• Title/Summary/Keyword: SLAB

Search Result 2,939, Processing Time 0.03 seconds

A Behavior Analysis of HSR concrete slab track under Variety of Rail pad stiffness on fatigue effect (피로효과를 고려한 레일패드 스프링계수 변화에 따른 콘크리트 슬래브 궤도의 거동분석)

  • Eom, Mac;Choi, Jung-Youl;Chun, Dae-Sung;Park, Yong-Gul
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.340-350
    • /
    • 2007
  • The major objective of this study is to investigate the fatigue effects of rail pad on High Speed Railway with concrete slab track system. It analyzed the mechanical behaviors of HSR concrete slab track with applying rail pad stiffness based on fatigue effect(hardening and increasing stiffness) on the 3-dimensional FE analysis and laboratory test for static & dynamic characteristics. As a result, the hardening of rail pad due to fatigue loading condition are negative effect for the static & dynamic response of concrete slab track which is before act on fatigue effect. The analytical and experimental study are carried out to investigate rail pad on fatigue effected increase vertical acceleration and stress and decrease suitable deflection on slab track. And rail pad based on fatigue effect induced dynamic maximum stresses, the increase of damage of slab track is predicted by adopting fatigue effected rail pad. after due consideration The servicing HSR concrete slab track with resilient track system has need of the reasonable determination after due consideration fatigue effect of rail pad stiffness which could be reducing the effect of static and dynamic behavior that degradation phenomenon of structure by an unusual response characteristic and a drop durability.

  • PDF

The Allowable Displacement Limit on the Approach Slab for a Railway Bridge with Ballastless Track (콘크리트궤도부설 교량의 접속슬래브 허용변위한도에 관한 연구)

  • Choi, Jin-Yu;Yang, Shin-Chu;Yoo, Jin-Young;Cho, Hyun-Cheol
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1149-1155
    • /
    • 2007
  • The transition area between a bridge and an earthwork is one of the weakest area of track because of the track geometry deterioration caused unequal settlement of backfill of abutment. In case of a ballastless track, the approach slab is installed to prevent the phenomenon. But, if there is occurred the inclined displacement on the approach slab by a settlement of the foundation or formation, the track is also under the inclined displacement. And this defect causes reducing the running stability of a vehicle, the riding comfort of passengers, and the deteriorations of track by excessive impact subjected to the track. In this study, parametric studies were performed to know what is the allowable displacement limit on the approach slab to avoid such a bad effect. The length and amount of unequal settlement of the approach slab was adopted as parameter for numerical analysis. And car body accelerations, variations of wheel force and rail stress and uplift force induced on a fastener clip are investigated. From the result, resonable settlement limits of an approach slab according to slab length was suggested.

  • PDF

Shear Strength of One-way Hollow Slab According to Effective Cross Section and Reinforcement Ratio (유효단면 및 철근비에 따른 일방향 중공슬래브 전단강도)

  • Seok, Keun-Young;Ye, Sang-Min;Kang, Joo-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.2
    • /
    • pp.90-98
    • /
    • 2014
  • The shear behavior of reinforced concrete structure is one of difficult problems that are not clearly identified theoretically despite the efforts of researchers for several years. Since bending and shear strength of hollow slab may decrease due to hollow part inside slab, prediction of such structure performance is very important. Presently the formulas of shear designing standard expressions of each country are formulas by experiment for hollow slab. In this study, the shear behavior of one-way hollow slab by reinforcement ratio were analyzed through experiment to conduct studying on estimation of shear strength, and then shear strength formulas of hollow slab were compared and analyzed.

Performance Analysis of Energy-Slab Ground-Coupled Heat Exchanger (에너지슬래브 지중열교환기의 성능 분석)

  • Choi, Jong-Min;Sohn, Byong-Hu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.6
    • /
    • pp.487-496
    • /
    • 2012
  • Recently, utilization of building foundations as ground-coupled heat exchangers has attracted much attention because they reduce the cost and enhance the heat transfer. The objective of this study is to evaluate the performance of energy-slab ground-coupled heat exchanger installed in a commercial building. In order to demonstrate the energy transfer characteristics of the energy-slab, experiments were conducted from October 2010 to September 2011. The 1-year measurement results showed that the mean EWTs of brine returning from the energy-slab were $9.6^{\circ}C$ in heating season and $24.9^{\circ}C$ in cooling season, which were in a range of design target temperatures. In addition, the geothermal heat pump system with the energy-slab showed on-off operation according to the setting temperatures of secondary fluid in water storage tank. The results also showed that the energy-slab extracted heat of 198.6 kW from the ground and injected heat of 318.9 kW to the ground, respectively.

An Experimental Study on Bending Performance of Half Precast Concrete Slab with Truss-Reinforcement (트러스 철근을 갖는 하프 프리캐스트 슬래브의 휨 내력에 관한 실험적 연구)

  • Seo, Tae-Seok;Choi, Chang-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.6
    • /
    • pp.71-80
    • /
    • 2008
  • A slab examined by this study is the half precast concrete(PC) slab with the truss-reinforcement. There are many studies on the composite slab, but the study on the half precast concrete(PC) slab is little. Especially, the study on a structural performance of the half PC slab according to the height of the truss-reinforcement is extremely little. Therefore, in this research, three kinds of slabs with different height of the truss-reinforcement were made, and the bending test was conducted to research a structural performance.

Performance Evaluation of Floor Vibration of Biaxial Hollow Slab Subjected to Walking Load (보행하중에 대한 2방향 중공슬래브의 진동성능 평가)

  • Kim, Min-Gyun;Park, Hyun-Jae;Lee, Dong-Guen;Hwang, Hyun-Sik;Kim, Hyun-Su
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.5
    • /
    • pp.11-21
    • /
    • 2009
  • Considering that the weight of a biaxial hollow slab system is not increased with an incremental increase in its thickness, and that the flexural stiffness of a biaxial hollow slab is not significantly lower than that of a general solid slab, there has been a growing need for biaxial hollow slab systems, because long span structures are in great demand. In a long span structure, the problem of vibration of floor slabs frequently occurs, and the dynamic characteristics of a biaxial hollow slab system are quite different from the conventional floor systems. Therefore, in this study, the floor vibration of a biaxial hollow slab system subjected to walking load is investigated in comparison with a conventional floor slab system. For the efficiency of time history analysis, an equivalent plate slab model that can precisely represent the dynamic behavior of a biaxial hollow slab system is used. From the analytical results, it was determined that vibration of a biaxial hollow slab system subjected to walking load is evaluated as "office-level vibration," according to the classifications of the architectural institute of Japan and ANSI.

Effects of Stiffness of Face Supporting Zone on Face Slab Behaviors of CFRD (CFRD 차수벽지지죤 강성이 콘크리트차수벽 거동에 미치는 영향)

  • Ha, Ik Soo;Seo, Min Woo;Kim, Hyoung Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5C
    • /
    • pp.351-358
    • /
    • 2006
  • The purpose of this study is to recommend the simulation method and procedure of behaviors of CFRD(Concrete Faced Rockfill Dam) concrete face slab with impoundment by centrifuge tests, to examine the effects of the flexural rigidity of the concrete face slab on the face slab deformation from the centrifuge tests, and to evaluate the effects of the stiffness of face supporting zone on the displacement and moment of face slab by numerical analysis which is verified by the centrifuge tests. In this study, the centrifuge tests on the two model dams with the concrete face slab of different flexural rigidity were carried out. Also, the centrifuge tests were simulated by numerical analysis of which input material properties were obtained by the triaxial tests on the model materials. The validity of numerical analysis was evaluated by comparison between the results of centrifuge tests and numerical simulation. The deformation pattern of the concrete face slab was examined with the various stiffness of the face supporting zone by numerical analysis. From the results of centrifuge tests, the effects of face slab thickness on the deformation of face slab were negligible. From the results of centrifuge tests and numerical analysis, it was found that the amplitude of the maximum displacement of face slab and the position where the maximum displacement was mobilized with impoundment were affected by the stiffness of face supporting zone rather than the flexural rigidity of concrete face slab.

Concrete Slab with Partial Supports due to its Deformation (자체변형에 의한 부분지지조건을 갖는 콘크리트 슬래브)

  • 한승환;유태석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.429-432
    • /
    • 1999
  • The concrete slab on the foundation may have curling and warping deformations due to moisture and temperature gradient of its section. These deformations may change the support conditions of concrete slabs, and cause higher level of stresses than expected. This study was performed to verify the effect of partial support condition of concrete slab on the foundation due to its deformations and to develop the useful analytic method for describing these phenomenons. The partial support condition verified by FWD test results, and it was concluded that the gap model could be useful in analysing the concrete slab with partial support conditions.

  • PDF

Transmissibility of High-Strength Concrete Column Loads through Normal-Strength Concrete Slabs (일반 강도 콘크리트 슬래브를 통한 고강도 콘크리트 기둥의 축력 전달)

  • 윤영수;데니스미첼
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.521-524
    • /
    • 1999
  • Twelve column specimens were tested in compression, six were slab-column specimens and six were isolated column specimens. The slab column specimens were first tested to punching shear failure before the columns of the specimens were loaded axially. The effects of confinement from the surrounding slab on the axial capacity of the columns was investigated. Other parameters investigated were the placement of fiber-reinforced concrete in the slab and the concentration of flexural reinforcement in the column vicinity.

  • PDF

Minimum Thickness of RC Bridge Slab Considering Fatigue and Serviceability (피로강도와 사용성을 고려한 RC 바닥판의 최소두께)

  • Hwang Hoon Hee;Joh Changbin;Kim Byung Suk;Jung Chul Hun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.248-251
    • /
    • 2004
  • This study was performed to propose the minimum thickness of RC slab that satisfies constructibility, fatigue safety, and serviceability requirements such as deflection control. Three different minimum thicknesses are calculated using concrete shear and rebar fatigue formulas, and deflection control, respectively, and checked by constructiblity. The maximum of these three minimum thicknesses is proposed as the minimum thickness of RC slab, which shows that the minimum thickness requirement of RC slab from Korean Bridge Design Code can be thinner than now.

  • PDF