• Title/Summary/Keyword: SS농도

Search Result 525, Processing Time 0.024 seconds

Effects of the Co-treatment of Municipal Wastewater with Microwave-Irradiated Excess Sludge on the Performance of the Activated Sludge Process (초단파조사 처리된 잉여슬러지와 하수의 병합처리가 활성슬러지공법의 성능에 미치는 영향)

  • Kim, Nam-Chul;Jang, Myung-Bae;Cho, Yun-Kyung;Cho, Kwang-Myeung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.304-310
    • /
    • 2007
  • The purpose of this research was to investigate the effects of the co-treatment of municipal wastewater with microwave-irradiated excess sludge on the treatment efficiency and excess sludge production of the activated sludge process. When 250 mL of excess sludge with a MLSS concentration of approximately 2,000 mg/L was microwave-irradiated at $20^{\circ}C$ for $40\sim300$ sec by a microwave oven (2,450 MHz, 700 W), the temperature of the sludge increased at a rate of approximately $20^{\circ}C/min$ and the SCOD, TKN and T-P concentrations of the sludge showed the highest increase in the irradiation time of $40\sim130$ sec. And, the oxygen uptake rate measurement of the sludge microorganism suggested most of the microorganisms in the sludge were destroyed at an irradiation time above 130 sec(above $65^{\circ}C$). When the municipal wastewater and microwave-irradiated excess sludge was co-treated by the activated sludge process, almost no effect was observed in the pH and alkalinity of both the influent and effluent, but the influent concentrations of SS, COD, T-N and T-P increased. Even though the effluent SS, BOD and T-P concentrations showed almost no effect, the COD and TKN concentrations increased. The microbial yield coefficient decreased at a rate of 0.91 g SS/g COD removed as the irradiation ratio increased at a rate of 1 g SS/g SS-day.

Uncertainty of Discharge-SS Relationship Used for Turbid Flow Modeling (탁수모델링에 사용하는 유량-SS 관계의 불확실성)

  • Chung, Se-Woong;Lee, Jung-Hyun;Lee, Heung-Soo;Maeng, Seung-Jin
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.12
    • /
    • pp.991-1000
    • /
    • 2011
  • The relationship between discharge (Q) and suspended sediment (SS) concentration often is used for the estimation of inflow SS concentration in reservoir turbidity modeling in the absence of actual measurements. The power function, SS=aQb, is the most commonly used empirical relation to determine the SS load assuming the SS flux is controlled by variations of discharge. However, Q-SS relation typically is site specific and can vary depending on the season of the year. In addition, the relation sometimes shows hysteresis during rising limb and falling limb for an event hydrograph. The objective of this study was to examine the hysteresis of Q-SS relationships through continuous field measurements during flood events at inflow rivers of Yongdam Reservoir and Soyang Reservoir, and to analyze its effect on the bias of SS load estimation. The results confirmed that Q-SS relations display a high degree of scatter and clock-wise hysteresis during flood events, and higher SS concentrations were observed during rising limb than falling limb at the same discharge. The hysteresis caused significant bias and underestimation of SS loading to the reservoirs when the power function is used, which is important consideration in turbidity modeling for the reservoirs. As an alternative of Q-SS relation, turbidity-SS relation is suggested. The turbidity-SS relations showed less variations and dramatically reduced the bias with observed SS loading. Therefore, a real-time monitoring of inflow turbidity is necessary to better estimate of SS influx to the reservoirs and enhance the reliability of reservoir turbidity modeling.

T-P Removal Efficiency According to Coagulant Dosage and Operating Cost Analysis (응집제 투입에 따른 인 제거 효율 및 운영비용 분석)

  • Yun, Soyoung;Ryu, Jaena;Oh, Jeill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.8
    • /
    • pp.549-556
    • /
    • 2012
  • T-P removal efficiency was analyzed according to the metal to initial T-P ratio (mole basis) with respect to the samples from different WWTPs having various initial T-P and SS conditions. Also, operating costs were calculated based on the injected coagulant amount and the amount of sludge production. Most experiments were conducted by the standard jar-test protocol. Molar ratio of coagulant dose was varied considerably according to the initial SS concentration range in secondary clarifier effluent samples which had above 0.5 mg/L of initial T-P. Based on 90% T-P removal efficiency, results were: At the initial SS range of below 10 mg/L, Alum (8%) = 11 mol Al/mol P needed and PAC (17%) = 9.6 mol Al/mol P needed; At the initial SS range of above 10 mg/L, Alum (8%) = 3.9 mol Al/mol P needed and PAC (17%) = 3.2 mol Al/mol P needed.

Effects of Sorbed Surfactant on the Surfactant-Enhanced Removal of Hydrophobic Organic Contaminants (토양에 흡착된 계면활성제가 유기오염물 제거에 미치는 영향)

  • 고석오;유희찬
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.2
    • /
    • pp.77-86
    • /
    • 1999
  • Partitioning of two hydrophobic organic compounds (HOCs), phenanthrene and naphthalene, to kaolinite and sorbed surfactants was studied to evaluate the feasibility of surfactant-enhanced remediation (SER) of contaminated subsurface systems. Sorbed surfactant partition coefficients. $K_ss$, showed a strong dependence on the surfactant sorption isotherms at low sorbed surfactant levels $K_ss$ values were at their highest and then decreased with increasing surfactant sorption densities. $K_ss$ values for SDS were always larger than corresponding $K_mic$values. For Tween 80, however. $K_ss$ values $K_mic$ were higher than $K_mic$ values only at the lower sorbed surfactant densities. HOC distribution between immobile and mobile phases varied with surfactant dose distribution coefficients increased initially with increasing surfactant concentrations and then decreased at higher doses. This observation shows directly the competition between sorbed and micellar surfactants for HOC partitioning. Overall results of this study demonstrate that surfactant sorption to the solid phase can lead to increases in HOC retardation in some SER applications. Therefore, before an SER process is selected, appropriate consideration of surfactant sorption and HOC partitioning to immobile versus mobile phases pertinent to a specific subsurface system must be contemplated.

  • PDF

Water Quality Fluctuation Study of Paldang Reservoir Affected by Gyeongan Stream Inflow according to Rainfall (강우기 및 비강우기 경안천 수체흐름에 의한 팔당호 수질변동 비교 평가)

  • Heo, Seong-Nam;Noh, Hye-Ran;Yang, Hee-Jeong;Jeong, Dong-Il;Kim, Jong-Min
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.2 s.116
    • /
    • pp.236-244
    • /
    • 2006
  • Water quality fluctuation of Gyeongan water area in Paldang reservoir, which measured from the downstream sampling point of Gyeongan stream (G1) to dam sampling point (P), was examined in the light of seasonal rainfall and regional difference in the year of 2002. Annual COD, T-P and T-N concentration dropped conspicuously at the point P (in front of dam) although concentration of Gl point was high. Concentration variation of COD, T-P and T-N from Gl to P point in Gyeongan area was small in August and September. And at G l point showed relatively low concentration. Chlorophyll-a concentration varies less during the autumn season (October to December) than spring season (March to June). Water temperature of Bughangang (north Han-river) area was relatively lower in August and higher in November compared with that of other areas. COD and SS concentration showed big regional difference except in November when the concentrations of which were relatively low. The high Chlorophyll-a concentration of April fell conspicuously in rainy season. Gyeongan area, where the water depth is relatively shallow, indicated steep temperature gradient in April compared with that in August or November. High 55 concentration in April at P point characterized surface layer while the opposite was recorded in August. Mixing of upper and lower layers had taken place causing dilution of COD, T-N and T-P concentration in August. This condition was maintained throughout November. Therefore, spring-summer seasons needed more attention for water management countermeasure than summer-autumn seasons.

Regional Variation and Discharge Characteristics of Stream Water Quality and Heavy Metals Around the Shihwa Lake Basin (시화호 유역 하천수 일반수질 및 중금속의 변화 및 유출 특성 연구)

  • Jeong, Hyeryeong;Kim, Kyung-Tae;Kim, Eun-Soo;Lee, Seung-Yong;Ra, Kongtae
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.20 no.2
    • /
    • pp.76-83
    • /
    • 2017
  • In order to investigate the characteristics of water quality and heavy metals in Shihwa Lake, concentration comparisons according to land use types and mass discharge through streams were carried out. Based on classification for streams according to land use types, the concentration of DO, SS, POC, $NO_3$ and Chl-a showed higher concentrations in agricultural areas than in industrial and urban areas. However, COD, DIN, DIP, TN, TP, DOC, TOC and heavy metal concentrations showed relatively high values in industrial areas. The concentrations of water qualities and heavy metals were relatively high in March to May and the concentration decreased in summer seasons (July-August). The averages of stream discharges of water qualities were 1,172 kg/d for SS, 151 kg/d for TN, 11.1 kg/d for TP and 389 kg/d for TOC, respectively. The agricultural area, Jangjunbo(S8), accounted for 47.5%(TP)~75.1%(SS) in the total stream discharges. Cu, Zn and Cd in stream waters were found to be more than 92% of the total discharges in industrial area, showing descending order of Zn>Cu>Ni>Pb>Co>Cd.

Effects of Disinfectant Concentration, pH, Temperature, Ammonia, and Suspended Solids on the Chlorine Disinfection of Combined Sewer Overflow (소독제 농도, pH, 온도, 암모니아 농도, 부유물질이 강우 월류수 염소 소독에 미치는 영향)

  • Kim, Sang-Hyoun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.10
    • /
    • pp.685-690
    • /
    • 2014
  • The treatment of combined sewer overflow (CSO) is one of potential concerns in domestic wastewater treatment in Korea due to the pre-announce of CSO regulations. This work investigated the effects of disinfectant (NaOCl) concentration (0.11 to 4.0 mg $Cl_2/L$), pH (6.5 to 8.0), temperature (15 to $25^{\circ}C$), ammonia (10 to 41 mg N/L), and suspended solids (91 to 271 mg SS/L) on the chlorine disinfection of CSO. The effect of NaOCl concentration on the pseudo-$1^{st}$ order reaction rate for total coliform inactivation was described well with a saturation-type model with the half-velocity constant of 1.212 mg/L. The total coliform inactivation reaction rate decreased with SS and pH, and increased with temperature. Ammonia in the examined range did not affect the disinfection kinetics. A chlorine contact tank with the injection chlorine level of 1 mg $Cl_2/L$ and the hydraulic retention time of 1.25 min is estimated to reduce total coliform from $1{\times}10^5MPN/mL$ to 1,000 MPN/mL at 271 mg SS/L, $15^{\circ}C$, and pH 8.0. Chlorine would be a proper option for the disinfection of CSO.

First-flush Runoff Characteristics of NPS from golf course (골프장에서 발생하는 비점오염원의 초기유출수 특성)

  • Shin, Min-Hwan;Choi, Jae-Wan;Choi, Yong-Hun;Seo, Ji-Yeon;Lee, Jae-Woon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1129-1133
    • /
    • 2010
  • 본 연구에서는 수질오염총량제와 정책제안의 원활하고 합리적인 추진을 위해 토지피복분류체계의 대분류중 초지에 해당하고 중분류 중 골프장에 해당하는 지점을 선정하여 강우에 의해 발생하는 비점오염물질의 유출특성을 분석하였다. 연구기간 동안 총 27번의 강우사상으로 인해 발생하는 강우유출수에 대하여 유량과 수질농도를 측정하였다. 유량측정은 웨어를 통한 수위를 측정하여 유량으로 환산하였고, 수질항목은 $BOD_5$, $COD_{Mn}$, DOC, SS, T-N, T-P, $NH_3$-N, $NO_3$-N, $PO_4$-P 등 9개 항목을 분석하였다. 분석된 결과를 이용하여 골프장에서 발생하는 비점오염원의 초기세척효과 발생여부를 판단하기 위하여 누적오염부하량/누적유출량 그래프를 도식화하였다. 연구기간동안 발생한 5~82 mm의 강우로 인해 6.6~2,082 $m^3$의 유출이 발생하였다. 발생된 유출수의 농도는 $BOD_5$ 1.8~11.3 mg/L, $COD_{Mn}$ 19.2~51.4 mg/L, DOC 11.0~31.0 mg/L, SS 2.2~57.3 mg/L, T-N 1.545~16.098, T-P 0.230~4.528 mg/L, $NH_3$-N 0.076~5.285 mg/L, $NO_3$-N 0.122~2.905 mg/L, $PO_4$-P 0.005~2.631 mg/L로 나타났다. 초기유출수의 세척효과는 27번의 강우사상동안 SS 항목의 경우 17번, $NO_3$-N 11번, $NH_3$-N 4번 등이 발생하였다. 초기세척효과가 발생한 강우사상은 초기의 오염원 농도가 중 후반 농도보다 농도가 높음을 의미하므로, 골프장에서 발생하는 강우유출수는 초기에 발생하는 오염원에 초점을 두고 처리방안을 모색해야 할 것으로 판단된다. 또한 SS와 질소계열의 농도가 높은 것은 골프장의 잔디관리를 위한 농약이나 제초제 등의 사용과 토양유실이 원인인 것으로 판단되며, 이를 저감하기 위한 적절한 사용방안과 저감대책이 필요할 것으로 판단된다.

  • PDF

Estimation of Suspended Solids Concentration Caused by Stream Bed Excavation Works through the Application of the Fickian Diffusion Model (Fick 확산 모형을 이용한 하상 굴착 공사로부터의 부유물질 농도 산정)

  • An, Myeong-Gil
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.6
    • /
    • pp.621-628
    • /
    • 1997
  • Excavation works on stream beds have been done for various reasons including aggregate collection, sediment dredging, bridge constructions, or laying pipes under the ground. These activities may cause significant loadings of SS (suspended solids) resulting in water pollution and other detrimental effects to the surrounding environment. This research investigates application potential of a fickian diffustion model, derived from two dimensional advection-diffusion equation through some simplifying assumptions, as a planning tool for the estimation of SS loadings from excavation works and evaluation fo pollution prevention measures in case that sophisticated numerical simulation models are not applicable due to various practical reasons. Through a case study of the Juncheon stream in the Donghae City on the Kangwondo Province, this study demonstrates applicability of the fickian diffustion model as a practical method for the preliminary estimation of Ss loadings from excavation works and evaluation of performance of fabrics made of synthetic fiber for the reduction of downstream SS concentration with deficient field data.

  • PDF

Change Pattern Analysis of the Salinity, 55 and DO Concentrations in Jumunjin Harbour, Gangneung (강릉 주문진항 염도, 탁도 및 응존산소 농도 변화양상 분석)

  • Cho, Hong-Yeon;Kim, Chang-Il;Lee, Dal-Soo;Han, Dong-Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.4
    • /
    • pp.385-398
    • /
    • 2007
  • It was analysed that spatial and temporal change patterns of general water quality constituents were measured monthly from 2002 to 2005 in Jumunjin Harbour. The measured constituents are temperature, salinity, pH, SS and DO. Concentration difference of upper lower layer for general water quality constituents was small. Temperature and DO concentration show the clear difference at temporal concentration change pattern, but SS, pH and salinity have irregular change pattern. Also, water quality improvement effect of seawater exchange facilities and sewage treatment plants is analysed quantitatively using averaged spatial and temporal data set. From this result, it is found that effect of sewage treatment plants is small and seawater exchange facilities at zone 1 and 2 is clear concentration reduction effect to be about 26% and 16%, respectively. After sewage treatment plants operation, DO concentration reduced about 10% at inner zone of Jumunjin Harbour, the other side, after seawater exchange facilities concentration DO concentration increased about 10%. DO concentration at 2005 estimated little than that of 2002, it is concluded that a yearly change of DO concentration has about 10%.