• Title/Summary/Keyword: SONG METER

Search Result 160, Processing Time 0.039 seconds

A Study About the Application Feasibility of EMS IEC 61000-4-6 Test Standard on Electronic Power Meter (전자식 계기 IEC 61000-4-6 EMS 시험표준 적용 타당성 연구)

  • Kim, Seok-Gon;Park, Chang-Ho;Shin, Dong-Yeol;Song, Tae-Seung;Choi, Yong-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1261-1267
    • /
    • 2011
  • Electricity meters using in Korea are about 1.8 million units. From among these, electronic meters for high voltage, about 170 thousand units were installed to the digital type meter and ones for low voltage installed hundreds of thou-sands of meters through a model project. Recently, low voltage meter are expected to complete the installation within several years. Domestic power metering technology is being beyond a simple framework with an electronic type and is rapidly evolving to intelligent smart metering systems in conjunction with promotion of a national smart grid project. Accordingly, it is important to ensure an immunity of meter for electromagnetic field and environmental noise at the installation site. In this paper, we are going to check the validity of international standard that focusing on RF electromagnetic field immunity of meter to secure the quality and improve the reliability in field operation of meter. And we will verify the validity of test specification focused on actual installation environment and are going to offer the improvement plan of test standard.

The speed reducer of torque meter type with damping (Damping을 갖는 토크미터형 감속기)

  • Song, Chang-Hun;Lee, Woo-Min;Oh, Se-Hoon;Lee, Chong-Won
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.471-475
    • /
    • 2001
  • Planetary Speed Reducer consists of a sun gear, a planetary gear and a ring gear and if one element is fixed at this Speed Reducer, another elements operate to become a drive-axis and a subordination-axis respectively. Planetary Speed Reducer is frequently used for gear Speed Reducer because it has the advantage of having the high efficiency and getting the high Speed Reducer ratio in small space. However, it is difficult to know the current transmitted torque immediately during the use of Speed Reducer and so complicated equipment is installed in addition to protect the overload of system. The object of this paper is to design the Speed Reducer of torque- meter type that can know the torque transmitted using the power transmission feature of a simple Planetary Speed Reducer fixed at ring gear.

  • PDF

A Study on Design of Meter Data Management System for Operation of AMI (AMI 운영을 위한 MDMS 설계 연구)

  • Jung, Nam-Joon;Kim, Dong-Wook;Song, Jae-Ju;Chae, Chang-Hun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.04a
    • /
    • pp.208-211
    • /
    • 2012
  • 전력시스템에서 MDMS(Meter Data Management System)는 HAN(Home Area Network)과 Smart Meter, SUN(Smart energy Utility Network)와 같은 AMI(Advanced Metering Infrastructure) 기반 환경에서 수많은 전력 또는 수도 가스 사용량과 같은 데이터를 수집, 취득하고, 이들 데이터를 처리, 가공, 분석하여 가치 있는 정보로 변환시켜, 요금서비스 및 다양한 부가서비스 창출에 활용되는 소프트웨어 인프라이다. 최근 MDMS 개발은 기능의 중요성 뿐만 아니라 다른 응용 시스템들과의 상호 운용성을 고려하여 개발하는 요구 기능을 가진다. 본 논문에서는 스마트그리드 환경에 적합한 AMI의 전력처리시스템(MDMS) 개발을 위한 설계 방안을 기술하였다.

Development of Wave Monitoring System using Precise Point Positioning (PPP 기반 항법 알고리즘을 이용한 파고 계측시스템 설계 및 구현)

  • Song, Se Phil;Cho, Deuk Jae;Park, Sul Gee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.5
    • /
    • pp.1055-1062
    • /
    • 2015
  • A GPS based wave height meter system is proposed in this paper. The proposed system uses a dual-frequency measurements, a precise GPS satellite information and a PPP-based navigation algorithm to estimate the position with high accuracy. This method does not need to receive corrections from the reference stations. Therefore, unlike RTK based wave meter, regardless of the distance to the reference stations, it is possible to estimate position with high accuracy. This system is very simple and accurate system, but accelerometer-based system requires the other sensors such as GPS. Because position error is accumulated in the accelerometer system and must be removed periodically for high accuracy. In order to get the measurements and test the proposed wave height meter system, a buoy equipped with the test platform is installed on the sea near by Jukbyeon habor in Uljin, Korea. Then, to evaluate the performance, compares built-in commercial wave height meter with proposed system.

Development and Application of Slime Meter for Evaluation of Slime Thickness in Borehole (굴착공 내 슬라임 두께 평가를 위한 슬라임미터의 개발 및 적용)

  • Hong, Won-Taek;Woo, Gyuseong;Lee, Jong-Sub;Song, Myung Jun;Lim, Daesung;Park, Min-Chul
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.10
    • /
    • pp.29-38
    • /
    • 2018
  • The slime formed at the bottom of the borehole causes the excessive displacement and loss of the bearing capacity of the drilled shaft. In this study, the slime meter is developed for the evaluation of the slime based on the electrical properties of the fluid and the slime in the borehole. The slime meter is composed of a probe instrumented with electrodes and temperature sensor and a frame with rotary encoder, so that the slime meter profiles the electrical resistivity compensated with temperature effect along the depth. For the application of the slime meter, three field tests are conducted at a borehole with a diameter of 3 m and a depth of 46.9 m with different testing time and locations. For all the tests, the experimental results show that while electrical resistivities are constantly measured in the fluid, the electrical resistivities sharply increase at the surface of the slime. Therefore, the slime thicknesses are estimated by the differences in the depths of the slime surface and the ground excavation. The experimental results obtained at the same testing point with different testing time show that the estimated thickness of the slime increases by the elapsed time. Also, the estimated slime at the side of the borehole is thicker than that at the center of the borehole. As the slime meter estimates the slime in the borehole by measuring the electrical resistivity with simple equipment, the slime meter may be effectively used for the evaluation of the slime formed at the bottom of the borehole.

Meter-long coated conductor by R2R PVD methods on RABiTS template

  • Ko, Rock-Kil;Kim, Ho-Sup;Ha, Hong-Soo;Chung, Jun-Ki;Yang, Joo-Saing;Park, Yu-Mi;Shi, Dong-Qi;Song, Kyu-Jeong;Park, Chan;Yoo, Sang-Im;Moon, Seung-Hyun;Kim, Young-Cheol
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.4
    • /
    • pp.13-16
    • /
    • 2004
  • Three film deposition systems (pulsed laser deposition, sputtering, and evaporation) equipped with reel-to-reel metal tape moving apparatus were installed and used to make meter-long coated conductor. Buffer architecture of $CeO_2/YSZ/Y_2O_3$ was deposited on Ni alloy using sputtering, evaporation, and PLD. YBCO superconducting layer was continuously deposited on buffered metal tape by PLD. End-to-end critical current ($I_c$) of 107 A at 77 K, self-field has been achieved in 1 em-wide tape (thickness 0.6∼1.0${\mu}{\textrm}{m}$, tape moving speed 54∼72 cm/hr) over 1 meter length.

Application of the Velocity Index Method for Discharge Computation in Tidal River Basin (감조하천의 유량산정을 위한 유속지수법의 적용)

  • Song, Jae-Hyun;Lee, Suk-Ho;Kim, Chi-Young;Lee, Jin-Won;Jung, Sung-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1342-1345
    • /
    • 2009
  • 조위영향을 받는 감조하천에서는 조위변화의 주기적인 특성으로 인해 일반적인 수위와 유량의 관계가 성립하기 어렵기 때문에 최근 ADVM(Acoustic Doppler Velocity Meter) 또는 UVM (Ultrasonic Velocity Meter)과 같은 자동 유량측정 기법을 통한 연속유량측정이 이루어지고 있다. 한강대교 수위관측소는 대표적인 감조구간으로 이러한 문제를 해결하기 위해 ADVM 방식의 자동유량측정시설이 설치되어 운영 중에 있으며, H-ADCP 센서를 통해 측정된 유속을 Chiou의 무차원단면유속분포법을 이용하여 유량을 계산한다. 이는 최대유속을 유량산정의 지표로 하여 유량을 계산하는 방법으로, 본 연구에서는 한강대교 자동유량측정시설의 측정성과를 이용하여 유속지수법과 무차원유속분포법에 의해 산정된 유량을 비교하였고, 앞의 방법들을 검증하기 위하여 2008년 ADVM을 이용한 이동보트법으로 측정된 유량과 비교하였다.

  • PDF

The field-test of Power Quality Meter and Power Management System in order to verify the performance (PQM 및 PQMS 성능검증을 위한 실증시험)

  • Choi, Sun-Kyu;Song, Il-Keun;Kwon, Tae-Ho;Han, Jae-Wook
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.235-239
    • /
    • 2005
  • This paper gives a field-test method and result of PQM(Power Quality Meter) and PQMS(Power Quality Management System). The field-test was carried out as our own method. So, the test method has several kinds of improvement in this paper because it is first time to try the field-test of the equipment. However, we expect that the test result of PQM & PQMS has been used as a reference data which makes a scheme of evaluating performance of the equipment that has been used or is developed.

  • PDF