• Title/Summary/Keyword: SPLC

Search Result 7, Processing Time 0.026 seconds

Exploratory Study of Applying Historiography and SPLC for Developing Information Services: A Case Study of LED Domain (연구지원 정보서비스를 위한 히스토리오그래프와 SPLC 활용에 관한 실험적 연구: LED 분야 사례를 중심으로)

  • Yu, So-Young
    • Journal of the Korean Society for information Management
    • /
    • v.30 no.3
    • /
    • pp.273-296
    • /
    • 2013
  • The purpose of this study is to examine the data coverage and citation threshold for analyzing SPLC(Search Path Link Count) as a main path of a historiograph of a certain topic in order to provide 'core' papers of global research trends to a researcher affiliated with a local R&D institution. 5 datasets were constructed by retrieving and collecting 2,318 articles on RGB LED on Web of Science published from 1990-2013 and 20,109 articles which cited these original 2,318. The SPLC analysis was performed on each dataset by increasing the threshold of citation counts, and the changes and resilience of the 28 extraced networks were compared. The results of user feedback on 198 unique core papers from 28 SPLC networks received from LED researchers affiliated with a Korean government-sponsored research institution were also analyzed. As a result, it is found that the nodes in each SPLC network in each dataset were differentiated by the citation counts, while the changes in the structure of SPLC networks were slight after the networks' citation counts were set at 40. Additionally, the user feedback showed that personalized research interest generally matched to the global research trends identified by the SPLC analysis.

Development of the High Reliable Safety PLC for the Nuclear Power Plants (고신뢰도 안전등급 제어기기 개발)

  • Son, Kwang-Seop;Kim, Dong-Hoon;Son, Choul-Woong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.1
    • /
    • pp.109-119
    • /
    • 2013
  • This paper presents the design of the Safety Programmable Logic Controller (SPLC) used in the Nuclear Power Plants, an analysis of a reliability for the SPLC using a markov model. The architecture of the SPLC is designed to have the multiple modular redundancy composed of the Dual Modular Redundancy(DMR) and the Triple Modular Redundancy(TMR). The operating system of the SPLC is designed to have the non-preemptive state based scheduler and the supervisory task managing the sequential scheduling, timing of tasks, diagnostic and security. The data communication of the SPLC is designed to have the deterministic state based protocol, and is designed to satisfy the effective transmission capacity of 20Mbps. Using Markov model, the reliability of SPLC is analyzed, and assessed. To have the reasonable reliability such as the mean time to failure (MTTF) more than 10,000 hours, the failure rate of each SPLC module should be less than $2{\times}10^{-5}$/hour. When the fault coverage factor (FCF) is increased by 0.1, the MTTF is improved by about 4 months, thus to enhance the MTTF effectively, it is needed that the diagnostic ability of each SPLC module should be strengthened. Also as the result of comparison the SPLC and the existing safety grade PLCs, the reliability and MTTF of SPLC is up to 1.6-times and up to 22,000 hours better than the existing PLCs.

Reliability Analysis of Redundant Architecture of Dependable Control System (다중화 구조 제어시스템에 대한 신뢰도 분석)

  • Noh, Jinpyo;Park, Jaehyun;Son, Kwang-Seop;Kim, Dong-Hoon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.4
    • /
    • pp.328-333
    • /
    • 2013
  • Since a slight malfunction of control systems in a nuclear power plant may cause huge catastrophes, such control systems usually have multiple redundancy and reliable features, and their reliability and availability should be analyzed and verified thoroughly. This paper performed the reliability analysis of the SPLC (Safety Programmable Logic Controller) that is under developed as the control systems for the next generation nuclear power plant. One of the key features of SPLC is that it has multiple redundancy modes as faults happen, which means the reliability analysis for one fixed redundant model is not enough to analyze the reliability of SPLC. With considering this reconfigurable concept, FTA (Fault Tree Analysis) was used to capture fault-relationship among sub-modules. The analysis results show that MTTF (Mean Time to Fault) of SPLC is 45,080 hours, which is a about 4.5 times longer than the regulation, 10,000 hours.

A Study of Drawing Policy Schemes to Establish Marine Clusters - Focused on Shipping Port Logistics Policy - (해양클러스터 구축을 위한 정책 방안 도출에 관한 연구 - 해운항만물류정책을 중심으로 -)

  • Gim, Jingoo;Jo, Jinhaeng;Paik, Jongsil
    • Journal of Korea Port Economic Association
    • /
    • v.29 no.2
    • /
    • pp.173-194
    • /
    • 2013
  • This paper aims at drawing policy schemes to establish marine clusters so as to enhance Korea's global port competitiveness and applying them to its national management for the advancement of national economy through policy suggestions. The research method is an integrated approach(IA) that comprises SWOT Method with strategic approaches, HFP Model enhanced by KJ Method and descriptive deductions. Strategic schemes established for the SPLC are followed by the group of geographical proximity, integration of ICT, expansion of the interchange of ICT & opportunities of ET, integration of ICT services with marine technologies, supply of integrated services in the SPLC and implementation of organizational policies. In order to make a specific implementation of strategic establishment schemes of the SPLC, we need to select a promotion entity. It is advised to establish the joint organization of the public sector and the private sector, which is considered most desirable. In practice, it is to be followed by promoting support schemes of the organizational policy on the level of national management. In order to reinforce this study, further compensative and proactive researches on the offshore sector with marine clusters are required in terms of the development of the high value added 'blue' ocean.

Voting System Bus Protocol for a Highly-Reliable PLC with Redundant Modules (다중화 구조 고신뢰성 제어기기를 위한 보팅 시스템버스 프로토콜)

  • Jeong, Woohyuk;Park, Jaehyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.6
    • /
    • pp.689-694
    • /
    • 2014
  • An SPLC (Safety Programmable Logic Controller) must be designed to meet the highest safety standards, IEEE 1E, and should guarantee a level of fault-tolerance and high-reliability that ensures complete error-free operation. In order to satisfy these criteria, I/O modules, communication modules, processor modules and bus modules of the SPLC have been configured in triple or dual modular redundancy. The redundant modules receive the same data to determine the final data by the voting logic. Currently, the processor of each rx module performs the voting by deciding on the final data. It is the intent of this paper to prove the improvement on the current system, and develop a voting system for multiple data on a system bus level. The new system bus protocol is implemented based on a TCN-MVB that is a deterministic network consisting of a master-slave structure. The test result shows that the suggested system is better than the present system in view of its high utilization and improved performance of data exchange and voting.

Combining Ego-centric Network Analysis and Dynamic Citation Network Analysis to Topic Modeling for Characterizing Research Trends (자아 중심 네트워크 분석과 동적 인용 네트워크를 활용한 토픽모델링 기반 연구동향 분석에 관한 연구)

  • Yu, So-Young
    • Journal of the Korean Society for information Management
    • /
    • v.32 no.1
    • /
    • pp.153-169
    • /
    • 2015
  • The combined approach of using ego-centric network analysis and dynamic citation network analysis for refining the result of LDA-based topic modeling was suggested and examined in this study. Tow datasets were constructed by collecting Web of Science bibliographic records of White LED and topic modeling was performed by setting a different number of topics on each dataset. The multi-assigned top keywords of each topic were re-assigned to one specific topic by applying an ego-centric network analysis algorithm. It was found that the topical cohesion of the result of topic modeling with the number of topic corresponding to the lowest value of perplexity to the dataset extracted by SPLC network analysis was the strongest with the best values of internal clustering evaluation indices. Furthermore, it demonstrates the possibility of developing the suggested approach as a method of multi-faceted research trend detection.

Development of Water Quality Management Model for Rural Area Using Decision Support System (의사결정지원기법을 이용한 농촌유역 수질관리모형의 개발)

  • 양영민;권순국
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.783-788
    • /
    • 1999
  • In this study, a decision support system (DSS) was developed to calculate optimal wastetreatment cost, treatment level and treatment quantity of various pollutants for applying for in rural basin. The DSS includes a gegraphic informatino system (GIS), relational database system (RDBS), water quality models(Loading function , WASP5), watershed pollution load calculation module(SPLC), optimal water quality management plan to satisfy the water quality regulations. The system can be modified by user to trace the optimal condition for decision. The effort was conducted to apply the developed DSS to select the for optimal water quality management plan small rural basin called Kwanri Stream.

  • PDF