐하면 부상속도와 시간요소가 상이한 버블분포에 의해 달라지기 때문이다. 부상속도와 시간은 처리시설의 용량에 영향을 준다. 왜냐하면 시간인자가 시설의 규모를 결정하기 때문이다. 그러므로, 동일한 공급공기량과 유입SS농도간 비율조건에서의 버블분포특성과 부상시간특성을 운영 및 기술진단 및 평가를 위한 판단기준으로 적용하여야만 한다. 따라서 이러한 필요에 따라, 이 논문 내용은 버블분포와 부상시간간 관계의 분석에 대한 실증적 일반화에 관한 연구이다.

DOF 공정에 의한 정수처리 효과 (Effect of Drinking Water Treatment by DOF(Dissolved Ozone Flotation) System)

  • 이병호;송원철
    • 대한환경공학회지
    • /
    • 제30권7호
    • /
    • pp.743-750
    • /
    • 2008
  • 본 연구에서는 용존오존부상법(Dissolved Ozone Flotation; DOF)을 이용한 정수처리 효과를 파악하기 위하여 적정 오존 주입 농도와 오존 주입 농도별 처리 특성에 대해서 연구하였으며, 또한 용존공기부상법(Dissolved Air Flotation; DAF) 및 중력식 침전법(Conventional Gravity Sedimentation; CGS)과 DOF의 처리 성능을 비교하였다. 최적 오존 주입 농도를 산정하기 위한 실험에서 최적 오존 주입농도는 2.7 mg/L로 나타났으며, 오존 주입 농도가 증가할수록 탁도 및 KMnO$_4$ 소모량, UV$_{254}$ 흡수도, TOC 등과 같은 제거효율이 낮아지는 것으로 나타났다. DOF와 DAF, CGS의 처리성능을 비교한 결과 오존 주입 농도 2.7 mg/L로 운전한 DOF시스템의 탁도 제거효율은 88.9%, 유기물질 항목의 경우 KMnO$_4$ 소모량은 62.9%, TOC 47%, 그리고 UV$_{254}$ 흡수도 77.3% 그리고 THMFP 제거율의 경우 51.6%로 다른 두 공정보다 높거나 비슷하게 나타났다. 따라서 응집 부상 공정과 오존 산화 공정이 하나의 반응기에서 일어나는 DOF 시스템은 정수처리시설의 소유부지 감소와 기존 CGS 시스템에서 처리가 어려운 조류 및 용존성 유기물질의 제거를 통해 소독부산물의 생성을 감소시킴으로 향후 고도정수처리시스템으로 적용 가능성이 충분한 것으로 판단된다.

하천수 (반월천, 동화천, 삼화천)의 시화인공습지 관류에 따른 개방수에서 식물플랑크톤 군집 동태 (Dynamics of Phytoplankton Community in the Open Water Flowed Through the Shihwa Constructed Wetland from Streams (Banwoul, Donghwa and Samhwa stream))

  • 김용재
    • 생태와환경
    • /
    • 제38권3호통권113호
    • /
    • pp.403-411
    • /
    • 2005
  • 인공습지를 이용한 오염수 처리를 위해 조성된 시화 인공습지의 개방수 정점에서 식물플랑크톤과 갈대 조성지의 정점에서 갈대 부착 조류 군집의 동태에 대한 연구를 위해 5개의 정점을 선정하여 2001년 10월부터 2002년 6월까지 조사를 실시하였다. 반월천으로부터 유입된 오염수는 정점 1을 통해 갈대군락을 관류하면서 정점 2에서 저감 효과를 나타내었다. 총인/총질소 비는 모든 정점에서 16 이상을 약간 상회하였다. 본 수계는 인이 제한 영양염으로 작용하는 것으로 나타났다. 식물플랑크톤은 총 413종류로서 375종, 21변종, 2품종 및 15미동정이었다. 현존량은 330 ${\sim}$ 36,420 cells $mL^{-1}$의 범위로 정점 5에서 최저였고 정점 1에서 최대였다. 현존량은 정점 1과 2, 정점 3과 4를 관류하면서 영양염류와 같이 감소되는 경향을 나타내었다. 엽록소 농도는 $2.5\;{\sim}\;170.7\;{\mu}g\;L^{-1}$의 범위로 정점 1에서 최대였고 정점 5에서 최저였다. 엽록소 농도 역시 유입수부터 습지 관류후의 정점에서 뚜렷한 차이를 나타내었다. 우점종은 Euglena oblonga, Synura spinosa 등 14종류였으며 정점 1과 2에서는 부영양수역에서 출현율이 높은 종으로 조성되어 있다. 하천수가 유입되는 개방수역과 인공습지를 관류한 이후의 개방수역의 식물플랑크톤 군집은 뚜렷한 차이를 나타내었다. 이것은 습지를 관류하면서 물리화학적 환경변화에 따른 영향으로 사료된다.

질산화균 활성화조를 이용한 하수처리 공정에서의 유기물 및 질소, 인 제거에 관한 연구 (A Study on Removal of Organism and Nitrogen, Phosphorus in Wastewater Treatment Process Using Nitrifier Activated Reactor)

  • 동영탁;서동환;배유진;박주석
    • 상하수도학회지
    • /
    • 제21권6호
    • /
    • pp.727-735
    • /
    • 2007
  • The use of water by cities is increasing owing to industrialization, the concentration of population, and the enhancement of the standard of living. Accordingly, the amount of waste water is also increasing, and the degree of pollution of the water system is rising. In order to solve this problem, it is necessary to remove organisms and suspended particles as well as the products of eutrophication such as nitrates and phosphates. This study developed a high-end treatment engineering solution with maximum efficiency and lower costs by researching and developing a advanced treatment engineering solution with the use of Biosorption. As a result, the study conducted a test with a $50m^3/day$ Pilot Scale Plant by developing treatment engineering so that only the secondary treatment satisfies the standard of water quality and which provided optimal treatment efficiency along with convenient maintenance and management. The removal of organisms, which has to be pursued first for realizing nitrification during the test period, was made in such a way that there would be no oxidation by microorganisms in the reactor while preparing oxygen as an inhibitor for the growth of microorganism in the course of moving toward the primary settling pond. The study introduced microorganisms in the endogeneous respiration stage to perform adhesion, absorption, and filtering by bringing them into contact with the inflowing water with the use of a sludge returning from the secondary settling pond. Also a test was conducted to determine how effective the microorganisms are as an inner source of carbon. The HRT(Hydraulic Retention Time) in the nitrification tank (aerobic tank) could be reduced to two hours or below, and the stable treatment efficiency of the process using the organisms absorbed in the NAR reactor as a source of carbon could be proven. Also, given that the anaerobic condition of the pre-treatment tank becomes basic in the area of phosphate discharge, it was found that there was excellent efficiency for the removal of phosphate when the pre-treatment tank induced the discharge of phosphate and the polishing reactor induced the uptake of phosphate. The removal efficiency was shown to be about 94.4% for $BOD_5$. 90.7% for $COD_{Cr}$ 84.3% for $COD_{Mn}$, 96.0% for SS, 77.3% for TN, and 96.0% for TP.

낙동강 소수계별 유달부하량 산정 및 평가 (Computation and Assessment of Delivery Pollutant Loads for the Streams in the Nakdong River Basin)

  • 윤영삼;유재정;김문수;이혜진
    • 한국물환경학회지
    • /
    • 제22권2호
    • /
    • pp.277-287
    • /
    • 2006
  • Production loads of the contaminants near the Nakdong-river are, BOD : $1,006ton{\cdot}day^{-1}$, TN : $117ton{\cdot}day^{-1}$, and TP : $21ton{\cdot}day^{-1}$. Among the sources of contamination, the biggest contribution to the production load was shared by the human population, which maintains 40.7% of BOD, 44.2% of TN, and 52.5% of TP production. Similarly, among the sources of discharge load, the human population contributed 45.0% of BOD, 34.5% of TN, and 45.8% of TP. Results of flow investigation in 2001 and 2002 indicate that among the side streams, Nam-river showed the greatest average flow. In case of main stream flow, it was increased in the downstream due to the increase of the influents from the side streams. In case of BOD, COD, TOC and SS, high values were detected at Keumho-river where industrial wastewater was discharged as high level concentration. In case of the main stream, Koryoung point where direct influence of Keumho-river and Seongseo industrial complex is evident showed high BOD, COD and TOC. Oxidized nitrogen compounds and total nitrogen showed similar patterns of BOD, COD, and TOC. Especially, nitrate nitrogen was relatively high at all points. However, in case of Chlorophyll-a, relatively high values were observed at mid- and downstream areas such as Koryoung, Namjee, Soosan, Moolkeum and Hakooeun. This could be caused by the slow flow rate and the abundant nutrient salts attributed by the side streams. Relatively better water quality was observed in 2002 when the flow was relatively abundant than that in 2001. Results of investigation during 2001-2002 showed that delivery load increased as the flow reaches downstream. In 2001, delivery loads at the downstream Soosan-bridge were BOD $22,152ton{\cdot}day^{-1}$, COD $45,467ton{\cdot}day^{-1}$, TN $22,062ton{\cdot}day^{-1}$, TP $926ton{\cdot}day^{-1}$. Delivery loads in 2002 were increased due to the increase of the rainfall. They are BOD $25,876ton{\cdot}day^{-1}$, COD $64,200ton{\cdot}day^{-1}$, TN $41,101ton{\cdot}day^{-1}$, and TP $1,362ton{\cdot}day^{-1}$.

틸리피아에서 분리(分離)한 Edwardsie tarda의 성상(性狀)과 항원성(抗原性)에 대하여 (Characteristics and Antigenicity of Edwardsiella tarda Isolated from Tilapia (Oreochramis niloticus))

  • 오명주;전세규
    • 한국어병학회지
    • /
    • 제1권2호
    • /
    • pp.77-85
    • /
    • 1988
  • 1987년(年) 3(월)月 부산수산대학(釜山水産大學) 어병학(魚病學) 실험실(實驗室)에서 사육중(飼育中)이던 틸라피아 (Oreochromis niloticus)에 세균성(細菌性) 질병(疾病)이 발생(發生)하여 만성적(慢性的)으로 몇마리씩 폐사(斃死)하였다. 본(本) 연구(硏究)는 이러한 질병(疾病)의 원인(原因)을 밝히기 위하여 원인균(原因菌)을 분리(分離)하였으며, 형태적(型態的), 생화학적(生化學的) 성상(性狀)을 관찰(觀察)하고 병원성(病原性), 약제감수성(藥劑感受性) 실험(實驗)을 하였으며 시험항원(試驗抗原)을 제작(制作)하여 그 항원성(抗原性)을 조사하였는바, 그 결과(結果)를 요약(要約)하면 다음과 같다. 1. 병어(病魚)에서 분리(分離)된 원인균(原因菌)은 Edwardsiella tarda로 동정(同定)되었다. 2. 분리균(分離菌)을 틸라피아에 접종하여 재현성실험(再現性實驗)을 한 결과(結果) 전형적인 E. tarda의 감염증상을 나타내고 사망(死亡)했으며, 어류(魚類)로부터 동일균(同一菌)을 얻을 수 있었다. 3. 분리균(分離菌)은 oxytetracycline에서 감수성(感受性)이 높았고, MIC는 6.9로 나타났다. 4. 분리균(分離菌)은 병원성(病原性)이 강한 균(菌)이었으며, 48-LD50은 $10^{6.4}cell$/fish 이었다. 5. 시험항균(試驗抗原)으로, 포르말린사균항원, 초음파처리항원, 균여과액항원을 사용하였으며, 이 세가지를 사용한 항원성시험(抗原性試驗) 결과 포르말린사균항원의 시험구에서 높은 응집가와 방어력을 나타내었다.

  • PDF

시화호 및 주변해역의 수질 특성 (Characteristics of Water Quality In the Shihwa Lake and Outer Sea)

  • 장정익;한인섭;김경태;나공태
    • 해양환경안전학회지
    • /
    • 제17권2호
    • /
    • pp.105-121
    • /
    • 2011
  • 본 연구에서는 시화호의 수질 관리 정책 연구를 위한 최근의 수질 자료 확보를 목적으로 2010년에 시화호 내 외측 해역에서 수질 조사를 수행하였다. 시화호 표층수 수질항목들의 수평적 농도분포는 하천을 통한 담수 유업과 배수갑문을 통한 외해수 유입의 영향으로 인하여 반윌 및 시화 산단 얀근 상류지역에서는 높고 배수갑문으로 갈수록 낮아지는 경향을 나타냈다. 시화호 외해에서는 TN 및 TP가 소래포구에 가까운 곳에서 높은 농도를 나타내었으며, 전체적으로 시화호 내해보다는 상대적으로 낮은 농도를 나타내었다. 시화호 내측의 경우, 여름철 성층 형성 및 저층의 활발한 유기물 분해로 빈산소층이 발달되고 있었다. 수질항목들의 수직적 농도분포의 경우, 용존영양염, TN 및 TP는 표층보다 저층에서 높았지만, COD, 클로로필-a 및 POC는 이와 반대로 저층보다 표층에서 높은 분포를 나타냈다. 시화호 표층수에서 염분은 용존영양염과 양호한 음의 상관성을 보여 담수 기원의 영양염 공급이 확인되었고, 이에 의한 식물플랑크톤의 대증식으로 COD 및 POC가 높게 나타났다.