• Title/Summary/Keyword: SPE1

Search Result 343, Processing Time 0.027 seconds

Muscle tissue Distribution Level of Ampicillin in Olive flounder(Paralichthys olivaceus), Rockfish(Sebastes schlegeli), and Red sea bream(Pagrus major) following oral administration (Ampicillin의 경구투여에 따른 양식 어류(넙치, 조피볼락, 참돔)의 근육조직내 잔류량의 변화)

  • Cho Yoon-Hee;Jung Won-Chul;Shin Yong-Woon;Kim Kyoung-Won;Ha Ji-Young;Heo Sung-Hyek;Kim Eui-Gyung;Chung Hee-Sik;Kang Seok-Joong;Choi Yu-Jeong;Kim Suk;Lee Hu-Jang
    • Journal of Veterinary Clinics
    • /
    • v.23 no.2
    • /
    • pp.164-168
    • /
    • 2006
  • The residue depletion of ampicillin was investigated in the olive flounder (Paralichthys olivaceus), rockfish (Sebastes schlegeli), and red sea bream (Pagrus major) after 5 days treatment with medicated feed at a dose of 100 mg/kg bw/day. Fishes were sampled for muscle on 1st, 2nd, 3rd, and 4th day after treatment. Ampicillin concentrations were determined by high performance liquid chromatography after SPE column extraction. The recovery rates of ampicillin in muscle samples ranged 94-98% and 83-88% for the concentration of 0.05 mg/kg and 0.1 mg/kg, respectively. Ampicillin concentrations detected on 1st day after treatment were 0.143, 0.138, and 0.187 mg/kg in the muscle of olive flounder, rockfish, and red sea bream, respectively. After a withdrawal of 3 days, muscle concentrations were 0.016, 0.012, and 0.021 mg/kg in the olive flounder, rockfish, and red sea bream, respectively. Ampicillin was not detectable in muscle samples on 4 days following withdrawal of the medicated feed. From results of the present study, a withdrawal period of ampicillin is proposed on 5 days after 5 days treatment with medicated feed at a dose of 100 mg/kg bw/day to avoid the presence of excessive residues of the edible muscles of olive flounder, rockfish, and red sea bream.

Development and Validation of the Analytical Method for Oxytetracycline in Agricultural Products using QuEChERS and LC-MS/MS (QuEChERS법 및 LC-MS/MS를 이용한 농산물 중 Oxytetracycline의 잔류시험법 개발 및 검증)

  • Cho, Sung Min;Do, Jung-Ah;Lee, Han Sol;Park, Ji-Su;Shin, Hye-Sun;Jang, Dong Eun;Cho, Myong-Shik;Jung, ong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.3
    • /
    • pp.227-234
    • /
    • 2019
  • An analytical method was developed for the determination of oxytetracycline in agricultural products using the QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method by liquid chromatography-tandem mass spectrometry (LC-MS/MS). After the samples were extracted with methanol, the extracts were adjusted to pH 4 by formic acid and sodium chloride was added to remove water. Dispersive solid phase extraction (d-SPE) cleanup was carried out using $MgSO_4$ (anhydrous magnesium sulfate), PSA (primary secondary amine), $C_{18}$ (octadecyl) and GCB (graphitized carbon black). The analytes were quantified and confirmed with LC-MS/MS using ESI (electrospray ionization) in positive ion MRM (multiple reaction monitoring) mode. The matrix-matched calibration curves were constructed using six levels ($0.001{\sim}0.25{\mu}g/mL$) and coefficient of determination ($r^2$) was above 0.99. Recovery results at three concentrations (LOQ, $10{\times}LOQ$, and $50{\times}LOQ$, n=5) were from 80.0 to 108.2% with relative standard deviations (RSDs) less than of 11.4%. For inter-laboratory validation, the average recovery was in the range of 83.5~103.2% and the coefficient of variation (CV) was below 14.1%. All results satisfied the criteria ranges requested in the Codex guidelines (CAC/GL 40-1993, 2003) and the Food Safety Evaluation Department guidelines (2016). The proposed analytical method was accurate, effective and sensitive for oxytetracycline determination in agricultural commodities. This study could be useful for safety management of oxytetracycline residues in agricultural products.

Development of Analytical Method for Fipronil and Fipronil-Sulfone in Animal Serum by LC-MS/MS (LC-MS/MS에 의한 동물 혈청 내 피프로닐 및 피프로닐 설폰 분석법 개발)

  • Lee, Jeongsun;Park, Na-Youn;Jung, Woong;Kho, Younglim
    • Journal of the Korean Chemical Society
    • /
    • v.63 no.6
    • /
    • pp.415-419
    • /
    • 2019
  • Fipronil is an insecticide that belongs to the N-phenylpytazole and has been used mainly for an insect pest control. However, it is known that acute poisoning of the human body causes various symptoms such as dizziness, muscle weakness, dyspnea, skin irritation, and increased heart rate. Lately, eggs containing fipronil have been distributed and toxic problems are spreading around the world. In this study, we tried to develop analytical methods to evaluate the exposure of fipronil and fipronil sulfone in animal serum samples. The differences according to mobile phase and the results of liquid - liquid extraction and solid phase extraction pretreatment method were compared. Distilled water (A) and acetonitrile (B) were selected for the mobile phase, and the pretreatment method was determined by solid phase extraction. As a result of the method validation, the intra-day / inter-day accuracies were 82.2~114.1% and the precisions were less than 20%. The detection limit was 0.027 ng/ml for fipronil and 0.087 ng/ml for fipronil sulfone. The linearity obtained was satisfying, with a coefficient of determination (r2) higher than 0.99. The concentrations in some animal sera were determined using the methods of analysis for fipronil and fipronil sulfone in animal sera developed in this study. Using the method developed in this study, it could be used as an analytical method for human bio-monitoring of fipronil and fipronil sulfone as well as animal serum.

Study on New Extraction Method of Microcystins from Cyanobacteria (남조류로부터 마이크로시스틴을 추출하는 새로운 추출법 연구)

  • Pyo, Dong Jin;Shin, Hyun Du
    • Journal of the Korean Chemical Society
    • /
    • v.45 no.2
    • /
    • pp.149-155
    • /
    • 2001
  • A new analytical method of cyanobacterial toxins, i, e, microcysins was deveeloped using supercritical fluid extraction(SFE). The microcystins mcluded in the study are sparsely soluble in neat supercritical fluid CO$_2$ However, the microcystins were successfully extracted with a temary mixture(90% CO$_2$,9.0% methanol 1.0% water) at 40$^{\circ}$C and 250 atm. The SFE method developed in this study has several advantages over solid-phase extraction(SPE) sample preparation for the analysis of microcystins. Sample handling steps are minimized thus reducing possible losses of analytes and saving analysis time. No clean-up steps are employed in this SFE method. Althouhgh many methods have been described for microcystim RR and LR, the method using solid-phase extraction with ODS cartridges is the most commonly used. However, the adsorbing power of ODS caridges for microcystins is weak, so we have attempted to use a more polar CN cartridge, to increase the adsorbing power for microcystins. Lyophilized cells(100mg) were wxtracted with 5% (v/v) acetic acid. The extract was centrifuged and then the supernatant was applied to a CN cartridge. The cartridge which contained microcystins was rinsed with 5 ml of water and 5 ml of 0.5 M acetic acid. followed by 5 ml of 5% acetonitrile in water , and were determined by HPLC. Better recoveries and chromatogram were observed than with ODS cartridge.

  • PDF

Composition and Structure Confirmation of Glucitol Fatty Acid Polyesters (Glucitol Fatty Acid Polyesters의 조성 및 구조확인)

  • Chung, Ha-Yull;Yoon, Hee-Nam;Kong, Un-Young;Kim, Jung-Han
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.148-153
    • /
    • 1993
  • Composition and structure of synthetic glucitol fatty acid polyesters (GPE)-a potential fat substitute-were investigated. Also degree of substitution (D.S) of GPE was determined according to the relative ester distribution within it to evaluate the feasibility of GPE using as a fat substitute. The GPE was separated into single ester group by a normal-phase HPLC and D.S of it was identified to be 6. Absorption band at $1747\;cm^{-1}$ in the IR spectrum of GPE indicated that there were ester bonds within GPE molecules. which link fatty acid moiety to glucitol. Disappearance of the hydroxyl proton signals of glucitol in the H-NMR spectrum of GPE implied that most of hydroxyl groups in glucitol participated in the formation of ester bonds with fatty acids. In addition the D.S estimated from the quantitative proton integration of GPE coincided well with the D.S of GPE determined by hydroxyl value measurement. In conclusion, the GPE synthesized in this study was found to be a glucitol fatty acid hexaester so that it is expected to be used as a fat substitute in the near future.

  • PDF

Development and Validation of an Analytical Method for Flutianil Residue Identification Using Gas Chromatography-Electron Capture Detection (GC-ECD를 이용한 flutianil 잔류량 분석법 개발 및 확인)

  • Kwon, Ji-Eun;Do, Jung-Ah;Park, Hyejin;Lee, Ji-Young;Cho, Yoon-Jae;Oh, Jae-Ho;Rhee, Gyu-Seek;Lee, Sang-Jae;Chang, Moon-Ik
    • Korean Journal of Food Science and Technology
    • /
    • v.46 no.1
    • /
    • pp.7-12
    • /
    • 2014
  • A sensitive and simple analytical method to identify flutianil residues in agricultural commodities was developed and validated using gas chromatography-electron capture detection (GC-ECD) and mass spectrometry (GC-MS). The flutianil residues were extracted with acetonitrile, partitioned with dichloromethane, and then purified using a silica solid-phase extraction (SPE) cartridge. The method was validated using pepper, sweet pepper, mandarin, hulled rice, soybean, and potato spiked with 0.02 or 0.2 mg/kg flutianil. The average recovery of flutianil was 76.5-108.0% with a relative standard deviation of less than 10%. The limit of detection and limit of quantification were 0.004 and 0.02 mg/kg, respectively. The result of recoveries and relative standard deviation were in line with Codex Alimentarius Commission Guidelines (CAC/GL 40). These results show that the method developed in this study is appropriate for flutianil identification and can be used to maintain the safety of agricultural products containing flutianil residues.

Determination of N-nitrosamines in Water by Gas Chromatography Coupled with Electron Impact Ionization Tandem Mass Spectrometry (EI-GC/MS/MS를 이용한 니트로사민류의 수질분석)

  • Lee, Ki-Chang;Park, Jae-Hyung;Lee, Wontae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.11
    • /
    • pp.764-770
    • /
    • 2014
  • This study assessed analysis of N-nitrosamines by separation, identification, and quantification using a gas chromatography (GC) mass spectrometer (MS) with electron impact (EI) mode. Samples were pretreated by a automated solid phase extraction (SPE) and a nitrogen concentration technique to detect low concentration ranges. The analysis results by EI-GC/MS (SIM) and EI-GC/MS/MS (MRM) on standard samples with no pretreatment exhibited similar results. On the other hand, the analysis of pretreated samples at low concentrations (i.e. ng/L levels) were not reliable with a EI-GC/MS due to the interferences from impurity peaks. The method detection limits of eight (8) N-nitrosamines by EI-GC/MS/MS analysis ranged from 0.76 to 2.09 ng/L, and the limits of quantification ranged from 2.41 to 6.65 ng/L. The precision and accuracy of the method were evaluated using spiked samples at concentrations of 10, 20 and 100 ng/L. The precision were 1.2~13.6%, and the accuracy were 80.4~121.8%. The $R^2$ of the calibration curves were greater than 0.999. The recovery rates for various environmental samples were evaluated with a surrogate material (NDPA-$d_{14}$) and ranged 86.2~122.3%. Thus, this method can be used to determine low (ng/L) levels of N-nitrosamines in water samples.

Comparison of isoButoxycarbonyl derivatives, tert.-butyldimethylsilyl derivatives, with US EPA Method in the sensitivity of Alkylphenols, Chlorophenols, and Bisphenol A Potential field-screening applications of GC/MS-SIM (기체 크로마토그래피/질량분석기를 이용한 field-screening 적용을 위한 알킬페놀류, 클로로페놀류 및 비스페놀 A의 isoBOC 유도체, TBDMS 유도체와 US EPA 방법의 비교)

  • Kim, Hyub;Hong, Jong-Ki;Kim, Yong-Hwa;Kim, Kyoung-Rae
    • Analytical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.196-213
    • /
    • 2002
  • The alkylphenols, chlorophenols and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring mode followed by three work-up methods for comparison; EPA method, isoBOC derivatization method and TBDMS derivatization method. Eleven phenols in water samples were extracted with dichloromethane. Also, solid-phase extraction (SPE) with XAD-4 and subsequent conversion to isobutoxycarbonyl derivatives or tert.-butyldimethylsilyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The recoveries were 85.1~109.9% (EPA method) and 90.3~126.6% (isoBOC derivatization and TBDMS derivatization), respectively. The method detection limit of bisphenol A for SIM were 0.732 ${\mu}g/{\ell}$ (EPA method), 0.002 ${\mu}g/{\ell}$ (isoBOC derivatization) and 0.021 ${\mu}g/{\ell}$ (TBDMS derivatization). The SIM responses were linear with the correlation coefficient varying 0.9755~0.9981 (isoBOC derivatization), and 0.9908~0.9996 (TBDMS derivatization). When these methods were applied to treated wastewater sample from a polyethylene plant, the concentrations of 11 phenols were below the method detection limit.

Determination of Neonicotinoid Pesticides in Commercial Agricultural Products by LC-MS/MS (LC-MS/MS를 이용한 농산물중 Neonicotinoid 계 농약분석)

  • Hwang, Lae-hong;Yang, Hye-ran;Lee, Jae-kyoo;Kim, Chang-kyu;Kim, Min-jung
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.4
    • /
    • pp.312-318
    • /
    • 2020
  • A method using liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for neonicotinoid pesticide analysis in agricultural products. Four compounds (imidacloprid, clothianidin, acetamiprid, thiacloprid) were extracted with acetonitrile from agricultural products and cleaned up by NH2 solid-phase extraction procedure, and eluted with 0.1% formic acid in methanol/dichloromethane (5/95, v/v). The limit of detection and quantification were 0.0001-0.0005 mg/kg and 0.001 mg/kg, respectively. The mean recoveries of neonicotinoid pesticide from agricultural products were in the range of 90.7-100.9% and 94.4-99.8%, as spiked at 0.2 mg/kg and 0.02 mg/kg, respectively. This validation satisfied the national criteria for pesticide analytical methods. In summary, The present method is fast, precise and sensitive enough for the Positive List System (PLS), and we conclude that the method is also suitable for neonicotinoid pesticide determination in a wide range of agricultural products.

Analysis of Methamphetamine and Amphetamine in Oral Fluid of Eleven Drug Abusers (마약남용자 11명의 타액 중 메스암페타민의 분석)

  • Kim, Eun-Mi;Lee, Ju-Seon;Choi, Hye-Young;Choi, Hwa-Kyung;Chung, Hee-Sun
    • YAKHAK HOEJI
    • /
    • v.52 no.6
    • /
    • pp.419-425
    • /
    • 2008
  • A qualitative and quantitative analytical method was developed for detection of methamphetamine (MA) and its main metabolite amphetamine (AM) in oral fluid. Oral fluids of eleven drug abusers were provided by Police, specimens were collected by stimulation with a cotton swab treated with 20 mg of citric acid ($Salivette^{(R)}$; Sarstedt, USA). As the preliminary test, oral fluid samples were screened for amphetamines by Fluorescence Polarization Immunoassay (TDxFLx, Abbott Co.). Extraction for MA was performed using solid-phase extraction (SPE) by $RapidTrace^{TM}$ (Zymark, USA) with mixed mode cation exchange cartridge, CLEAN $SCREEN^{(R)}$ (130 mg/3 ml, UCT) after dilution with phosphate buffer. Samples were evaporated and derivatized by pentafluoropropionic acid anhydride (PFPA). Quantitation of MA and AM was performed by gas chromatography-mass spectrometry (GC-MS) using selective ion monitoring (SIM), the quantitation ions were m/z 204 (MA), 208 (MA-$D_5$), 190 (AM) and 194 (AM-$D_5$). The selectivity, linearity of calibration, limit of detection (LOD) and quantification (LOQ) within- and between day precision, accuracy and recoveries were examined as parts of the method validation. All oral fluid samples gave positive results to immunoassay for MA (cut-off level, 50 ng/ml as d-amphetamine). Concentrations of MA and AM by GC-MS in eleven samples were ranged 104.2${\sim}$4603.3 ng/ml and 32.4${\sim}$268.6 ng/ml, respectively. Extracted calibration curves of MA and AM were linear over the two concentration range of 1${\sim}$100 and 50${\sim}$1000 ng/ml with correlation coefficient of above 0.999. LOQ of MA and AM was 1 and 3 ng/ml, respectively. The intraand inter-day run precisions (CV) for MA and AM were less than 10%, and the accuracies (bias) for MA and AM were also less than 10% at the two different concentrations 5 and 100 ng/ml at low calibration range, 50 and 1000 ng/ml at high calibration range. The absolute recoveries of MA and AM at low and high calibration ranges were more than 82% and 75%, respectively. In this study the qualitative and quantitative analytical method of MA in oral fluid was established. Oral fluid testing may detect drug use in past hours because of its shorter detection window than urine, and be useful in post-accident situations. So oral fluids will be most useful for testing drug abuse in the driving under the influence of drug (DUID) as the alternative specimens of urine.