• Title/Summary/Keyword: SOFT X-RAY

Search Result 407, Processing Time 0.038 seconds

Introduction to Qunatification of Damage Parameters for Concrete Using X-ray Computed Tomography (X-ray Computed Tomography를 이용한 콘크리트의 손상파라미터 정량화)

  • 박대효;박재민;안태송
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.501-504
    • /
    • 2003
  • The purpose of this work is to introduce some fundamental stereological concepts to quantify damage parameters using X-ray CT(Computed Tomography) in the scope of CDM(Continuum Damage Mechanics). X-ray CT is a completely nondestructive technique for visualizing features in the interior of opaque solid objects, and for obtaining digital information on their 3D geometries and properties. Many researchers have introduced lots of damage parameters to model the mechanical behavior of deteriorated materials. Those damage parameters can be represented in many forms such as specific void or crack surfaces, the spacing between cracks, the specific damaged surface area, the specific damaged surface area tensor, the mean solid path among the damaged surfaces and the mean solid path tensor. Despite of many accomplishments in CDM since there is no the systematic experiment, it have limitations in application. In this situation, X-ray computed tomography is highlited by many researchers and applied in a wide range of materials including rock, bone, ceramic, metal, soft tissue and concrete.

  • PDF

Design of a specimen holder for living cell in the soft X-ray microscopy (연 X-선 현미경을 위한 생체시료 고정장치 설계)

  • 권영만;김경우;윤권하
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.705-708
    • /
    • 2003
  • To observe a hydrated biological specimen, an environmental chamber was necessary to keep the specimen in a wet state under vacuum surroundings. The specimen holder is as follows designed consequently. The specimen holder consisted of two Si wafers, the centers of which were Si$_3$N$_4$(100nm thickness) windows of a 0.3mm square. The windows were made by a photo-lithographic method. The transmission of a window at 400eV is about 70%. A hydrated biological specimen was put between the two windows. When the chamber was closed, two wafers were contact at the metal mesh by the pressure of O-rings, and the specimen holder moved by the three micrometers.

  • PDF

Soft x-ray Synchrotron Radiation Spectroscopy Study of Molecule-based Nano Bioparticles Containing Fe (철원소를 함유한 분자기반 생체물질 나노입자들의 연 x선 방사광 분광 연구)

  • Lee, Eun-Sook;Kim, D.H.;Hwang, Ji-Hoon;Lee, Ki-Ho;Kang, J.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.4
    • /
    • pp.125-129
    • /
    • 2012
  • By employing soft x-ray absorption spectroscopy (XAS) and soft x-ray magnetic circular dichroism (XMCD), the electronic structures of molecule-based nano bioparticles, such as Helicobacter pylori ferritin (H. pylori ferritin), Heme, $NaM[Fe(CN)_6]{\cdot}H_2O$-type Prussian Blue (M=Co, Ni) analogue, have been investigated. The measured Fe 2p XAS spectra reveal that Fe ions are trivalent ($Fe^{3+}$) in H. pylori ferritins, while they are in the $Fe^{2+}-Fe^{3+}$ mixed-valent states in $NaM[Fe(CN)_6]{\cdot}H_2O$ Prussian Blue analogues (M=Co, Ni). According to the Fe 2p XMCD spectrum of high-state H. pylori ferritin, all the $Fe^{3+}$ ions have the same local symmetry and their magnetic moments are aligned in the same direction. It is also found that the Fe 3d orbitals in $NaM[Fe(CN)_6]{\cdot}H_2O$ have a strong covalent bonding to $(CN)^-$ ligands, but with a very weak bonding to the 2p orbitals of O ligands.

Image System Using Dual Energy Detector (이중 에너지 검출기를 이용한 영상 시스템)

  • Yeo, Hwa-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3517-3523
    • /
    • 2010
  • Single exposure dual X-ray imaging can be used to separate soft and dense-material images for medical and industrial applications. This study keep focusing baggage inspection system(BIS) specifically. New detector modules for single exposure dual X-ray imaging are consisted of low energy detector (LED) and high energy detector (HED). First, the optimized thickness of copper filter coupled HED to separate low energy and high energy was simulated by the given X-ray energy (140 kVp, 1 mA) using Monte Carlo simulation codes, MCNPX. So as a result of simulation, the copper filter thickness is 0.7 mm. For the design of PIN photodiode, ATLAS device simulation tool was used. 16 channels PIN photodiode of 1.5 mm ${\times}$ 3.2 mm for Dual X-ray imaging detector was fabricated in the process of ETRI. And its dark current and quantum efficiency, terminal capacitance were measured. It was proven that the Lanex Fast B coupled HED were a sufficient candidate to replace the CsI(Tl) commerced in dual X-ray system, since these give a strong signal, overcoming system noise. Finally dual X-ray image was acquired through correction of the LED X-ray Image and the HED X-ray Image.

LATEST RESULTS OF THE MAXI MISSION

  • MIHARA, TATEHIRO
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.559-563
    • /
    • 2015
  • Monitor of All-sky X-ray Image (MAXI) is a Japanese X-ray all-sky surveyer mounted on the International Space Station (ISS). It has been scanning the whole sky since 2009 during every 92-minute ISS rotation. X-ray transients are quickly found by the real-time nova-search program. As a result, MAXI has issued 133 Astronomer's Telegrams and 44 Gamma-ray burst Coordinated Networks so far. MAXI has discovered six new black holes (BH) in 4.5 years. Long-term behaviors of the MAXI BHs can be classified into two types by their outbursts; a fast-rise exponential-decay type and a fast-rise flat-top one. The slit camera is suitable for accumulating data over a long time. MAXI issued a 37-month catalog containing 500 sources above a ~0.6 mCrab detection limit at 4-10 keV in the region ${\mid}{b}{\mid}$ > $10^{\circ}$. The SSC instrument utilizing an X-ray CCD has detected diffuse soft X-rays extending over a large solid angle, such as the Cygnus super bubble. MAXI/SSC has also detcted a Ne emission line from the rapid soft X-ray nova MAXI J0158-744. The overall shapes of outbursts in Be X-ray binaries (BeXRB) are precisely observed with MAXI/GSC. BeXRB have two kinds of outbursts, a normal outburst and a giant one. The peak dates of the subsequent giant outbursts of A0535+26 repeated with a different period than the orbital one. The Be stellar disk is considered to either have a precession motion or a distorted shape. The long-term behaviors of low-mass X-ray binaries (LMXB) containing weakly magnetized neutron stars are investigated. Transient LMXBs (Aql X-1 and 4U 1608-52) repeated outbursts every 200-1000 days, which is understood by the limit-cycle of hydrogen ionization states in the outer accretion disk. A third state (very dim state) in Aql X-1 and 4U 1608-52 was interpreted as the propeller effect in the unified picture of LMXB. Cir X-1 is a peculiar source in the sense that its long-term behavior is not like typical LMXBs. The luminosity sometimes decreases suddenly at periastron. It might be explained by the stripping of the outer accretion disk by a clumpy stellar wind. MAXI observed 64 large flares from 22 active stars (RS CVns, dMe stars, Argol types, young stellar objects) over 4 years. The total energies are $10^{34}-10^{36}$ erg $s^{-1}$. Since MAXI can measure the spectrum (temperature and emission measure), we can estimate the size of the plasma and the magnetic fields. The size sometimes exceeds the size of the star. The magnetic field is in the range of 10-100 gauss, which is a typical value for solar flares.

Synthesis of Cobalt-Iron Prussian Blue Analogues Nanotubes by CTAB Soft-Template Method

  • Liu, Peng;Liang, Chuanghui;Xu, Jianfeng;Fang, Jian;Zhao, Jihua;Shen, Weiguo
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1336-1338
    • /
    • 2010
  • Three cobalt-iron Prussian Blue Analogues (PBAs) nanotubes contained with different alkali metal cations of K, Rb or Cs, respectively, were prepared by using cetyltrimethylammonium bromide (CTAB)/ethanol-water micelles as soft templates. The products were characterized by energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), transmission electron microscopy (TEM) and scanning electron micrograph (SEM), which confirmed the composition of the substances and their unique nanotube structures. Furthermore, the formation mechanism of the PBAs nanotubes was discussed and provided useful insight for further synthesis of nanotubes of other Prussian blue analogues.

MONTE CARLO SIMULATION OF COMPTONIZATION IN A SPHERICAL SHELL GEOMETRY

  • SEON KWANG IL;MIN KYOUNG WOOK;CHOI CHUL SUNG;NAM UK WON
    • Journal of The Korean Astronomical Society
    • /
    • v.27 no.1
    • /
    • pp.45-53
    • /
    • 1994
  • We present the calculation of X -ray spectra produced through Compton scattering of soft X-rays by hot electrons in the spherical shell geometry, using fully relativistic Monte Carlo simulation. With this model, we show that the power-law component, which has been observed in the low luminosity state of low-mass X-ray binaries (LMXBs), is explained physically. From a spectral. analysis, we find that spectral hardness is mainly due to the relative contribution of scattered component. In addition, we see that Wi en spectral features appear when the plasma is optically thick, especially in the high energy range, $E{\gtrsim}100keV$. We suggest that after a number of scattering the escape probability approaches an asymptotic form depending on the geometry of the scattering medium rather than on the initial photon spectrum.

  • PDF

Development of Portable X-ray CT System I - Evaluation of Wood Density using X-ray Radiography - (현장 적용이 가능한 X선 CT 시스템 개발 I - X선 촬영법을 이용한 목재의 밀도 측정 -)

  • Kim, Kwang-Mo;Lee, Sang-Joon;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.15-22
    • /
    • 2006
  • ln order to manage efficiently many ancient wooden buildings, which have been preserved as cultural properties in Korea, the internal state of wood members should be evaluated exactly and periodically by a NDE (non-destructive evaluation) method. A research project was planned to develop an X-ray CT (computed tomography) system as a NDE method for wood, which could be easily applied in field. This paper includes the first part of this project. First of all, to establish a measuring procedure of wood density using X-ray radiography, the correlation between X-ray intensity and the film brightness was evaluated. Also, initial X-ray intensity was quantified with various radiate conditions controlled by the tube voltage and tube current. And then, the effects of density, annual ring angle, and thickness on the mass attenuation coefficient of wood were examined. Finally, Beer's law was modified with the above results and adopted to calculate the density of wood. As a result of this study, the measuring procedure of wood density was established using a portable soft X-ray device and this procedure was verified with some small wood specimens. This results will he used valuably for the following researches to develop a portable X-ray CT system.

Evaluation of imaging reformation with cone beam computed tomography for the assessment of bone density and shape in mandible (Cone beam형 전산화단층영상에서 골의 형태와 밀도의 평가)

  • Hong, Sang-Woo;Kim, Gyu-Tae;Choi, Yon-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.38 no.1
    • /
    • pp.49-56
    • /
    • 2008
  • Purpose: Diagnostic estimation of destruction and formation of bone has the typical limit according to capacity of x-ray generator and image detector. So the aim of this study was to find out how much it can reproduce the shape and the density of bone in the case of using recently developed dental type of cone beam computed tomography, and which image is applied by new detector and mathematic calculation. Materials and Methods: Cone beam computed tomography (PSR 9000N, Asahi Roentgen Ind. Co., Ltd., Japan) and soft x-ray radiography were executed on dry mandible that was already decalcified during 5 hours, 10 hours, 15 hours, 20 hours, and 25 hours. Estimating and comparing of those came to the following results. Results: The change of inferior border of mandible and anterior border of ramus in the region of cortical bone was observed between first 5 and 10 hours of decalcification. The reproduction of shape and density in the region of cortical bone and cancellous bone can be hardly observed at cone beam computed tomography compared with soft x-ray radiography. The difference of decrease of bone density according to hours of decalcification increase wasn't reproduced at cone beam computed tomography compared with soft x-ray radiography. Conclusion: CBCT images revealed higher spatial resolution. However, contrast resolution in region of low contrast sensitivity is the inferiority of images' property.

  • PDF

Fabrication of X-ray monocapillary optics for soft X-ray fluorescence analysis (경 X선 형광분석을 위한 모세관 광학소자 제작)

  • Cho, Hyung-Wook;Park, Byung-Hoon;Kim, Yong-Min;Choi, Chul-Hee;Choi, Seong-Hee;Kim, Ki-Hong;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.409-413
    • /
    • 2011
  • An X-ray tube used an X-ray fluorescence analysis system has a low X-ray photon intensity which results in reducing measurement accuracy and increasing exposure time. These shortages can be overcame by using a monocapillary optics. A monocapillary optics was optimally designed for focusing the characteristic X-ray of tungsten (8.4 keV). The monocapillary optics can achieve a gain of 10 at the least. The monocapillary optics was fabricated by using puller and pyrex glass, raw material. In fabrication, a weigh of 45g and a temperature of $650^{\circ}$ was loaded. The total fabrication time was 460 minutes. The fabricated capillary had 87 mm in length and maximum diameter of 300 ${\mu}m$ and minimum diameter of 192 ${\mu}m$. When the fabricated monocapillary optics is applied to an X-ray fluorescence analysis system, the detection accuracy for soft elements, for example sulfur (S), will be improved.