• Title/Summary/Keyword: SRD

Search Result 62, Processing Time 0.031 seconds

A Timing Recovery Scheme for Variable Symbol Rate Digital M-ary QASK Receiver (가변 심볼율 MQASK(M-ary Quadrature Amplitude Keying) 디지털 수신기를 위한 타이밍 복원 방안)

  • Baek, Daesung;Lim, Wongyu;Kim, Chong-Hoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.7
    • /
    • pp.545-551
    • /
    • 2013
  • Timing recovery loop composed of the Timing Error Detector(TED), loop filter and resampler is widely used for the timing synchronization in MQASK receivers. Since TED is sensitive to the delay between the symbol period of the signal and sampling period, the output is averaged out when the symbol rate and sampling rate are quite different the recovery loop cannot work at all. This paper presents a sampling frequency discriminator (SRD), which detects the frequency offset of the sampling clock to the symbol clock of the MQASK data transmitted. Employing the SRD, the closed loop timing recovery scheme performs the frequency-aided timing acquisition and achieve the synchronization at extremely high sampling frequency offset, which can be used in variable symbol rate MQASK receivers.

The inter-rater absolute reliability and validity of the Figure-of-8 Walk test in patients with chronic stroke (만성 뇌졸중 환자 8자 모양 경로 보행 검사의 측정자간·절대적 신뢰도와 타당도)

  • Park, Chang-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.467-474
    • /
    • 2017
  • To investigate the intra-rater absolute reliabilities and validity of the Figure of-Eight Walk test (F8WT) in patients with chronic stroke. A total of 36 subjects with chronic stroke participated in this study. The inter-rater reliability of F8WT was calculated using intra-class correlation coefficients($ICC_{2,1}$). Moreover, we used the standard error measurement (SEM) and the small real difference (SRD) to examine the absolute reliability indices. The validity was demonstrated by a spearman correlation of F8WT with Postural Assessment Scale for Storke(PASS) and Trunk Impairment Scale(TIS). The inter-rater reliability of F8WT was excellent; ICC2,1=0.95(0.91~0.97), acceptable SEM=1.02, and SRD=2.82. F8WT were also found to be significantly associated with PASS(r=-0.82) and TIS(r=-0.85). Therefore, F8WT is a reliable measurement tool and is correlated well with stroke-impairments, such as postural and trunk control. F8WT will be a useful tool in evaluating the walking performance of subjects with chronic stroke.

Reliability and Validity of Gait Assessment Tools for Elderly Person (노인의 보행에 대한 평가 도구의 신뢰도와 타당도 조사 연구)

  • Kim, Jae-Hyun
    • The Journal of Korean Physical Therapy
    • /
    • v.21 no.1
    • /
    • pp.41-48
    • /
    • 2009
  • Purpose: The examine the Reliability and Validity of the modified Emory Functional Ambulation Profile (mEFAP), Tinetti. Gait (TG), Timed Up & Go Tes t (TUG), Comfortable Gait Speed (CGS), Berg Balance Scale (BBS) in assessing gait function and balance in elderly person. Methods: The 45 community-dwelling subjects were participated in this study. Reliability was determined by intra-class correlation coefficient (ICC$_{3,1}$), Bland and Altman method (Standard Error of Measurement (SEM), Smallest Real Difference (SRD)). Results: Validity was examined by correlation the mEFAP, TG, TUG, CGS, BBS. The intra-rater reliability were High (ICC$_{3,1}$ : mEFAP=0.95, TG=0.96, TUG=0.94, CGS=0.96, BBS=0.92) and Absolute reliability were excellent (SEM: mEFAP=1.90, TG=0.21, TUG=0.28 CGS=0.25, BBS=0.52), (SRD: mEFAP=5.26, TG=0.58, TUG=0.77, CGS=0.69, BBS=1.44). There were significant correlations between assessment tool (r=.0.58$\sim$0.78, p<0.01) indicating good validity. Our results provide strong evidence that the assessment tool has good reliability, validity for assessing elderly person undergoing rehabilitation. Conclusion: The gait assessment tool is a useful scale for measuring walking function and recovery in elderly person.

  • PDF

Implementation and miniaturization of High Order Derivative Gaussian Pulse Generator for DS-UWB (DS-UWB를 위한 고차 미분 가우시안 펄스 생성기의 소형화와 구현)

  • Kim, Dong-Ho;Bang, Gyeong-Nam;Park, Chong-Dae
    • Journal of IKEEE
    • /
    • v.10 no.2 s.19
    • /
    • pp.109-115
    • /
    • 2006
  • In this paper, High order derivative Gaussian pulse generator for DS-UWB communication satisfying the regulation of FCC was proposed and fabricated. In order to transform rectangular signal of 100Mbps to a Gaussian pulse, the fabricated Gaussian pulse generator consists of only two SRD. The output pulse had the widths of 330 psec and amplitudes of 920 mV. In addition, the designed and fabricated dual bandpass filter shows high order derivate characteristics by using micro-strip line and parallel stub to remove WLAN band. We generated the 13th Gaussian pulse restricted frequency spectrum of WLAN band more than -25dB. The pulse had pulse width of 1 nsec and amplitude of 25 mV.

  • PDF

A Study on Design and Fabrication of SRD Impulse Generator and Antenna for Ground Penetrating Radar System (지반투과 레이더 시스템을 위한 SRD 임펄스 발생기 및 안테나의 설계 및 제작에 관한 연구)

  • Kim, Hyoung-Jong;Shin, Suk-Woo;Choi, Gil-Wong;Choi, Jin-Joo;Shin, Shang-Youal
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.509-516
    • /
    • 2011
  • In this paper, a ground penetrating radar(GPR) system is implemented for landmine detection. The performance of the GPR system is associated with the characteristics of local soil and buried target. The choice of the center frequency and the bandwidth of the GPR system are the key factors in the GPR system design. To detect a small and shallow target, the higher frequencies are needed for high depth resolution. We have been designed, fabricated and tested a new impulse generator using step recovery diodes. The measured impulse response has an amplitude of 6.2V and a pulse width of 250ps. The implemented GPR system has been tested real environmental conditions and has proved its ability to detect a small buried target.

Seismic response distribution estimation for isolated structures using stochastic response database

  • Eem, Seung-Hyun;Jung, Hyung-Jo
    • Earthquakes and Structures
    • /
    • v.9 no.5
    • /
    • pp.937-956
    • /
    • 2015
  • Seismic isolation systems decouple structures from ground motions to protect them from seismic events. Seismic isolation devices have been implemented in many full-scale buildings and bridges because of their simplicity, economic effectiveness, inherent stability, and reliability. It is well known that the most uncertain aspect for obtaining the accurate responses of an isolated structure from seismic events is the seismic loading itself. It is needed to know the seismic response distributions of the isolated structure resulting from the randomness of earthquakes when probabilistic designing or probabilistic evaluating an isolated structure. Earthquake time histories are useful and often an essential element for designing or evaluating isolated structures. However, it is very challenging to gather the design and evaluation information for an isolated structure from many seismic analyses. In order to evaluate the seismic performance of an isolated structure, numerous nonlinear dynamic analyses need to be performed, but this is impractical. In this paper, the concept of the stochastic response database (SRD) is defined to obtain the seismic response distributions of an isolated structure instantaneously, thereby significantly reducing the computational efforts. An equivalent model of the isolated structure is also developed to improve the applicability and practicality of the SRD. The effectiveness of the proposed methodology is numerically verified.

Pelvic MRI Application to the Dosimetric Analysis in Brachytherapy of Uterine Cervix Carcinoma (자궁경부암의 강내조사치료에 있어서 흠수선량평가시 골반강 자기공명사진의 응용)

  • Chung, Woong-Ki;Nah, Byung-Sik;Ahn, Sung-Ja
    • Radiation Oncology Journal
    • /
    • v.15 no.1
    • /
    • pp.57-64
    • /
    • 1997
  • Purpose : Before we report the results of curative radiotherapy in cervix cancer patients, we review the significance and safety of our dose specification methods in the brachytherapy system to have the insight of the potential Predictive value of doses at specified points. Matersials and Methods : We analyze the 리5 cases of cervix cancer patients treated with intracavitary brachytherapy in the lateral simulation film we draw the isodose curve and observe the absorbed dose rate of point A, the reference point of bladder(SBD) and rectum(SRD). In the sagittal view of Pelvic MRI film we demarcate the tumor volume(TV) and determine whether the prescription dose curve of point A covers the tumor volume adequately by drawing the isodose curve as correctly as possible. Also we estimate the maximum Point dose of bladder(MBD) and rectum(MRD) and calculate the inclusion area where the absorbed dose rate is higher than that of point A in the bladder(HBV) and rectum(HRV), respectively. Results : Of forty-five cases, the isodose curve of point A seems to cover tumor volume optimally in only 24(53%). The optimal tumor coverage seems to be associated not with the stage of the disease but with the tumor volume. There is no statistically significant association between SBD/SRD and MBD/MRD, respectively. SRD has statistically marginally significant association with HRV, while TV has statistically significant association with HBV and HRV. Conclusion : Our current treatment calculation methods seem to have the defect in the aspects of the nonoptimal coverage of the bulky tumor and the inappropriate estimation of bladder dose. We therefore need to modify the applicator geometry to optimize the dose distribution at the position of lower tandem source. Also it appears that the position of the bladder in relation to the applicators needs to be defined individually to define 'hot spots'.

  • PDF

Current Issues for the Material Balance Evaluation in NFFP

  • Na, Won-Woo;Park, Wan-Sou;Ahn, Seung-Ho
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2004.10a
    • /
    • pp.1447-1448
    • /
    • 2004
  • As the plants are classified as a bulk facility by the Agency's safeguards criteria, the Material Balance Evaluation is a good tool to timely detect diversion that will be accomplished through the creation of defects as small as bias defects. Through all evaluations made by the Agency, it Is strongly recommended to report SRD based on both weight and enrichment, maintain the reliable MUF declaration and improve the gamma spectrometry measurement procedure. These recommendations have been now applied and are going on.

  • PDF

A Study on the Implementation of Wideband Hybrid Quadrature Polar Transmitter Platform (광대역 하이브리드 직교 폴라 송신 플랫폼 구현에 관한 연구)

  • Chang, Sang-Hyun;Lee, Il-Kyoo;Kim, Hyung-Jung;Kang, Sang-Ki
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.1A
    • /
    • pp.28-34
    • /
    • 2011
  • In this paper, we proposed the architecture of the Hybrid Quadrature Polar transmitter which has the wideband characteristics available for the SRD(Short Range Device). First, we developed the simulation environment and carried out performance degradation analysis. Second, we considered the slewrate of the VVA(Voltage Variable Attenuator), time delay between magnitude signal and phase signal and the number of bits for DAC(Digital-to-Analog Converter) as the main performance factors. Then we obtained the minimum required values to meet the transmitting performance requirements of 3GPP standards through simulation results. Based on these results, we implemented the Wideband Hybrid Quadrature Polar transmitter platform and varified the performance requirements through practical measurement.

Estimation of Thermodynamic/Transport Properties of Kerosene using a 3-Species Surrogate Mixture (3-화학종 대체 혼합물을 이용한 케로신의 열역학적·전달 상태량 예측)

  • Joh, Miok;Kim, Seong-Ku;Choi, Hwan-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.11
    • /
    • pp.874-882
    • /
    • 2013
  • Kerosene(Jet A-1), one of the propellants for each stage's engine of the Korea Space Launch Vehicle-II(KSLV-II), functions as coolant at the same time as it flows inside the cooling jacket of the combustion chambers and is injected through the film cooling holes. A physical surrogate mixture model to reproduce the thermophysical characteristics of Jet A-1 has been selected and the thermodynamic/transport properties of the model fuel under high pressure including supercritical conditions have been estimated using SUPERTRAPP(NIST SRD4). Comparisons with the measured properties suggest that proposed database can be used to extract properties of Jet A-1 for conjugate heat transfer analysis of liquid propellant rocket engine thrust chambers. Predicted combustion/cooling performance of regeneratively cooled thrust chambers shall be validated through comparisons with upcoming firing test results.