• Title/Summary/Keyword: SN-38

Search Result 151, Processing Time 0.032 seconds

Effect of Annealing Temperature on the Electrical Performance of SiZnSnO Thin Film Transistors Fabricated by Radio Frequency Magnetron Sputtering

  • Kim, Byoungkeun;Lee, Sang Yeol
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.1
    • /
    • pp.55-57
    • /
    • 2017
  • Amorphous oxide thin film transistors (TFTs) were fabricated with 0.5 wt% silicon doped zinc tin oxide (a-0.5SZTO) thin film deposited by radio frequency (RF) magnetron sputtering. In order to investigate the effect of annealing treatment on the electrical properties of TFTs, a-0.5SZTO thin films were annealed at three different temperatures ($300^{\circ}C$, $500^{\circ}C$, and $700^{\circ}C$ for 2 hours in a air atmosphere. The structural and electrical properties of a-0.5SZTO TFTs were measured using X-ray diffraction and a semiconductor analyzer. As annealing temperature increased from $300^{\circ}C$ to $500^{\circ}C$, no peak was observed. This provided crystalline properties indicating that the amorphous phase was observed up to $500^{\circ}C$. The electrical properties of a-0.5SZTO TFTs, such as the field effect mobility (${\mu}_{FE}$) of $24.31cm^2/Vs$, on current ($I_{ON}$) of $2.38{\times}10^{-4}A$, and subthreshold swing (S.S) of 0.59 V/decade improved with the thermal annealing treatment. This improvement was mainly due to the increased carrier concentration and decreased structural defects by rearranged atoms. However, when a-0.5SZTO TFTs were annealed at $700^{\circ}C$, a crystalline peak was observed. As a result, electrical properties degraded. ${\mu}_{FE}$ was $0.06cm^2/Vs$, $I_{ON}$ was $5.27{\times}10^{-7}A$, and S.S was 2.09 V/decade. This degradation of electrical properties was mainly due to increased interfacial and bulk trap densities of forming grain boundaries caused by the annealing treatment.

Separation of Metals from Intergrated Circuit Chip Scrap by Mechanical Beneficiation (기계적 처리에 의한 반도체 IC칩 스크랩으로부터 유가금속의 분리에 관한 연구)

  • 이재천;이강인;이철경;양동효
    • Resources Recycling
    • /
    • v.3 no.1
    • /
    • pp.38-43
    • /
    • 1994
  • The separation of valuable metals from IC chip scrap generated by domestic electronic company was carried out using the mechanical beneficiation such as shredding, crushing, screening and magnetic separation. The distribution of metals in various sizes of crushed IC chip scrap was investigated and metals present in crushed products was separated with the magnetic separator. The particle size distribution of crushed IC chip scrap was 7.5% for +3mm, 17.0% for 3~1mm and 75.5% for -1mm. The weight loss of crushed IC chip scrap was 18% when roasted at $700^{\circ}C$. The content of metals was 96% for +3~1mm, 13% for 1~0.595mm, 3.7% for 0.95~0.5. Au of 99% was present in -1mm crushed IC chip scrap. Ni, Fe, Cu, Sn and Pb were separated from crushed IC chip scrap by the magnetic separator under 700 and 2, 500 Gauss.

  • PDF

Evaluation of Visual Performance for Implanted Aspheric Multifocal Intraocular Lens in the Cataract Patients (백내장 환자에서 비구면 다초점 인공수정체 삽입 후 시기능 평가)

  • Kim, Jae-Yoon;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.347-356
    • /
    • 2013
  • Purpose: To evaluate the visual acuity and visual performance after implantation of a aspheric multifocal (ReSTOR$^{(R)}$ SN6AD3) intraocular lens (IOL). Methods: Nineteen cataract patients (30 eyes) implanted with an aspheric multifocal IOL (ReSTOR$^{(R)}$ SN6AD3) either unilaterally or bilaterally were participated. Visual acuity (VA) and objective optical performance were evaluated at the time of preoperation, 1 week, 1 month, and 3 month after operation. At 3 month of post-operation, objective visual performance were measured and compared with the 38 eyes of 20 age-matched normal control. Distance VA was measured by using the ETDRS LCD chart and intermediate and near visual acuity were measured using Jaeger chart. Objective visual performance was assessed preoperatively and 1 week, 1 month and 3 month postoperatively using a double-pass system (Optical Quality Analysis System) with a 4-mm pupil diameter, the OSI (objective scatter index), MTF (modulation transfer function) cut off and strehl ratio. At 3 month of post-operation, visual acuity and visual performance compared with age matched normal control. Results: The uncorrected distance VA, OSI, MTF cut off and strehl ratio were significantly improved (p<0.05) until 1 month postoperatively. Visual performance of MTF cut off and strehl ratio after 3 month of operation were significantly improved compared to the normal control (p=0.063, p=0.103 respectively), however, OSI was higher than normal control. Patients implanted with aspheric multifocal IOL were satisfied with distance and near VA however, were unsatisfied with intermediate VA and reported glare and halos. Conclusions: The visual performance reaches to a stable condition in 1 month of implantation of aspheric multifocal IOL and improved to the level of age-mated normal patients. Also patients were satisfied with their quality of vision, however, intermediate VA, glare and halos were reported as complications.

A source and phase identification study of the 10 December 2002 Cheolwon, Korea, earthquake of ML 3.6 (2002년 12월 10일 규모 3.6 철원지진의 진원요소 및 파상분석)

  • 김우한;박종찬;함인경;김성균;박창업
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.5
    • /
    • pp.19-24
    • /
    • 2003
  • We analysed seismic phases recorded by the 10 December 2002 Cheolwon, Korea, earthquake of $M_{L}$ 3.6 and obtained source parameters such as hypocenter, origin time, earthquake magnitude. Velocity and acceleration records used in this study are from the KMA and KIGAM seismic networks. Due to the location of the epicenter in the north of the DMZ(Demilitarized Zone), direct Pg phases were recorded only at five stations in the area south of DMZ. Identification of refracted Pn phase as the first arrival is difficult in most stations. Therefore, the hypocenter determined by existing routine methods could be affected by a large error. In order to avoid the possibility of the problem, we employed a method of seismic phase analysis developed by Kim et al.. The direct, refracted, and reflected P and S phases were successfully identified using the method together with the travel time curve data. In order to improve the accuracy in determination of the hypocenter and origin time, we included PmP and SmS phases in the analysis in addition to the phases such as Pg, Pn, Sg and Sn. The epicenter, depth, and origin time of the Cheolwon earthquake determined based on data of 11 stations within 200km from the epicenter are $38.81^{\circ}$N, $127.22^{\circ}$E, 12.0km, and 7:42:51.4(local time), respectively. The average value of the local magnitude based on the Richter's definition from all the stations is 3.6 in $M_{L}$. This magnitude is smaller by 0.2 and 0.5 compared with magnitudes determined by KMA and KIGAM, respectively.

Heavy Metal Contents of Canned Seafoods Packed in Oil (수산물 기름 담금 통조림 식품의 중금속 함량)

  • Heu, Min-Soo;Kim, Jin-Soo
    • Applied Biological Chemistry
    • /
    • v.47 no.3
    • /
    • pp.307-314
    • /
    • 2004
  • Specification and heavy metal contents of canned seafoods packed in oil were investigated. 30 species of canned tuna were classified by 4 groups as follow; group (sample codes, 1-10) composed of tuna and oil only, group (11-18) composed of tuna, vegetable and oil, group (19-27) composed of tuna, sauce and oil, and group (28-30) composed of tuna, vegetable, sauce and oil. Commercial canned shellfish packed in oil were mainly produced from sea mussel (sample codes, 31 and 32) and oyster (33-35). Can bodies of canned tuna were made by tin-plate, and used c-enamel or aluminium-paste as coating materials. In pH values of canned tuna, sample codes 1-10 (pH 5.55-5.69) and 19-27 (pH 5.17-5.85) were higher than sample codes 11-18 (pH 4.95-5.43) and 28-30 (pH 5.20-5.38). There was no difference in salinity (1.3-1.9%) and vacuum degree (15-18 mmHg) among canned samples. Heavy metal contents of canned seafoods ranged from 1.04-9.03 ppm for Sn, and 0.17-0.68 ppm for Pb. Those values are below the permitted range (less than 150 ppm for Sn and 2 ppm for Pb).

The 4:1(50-Ω:12.5-Ω) microstrip-slot line impedance transformer using a dielectric resonator (유전체 공진기를 이용한 4:1(50-Ω:12.5-Ω) 마이크로스트립-슬롯 선로 임피던스 변환기)

  • Park, Ung-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.11
    • /
    • pp.1484-1491
    • /
    • 2020
  • Since the slot line transmits electric and magnetic signals through the slot, the size of the slot greatly affects the signal power loss. In order to have low loss, the slot line is mainly used at a high frequency of above 3GHz on a substrate having a high dielectric constant(er). This paper proposes the 4:1 impedance transformer using a slot line on TLC-30 laminate (h=20mil, er=3.0; Taconic) being a relatively low dielectric constant at a frequency of 1.85GHz. In the proposed impedance transformer, the dielectric resonator is arranged on the slot line to reduce signal loss occurring at the slot line. The proposed 4:1 microstrip-slot line impedance transformer fabricated using a (Zr,Sn)TiO4 dielectric resonator(er=38) has the transmission loss(S21) of -0.375dB and the reflection value(S11) of -27.6dB at 1.855GHz. This confirms that the slot line can be stably used even in a low dielectric constant substrate and a low frequency region by using a dielectric resonator.

Ferroelectric Properties of Pb[(Zr,Sn)Ti]N$bO_3$ Thin Films by Annealing (열처리에 따른 Pb[(Zr,Sn)Ti]N$bO_3$ 박막의 강유전 특성)

  • Choe, U-Chang;Choe, Hyeok-Hwan;Lee, Myeong-Gyo;Gwon, Tae-Ha
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.7
    • /
    • pp.473-478
    • /
    • 2001
  • Ferroelectric P $b_{0.99}$[(Z $r_{0}$ 6S $n_{0.4}$)/0.9/ $Ti_{0.1}$]0.98/N $b_{0.02}$ $O_3$(PNZST) thin films were deposited by a RF magnetron sputtering on L $a_{0.5}$S $r_{0.5}$Co $O_3$(LSCO)/Pt/Ti/ $SiO_2$/Si substrate using a PNZST target with excess PbO of 10 mole%. The crystallinity and electrical properties of the thin films annealed at various temperature and time were investigated. The thin films deposited at the substrate temperature of 500 $^{\circ}C$ and the power of 80 W were crystallized to a perovskite phase after rapid thermal annealing(RTA). The thin films annealed at 650 $^{\circ}C$ for 10 seconds in air exhibited the good crystal structures. The remanent polarization and coercive field of the PNZST capacitor were about 20 $\mu$C/$\textrm{cm}^2$ and 50 kV/cm, respectively. The reduction of the polarization after 2.2$\times$10$^{9}$ switching cycles was less than 10 %..10 %......

  • PDF

Analysis and Enzymatic Production of Structured Lipids Containing DHA Using a Stirred-Batch Type Reactor (회분식 반응기를 이용한 DHA 함유 재구성지질의 효소적 합성 및 이화학적 특성 분석)

  • Kim, Nam-Sook;Lee, Ki-Teak
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.7
    • /
    • pp.1052-1058
    • /
    • 2005
  • Structured lipid (SL) was synthesized by enzymatic interesterification with algae oil containing docosahexaenoic acid (DHA) and soybean oil in the stirred-batch type reactor. The reaction was performed for 15hr at $65^{\circ}C$ with 300 rpm catalyzed by sn-1,3 specific Lipozyme RM 1M lipase from Rhizomucor miehei ($11\%$ by weight of total substrates) in the absent organic solvent. SL contained $87.1\;area\%$ triacylglycerol (TAG), $12.1\;area\%$ diacylglycerol (DAG), $0.6\;area\%$ monoacylglycerol (MAG), and $0.2\;area\%$ free fatty acid (FFA). Major fatty acid profiles of SL were DHA $(15.7\;mol\%)$, linoleic $(31.1\;mol\%)$, palmitic $(20.2\;mol\%)$, oleic $(13.5\;mol\%)$ and eicosapentaenoic acid $(EPA,\;6.6 mol\%)$. SL contained the newly synthesized several peaks. Iodine and saponification of SL were 206.7 and 183.8. SL color showed darker and redder than soybean oil, and appeared the most yellowish color among SL, soybean, and algae oil.

MID-FACIAL SOFT TISSUE CHANGES FOLLOWING ORTHOGNATHIC SURGERY OF THE MAXILLA IN KOREANS (한국인에서의 상악골 교정수술후 안면중부 연조직 변화에 관한 연구)

  • Park, Hyung-Sik;Choi, Jin-Ho;Kim, Young-Soo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.3
    • /
    • pp.278-290
    • /
    • 1991
  • Prediction of the sop tissue changes following hard tissue movements is very important in the preoperative analysis of surgical changes of the patient who have orthognathic surgery. This study examined post operative changes of the mid-facial sop tissues in Koreans depending upon two major positional changes of the maxilla following Le Fort - I type osteotomy for orthognathic purposes. Sixty patients(41 males and 19 females) of Koreans were selected and divided into two groups according to directional change of movement of anterior bony structures of the Maxilla as follows : Group I (44 patients) was mooed anteriorly and/or inferiorly, and Group II (16 patients) was mooed posteriorly and/or superioly. Postoperative changes of the sop tissue measurements following hard tissue changes were examined on pre - and post - operative cephalometrics by means of computerized digitation methods and the ratios of changes were analysed. The results were obtained as follows : 1. In Group I, all of the sop tissue measures except the Pn was closely followed by the changes of the hard tissue measures in the horizontal plane, but the Sn and the Cm were only correlated to the vertical changes(p<0.001). In group II, all of the sop tissue measures excluding of the N' and the Pn were significantly correlated to the hard tissue measures in horizontal plane(p<0.001), but the Ls and Stm were only correlated relatively to the vertical changes of the ANS(p<0.01). 2. Predictable ratio of the Sn was 66% of the ANS or 56% of the A in the horizontal plane and 89% of the A in the vertical plane in Group I. In Group II, the Sn was predictable as 85% of the ANS or 70% of the A in the horizontal plane but was not predictable in vertical plane. 3. Predictable ratio of the Cm was 28% of the ANS or 50% of the A in the horizontal plane and 56% of the ANS or 36% of the A in the vertical plane in Group I. In Group II, the Cm was predictable horizontally as 74% of the A. Predictable ratio of the Pn was 30% of the ANS or 38% of the A in horizontal plane in Group I, but it was not predictable both horizontally and vertically in Group II. 4. Predictable ratio of the Ls was 52% of the Pr in Group I and 77% in Group II in the horizontal plane. The Stm was predictable as 34% of the pr or 22% of the I in the horizontal plane in Group I, and was also predictable as 55% of the pr or 68% of the I horizontally and 21% of the pr or 65% of the I vertically in Group II. 5. All ratios of change in the thickness. length and area of the upper lip following maxillary movement were statiscally correlated, however, mangitudes of them were meaningful clinically.

  • PDF

EFFICACY OF ENaP(ESTHETIC NaP)-LINE FOR ORTHOGNATHIC SURGERY OF KOREAN MANDIBULAR PROGNATHISM (한국인 하악골 전돌증 환자의 악교정수술을 위한 ENaP(Esthetic NaP)선의 유효성에 관한 연구)

  • Kim, Jong-Kook;Park, Hyung-Sik
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.5
    • /
    • pp.372-382
    • /
    • 2002
  • As the most of dentofacial deformity patients indicated to orthognathic surgery have strong desire for esthetic improvement as well as functional improvement, ideal esthetic evaluation should be made at surgical prediction. Lateral cephalographs has been commonly used for surgical prediction, however, remarkable discrepancy between esthetic viewpoint by simple looking and analysis on lateral cephalographs often found on evaluation of sagittal position of the upper and lower jaws especially in cases of mandibular prognathism of Koreans. In these cases, we have been employed Esthetic NaP(ENaP)-line for corrective evaluation and ideal surgical prediction on lateral cephalographs, but the efficacy of ENaP-line has not been evaluated. This is a study on efficacy of ENaP-line for orthognathic surgery of Korean mandibular prognathism. 170 Korean patients who had been diagnosed as mandibular prognathism and planned for orthognathic surgery at Department of Oral and Maxillofacial Surgery, College of Dentistry, Yonsei University during last 10 years are studied. The obtained results are as followings; among 170 patients of mandibular prognathism, 132 patients(77.6%) had not discrepancy in evaluation of sagittal position of the maxilla between cephalometric and esthetic evaluation(they are classified as Group I), however, 38 patients(22.4%) had definite discrepancy(they are classified as Group II). ENaP-line was employed in all cephalometric analysis of Group II. The proportions of male and female were similar in both Groups. Sixteen vertical reference lines perpendicular to 16 horizontal reference lines were obtained as followings; Each of the representative degree of ${\angle}SN/AFH$, ${\angle}SN/CFH$ and ${\angle}AFH/CFH$ obtained at Group I was applied to SN plane, AFH plane and CFH plane of Group II each other, and so 16 horizontal reference lines could be obtained individually according to each of the applied degree to each plane. And then their reliability to coincide with ENaP-line of Group II was evaluated. A vertical reference line perpendicular to a horizontal line made by application of the representative degree of ${\angle}$AFH/CFH in Group I to AFH line in Group II had the most highest coincidence with ENaP-line of Group II, however, its agreement was 42% in male and 47% in female. From this results, the rest of them should be determined their corrective jaw position definitely depend on