• Title/Summary/Keyword: SNR control

검색결과 190건 처리시간 0.027초

Radio Resource Sharing using Power Control of Base-station in Cognitive Radio System (코그니티브 라디오 시스템에서의 전력 제어를 이용한 무선 자원 공유)

  • Kwon, Yang-Soo;Ji, Young-Geun;Chung, Jae-Hak
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제32권10A호
    • /
    • pp.1057-1064
    • /
    • 2007
  • Cognitive radio(CR) technique which utilizes empty frequency bands allocated to private business but not being used temporally has been researched. According to the standard, CR users detect the primary user using the same channel, CR users should move to the another channel to guarantee the primary user's decodability. Thus, CR systems cannot use the same channel and support the CR user's QoS(Quality of Service) during the channel moving time. In this paper, we propose a radio resource sharing method that CR basestation controls the transmission power with the primary user's SNR(Signal to Noise Ratio) to increase the spectral efficiency of area and to minimize the outage of CR users. In addition, computer simulation demonstrates show that the proposed method improved spectral efficiency of area and decreased outage probability of CR users.

Design and Analysis of Transmission Parameters for DH(Dog-Horse) Systems Based on IEEE802.16e (WiBro) (견마로봇 시스템의 상향링크 고속신호 전송을 위한 시스템 WiBro(IEEE802.16e) 통신변수 설계 및 분석)

  • Lee, Il-Shin;Yoo, Jae-Ho;Lee, Yoon-Ju;Kwon, Dong-Seung;Chung, Jae-Hak
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • 제45권6호
    • /
    • pp.1-9
    • /
    • 2008
  • This paper presents transmission parameters of DH(Dog-Horse) systems based on IEEE802.16e(WiBro) systems. DH requires higher uplink multimedia data rate, which is different from commercial WiBro systems. This paper designes some transmission parameters satisfying the DH system requirements and demonstrates link performance evaluation based on the parameters. For the transmission parameters, the number dwon/up link OFDM symbols are determined by 6/30, respectively. For reliable transmission of control signals, downlink modulation and coding rate are selected by QPSK, 1/2 coding rate and that of uplink is chosen by 16QAM 1/2 and 3/4 coding rate. Based on these parameters, computer simulations demonstrate the system performance of DH system.

Analysis of QRS-wave Using Wavelet Transform of Electrocardiogram (웨이블릿 변환을 이용한 심전도의 QRS파 신호 분석)

  • Choi, Chang-Hyun;Kim, Yong-Joo;Kim, Tae-Hyeong;Ahn, Yong-Hee;Shin, Dong-Ryeol
    • Journal of Biosystems Engineering
    • /
    • 제33권5호
    • /
    • pp.317-325
    • /
    • 2008
  • The electrocardiogram (ECG) measurement system consists of I/O interface to input the ECG signals from two electrodes, FPGA (Field programmable gate arrays) module to process the signal conditioning, and real time module to control the system. The algorithms based on wavelet transform were developed to remove the noise of the ECG signals and to determine the QRS-waves. Triangular wave tests were conducted to determine the optimal factors of the wavelet filter by analyzing the SNRs (signal to noise ratios) and RMSEs (root mean square errors). The hybrid rule, soft method, and symlets of order 5 were selected as thresholding rule, thresholding method, and mother wavelet, respectively. The developed wavelet filter showed good performance to remove the noise of the triangular waves with 10.98 dB of SNR and 0.140 mV of RMSE. The ECG signals from a total of 6 subjects were measured at different measuring postures such as lying, sitting, and standing. The durations of QRS-waves, the amplitudes of R-waves, the intervals of RR-waves were analyzed by using the finite impulse response (FIR) filter and the developed wavelet filter. The wavelet filter showed good performance to determine the features of QRS-waves, but the FIR filter had some problems to detect the peaks of Q and S waves. The measuring postures affected accuracy and precision of the ECG signals. The noises of the ECG signals were increased due to the movement of the subject during measurement. The results showed that the wavelet filter was a useful tool to remove the noise of the ECG signals and to determine the features of the QRS-waves.

A Simple Multi-rate Parallel Interference Canceller for the IMT-2000 3GPP System (IMT-2000 3GPP 시스템을 위한 간단한 다중 전송률 병렬형 간섭제거기)

  • Kim, Jin-Kyeom;Oh, Seong-Keun;Sunwoo, Myung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • 제38권12호
    • /
    • pp.10-19
    • /
    • 2001
  • In this paper, we propose an effective but simple multi-rate parallel interference canceller(PIC) for the international mobile telecommunications-2000(IMT-2000) 3rd generation partnership project (3GPP) system. For effective multi-rate processing, we define the basic block as one symbol period of the dedicated physical control channel(DPCCH) having the lowest data rate and common to all users. Then, decision and interference cancellation are performed at every basic block. For an asynchronous channel, we propose an advance removal scheme that removes in advance multiple access interference(MAI) due to the next blockof other users with shorter delay. Introducing a pipeline structure at a sample base, we can implement efficiently the PIC using the advance removal scheme with a minimum hardware and no extra computations. Through computer simulations, we analyze the bit error rate(BER) performance of the proposed PIC with respect to signal-to-noise ratio(SNR) and the number of users.

  • PDF

Single Layer Array of Transmitting and Receiving Spiral Coils for Magnetostrictive Type Long-Range Ultrasonic Testing (자왜방식 원거리 초음파검사를 위한 단층 송수신 나선형 코일 배열)

  • Choi, Myoung Seon;Kim, Yoo Jin;Lee, Hyo Moon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • 제33권2호
    • /
    • pp.219-225
    • /
    • 2013
  • Separate and layered transmitting and receiving spiral coil arrays had been used for the optimized individual applications of magnetostrictive type long-range ultrasonic testing. In this study, it was demonstrated that when taking advantages of the spiral coils with the leg width reduced to be half of the previous one and of the empty spaces due to the decrease of leg width, the transmitting and receiving coil array can be arranged to form a single layer structure allowing more easy use and fabrication. Because of the number of turns of the receiving coils that is proportional to their leg width, the sensitivity of the single layer coil array was about half that of the corresponding double layer coil array while it allowed the receiving amplifier to get faster recovery from a saturation due to the main bang echo. It was also found that the two types of coil arrays have almost the same performances in the view points of signal-to-noise ratio and directivity control.

An Experimental Study of Comfortable Pitch and Loudness with Target Matching: Effects on Electroglottographic and Acoustic Measures

  • Choi, Seong Hee
    • Phonetics and Speech Sciences
    • /
    • 제4권4호
    • /
    • pp.139-146
    • /
    • 2012
  • This study was designed to examine comfort levels of pitch and loudness with target matching and their effects on electroglottographic (EGG) and acoustic measures. Twelve speakers, six males and six females, were instructed to produce /a/ sustained vowel for three seconds at a comfortable pitch and loudness level without any instruction and with a target matching procedure of either a certain f0 or SPL separately with visual and auditory feedback. The range of pitch for females and males were presented by progressing up and down randomly at intervals of 5Hz from 150 Hz to 310 Hz (total 33 frequency targets) and from 85 Hz to 190 Hz (total 22 frequency targets), respectively. The loudness levels were 65, 75, 85, 95 dB (total of four intensity targets) for both males and females. Subjective estimations of comfortable levels were obtained using a 10-point equal-appearing interval rating scale following each phonation. The results showed that males and females demonstrated similar trends in loudness levels with greatest comfort at 75 dB, whereas pitch comfort ratings showed a greater variability with females having a wider range with target matching. In the comfort levels of individuals, most male and female speakers rated higher comfort at soft, rather than loud phonations. On the other hand, most male speakers perceived highest comfort levels below the comfort pitch levels they phonated under natural conditions. Higher frequency ranges, however, were perceived to be more comfortable than those of natural condition in most female speakers, although the comfortable pitch levels in spontaneous phonations were within the comfort level ranges determined by targeted phonations. When comparing acoustic (%jitter, %shimmer, SNR) and EGG measures (CQ%) between spontaneous comfortable phonations and targeted phonations produced by the same subject at similar f0 and intensity, no significant differences were observed (p>0.05). Thus, target matching procedures may be considered a compatible and alternative method to reduce the variability of comfortable pitch and loudness levels by eliciting consistent comfortable phonations.

Optimum Missile Attitude to Minimize Radar Exposure at a High Altitude (고고도에서의 피탐성 최소화 유도탄 최적자세 연구)

  • Moon, Kyujin;Jeong, Ui-Taek;Kim, JeongHun;Ryoo, Chang-Kyung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • 제47권12호
    • /
    • pp.865-873
    • /
    • 2019
  • To improve the survivability of a missile, it needs to be lowered that the detection possibility by radars on the ground. The radar exposure of the target is given as a function of relative distance from the radar to the target and RCS (Radar Cross Section). The RCS of the missile is determined by the incidence angle of the target to electromagnetic radiation emitted from the radar. Under the assumption that the missile equips appropriate attitude control system, the attitude of the missile to minimize radar exposure at a high altitude is investigated in this paper. Two different types of performance cost are considered: the total sum of RCS and the total sum of SNR during the flight. Optimal solutions against multiple ground radars are found by using a SQP (Sequential Quadratic Programming)-based optimization technique.

Path Metric Comparison-based Adaptive QRD-M Algorithm for MUHO Systems (Path Metric 비교 기반 적응형 QRD-M MIMO 검출 기법)

  • Kim, Bong-Seok;Kim, Han-Nah;Choi, Kwon-Hue
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제33권6C호
    • /
    • pp.487-497
    • /
    • 2008
  • This paper proposes a new adaptive QRD-M algorithm for MIMO systems. The proposed scheme controls the number of survivor paths,0 based on the channel condition at each layer. The original QRD-M algorithm used fixed M at each layer and it needs large M to achieve near-MLD (maximum-likelihood detection) performance. However, using the large M increases the computation complexity. In this paper, we further effectively control M by employing the channel indicator which includes not only the channel gain, but also instantaneous noise information without necessity of SNR measurement. We found that the ratio of the minimum path metric to the second minimum is good reliability indicator for the channel condition. By adaptively changing M based on this ratio, the proposed scheme effectively achieves near MLD performance and computation complexity of the proposed scheme is significantly smaller than the conventional QRD-M algorithms.

On an Adaptation of Announcement Sound Level in White Noise Environment (백색소음 환경에서 음성안내레벨 적응에 관한 연구)

  • Yun, Jong-Jin;Bae, Myung-Jin
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • 제49권1호
    • /
    • pp.112-118
    • /
    • 2012
  • In daily life, there are many information broadcasting by using voice information systems. If surrounding noises are mixed with the information signals, the clarity of the signal become down graded too much to understand. Surrounding noises are not uniformed, but very irregular signals always changing. Therefore, it is very hard to control the output signals along with the irregular signals. This paper suggests a method to change the level of the voice information adapting to the surround noise in the white noise environment. The surround noise level is measured by subtracting the stored output voice signal from the voice signal degraded by the noise. The noise is used to estimation of SNR. And, the method to change the output level of voice signal adapting to the noise level. The suggested adaptive voice information system has the advantage to improve listeners' speech perception and to use amplifier's energy effectively.

Simple Precoding Scheme Considering Physical Layer Security in Multi-user MISO Interference Channel (다중 사용자 MISO 간섭 채널에서 물리 계층 보안을 고려한 간단한 프리코딩 기법)

  • Seo, Bangwon
    • The Journal of Korean Institute of Information Technology
    • /
    • 제17권10호
    • /
    • pp.49-55
    • /
    • 2019
  • In this paper, we propose a simple precoding vector design scheme for multi-user multiple-input single-output (MISO) interference channel when there are multiple eavesdroppers. We aim to obtain a mathematical closed-form solution of the secrecy rate optimization problem. For this goal, we design the precoding vector based on the signal-to-leakage plus noise ratio (SLNR). More specifically, the proposed precoding vector is designed to completely eliminate a wiretap channel capacity for refraining the eavesdroppers from detecting the transmitted information, and to maximize the transmitter-receiver link achievable rate. We performed simulation for the performance investigation. Simulation results show that the proposed scheme has better secrecy rate than the conventional scheme over all signal-to-noise ratio (SNR) range even though the special condition among the numbers of transmit antennas, transmitter-receiver links, and eavesdroppers is not satisfied.