• Title/Summary/Keyword: SPWM inverter

Search Result 58, Processing Time 0.02 seconds

Development And Application of Three-phase Inverter Output Wave Generator based on SPWM Control to Verify the Performance of LCL filters (LCL 필터의 성능 검증을 위한 SPWM 제어기반의 3상 인버터 출력 파형 발생 장치 개발 및 적용 연구)

  • Im, Dong-Kyun;Kang, Chang-Kyun;Ha, Won-Jin;Sandagdorj, Chuluunbaatar;Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.5
    • /
    • pp.841-852
    • /
    • 2022
  • In this paper, a 3-phase inverter output waveform generator based on SPWM control was developed to verify the performance of the LCL filter. In order to obtain a test signal for verifying the performance of the filter, first, a DSP-based 3-phase SPWM signal generation algorithm was developed, and then a three-phase voltage source inverter circuit was designed using three half-bridge gate drivers. Next, one LCL filter was experimentally fabricated to verify the effectiveness of the developed SPWM-based 3-phase inverter output waveform generator as a test signal generator, and a DSP-based performance verification system was experimentally constructed. Finally, by comparing the three-phase voltage waveform before and after the LCL filter obtained in the output control experiment with the given time ratio, the effectiveness of the SPWM-based 3-phase inverter output waveform generator was verified.

A Study on the SPWM based Power Conversion Technology of the Three-Phase Photovoltaic Inverter Using DSP (DSP를 이용한 3상 태양광 인버터의 SPWM 전력변환기술에 대한 연구)

  • Kim, Hyo-Seong;Yoo, Ho-Sung;Lee, You-Jung;Jung, Hoon;Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.6
    • /
    • pp.1099-1106
    • /
    • 2017
  • In this paper, a three phase inverter control methodology for photovoltaic generation system, which is a renewable energy source, was studied. The voltage source inverter type of the constant voltage supply type was selected as the three phase photovoltaic inverter, and SWPM method was selected as control technique. a small capacity three phase photovoltaic inverter system, which has a DSP with powerful high speed data processing ability as the main controller and a solar controller as current controller to supply a certain amount of current to charge the battery, was made and tested for SPWM function.

A Study on Microprocessor-Based 3-Phase VVVF Inverter (마이크로 프로세서를 사용한 3상 VVVF 인버터에 관한 연구)

  • 한상수;김재호;최우승
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.6
    • /
    • pp.879-885
    • /
    • 1990
  • The geometrical algorithm for generating a 3-phase SPWM signal for VVVF (Variable Voltage, Variable Frequency) inverter drives is proposed. In this techniques, it is suitable for micro-processor based implementation since the pulsewiths are computable in real time from simple analytic expressions. System hardware consists of the inverter circuit and the 3-phase SPWM signal generating circuit. The inverter circuit is a 3-phase SPWM signal generating circuit is single board micro-processor consisting of Z-80A CPU, EPROMXI, CTC, PIO. The method of controlling VVVF at the inverter output is discussed here.

  • PDF

Elimination of harmonics in three-Phase PWM inverter using auxiliary partial resonant circuit (보조부분 공진 회로를 이용한 삼상 PWM 인버터의 고조파 제거)

  • Suh, Ki-Young;Lee, Hyun-Woo;Kim, Young-Mun;Mun, Sang-Pil
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.137-140
    • /
    • 1998
  • A new SPWM inverter using three-phase boost converter by auxiliary partial resonant with high power factor and high efficiency is proposed. The proposed boost converter is constructed by using a resonant network in parallel with the switch of the conventional boost converter. The devices are switched at zero voltage or zero current eliminating the switching loss. A new Partial resonant boost converter achieves zero-voltage switching (ZVS) or zero-current switching (ZCS) for all switch devices without increasing their voltage and current stresses. This paper introduces elimination of low-order harmonics compared with conventional SPWM inverter and SPWM inverter using three-phase boost converter by auxiliary Partial resonant.

  • PDF

An Improved SPWM Strategy to Reduce Switching in Cascaded Multilevel Inverters

  • Dong, Xiucheng;Yu, Xiaomei;Yuan, Zhiwen;Xia, Yankun;Li, Yu
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.490-497
    • /
    • 2016
  • The analysis of the switch status of each unit module of a cascaded multi-level inverter reveals that the working condition of the switch of a chopper arm causes unnecessary switching under the conventional unipolar sinusoidal pulse width modulation (SPWM). With an increase in the number of cascaded multilevel inverters, the superposition of unnecessary switching gradually occurs. In this work, we propose an improved SPWM strategy to reduce switching in cascaded multilevel inverters. Specifically, we analyze the switch state of the switch tube of a chopper arm of an H-bridge unit. The redundant switch is then removed, thereby reducing the switching frequency. Unlike the conventional unipolar SPWM technique, the improved SPWM method greatly reduces switching without altering the output quality of inverters. The conventional unipolar SPWM technique and the proposed method are applied to a five-level inverter. Simulation results show the superiority of the proposed strategy. Finally, a prototype is built in the laboratory. Experimental results verify the correctness of the proposed modulation strategy.

A Study on the Voltage Control of a Single Phase Full-bridge Inverter using SPWM Driving Method (SPWM 구동 방식을 이용한 단상 풀 브리지 인버터의 전압 제어에 대한 연구)

  • Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.5
    • /
    • pp.851-858
    • /
    • 2017
  • In this study, the voltage control system of a single phase full bridge inverter was designed based on the SPWM driving method. The voltage control system consists of a single-phase full-bridge inverter, a PI controller for linearly compensating the error between the reference voltage and the output voltage, a PWM driving circuit for generating the gate signal using the SPWM method from the controller signal, and an LC filter for filtering the inverter output voltage waveform into sinusoidal waveform. Finally, the voltage control system of a single-phase full-bridge inverter based on the PWM driving method was modeled using EMTP-RV and by showing that the output voltage accurately converges the reference voltage through several simulation examples, the validity of the control system design was verified.

Multilevel Inverter to Reduce Common Mode Voltage in AC Motor Drives Using SPWM Technique

  • Renge, Mohan M.;Suryawanshi, Hiralal M.
    • Journal of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.21-27
    • /
    • 2011
  • In this paper, an approach to reduce common-mode voltage (CMV) at the output of multilevel inverters using a phase opposition disposed (POD) sinusoidal pulse width modulation (SPWM) technique is proposed. The SPWM technique does not require computations therefore, this technique is easy to implement on-line in digital controllers. A good tradeoff between the quality of the output voltage and the magnitude of the CMV is achieved in this paper. This paper realizes the implementation of a POD-SPWM technique to reduce CMV using a five-level diode clamped inverter for a three phase induction motor. Experimental and simulation results demonstrate the feasibility of the proposed technique.

Sinewave-PWM ZVS Inverter using High-Frequency Transformer for Utility AC Voltage Link

  • Chandhaket S.;Ogura K.;Konishi Y.;Nakaoka M.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.511-515
    • /
    • 2003
  • This paper presents a novel prototype of the utility-interfaced sinusoidal pulse width modulated (SPWM) inverter using the high-frequency flyback transformer fur the small-scale solar photo-voltaic power conditioner (1kW - 4kW). The proposed SPWM power conditioner circuit with a high-frequency link has a function of electrical isolation, which is vital fur solar photovoltaic power conditioner systems with the viewpoint of safety and convenience. The discontinuous conduction mode (DCM) operation of the flyback transformer is also maintained to simplify the topology of the inverter circuit and control scheme. First, the operating principle of the proposed circuit is described far the understanding of the circuit parameters establishment. Then, the digitally constructed SPWM control scheme is presented. The proposed circuit is verified by the computer simulation and the prototype experiment.

  • PDF

A Study on the PWM Strategy and Gear Changing Techniques of an Inverter for Variable Speed Drives on Traction Motors (견인전동기 가변속 운전을 위한 인버터의 PWM 방법 및 패턴 절환기법에 관한 연구)

  • Seo, Yeong-Min;Park, Yeong-Jin;Hong, Sun-Chan
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.11
    • /
    • pp.646-654
    • /
    • 1999
  • This paper deals with PWM patterns for harmonic reduction in inverter fed traction motors and the gear changing techniques for the variable speed drive of traction motor. GTOs are used as switching device of inverter because traction motor is a large load. To derive PWM rattern which can minimize the harmonics with the limited switching frequency, the output current and torque characteristic of SPWM and SHE PWM was analyzed. GTO inverter used for traction motor drive includes harmonics in the output current and torque by the limitation of switching frequency. However, the hybrid PWM method that adopt SPWM in the range of low frequency and SHE PWM in upper frequency range can achieve less harmonic characteristics in GTO inverters. If the traction motor is driven in variable speed by the proposed PWM pattern, 7 times of gear changing is needed. At the instant of the mode change, magnetic flux and torque may be altered and the large current flow. To reduce such an undesirable transient behavior, it is also presented the technique for the gear changing of inverter fed traction motor drive operated with the hybrid PWM. The results are verified by simulations and experiments.

  • PDF

Implementation of Cuckoo Search Optimized Firing Scheme in 5-Level Cascaded H-Bridge Multilevel Inverter for Power Quality Improvement

  • Singla, Deepshikha;Sharma, P.R.
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1458-1466
    • /
    • 2019
  • Multilevel inverters have appeared as a successful and utilitarian solution in many power applications. The prime objective of an inverter is to keep the fundamental component of the output voltage of a multilevel inverter at a preferred value. Equally important is the need to keep the harmonic components in the output voltage within stated harmonic limits. Therefore, the basis of this research is to develop a harmonic minimization function that optimizes the switching angles of cascaded H-bridge multilevel inverter. Due to benefits of the Cuckoo Search (CS) algorithm, it is applied to determine the switching angles, which are further used to generate the switching pattern for firing the H-bridges of multilevel inverter. Simulation results are compared with SPWM based firing scheme. The switching frequency for SPWM firing scheme is taken as 200 Hz since the switching losses are increased when switching frequency is high. To validate the ability of Cuckoo Search optimized firing scheme in minimization of harmonics, experimental results obtained from hardware prototype of Five Level Cascaded H-Bridge Multilevel Inverter equipped with a FPGA controller are presented to verify the simulation results.