• 제목/요약/키워드: SPE1

Search Result 343, Processing Time 0.027 seconds

The Probability of Solar Proton Events (SPEs) depending on solar and interplanetary type II bursts

  • Youn, Sae-Poom;Moon, Young-Jae;Park, Jin-Hye
    • Bulletin of the Korean Space Science Society
    • /
    • 2011.04a
    • /
    • pp.28.4-29
    • /
    • 2011
  • Solar Proton Events (SPEs, ${\geq}\;10\;cm^{-1}s^{-1}sr^{-1}$ with >10 MeV) are very important for space weather forecasting. It is well known that they are associated with solar flares and/or CME-driven shocks. Especially, the CME-driven shocks have been observed as solar and interplanetary type II bursts. In this study, we estimated the occurrence probability of SPEs depending on three groups: (1) metric, (2) decameter-hectometric (D-H), and (3) meter-to-kilometric (m-to-km) type II bursts. For this work, we used SPEs and all available type II burst data in 1996-2004. The primary findings of this study are as follows. First, the majority (77%) of the m-to-km type II bursts are associated with SPEs and its probability is noticeably higher than D-H type II bursts probability strongly depend on longitude: eastern (0%), center(45%), and western (33%) for X-class associated metric type II bursts, eastern (15%), center (55%), and western (50%) for X-class associated D-H type II bursts, eastern (17%), center (77%), and western (64%) for X-class associated m-to-km type II bursts. Third, for m-to-km type II bursts, the SPE probability increases with CME speed: 400km/s${\leq}$V <1000km/s (36%), 1000km/s ${\leq}$V<1500km/s (40%), 1500km/s${\leq}$V (66%). Finally, we expect that these results will be used for setting up more reasonable solar proton event forecasting models.

  • PDF

Isolation of Microcystin-LR and Its Potential Function of Ionophore

  • Kim, Gilhoon;Han, Seungwon;Won, Hoshik
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.19 no.2
    • /
    • pp.67-73
    • /
    • 2015
  • The microcystin is a cyclic heptapeptide from metabolites of cyanobacteria in the genera mycrocystis, anabaeba as a result of eutrophication. It has been known that microcystin-LR is a potent inhibitor of the catalytic subunits of protein phosphatase-1 (PP-1) as well as powerful tumor promoter. The active site of microcystin actually has two metal ions $Fe^{2+}/Zn^{2+}$ close to the nucleophilic portion of PP-1-microcystin complex. We report the isolation and purification of this microcystin-LR from cyanobacteria (blue-green algae) obtained from Daechung Dam in Chung-cheong Do, Korea. Microcystin-LR was extracted from solid-phase extraction (SPE) sample preparation using a CN cartridge. The cyanobacteria extract was purified to obtain microcystin-LR by HPLC method and identified by LC/MS. The detail structural studies that can elucidate the possible role of monovalent and divalent metal ions in PP-1-microcystin complexation were carried out by utilizing molecular dynamics. Conformational changes in metal binding for ligands were monitored by molecular dynamic computation and potential of mean force (PMF) using the method of the free energy perturbation. The microcystin-metal binding PMF simulation results exhibit that microcystin can have very stable binding free energy of -10.95 kcal/mol by adopting the $Mg^{2+}$ ion at broad geometrical distribution of $0.5{\sim}4.5{\AA}$, and show that the $K^+$ ion can form a stable metal complex rather than other monovalent alkali metal ions.

Multisample Extraction system for Solid Phase Extraction of Dissolved Organic Compounds from Sea Water (해수로부터 용존 윤기물의 Solid Phase Extraction을 위한 다수 시료 처리 장치)

  • Cho Ki Woong;Jung Kyungwha;Shin Jongheon;Kim Suk Hyun;Hong Gi-Hoon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.3 no.3
    • /
    • pp.34-40
    • /
    • 2000
  • A multisample extraction device was newly designed for efficient extraction of dissolved lipophillic organic compounds from sea water sample. This device allowed extraction of organic compounds from up to 96 sample at a time using 96 multifolder on the principle of solid phase extraction with commercially available octadecyl silane (ODS) cartridges. The recovery yield of the new divice was higher than 90 % while that of conventional liquid-liquid extraction process are only 60 - 70 %. The amount of solvent required for the new device could be reduced to less than 20㎖ per 1ℓ of sample while 1 - 2 ℓ of solvent were used in the conventional liquid-liquid extraction process. The usefulness of this novel method was demonstrated with sea water samples collected from Yellow sea, and the qualitative and quantitative analyses results of the dissolved hydrocarbon showed this method was superior to that of conventional liquid-liquid extraction process in efficiency and reliability.

  • PDF

Analysis of Phoxim Residue in Animal Food Production (Cattle and Pig) by LC/ESI-MS/MS (LC/ESI-MS/MS를 이용한 식육(소, 돼지)중 잔류 phoxim 분석)

  • Park, Mi-Sun;Lee, Jin-Joo;Myung, Seung-Woon
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.4
    • /
    • pp.626-632
    • /
    • 2011
  • Phoxim, which is one of veterinary drugs, is a well-known antiparasitic agent in wide use. In this paper, phoxim was extracted from cattle and pig tissue using solid-phase extraction (SPE) employing a silica cartridge with acetonitrile. Liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) for the analysis of phoxim from animal tissue was presented. Phoxim was detected on a $C_{18}$ column ($2.1{\times}100\;mm$, $3.5\;{\mu}m$) using a mobile phase of 0.1% formic acid in water and acetonitrile. A linear correlation observed in the calibration curves for cattle (0.0048~2.0 mg/kg) and pig (0.0055~2.0 mg/kg) showed above $r^2$=0.995. Accuracy measured at concentrations ranging from 0.0048 to 0.2 mg/kg was the range of 68.2~106.9%. Limit of detection (LOD) and limit of quantitation (LOQ) were the range of 0.0014~0.0017 mg/kg and 0.0048~0.0055 mg/kg, respectively. The precision (RSD%) was below 11.2%.

LC-MS Determination and Bioavailability Study of Imidapril Hydrochloride after the Oral Administration of Imidapril Tablets in Human Volunteers

  • Yun Ji Hye;Myung Ja Hye;Kim Hye Jin;Lee Sibeum;Park Jong-Sei;Kim Won;Lee Eun-Hee;Moon Cheol Jin;Hwang Sung-Joo
    • Archives of Pharmacal Research
    • /
    • v.28 no.4
    • /
    • pp.463-468
    • /
    • 2005
  • The purpose of the present study was to develop a standard protocol for imidapril hydrochloride bioequivalence testing. For this reason, a specific LC-MS method was developed and validated for the determination of imidapril in human plasma. A solid-phase extraction cartridge, $Sep-pak^{R}$ C18, was used to extract imidapril and ramipril (an internal standard) from deproteinized plasma. The compounds were separated using a XTerra $MS^{R}$?C18 column ($3.5 {\mu}m, 2.1\times150 mm$) and $acetonitrile-0.1\%$ formic acid (67:33, v/v) adjusted to pH 2.4 by 2 mmol/L ammonium formic acid, as mobile phase at 0.3 mL/min. Imidapril was detected as m/z 406 at a retention time of ca. 2.3 min, and ramipril as m/z 417 at ca. 3.6 min. The described method showed acceptable specificity, linearity from 0.5 to 100 ng/mL, precision (expressed as a relative standard deviation of less than $15\%$), accuracy, and stability. The plasma concentration-versus-time curves of eight healthy male volunteers administered a single dose of imidapril (10 mg), gave an $AUC_{12hr}$ of imidapril of $121.48\pm35.81 ng mL^{-1} h$, and $C_{max} and T_{max}$ values of $32.59\pm9.76 ng/mL and 1.75\pm0.27 h$. The developed method should be useful for the determination of imidapril in plasma with sufficient sensitivity and specificity in bioequivalence study.

Antigen Excess in Free Light Chain Assay U sing the Hitachi 7600 P-module Automatic Chemistry Analyzer (Hitachi 7600 p-모듈을 이용한 유리형경쇄 정량검사의 항원과잉역 반응)

  • Cha, Kyong-Ho;Kim, Sung-Hee;Song, Chang-Un;Sim, Yang-Bo;Chae, Hyo-Jin
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.41 no.4
    • /
    • pp.173-179
    • /
    • 2009
  • The analysis of serum free light chains (sFLCs) can improve the diagnosis and monitoring of multiple myeloma and other plasma cell dyscrasias. As with other immunoassays, sFLCstests are subject to potential antigen excess and heterophilic antibody interference. We describe 9 cases of sFLCs antigen excess in patients with multiple myeloma using the FreeliteTM Human Kappa and Lambda Free Kits (The Binding Site ltd., Birmingham, UK) and the Hitachi7600 P module turbidimetric system. A total of 1,247 consecutive samples from 250 patients with multiple myeloma were assayed for sFLCs from April to September, 2009. The samples were assayed using an initial dilution of 1 :5and subsequent dilutions of 1 :50 and 1: 100. The same samples were analyzed for the presence of monoclonal gammopathies using serum protein electrophoresis (SPE) and immunofixation electrophoresis (IFE). There were 9 samples (0.72%) of antigen excess with 3 cases of kappa (0.24%) and 6 cases of lambda (0.48%). These cases represents an example of antigen excess or "hook effect" using the serum free light chain assays and mandates high level of attention to falsely low sFLC levels due to antigen excess, especially when it is disaccordant to other assay results or clinical manifestations.

  • PDF

Dependence of solar proton events on their associated activities: CME parameters

  • Park, Jin-Hye;Moon, Yong-Jae
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.39.2-39.2
    • /
    • 2011
  • In this study we have examined the occurrence probability of solar proton events (SEPs) and their peak fluxes depending two CME parameters, linear speed and angular width. For this we used the NOAA SPE events and their associated CME data from 1997 to 2006. As a result, the probability strongly depends on two parameters as follows. In the case of halo CME whose speed is equal to and faster than 1500km/s, 36.1% are associated with SPEs but in the case of partial halo CME ($120^{\circ}{\leq}AW$ < $359^{\circ}$) whose speed is $400{\leq}V$ < $1000km/s$, only 0.9% are associated with SPEs. When we consider only front-side CMEs, 45.3% are associated with SPEs in the first case and 1.8% are associated with them in the second case. Both of whole CME data group and front-side CME data group have similar tendencies. The probabilities are different as much as 4.9 to 23 times according to the CME speed and 1.6 to 6.5 times to the angular width. We have also examined the relationship between CME speed and proton peak flux as well as its dependence on angular width (partial halo CME and halo CME), longitude (east, center, and west) and direction parameter (< 0.4 and {\geq} 0.4). Our results show that the relationships strongly depend on longitude as well as direction parameter. In addition, the relationship using the radial CME speed based on a cone model has a higher correlation coefficient than that using the projected CME speed.

  • PDF

Analysis and Exposure Assessment of Perchlorate in Korean Dairy Products with LC-MS/MS

  • Oh, Sung-Hee;Lee, Ji-Woo;Mandy, Pawlas;Oh, Jeong-Eun
    • Environmental Analysis Health and Toxicology
    • /
    • v.26
    • /
    • pp.12.1-12.7
    • /
    • 2011
  • Objectives: Perchlorate is an emerging contaminant that is found everywhere, including various foods. Perchlorate is known to disturb the production of thyroid hormones and leads to mental disorders in fetuses and infants, as well as metabolic problems in adults. In this study, we attempted to establish an LC-MS/MS method for measuring perchlorate in dairy products and used this developed method to investigate perchlorate levels in Korean milk and yogurt samples. Methods: The developed method of perchlorate analysis requires a shaker and 1% acetic acid/acetonitrile as the extracting solvent. Briefly, the samples were extracted and then centrifuged (4000 rpm, 1hour), and the supernatant was then passed through a $Envi^{TM}$ Carb SPE cartridge that had been prewashed sequentially with 6 mL of acetonitrile and 6 mL of 1% acetic acid in water. The final volume of the sample extract was adjusted to 40 mL with reagent water and the final sample was filtered through a 0.20-${\mu}m$ pore size PTFE (Polytetrafluoroethylene) syringe filter prior to LC-MS/MS. Results: The average levels of perchlorate in milk and yogurt samples were $5.63{\pm}3.49\;{\mu}g/L$ and $3.65{\pm}2.42\;{\mu}g/L$, respectively. The perchlorate levels observed in milk samples in this study were similar to those reported from China, Japan, and the United States. Conclusions: The exposure of Koreans to perchlorate through the consumption of dairy products was calculated based on the results of this study. For all age groups, the calculated exposure to perchlorate was below the reference of dose (0.7 ${\mu}g/kg$-day) proposed by the National Academy of Science, USA, but the perchlorate exposure of children was higher than that of adults. Therefore, further investigation of perchlorate in other food samples is needed to enable a more exact assessment of exposure of children to perchlorate.

Determination of Dimethyl Disulfide, Diallyl Disulfide, and Diallyl Trisulfide in Biopesticides Containing Allium Sativum Extract by Gas Chromatography

  • Lim, Sung-Jin;Lee, Ji-Hye;Kim, Jin-Hyo;Cho, Geun-Hyoung;Cho, Nam-Jun;Park, Byung-Jun
    • Korean Journal of Environmental Agriculture
    • /
    • v.33 no.4
    • /
    • pp.381-387
    • /
    • 2014
  • BACKGROUND: Garlic (Allium sativum) extract has been allowed as commercial biopesticide material for pesticidal activity in the Environmentally-friendly Agriculture Promotion Act. Nine commercial biopesticides containing A. sativum extract have been marketed in Korea. However, the analytical method of the active substances in these materials has not been studied. METHODS AND RESULTS: Cartridge clean-up method for the determination of dimethyl disulfide(DMDS), diallyl disulfide(DADS), and diallyl trisulfide(DATS) in biopesticides containing A. sativum extract was developed and validated by gas chromatography(GC). The clean-up method was optimized using hydrophilic lipophilic balance (HLB) solid phase extraction(SPE) cartridges for the bioactive sulfides in biopesticides containing A. sativum extract, and the eluate was analyzed to quantify the DMDS, DADS, and DATS using the GC. The developed method was validated, and the LOQ and recovery rates of DMDS, DADS, and DATS were 0.226, 0.063, and $0.051mg\;L^{-1}$ and 80.6, 84.8, and 73.1%, respectively. From the nine commercial biopesticide samples, contents of DMDS, DADS, and DATS were analyzed using the developed method and results showed $2.3mg\;L^{-1}$, respectively. CONCLUSION: The developed method could be used in determining the quality of biopesticides for the manufacture of commercial biopesticides containing A. sativum extract.

Molecular Cloning of Two cDNAs Encoding an Insecticidal Toxin from the Spider, Araneus ventricosus, and Construction of a Recombinant Baculovirus Expressing a Spider Toxin

  • Chung, Eun-Hwa;Lee, Kwang-Sik;Han, Ji-Hee;Je, Yeon-Ho;Chang, Jin-Hee;Roh, Jong-Yul
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.4 no.1
    • /
    • pp.43-49
    • /
    • 2002
  • We have cloned cDNAs encoding toxin from the spider, Araneus ventricosus, and constructed a recombinant baculovirus expressing the insecticidal toxin. The cDNAs encoding toxin were cloned from the cDNA library of A. ventricosus. Sequence analysis of the cDNAs encoding the toxin of A. ventricosus revealed that the 240 bp cDNA for AvTox-1 and 192 bp cDNA for AvTox-2 have an open reading frame of 80 and 64 amino acid residues, respectively. The deduced protein sequence of the toxin genes of AvTox-1 and AvTox-2 was aligned to that of the snack Anemonia sulcata and scorpion Centruroides limpidus limpidus, respectively. Northern blot analysis indicated that AvTox-2 toxin gene showed a fat body-spe-cific expression pattern at the transcriptional level. Furthermore, we have explored the possibility of improving baculovirus by incorporating the A. vontricosus toxin gene into Bombyx mori nuclear polyhedrosis virus genome under the control of polyhedrin promoter, The AvTox-2 toxin gene was expressed as approximately 5.8 kDa band in the recombinant baculovirus-injected silkworm larvae. Bioassays with the recombinant virus expressing AvTox-2 on 5th instar silkworm larvae demonstrated a decrease in the time to kill $(LT_{50} days)$ compared to wild-type BmNPV-Kl $(LT_{50} 6.72 days)$ in the injection of 10 viruses. These results indicate that A. ventricosus toxin is a novel member of the spider toxin family, suggesting that the toxin gene can be used in recombinant baculoviruses to reduce insect feeding damage and increase the speed of insect kill.