• Title/Summary/Keyword: SR-332

Search Result 18, Processing Time 0.034 seconds

A Study on the Oxidation of Carbon Monoxide for Exhaust of Car Engine by the $LaSrNiCoO_3$ Low Noble Metal Catalyst (저귀금속 $LaSrNiCoO_3$ 촉매에 의한 자동차 배기중의 일산화탄소의 산화반응에 관한 연구)

  • 이근배;이석희
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.6 no.1
    • /
    • pp.57-72
    • /
    • 1990
  • The oxidation of carbon monoxide on a catalyst, $LaSrNiCoO_3$ was investigatigated with a plug flow system. Kinetic quantities such as reaction-rate, reaction order and Arhenius-parameters at various reactor temperature from 200$^\circ$C to 300$^\circ$C were determined. Also, the optimum condition for the oxidation of carbon monoxide with this catalyst was determined and are as follows. Partial pressure of oxigen ; 428mmHg Partial pressure of carbon monoxide ; 332mmHg Mixed moral ratio of oxigen and Carbon monoxide ; 1.3 : 1 Total gas flow ; 224ml/min Reaction temperature ; 340$^\circ$C The reaction kinetic equation at the optimum condition, temperature range from 200$^\circ$C to 340$^\circ$C, are as follow. $$ $v = Ae^{6.5Kcal/RT} [CO]^{0.93 \sim 0.98} [O_2]^{0.42 \sim 0.50}$ $$ In addition to this, numerical calculation were performed to evaluate the mass and heat transfer effect on this system.

  • PDF

FMEDA Analysis for the Protection Controller F-LIC of ITER AC/DC Converters (ITER AD/DC Converter의 보호제어기 F-LIC에 대한 FMEDA 분석)

  • Shin, Hyun Kook;Oh, Jong-Seok;Suh, Jae Hak;Chung, In Seung;Lee, Lack Sang
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.121-122
    • /
    • 2017
  • ITER AC/DC 컨버터(Converter)는 핵융합 발생을 위해 토카막의 초전도코일에 제어된 전류를 공급하여 플라즈마 발생, 형상 유지, 소멸하는 기능을 한다. 만일 컨버터 또는 초전도코일에 이상이 발생하면 즉시 보호동작이 실행되어야 한다. 이를 위해 설계된 F-LIC(Fast Local Interlock Controller)은 즉시 작동하여 Bypass 및 Make Switch 트리거, 차단기 작동 등을 순차적으로 수행한다. ITER Interlock System의 기기는 중요성이 고려되어 높은 신뢰도가 요구된다. 본 논문에서는 F-LIC 회로분석과 Telcordia SR-332 Standard에 의한 부품고장률 산출방법을 사용하여 FMEDA를 분석하고, 이를 통하여 회로구성 부품의 고장이 미치는 영향과 F-LIC 제어모듈의 SIL-2 등급의 적합성을 분석하였다.

  • PDF

Reliability for Failure Rates Different over Time Intervals (고장률이 시간 구간별로 다른 경우의 신뢰도)

  • Jeon, Tae-Bo
    • Journal of Industrial Technology
    • /
    • v.27 no.B
    • /
    • pp.245-253
    • /
    • 2007
  • Failure rate serves as a pivotal role in reliability study. Of all, the constant failure rate is the most popularly used in field exercises. In reality, however, the electrical and electronic parts' life is represented by not only the constant failure rate but the decreasing and/or increasing failure rates. Explicit consideration and incorporation of them into the model development may yield more desirable results. In this study, we built a reliability model for failure rates varying over time intervals and derived well known measures such as probability density function, reliability function, mean life, moments, and mission time. We then evaluated mean life with consideration of the first-year multiplier and compared the results those with constant failure rate. The results given in the study may provide a reference applying for practical decision making.

  • PDF

Evaluation of Probability of Failure on Demand (PFD) for Emergency Diesel Generator Excitation Control System (디젤발전기 여자시스템의 고장확률 분석에 관한 연구)

  • Lee, Joo-Hyun;Lim, Ick-Hun;Rhew, Ho-Sun;Huh, Tae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1934-1935
    • /
    • 2007
  • 본 논문은 원자력발전소 안전계통인 비상전원 공급용 디젤발전기의 여자시스템에 대해서 신뢰성 불럭선도를 이용하여 시스템을 모델링하고, 신뢰성 분석을 수행하고 그 결과 기동요구시 실패확률을 산출하는 방법과 결과를 기술하였다. 비상디젤발 전기 여자시스템을 구성하는 모든 부품의 고장률을 Telcordia SR-332 기준서의 부품수 방법을 이용하여 분석하고 FMEA (Failure Mode Effect Analysis)를 수행하며 IEC 61508에서 제시하고 있는 기동요구 시 실패확률(Probability of Failure on Demand, PFD)을 산출하였다.

  • PDF

A Study on Method for Classifying Quality Levels of Commercial Electric & Electronic Parts (상용 전기전자 부품의 품질등급 적용 방안에 관한 연구)

  • Jeong, Da-Un;Yun, Hui-Sung;Kwak, Cho-Rong;Lee, Seung-Hun;Hur, Man-Og
    • Journal of Applied Reliability
    • /
    • v.12 no.1
    • /
    • pp.1-12
    • /
    • 2012
  • The quality of a part has directly effect on part reliability. In the basis of MIL-HDBK-217F model, it is the determined rule that part's quality level should follow its nominal one written in its specification. If quality information is unknown, quality level of the part should be determined as 'Lower'. However, the prediction model is said to be short in reflecting parts applying 'state-of-the-art' technology and result in over-estimated failure rate by some reliability-related authorities or research institutes. In this study, the reliability prediction results by the model of MIL-HDBK-217F and Telcordia SR-332 are compared and analyzed to verify whether the statement is reasonable or not.

Petrology and petrochemistry of the Jurassic Daebo granites in the Pocheon-Gisanri area (포천 - 기산리 일대에 분포하는 쥬라기 대보화강암류의 암석 및 암석화학)

  • 윤현수;홍세선;이윤수
    • The Journal of the Petrological Society of Korea
    • /
    • v.11 no.1
    • /
    • pp.1-16
    • /
    • 2002
  • The study area is mostly composed of Precambrian Gyeonggi gneiss complex, Jurassic Daebo granites, Cretaceous tonalite and dykes, and so on. On the basis of field survey and mineral assemblage, the granites can be divided into three types; biotite granite (Gb), garnet biotite granite (Ggb) and two mica granite (Gtm). They predominantly belong to monzo-granites from the modes. Field relationship and K-Ar mica age data in the surrounding area suggest that intrusive sequences are older in order of Gtm, Ggb and Gb. Gb and Ggb, major study targets, occur as medium-coarse grained rocks, and show light grey and light grey-light pink colors, respectively. Mineral constituents are almost similar except for opaque in Gb and garmet in Ggb. Gb and Ggb have felsic, peraluminous, subalkaline and calc alkaline natures. In Harker diagram, both rocks show moderately negative trends of $TiO_2$, MgO, CaO, $Al_2O_3$, $Fe_2O_3$(t), $K_2O$ and $P_2O_5$ as $SiO_2$ contents increase. Among them, $TiO_2$, MgO and CaO show two linear trends. From the trends and the linear patterns in AFM, Sr-Ba and Rb-Ba-Sr relations, it is likely that they were originated from the same granitic magma and Ggb was differentiated later than Gb. REE concentrations normalized to chondrite value have trends of parallel LREE enrichment and HREE depletion. One data of Ggb showing a gradually enriched HREE trend may be caused by garnet accompaniment. Ggb have more negative Eu anomalies than Gb, suggesting that plagioclase fractionation in Ggb have occurred much stronger than that in Gb. In modal (Qz+Af) vs. Op, Gb and Ggb belong to magnetite-series and ilmenite-series, respectively. From the EPMA results, opaques of Gb are magnetite and ilmenite, and those of Ggb are magnetite-free ilmenite or not observed. Bimodal distribution of magnetic susceptibility reveals two different granites of Gb (332.6 ${mu}SI$) and Ggb (2.3 ${mu}SI$). Based on the paleomagnetic analysis as well as modal analysis, the main susceptibilities of Gb and Ggb reside in magnetite and mafic minerals, respectively. They belong to S-type granite of non-magnetic granite by susceptibility value. In addition, $SiO_2$ contents, $K_2O/Na_2O$, A/CNK molar ratio and ACF diagram support that they all belong to S-type granites.

Impurity variation in high purity silica mineral with different leaching methods (실리카광물의 산침출 정제방법에 따른 불순물 변화 연구)

  • Yoon, Yoon Yeol;Lee, Kil Yong;Cho, Soo Young;Chung, Soo Bok;Chae, Young Bae
    • Analytical Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.332-337
    • /
    • 2008
  • Purification of silica mineral was compared with various leaching methods such as shaking, stirring, ultrasonic with 2.5% HF/HCl solution. Among them, ultrasonic method showed a best leaching effect. From the leaching experiment, Na, K, Fe, Al exist as the major impurity elements. The removal rate of Al, Fe showed little difference with various leaching methods but Ca, Mn, Na were very different. Four kinds of silica mineral (>99% purity) after physical purification treatment were used for ultrasonic leaching experiment. Among them IN-Si had a highest impurity removal rate. Ca, Cr, K, Zn were removed above 80% using ultrasonic leaching method and Fe was also removed above 60%. But Al showed 10~60% removal rate with different samples.

Analysis of the Concentration of Metal Elements in Freshwater Fish Otolith Using LA-ICP/MS (LA-ICP/MS를 이용한 담수 어류 이석 내 금속 원소 농도 분석)

  • Park, Hyun Woo;Yoon, Suk-Hee;Park, Jaeseon;Lim, Bo-Ra;Lee, Hyeri;Choi, Jong Woo
    • Korean Journal of Ecology and Environment
    • /
    • v.52 no.4
    • /
    • pp.324-332
    • /
    • 2019
  • In this study, the possibility of a follow-up study on environmental pollution in domestic freshwater was identified by analyzing fish otoliths using Laser ablation-inductively coupled mass spectrometry (LA-ICP/MS). Fish otolith are known to be affected by the environment in which fish live. As a result, research on this subject is active in many countries; however, this is not the case in Korea. Therefore, in this study, the possibility of tracing environmental pollution using fish otoliths was identified by analyzing the components of metal elements used as indicators for environmental pollution. For the component analysis of metallic elements LA-ICP/MS, which can shorten analysis time by reducing the pretreatment process, was used. Sampling was conducted by dividing the research and the background area and carp, a freshwater species, was selected as the experimental fish species subject. Based on the established LA-ICP/MS conditions, the concentration of the metallic elements in the fish otoliths collected in the research area was 2202.9 mg kg-1, 2.03 times higher than the 1,086.3 mg kg-1 in the background area. All elements except for Li and U, were found to be higher in the research area than in the background area. Compared with the sediment measuring net analysis data, the distribution tendency of Zn, Pb, and Cu in sediment metal element concentrations in the two regions and distribution of metal element concentration in fish otoliths were similarly shown. These results confirm that fish otoliths can be used to track environmental pollutants, such as in sediments.