• 제목/요약/키워드: SIMPLER 방법

Search Result 250, Processing Time 0.029 seconds

Development of AHP-MAUT Hybrid Model to Enhance Effectiveness of Decision Support System (의사결정지원시스템 AHP의 편의성 개선을 위한 하이브리드 모형의 개발)

  • Bae Deuk Jong
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.421-426
    • /
    • 2024
  • The Analytic Hierarchy Process (AHP) converts people's judgment criteria into objective numerical values using pairwise comparisons. However, the need for an excessive number of pairwise comparisons poses a problem. To mitigate this issue, most existing studies have utilized the process separation approach. The method of process separation devised in this study is a "separation and integration approach," where 1) the standard AHP process is used for evaluating judgment criteria, and 2) the Multi-Attributive Utility Technique (MAUT) is applied for comparing alternatives. This AHP-MAUT Hybrid model was applied to a real analysis case, specifically analyzing the transportation choices of commuters between Bundang and Gangnam Station in Gyeonggi Province. The results showed that the computational process was reduced by 42.03% when applying the Hybrid model compared to using the AHP model alone. Furthermore, the choice results of residents using the Hybrid model were compared with those using the standard AHP. The consistency between the two models' choices was 82.1%, indicating a significant level of consistency. In conclusion, this study contributes by presenting a simpler, more convenient, yet equally effective Hybrid model as a new decision-support system alternative to AHP.

Comparison of Tyurin Method and Dry Combustion Method for Carbon Analysis in Soils of Low Iorganic Carbon content (무기탄소 함량이 낮은 토양의 탄소함량 분석을 위한 Tyurin법과 건식연소법의 비교)

  • Seo, Myung-Chul;So, Kyu-Ho;Ko, Byong-Gu;Son, Yeon-Kyu
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.37 no.5
    • /
    • pp.315-321
    • /
    • 2004
  • To compare soil carbon contents by Tyurin method and dry combustion method, we carried out analysis for 212 samples of agricultural land in Korea. The average values of soil carbon contents analyzed by Tyurin method and dry combustion method were $17.47{\pm}10.80$ and $19.91{\pm}10.63g\;kg^{-1}$, respectively. Both methods were evaluated as acceptable methods for soil carbon contents as the results showed. The results showed that soil texture had little effect on analysis method of carbon contents. Highly significant linear regression equation, Y = 0.846X ($R^2=0.991$), was obtained between carbon contents analyzed by Tyurin method (Y) and dry combustion method (X). As a result of comparison with data of carbon contents of the two methods, about 69% of results at dry combustion method have exceeded to results at Tyurin method. Especially, differences between results at two methods became higher as carbon contents were increasing. Tyurin method has been advantages such as shorter analysis time for one sample, more recognition for carbon analysis, and no need for expensive analyzer, while dry combustion method has simpler procedure, no heavy metal wastes, and more samples for analysis at one time.

A Study on the Changes in Ventilator Care Rate and Outcome of Very Low Birth Weight Infants During Last Four Years (최근 4년간 극소 저출생 체중아의 인공 호흡기 치료율과 경과 변화에 관한 연구)

  • Jung, Byun Kyung;Kim, Yeoung Ju;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.11
    • /
    • pp.1073-1079
    • /
    • 2003
  • Purpose : Recently there has been a decrease in ventilator care rate and duration of very low birth weight infants(VLBWI) in Fatima Hospital. The aims of this study were to survey the frequency and duration of ventilation in VLBWI and to develop a non-invasive neonatal intensive care unit (NICU) policy. Methods : We performed a retrospective study of 284 newborn of infants less than 1,500 gm admitted to NICU and discharged from January 1998 to December 2001. Patients were intubated or applied continuous positive airway pressure(CPAP) via nasal prong immediately after presenting signs of respiratory distress. We analyzed epidemiologic data to study the changes in ventilator care rate, duration and outcome of ventilator care groups. Results : Of 284 newborn infants, 146 required invasive management, such as endotracheal intubation and assisted ventilation. The characteristics, the severity of clinical symptoms and laboratory findings in ventilator care groups at birth showed no significant differences. The annual proportion of infants requiring assisted ventilation decreased according to increasing gestational age. The median duration of ventilation decreased markedly from 6.0 days in 1998 to 2.7 days in 2001. Final complications and outcomes in ventilator care groups showed no significant differences. Conclusion : Our study shows a significant reduction in the invasiveness of the treatment of VLBW infants, which was not associated with an increased mortality or morbidity. A non-invasive strategy for the VLBW infant with minimal to moderate respiratory distress after birth in NICU is better than immediate invasive management. Non-invasive nasal CPAP is a simpler and safer method than invasive assisted ventilation.

Electrochemical Treatment of Dye Wastewater Using Fe, RuO2/Ti, PtO2/Ti, IrO2/Ti and Graphite Electrodes (RuO2/Ti, PtO2/Ti, IrO2/Ti 및 흑연전극을 이용한 염료폐수의 전기화학적 처리)

  • Kim, A Ram;Park, Hyun Jung;Won, Yong Sun;Lee, Tae Yoon;Lee, Jae Keun;Lim, Jun Heok
    • Clean Technology
    • /
    • v.22 no.1
    • /
    • pp.16-28
    • /
    • 2016
  • Textile industry is considered as one of the most polluting sectors in terms of effluent composition and volume of discharge. It is well known that the effluents from textile dying industry contain not only chromatic substances but also large amounts of organic compounds and insolubles. The azo dyes generate huge amount of pollutions among many types of pigments. In general, the electrochemical treatments, separating colors and organic materials by oxidation and reduction on electrode surfaces, are regarded as simpler and faster processes for removal of pollutants compared to other wastewater treatments. In this paper the electrochemical degradation characteristics of dye wastewater containing CI Direct Blue 15 were analyzed. The experiments were performed with various anode materials, such as RuO2/Ti, PtO2/Ti, IrO2/Ti and graphite, with stainless steel for cathode. The optimal anode material was located by changing operating conditions like electrolyte concentration, current density, reaction temperature and initial pH. The degradation efficiency of dye wastewater increased in proportion to the electrolyte concentration and the current density for all anode materials, while the temperature effect was dependent on the kind. The performance orders of anode materials were RuO2/Ti > PtO2/Ti > IrO2/Ti > graphite in acid condition and RuO2/Ti > IrO2/Ti > PtO2/Ti > graphite in neutral and basic conditions. As a result, RuO2/Ti demonstrated the best performance as an anode material for the electrochemical treatment of dye wastewater.

Effect of Antibody Immobilization Method to Magnetic Micro Beads on its Immunobinding Characteristics (자성 미세입자에의 항체 고정화 방법이 면역결합반응에 미치는 영향)

  • Choi, Hyo Jin;Hwang, Sang Youn;Jang, Dae Ho;Cho, Hyung Min;Kang, Jung Hye;Seong, Gi Hun;Choo, Jae Bum;Lee, Eun Kyu
    • Korean Chemical Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.65-72
    • /
    • 2006
  • Recent technical advances in the biorecognition engineering and the microparticle fabrication may enable us to develop the single step purification using magnetic particle, because of its simplicity, efficacy, ease of automation, and process economics. In this study, we used commercial magnetic particles from Seradyn, Inc. (Indianapolis, USA). It was ca. 2.8 micron in diameter, consisted of polystyrene core and magnetite coating, and its surface had carboxyl groups. The model, capture protein was IgG and anti-IgG was used as the ligand molecule. We studied the different surfaces ('nude', ester-activated, and anti-IgG coated) for their biorecognition of IgG. At a high pH condition, we could reduce non-specific binding. Also anti-IgG immobilized magnetic particle could capture IgG more selectively. We attempted 'oriented immobilization' of anti-IgG, in which the polysaccharides moiety near the C-terminus was selectively oxidized and linked to the hydrazine-coated MP, to improve the efficacy of biorecognitive binding. Using this method, the IgG capturing ability was improved by ca. 2 fold. From the binary mixture of the IgG-insulin, IgG could be more selectively captured. In summary, the oriented immobilization of oxidized anti-IgG proved to be as effective as the streptavidin-biotin system and yet simpler and cost-effective. This immobilization method can find its applications in protein biochips and biotargeting.

Use of Intermittent Antegrade Warm Blood Cardioplegia in CABG (관상동맥 우회로조성술에서 간헐적 전방 온혈 심정지액의 이용)

  • 김정택;백완기;김영삼;윤용한;김혜숙;이춘수;임현경;김현태;김광호
    • Journal of Chest Surgery
    • /
    • v.36 no.11
    • /
    • pp.828-833
    • /
    • 2003
  • Background: It has been reported that the recently developed intermittent antegrade warm blood cardioplegia (IAWBC) has better myocardial protective effects during coronary artery bypass surgery than cold blood cardioplegia or continuos retrograde cold blood cardioplegia. The aim of this study is to evaluate the safety and usefulness of IAWBC by comparing it retrospectively with intermittent retrograde cold blood cardioplegia (lRCBC). Material and Method: From April 2001 to Feb. 2003, fifty seven patients who underwent isolated coronary surgery were divided into two groups (IAWBC vs. IRCBC). The two group had similar demographic and angiographic characteristics. There were no statistical differences in age, sex, Canadian Cardiovascular Society Functional Classification for angina, ejection fraction, and number of grafts. Result: Aortic cross clamping time and total pump time in IAWBC (99$\pm$23 and vs. 126$\pm$32 min) were shorter than those of IRCBC (118$\pm$32 min. and 185$\pm$48 min.)(p<0.05). The reperfusion time (13$\pm$7 min) in IAWBC was shorter than that of IRCBC (62$\pm$109 min.)(p<0.05). CKMB at 12 hours and 24 hours (16$\pm$15 and 9$\pm$13) in IAWBC was lower than that of IRCBC (33$\pm$47 and 17$\pm$26)(p<0.05). The awakening time in IAWBC (2$\pm$1 hour) was shorter than that of IRCBC (4$\pm$3)(p<0.05). The number of spontaneous heart beat recovery in IAWBC (85%) was more than that of IRCBC (35%)(p<0.05). The cardiac index after discontinuing cardio-pulmonary bypass was significantly elevated in the IAWBC group. The prevalence of perioperative myocardial infarction in IAWBC (4%) was lower than that of IRCBC group (20%)(p<0.05). Conclusion: Intermittent antegrade warm blood cardioplegia is a safe, reliable, and effective technique for myocardial protection. It can also provide simpler and economic way than the retrograde cold cardioplegia by shortening of cardiopulmonary bypass time and avoiding retrograde cannulation for coronary sinus.

The Significance of Sentinel Node Biopsy in Malignant Melanoma and Squamous Cell Carcinoma of Lower Extremities (하지에 발생한 악성흑색종 및 편평상피세포암에서 소속 림프절 생검의 의미)

  • Kim, Jae-Do;Lee, Gun-Woo;Kwon, Young-Ho;Chung, So-Hak
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.16 no.2
    • /
    • pp.69-73
    • /
    • 2010
  • Purpose: Sentinel lymph node (SLNB) is the first confronted lymph node from primary lesion of tumor through lymphatic drainage, which is important for determining early metastasis and setting guidelines for treatment. We reported significant of sentinel lymph node biopsy in malignant melanoma (MM) and squamous cell carcinoma (SCC) of lower extremities. Materials and Methods: Twenty-five cases of surgically treatment and being possible for follow up more than 1 year among the patients who were diagnosed as MM and SCC in this institution from Sep. 2005 to Jan. 2009, and 10 cases of them were performed SLNB. Average age was 64 years old, and 15 cases of male and 10 cases of female were in this group. Results: 3 years overall survival rate was 100% and 3 years disease-free survival rate was 76%. Metastasis occurred in total 6 patients, 4 cases of inguinal lymph nodes, 1 case of soft tissue around knee, 1 case of left achilles tendon. In 15 cases of not performing SLNB, overall survival rate was 93.3% and disease-free survival rate was 73.3%. In 10 cases of performing SLNB, overall survival rate was 100% and disease-free survival rate was 90%. And only 1 case showed positive finding in the biopsy, and none of the 10 cases showed metastasis in follow-up. Conclusion: SLNB leads simpler and less complications compared to prior elective lymph node dissection, and shows high degree of accuracy. Throughout the SLNB, setting guidelines for treatment by accurate staging is thought to be helpful for increasing the survival rate in the patient with MM and SCC.

Usability assessment of thermoplastic Bolus for skin VMAT radiotherapy (피부 병변에 대한 VMAT 치료 시 열가소성 bolus의 유용성 평가: case review)

  • Kim, Min Soo;Kim, Joo Ho;Shin, Hyun Kyung;Cho, Min Seok;Park, Ga Yeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.85-92
    • /
    • 2020
  • Purpose: To find out the advantages of thermoplastic bolus compared to conventional bolus, which is mainly used in clinical practice, We evaluated Two cases in terms of dose and location reproducibility to assess Usability of thermoplastic Bolus for skin VMAT radiotherapy. Materials and Methods: Two patient's treated with left breast skin lesion were simulated using thermoplastic Bolus and planned with 2arc VMAT. the prescription dose was irradiated to 95% or more of the target volume. We evaluated The reproducibility of the bolus position by measuring the length of the air gap in the CBCT (Cone Beam CT) image. to evaluate dose reproducibility, we compared The dose distribution in the plan and CBCT and measured in vivo for patient 2. Results: The difference between the air gap in patient 1's simulation CT and the mean air gap (M1) during 10 treatments in the CBCT image was -0.42±1.24mm. In patient 2, the difference between the average air gap between the skin and the bolus (M2) during 14 treatments was -1.08±1.3mm, and the air gap between the bolus (M3) was 0.49±1.16. The difference in the dose distribution between Plan CT and CBCT was -1.38% for PTV1 D95 and 0.39% for SKIN (max) in patient 1. In patient 2, PTV1 D95 showed a difference of 0.63% and SKIN (max) -0.53%. The in vivo measurement showed a difference of -1.47% from the planned dose. Conclusion: thermoplastic Bolus is simpler and takes less time to manufacture compared to those produced by 3D printer. Also compared to conventional bolus, it has high reproducibility in the set-up side and stable results in terms of dose delivery.

Diagnosis of Obstructive Sleep Apnea Syndrome Using Overnight Oximetry Measurement (혈중산소포화도검사를 이용한 폐쇄성 수면무호흡증의 흡증의 진단)

  • Youn, Tak;Park, Doo-Heum;Choi, Kwang-Ho;Kim, Yong-Sik;Woo, Jong-Inn;Kwon, Jun-Soo;Ha, Kyoo-Seob;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.9 no.1
    • /
    • pp.34-40
    • /
    • 2002
  • Objectives: The gold standard for diagnosing obstructive sleep apnea syndrome (OSAS) is nocturnal polysomnography (NPSG). This is rather expensive and somewhat inconvenient, however, and consequently simpler and cheaper alternatives to NPSG have been proposed. Oximetry is appealing because of its widespread availability and ease of application. In this study, we have evaluated whether oximetry alone can be used to diagnose or screen OSAS. The diagnostic performance of an analysis algorithm using arterial oxygen saturation ($SaO_2$) base on 'dip index', mean of $SaO_2$, and CT90 (the percentage of time spent at $SaO_2$<90%) was compared with that of NPSG. Methods: Fifty-six patients referred for NPSG to the Division of Sleep Studies at Seoul National University Hospital, were randomly selected. For each patient, NPSG with oximetry was carried out. We obtained three variables from the oximetry data such as the dip index most linearly correlated with respiratory disturbance index (RDI) from NPSG, mean $SaO_2$, and CT90 with diagnosis from NPSG. In each case, sensitivity, specificity and positive and negative predictive values of oximetry data were calculated. Results: Thirty-nine patients out of fifty-six patients were diagnosed as OSAS with NPSG. Mean RDI was 17.5, mean $SaO_2$ was 94.9%, and mean CT90 was 5.1%. The dip index [4%-4sec] was most linearly correlated with RDI (r=0.861). With dip index [4%-4sec]${\geq}2$ as diagnostic criteria, we obtained sensitivity of 0.95, specificity of 0.71, positive predictive value of 0.88, and negative predictive value of 0.86. Using mean $SaO_2{\leq}97%$, we obtained sensitivity of 0.95, specificity of 0.41, positive predictive value of 0.79, and negative predictive value of 0.78. Using $CT90{\geq}5%$, we obtained sensitivity of 0.28, specificity of 1.00, positive predictive value of 1.00, and negative predictive value of 0.38. Conclusions: The dip index [4%-4sec] and mean $SaO_2{\leq}97%$ obtained from nocturnal oximetry data are helpful in diagnosis of OSAS. CT90${\leq}$5% can be also used in excluding OSAS.

  • PDF

Peak Expiratory Flow(PEF) Measured by Peak Flow Meter and Correlation Between PEF and Other Ventilatory Parameters in Healthy Children (정상 소아에서 최고호기유량계(peak flow meter)로 측정한 최고호기유량(PEF)와 기타 환기기능검사와의 상관관계)

  • Oak, Chul-Ho;Sohn, Kai-Hag;Park, Ki-Ryong;Cho, Hyun-Myung;Jang, Tae-Won;Jung, Maan-Hong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.3
    • /
    • pp.248-259
    • /
    • 2001
  • Background : In diagnosis or monitor of the airway obstruction in bronchial asthma, the measurement of $FEV_1$ in the standard method because of its reproducibility and accuracy. But the measurement of peak expiratory flow(PEF) by peak flow meter is much simpler and easier than that of $FEV_1$ especially in children. Yet there have been still no data of the predicted normal values of PEF measured by peak flow meter in Korean children. This study was conducted to provide equations to predict the normal value of PEF and correlation between PEF and $FEV_1$ in healthy children. Method : PEF was measured by MiniWright peak flow meter, and the forced expiratory volume and the maximum expiratory flow volume curves were measured by Microspiro HI 501(Chest Co.) in 346 healthy children(age:5-16 years, 194 boys and 152 girls) without any respiratory symptoms during 2 weeks before the study. The regression equations for various ventilatory parameters according to age and/or height, and the regression equations of $FEV_1$ by PEF were derived. Results : 1. The regression equation for PEF(L/min) was: $12.6{\times}$age(year)+$3.4{\times}$height(cm)-263($R^2=0.85$) in boys, and $6{\times}$age(year)+$3.9{\times}$height(cm)-293($R^2=0.82$) in girls. 2. The value of FEFmax(L/sec) derived from the maximum expiratory flow volume curves was multiplied by 60 to compare with PEF(L/min), and PEF was faster by 125 L/min in boys and 118 L/min in girls, respectively. 3. The regression equation for $FEV_1$(ml) by PEF(L/min) was:$7{\times}$PEF-550($R^2=0.82$) in boys, and $5.8{\times}$PEF-146 ($R^2=0.81$) in girls, respectively. Conclusion : This study provides regression equations predicting the normal values of PEF by age and/or height in children. And the equations for $FEV_1$, a gold standard of ventilatory function, was predicted by PEF. So, in taking care of children with airway obstruction, PEF measured by the peak flow meter can provide useful information.

  • PDF